메뉴 건너뛰기




Volumn 24, Issue 2, 2014, Pages 144-148

Need for performance protocols in tee and tcd for detection of right to left shunts

Author keywords

Paradoxical stroke; Patent foramen ovale; Stroke; Transcranial doppler; Transesophageal echocardiogram; Transthoracic echocardiogram

Indexed keywords

ADULT; AGED; ARTICLE; CARDIOLOGIST; CEREBROVASCULAR ACCIDENT; CLINICAL PROTOCOL; CONTRAST ENHANCEMENT; CONTROLLED STUDY; DIAGNOSTIC TEST ACCURACY STUDY; DIAGNOSTIC VALUE; ECHOCARDIOGRAPH; FEMALE; HEART RIGHT LEFT SHUNT; HUMAN; IMAGE ANALYSIS; INTERMETHOD COMPARISON; MAJOR CLINICAL STUDY; MALE; MICROBUBBLE; MIDDLE AGED; NEUROLOGIST; OPERATOR; RADIOLOGIST; RETROSPECTIVE STUDY; SENSITIVITY ANALYSIS; TRANSCRANIAL DOPPLER; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; TRANSIENT ISCHEMIC ATTACK; ADOLESCENT; COMPLICATION; DOPPLER ECHOGRAPHY; ECHOGRAPHY; EVALUATION STUDY; ISCHEMIC ATTACK, TRANSIENT; NEEDS ASSESSMENT; OBSERVER VARIATION; PATENT FORAMEN OVALE; PRACTICE GUIDELINE; PROCEDURES; REPRODUCIBILITY; SENSITIVITY AND SPECIFICITY; STANDARDS; UNITED STATES; VALIDATION STUDY; YOUNG ADULT;

EID: 84896720603     PISSN: 10512284     EISSN: 15526569     Source Type: Journal    
DOI: 10.1111/j.1552-6569.2012.00729.x     Document Type: Article
Times cited : (1)

References (30)
  • 1
    • 0034840351 scopus 로고    scopus 로고
    • Patent foramen ovale: a review of associated conditions and the impact of physiological size
    • Kerut EK, Norfleet WT, Plotnick GD, et al. Patent foramen ovale: a review of associated conditions and the impact of physiological size. J Am Coll Cardiol 2001;38:613-623.
    • (2001) J Am Coll Cardiol , vol.38 , pp. 613-623
    • Kerut, E.K.1    Norfleet, W.T.2    Plotnick, G.D.3
  • 2
    • 0021352808 scopus 로고
    • Incidence and size of patent foramen ovale during the first 10 decades of life: an autopsy study of 965 normal hearts
    • Hagen PT, Scholz DG, Edwards WD. Incidence and size of patent foramen ovale during the first 10 decades of life: an autopsy study of 965 normal hearts. Mayo Clin Proc 1984;59:17-20.
    • (1984) Mayo Clin Proc , vol.59 , pp. 17-20
    • Hagen, P.T.1    Scholz, D.G.2    Edwards, W.D.3
  • 3
    • 0028137779 scopus 로고
    • Patent foramen ovale: an anatomical study. Apropos of 500 consecutive autopsies
    • Penther P. Patent foramen ovale: an anatomical study. Apropos of 500 consecutive autopsies. Arch Mal Coeur Vaiss 1994;87:15-21.
    • (1994) Arch Mal Coeur Vaiss , vol.87 , pp. 15-21
    • Penther, P.1
  • 4
    • 32944463757 scopus 로고    scopus 로고
    • Comparison of transthoracic echocardiography using second harmonic imaging, transcranial Doppler, and transesophageal echocardiography for the detection of patent foramen ovale in stroke patients
    • Souteyrand G, Motreff P, Lusson JR, et al. Comparison of transthoracic echocardiography using second harmonic imaging, transcranial Doppler, and transesophageal echocardiography for the detection of patent foramen ovale in stroke patients. Eur J Echocardiogr 2006;7:147-154.
    • (2006) Eur J Echocardiogr , vol.7 , pp. 147-154
    • Souteyrand, G.1    Motreff, P.2    Lusson, J.R.3
  • 5
    • 0026212234 scopus 로고
    • The frequency of patent foramen ovale in patients with ischemic stroke: a transesophageal echocardiographic study
    • Chen WJ, Lin SL, Cheng JJ, et al. The frequency of patent foramen ovale in patients with ischemic stroke: a transesophageal echocardiographic study. J Formos Med Assoc 1991;90:744-748.
    • (1991) J Formos Med Assoc , vol.90 , pp. 744-748
    • Chen, W.J.1    Lin, S.L.2    Cheng, J.J.3
  • 6
    • 0026733037 scopus 로고
    • Diagnosis of patent foramen ovale by transesophageal echocardiography and association with cerebral and peripheral embolic events
    • Hausmann D, Mugge A, Becht I, et al. Diagnosis of patent foramen ovale by transesophageal echocardiography and association with cerebral and peripheral embolic events. Am J Cardiol 1992;70:668-672.
    • (1992) Am J Cardiol , vol.70 , pp. 668-672
    • Hausmann, D.1    Mugge, A.2    Becht, I.3
  • 7
    • 0035857141 scopus 로고    scopus 로고
    • Patent Foramen Ovale and Atrial Septal Aneurysm Study Group. Recurrent cerebrovascular events associated with patent foramen ovale, atrial septal aneurysm, or both
    • Mas JL, Arquizan C, Lamy C, et al. Patent Foramen Ovale and Atrial Septal Aneurysm Study Group. Recurrent cerebrovascular events associated with patent foramen ovale, atrial septal aneurysm, or both. N Engl J Med 2001;345(24):1740-1746.
    • (2001) N Engl J Med , vol.345 , Issue.24 , pp. 1740-1746
    • Mas, J.L.1    Arquizan, C.2    Lamy, C.3
  • 8
    • 77951228209 scopus 로고    scopus 로고
    • Patent foramen ovale with atrial septal aneurysm may contribute to white matter lesions in stroke patients
    • Ueno Y, Shimada Y, Tanaka R, et al. Patent foramen ovale with atrial septal aneurysm may contribute to white matter lesions in stroke patients. Cerebrovasc Dis 2010;30:15-22.
    • (2010) Cerebrovasc Dis , vol.30 , pp. 15-22
    • Ueno, Y.1    Shimada, Y.2    Tanaka, R.3
  • 9
    • 0027324975 scopus 로고
    • Comparison of diagnostic techniques for the detection of a patent foramen ovale in stroke patients
    • Di Tullio M, Sacco RL, Venketasubramanian N, et al. Comparison of diagnostic techniques for the detection of a patent foramen ovale in stroke patients. Stroke 1993;24:1020-1024.
    • (1993) Stroke , vol.24 , pp. 1020-1024
    • Di Tullio, M.1    Sacco, R.L.2    Venketasubramanian, N.3
  • 10
    • 9144246954 scopus 로고    scopus 로고
    • Increased pelvic vein thrombi in cryptogenic stroke: results of the Paradoxical Emboli from Large Veins in Ischemic Stroke (PELVIS) study
    • Cramer SC, Rordorf G, Maki JH, et al. Increased pelvic vein thrombi in cryptogenic stroke: results of the Paradoxical Emboli from Large Veins in Ischemic Stroke (PELVIS) study. Stroke 2004;35(1):46-50.
    • (2004) Stroke , vol.35 , Issue.1 , pp. 46-50
    • Cramer, S.C.1    Rordorf, G.2    Maki, J.H.3
  • 11
    • 0027994381 scopus 로고
    • Comparison of transesophageal and transthoracic echocardiography with contrast and color flow Doppler in the detection of patent foramen ovale
    • Belkin RN, Pollack BD, Ruggiero ML, et al. Comparison of transesophageal and transthoracic echocardiography with contrast and color flow Doppler in the detection of patent foramen ovale. Am Heart J 1994;128:520-525.
    • (1994) Am Heart J , vol.128 , pp. 520-525
    • Belkin, R.N.1    Pollack, B.D.2    Ruggiero, M.L.3
  • 12
    • 0033565148 scopus 로고    scopus 로고
    • Detection of patent foramen ovale. Transesophageal echocardiography and transcranial Doppler sonography with ultrasound contrast media are "supplementary, not competing, diagnostic methods
    • Heckmann JG, Niedermeier W, Brandt-Pholmann M, et al. Detection of patent foramen ovale. Transesophageal echocardiography and transcranial Doppler sonography with ultrasound contrast media are "supplementary, not competing, diagnostic methods." Med Klin 1999;94:367-370.
    • (1999) Med Klin , vol.94 , pp. 367-370
    • Heckmann, J.G.1    Niedermeier, W.2    Brandt-Pholmann, M.3
  • 13
    • 0028059955 scopus 로고
    • Transesophageal echocardiography and contrast-TCD in the detection of a patent foramen ovale: experiences with 111 patients
    • Klotzsch C, Janssen G, Berlit P. Transesophageal echocardiography and contrast-TCD in the detection of a patent foramen ovale: experiences with 111 patients. Neurology 1994;44:1603-1606.
    • (1994) Neurology , vol.44 , pp. 1603-1606
    • Klotzsch, C.1    Janssen, G.2    Berlit, P.3
  • 14
    • 58749109816 scopus 로고    scopus 로고
    • Contrast transcranial Doppler can diagnose large patent foramen ovale
    • Kobayashi K, Iguchi Y, Kimura K, et al. Contrast transcranial Doppler can diagnose large patent foramen ovale. Cerbrovasc Dis 2009;27:230-234.
    • (2009) Cerbrovasc Dis , vol.27 , pp. 230-234
    • Kobayashi, K.1    Iguchi, Y.2    Kimura, K.3
  • 15
    • 55649107701 scopus 로고    scopus 로고
    • Cryptogenic Stroke and patent foramen ovale: clinical clues to paradoxical embolism
    • Ozdemir AO, Tamayo A, Munoz C, et al. Cryptogenic Stroke and patent foramen ovale: clinical clues to paradoxical embolism. J Neurol Sci 2008;275:121-127.
    • (2008) J Neurol Sci , vol.275 , pp. 121-127
    • Ozdemir, A.O.1    Tamayo, A.2    Munoz, C.3
  • 16
    • 0030788936 scopus 로고    scopus 로고
    • Complementarity of contrast transcranial Doppler and contrast transesophageal echocardiography for the detection of patent foramen ovale in stroke patients
    • Devuyst G, Despland PA, Bogousslavsky J, et al. Complementarity of contrast transcranial Doppler and contrast transesophageal echocardiography for the detection of patent foramen ovale in stroke patients. Eur Neurol 1997;38:21-25.
    • (1997) Eur Neurol , vol.38 , pp. 21-25
    • Devuyst, G.1    Despland, P.A.2    Bogousslavsky, J.3
  • 17
    • 0345062319 scopus 로고    scopus 로고
    • Contrast transcranial Doppler ultrasound in the detection of right-to-left shunts: comparison of different procedures and different contrast agents
    • Droste DW, Kriete JU, Stypmann J, et al. Contrast transcranial Doppler ultrasound in the detection of right-to-left shunts: comparison of different procedures and different contrast agents. Stroke 1999;30:1827-1832.
    • (1999) Stroke , vol.30 , pp. 1827-1832
    • Droste, D.W.1    Kriete, J.U.2    Stypmann, J.3
  • 18
    • 65549106979 scopus 로고    scopus 로고
    • Transesophageal echocardiography and transcranial color Doppler: independent or complementary diagnostic tests for cardiologists in the detection of patent foramen ovale?
    • Mangiafico S, Scandura S, Ussia GP, et al. Transesophageal echocardiography and transcranial color Doppler: independent or complementary diagnostic tests for cardiologists in the detection of patent foramen ovale? J Cardiovasc Med 2009;10:143-148.
    • (2009) J Cardiovasc Med , vol.10 , pp. 143-148
    • Mangiafico, S.1    Scandura, S.2    Ussia, G.P.3
  • 19
    • 0033773515 scopus 로고    scopus 로고
    • Detection of Right-to-Left Shunt with Ultrasound Contrast Agent and Transcranial Doppler Sonography
    • Jauss M, Zanette E. Detection of Right-to-Left Shunt with Ultrasound Contrast Agent and Transcranial Doppler Sonography. Cerbrovasc Dis 2000;10:490-496.
    • (2000) Cerbrovasc Dis , vol.10 , pp. 490-496
    • Jauss, M.1    Zanette, E.2
  • 20
    • 0033067564 scopus 로고    scopus 로고
    • Methodological parameters influence the detection of right-to-left shunts by contrast transcranial Doppler ultrasonography
    • Schwarze JJ, Sander D, Kukla C, et al. Methodological parameters influence the detection of right-to-left shunts by contrast transcranial Doppler ultrasonography. Stroke 1999;30:1234-1239.
    • (1999) Stroke , vol.30 , pp. 1234-1239
    • Schwarze, J.J.1    Sander, D.2    Kukla, C.3
  • 21
    • 34548178065 scopus 로고    scopus 로고
    • Effect of body positioning during transcranial Doppler detection of right-to-left shunts
    • Lao AY, Sharma VK, Tsivgoulis G, et al. Effect of body positioning during transcranial Doppler detection of right-to-left shunts. Eur J Neurol 2007;14:1035-1039.
    • (2007) Eur J Neurol , vol.14 , pp. 1035-1039
    • Lao, A.Y.1    Sharma, V.K.2    Tsivgoulis, G.3
  • 22
    • 1942499594 scopus 로고    scopus 로고
    • Right-to-left shunts detected by transesophageal echocardiography and transcranial Doppler sonography
    • Droste DW, Schmidt-Rimpler C, Wichter T, et al. Right-to-left shunts detected by transesophageal echocardiography and transcranial Doppler sonography. Cerebrovasc Dis 2004;17:191-196.
    • (2004) Cerebrovasc Dis , vol.17 , pp. 191-196
    • Droste, D.W.1    Schmidt-Rimpler, C.2    Wichter, T.3
  • 23
    • 0030481612 scopus 로고    scopus 로고
    • Patent foramen ovale and transcranial Doppler: comparison of different procedures
    • Zanette EM, Mancini G, De Castro S, et al. Patent foramen ovale and transcranial Doppler: comparison of different procedures. Stroke 1996;27:2251-2255.
    • (1996) Stroke , vol.27 , pp. 2251-2255
    • Zanette, E.M.1    Mancini, G.2    De Castro, S.3
  • 24
    • 0033943574 scopus 로고    scopus 로고
    • Contrast transcranial Doppler ultrasound in the detection of right-to-left shunts: time window and threshold in microbubble numbers
    • Droste DW, Silling K, Stypmann J, et al. Contrast transcranial Doppler ultrasound in the detection of right-to-left shunts: time window and threshold in microbubble numbers. Stroke 2000;31:1640-1645.
    • (2000) Stroke , vol.31 , pp. 1640-1645
    • Droste, D.W.1    Silling, K.2    Stypmann, J.3
  • 25
    • 0036000302 scopus 로고    scopus 로고
    • Contrast transcranial Doppler ultrasound in the detection of right-to-left shunts: comparison of Echovist-200 and Echovist-300, timing of the Valsalva maneuver, and general recommendations for the performance of the test
    • Droste DW, Jekentaite R, Stypmann J, et al. Contrast transcranial Doppler ultrasound in the detection of right-to-left shunts: comparison of Echovist-200 and Echovist-300, timing of the Valsalva maneuver, and general recommendations for the performance of the test. Cerebrovasc Dis 2002;13:235-241.
    • (2002) Cerebrovasc Dis , vol.13 , pp. 235-241
    • Droste, D.W.1    Jekentaite, R.2    Stypmann, J.3
  • 26
    • 78650417539 scopus 로고    scopus 로고
    • CLOSURE I Investigators. Study design of CLOSURE I: A prospective, multicenter, randomized controlled trial to evaluate the safety and efficacy of the STARFlex® Septal Closure System versus best medical therapy in patients with a stroke or transient ischemic attack due to presumed paradoxical embolism through a patent foramen ovale
    • Furlan AJ, Reisman M, Massaro J, et al. CLOSURE I Investigators. Study design of CLOSURE I: A prospective, multicenter, randomized controlled trial to evaluate the safety and efficacy of the STARFlex® Septal Closure System versus best medical therapy in patients with a stroke or transient ischemic attack due to presumed paradoxical embolism through a patent foramen ovale. Stroke 2010;41:2872-2883.
    • (2010) Stroke , vol.41 , pp. 2872-2883
    • Furlan, A.J.1    Reisman, M.2    Massaro, J.3
  • 27
    • 58149334924 scopus 로고    scopus 로고
    • On behalf of CODICIA (Right-to-Left Shunt in Cryptogenic Stroke) Study; for the Stroke Project of the Cerebrovascular Diseases Study Group, Spanish Society of Neurology. Recurrent stroke and massive right-to-left shunt. Results from the Prospective Spanish Multicenter (CODICIA) Study
    • Serena J, Marti-Fa'bregas J, Santamarina E, et al. On behalf of CODICIA (Right-to-Left Shunt in Cryptogenic Stroke) Study; for the Stroke Project of the Cerebrovascular Diseases Study Group, Spanish Society of Neurology. Recurrent stroke and massive right-to-left shunt. Results from the Prospective Spanish Multicenter (CODICIA) Study. Stroke 2008;39:3131-3136.
    • (2008) Stroke , vol.39 , pp. 3131-3136
    • Serena, J.1    Marti-Fa'bregas, J.2    Santamarina, E.3
  • 28
    • 56349137323 scopus 로고    scopus 로고
    • Maximal potential patent foramen diameter does not correlate with the type or frequency of the neurologic event prior to closure
    • Kutty S, Brown K, Qureshi AM, et al. Maximal potential patent foramen diameter does not correlate with the type or frequency of the neurologic event prior to closure. Cardiology 2009;113:111-115.
    • (2009) Cardiology , vol.113 , pp. 111-115
    • Kutty, S.1    Brown, K.2    Qureshi, A.M.3
  • 29
    • 67650730432 scopus 로고    scopus 로고
    • Unilateral versus bilateral middle cerebral artery detection of right-to-left shunt by power M-mode transcranial Doppler
    • Jesurum JT, Fuller CJ, Moehring MA, et al. Unilateral versus bilateral middle cerebral artery detection of right-to-left shunt by power M-mode transcranial Doppler. J Neuroimaging 2009;19:235-241.
    • (2009) J Neuroimaging , vol.19 , pp. 235-241
    • Jesurum, J.T.1    Fuller, C.J.2    Moehring, M.A.3
  • 30
    • 84896723557 scopus 로고    scopus 로고
    • Prospective, Randomized Investigation to Evaluate Incidence of Headache Reduction in Subjects with Migraine and PFO Using the AMPLATZER PFO Occluder to Medical Management. ClinicalTrials.gov Identifier: NCT00355056
    • Prospective, Randomized Investigation to Evaluate Incidence of Headache Reduction in Subjects with Migraine and PFO Using the AMPLATZER PFO Occluder to Medical Management. ClinicalTrials.gov Identifier: NCT00355056


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.