메뉴 건너뛰기




Volumn 14, Issue 9, 2007, Pages 1035-1039

Effect of body positioning during transcranial Doppler detection of right-to-left shunts

Author keywords

Patent foramen ovale; Right to left shunt; Stroke; Transcranial Doppler

Indexed keywords

SODIUM CHLORIDE;

EID: 34548178065     PISSN: 13515101     EISSN: 14681331     Source Type: Journal    
DOI: 10.1111/j.1468-1331.2007.01879.x     Document Type: Article
Times cited : (54)

References (26)
  • 1
    • 23844547935 scopus 로고    scopus 로고
    • Practice Parameter: Recurrent Stroke with patent foramen ovale and atrial septal aneurysm: Report of the Quality Standards Subcommittee of the American Homma S, Sacco RL. Patent Foramen Ovale and Stroke
    • Messe SR, Silverman JE, Kizer JR, et al. Practice Parameter: Recurrent Stroke with patent foramen ovale and atrial septal aneurysm: Report of the Quality Standards Subcommittee of the American Homma S, Sacco RL. Patent Foramen Ovale and Stroke. Circulation 2005 112 : 1063 1072.
    • (2005) Circulation , vol.112 , pp. 1063-1072
    • Messe, S.R.1    Silverman, J.E.2    Kizer, J.R.3
  • 2
    • 28244472771 scopus 로고    scopus 로고
    • Clinical practice. Patent Foramen Ovale in young adults with unexplained stroke
    • Kizer JR, Devereux R. Clinical practice. Patent Foramen Ovale in young adults with unexplained stroke. New England Journal of Medicine 2005 353 : 2361 2372.
    • (2005) New England Journal of Medicine , vol.353 , pp. 2361-2372
    • Kizer, J.R.1    Devereux, R.2
  • 3
    • 3042759490 scopus 로고    scopus 로고
    • Risk of decompression illness in relation to the presence and size of PFO
    • Torti SR, Billinger M, Schweraman M, et al. Risk of decompression illness in relation to the presence and size of PFO. European Heart Journal 2004 12 : 1014 1020.
    • (2004) European Heart Journal , vol.12 , pp. 1014-1020
    • Torti, S.R.1    Billinger, M.2    Schweraman, M.3
  • 4
    • 12844264134 scopus 로고    scopus 로고
    • Patent foramen ovale and diving
    • Germonpre P. Patent foramen ovale and diving. Cardiology Clinics 2005 1 : 97 104.
    • (2005) Cardiology Clinics , vol.1 , pp. 97-104
    • Germonpre, P.1
  • 5
    • 0031041076 scopus 로고    scopus 로고
    • Cohort study of multiple brain lesions in sport divers: Role of a patent foramen ovale
    • Knauth M, Ries S, Pohimann S, et al. Cohort study of multiple brain lesions in sport divers: role of a patent foramen ovale. British Medical Journal 1997 314 : 701 705.
    • (1997) British Medical Journal , vol.314 , pp. 701-705
    • Knauth, M.1    Ries, S.2    Pohimann, S.3
  • 6
    • 33750887052 scopus 로고    scopus 로고
    • Transcatheter closure of PFO in patients with migraine headache
    • Spies C, Schrader R. Transcatheter closure of PFO in patients with migraine headache. Journal of Interventional Cardiology 2006 19 : 552 557.
    • (2006) Journal of Interventional Cardiology , vol.19 , pp. 552-557
    • Spies, C.1    Schrader, R.2
  • 8
    • 0038338404 scopus 로고    scopus 로고
    • Prevalence of PFO in subjects with obstructive sleep apnea: A transcranial Doppler study
    • Beelke M, Angeli S, del Sette M, et al. Prevalence of PFO in subjects with obstructive sleep apnea: a transcranial Doppler study. Sleep Medicine 2003 4 : 219 213.
    • (2003) Sleep Medicine , vol.4 , pp. 219-213
    • Beelke, M.1    Angeli, S.2    Del Sette, M.3
  • 9
    • 0028337578 scopus 로고
    • A comparison of transesophageal echocardiography and transcranial Doppler sonography with contrast medium in the detection of patent foramen ovale
    • Jauss M, Kaps M, Keberle M, Haberbosch W, Dorndorf W. A comparison of transesophageal echocardiography and transcranial Doppler sonography with contrast medium in the detection of patent foramen ovale. Stroke 1994 25 : 1265 1267.
    • (1994) Stroke , vol.25 , pp. 1265-1267
    • Jauss, M.1    Kaps, M.2    Keberle, M.3    Haberbosch, W.4    Dorndorf, W.5
  • 10
    • 0027932157 scopus 로고
    • Comparison of transcranial contrast Doppler sonography and transesophageal contrast echocardiography for the detection of patent foramen ovale in young stroke patients
    • Job FP, Ringelstein EB, Grafen Y, et al. Comparison of transcranial contrast Doppler sonography and transesophageal contrast echocardiography for the detection of patent foramen ovale in young stroke patients. American Journal of Cardiology 1994 74 : 381 384.
    • (1994) American Journal of Cardiology , vol.74 , pp. 381-384
    • Job, F.P.1    Ringelstein, E.B.2    Grafen, Y.3
  • 11
    • 0031861858 scopus 로고    scopus 로고
    • The need to quantify right to left shunt in acute ischemic stroke: A case control study
    • Serena J, Segura T, Perez-Ayuso MJ, Bassaganyas J, Molins A, Davalos A. The need to quantify right to left shunt in acute ischemic stroke: a case control study. Stroke 1998 29 : 1322 1328.
    • (1998) Stroke , vol.29 , pp. 1322-1328
    • Serena, J.1    Segura, T.2    Perez-Ayuso, M.J.3    Bassaganyas, J.4    Molins, A.5    Davalos, A.6
  • 12
    • 0030788936 scopus 로고    scopus 로고
    • Complementarity of contrast transcranial Doppler and contrast transesophageal echocardiography for the detection of patent foramen ovale in stroke patients
    • Devuyst G, Despland PA, Bogousslavsky J, Jeanrenaud X. Complementarity of contrast transcranial Doppler and contrast transesophageal echocardiography for the detection of patent foramen ovale in stroke patients. European Neurology 1997 38 : 21 25.
    • (1997) European Neurology , vol.38 , pp. 21-25
    • Devuyst, G.1    Despland, P.A.2    Bogousslavsky, J.3    Jeanrenaud, X.4
  • 13
    • 4944240778 scopus 로고    scopus 로고
    • Power M mode transcranial Doppler for diagnosis of patent foramen ovale and assessing transcatheter closure
    • Spencer MP, Moehring MA, Jesurum J, Gray WA, Olsen JV, Reisman M. Power M mode transcranial Doppler for diagnosis of patent foramen ovale and assessing transcatheter closure. Journal of Neuroimaging 2004 14 : 342 349.
    • (2004) Journal of Neuroimaging , vol.14 , pp. 342-349
    • Spencer, M.P.1    Moehring, M.A.2    Jesurum, J.3    Gray, W.A.4    Olsen, J.V.5    Reisman, M.6
  • 14
    • 0030481612 scopus 로고    scopus 로고
    • Patent foramen ovale and transcranial Doppler: Comparison of different procedures
    • Zanette EM, Mancini G, De Castro S, Solaro M, Cartoni D, Chiarotti F. Patent foramen ovale and transcranial Doppler: Comparison of different procedures. Stroke 1997 27 : 2251 2255.
    • (1997) Stroke , vol.27 , pp. 2251-2255
    • Zanette, E.M.1    Mancini, G.2    De Castro, S.3    Solaro, M.4    Cartoni, D.5    Chiarotti, F.6
  • 15
    • 0033067564 scopus 로고    scopus 로고
    • Methodological parameters influence the detection of right to left shunts by contrast transcranial Doppler ultrasonography
    • Schwarze JJ, Sander D, Kukla C, Wittich I, Babikian VL, Klingelhofer J. Methodological parameters influence the detection of right to left shunts by contrast transcranial Doppler ultrasonography. Stroke 1999 30 : 1234 1239.
    • (1999) Stroke , vol.30 , pp. 1234-1239
    • Schwarze, J.J.1    Sander, D.2    Kukla, C.3    Wittich, I.4    Babikian, V.L.5    Klingelhofer, J.6
  • 16
    • 0036713359 scopus 로고    scopus 로고
    • Optimizing the technique of contrast transcranial Doppler ultrasound in the detection of right to left shunts
    • Droste DW, Lakemeier S, Wichter T, et al. Optimizing the technique of contrast transcranial Doppler ultrasound in the detection of right to left shunts. Stroke 2002 33 : 2211 2216.
    • (2002) Stroke , vol.33 , pp. 2211-2216
    • Droste, D.W.1    Lakemeier, S.2    Wichter, T.3
  • 17
    • 0141790118 scopus 로고    scopus 로고
    • The position of the patients in the diagnosis of patent foramen ovale by transcranial Doppler
    • Telman G, Kouperberg E, Sprecher E, Yarnitsky D. The position of the patients in the diagnosis of patent foramen ovale by transcranial Doppler. Journal of Neuroimaging 2003 13 : 356 358.
    • (2003) Journal of Neuroimaging , vol.13 , pp. 356-358
    • Telman, G.1    Kouperberg, E.2    Sprecher, E.3    Yarnitsky, D.4
  • 18
    • 0033773515 scopus 로고    scopus 로고
    • Detection of right to left shunt with ultrasound contrast agent and transcranial Doppler sonography
    • Jauss M, Zanette E. Detection of right to left shunt with ultrasound contrast agent and transcranial Doppler sonography. Cerebrovascular Diseases 2000 10 : 490 496.
    • (2000) Cerebrovascular Diseases , vol.10 , pp. 490-496
    • Jauss, M.1    Zanette, E.2
  • 19
    • 4944240778 scopus 로고    scopus 로고
    • Power M mode transcranial Doppler for diagnosis of patent foramen ovale and assessing transcatheter closure
    • Spencer MP, Moehring MA, Jesurum J, Gray WA, Olsen JV, Reisman M. Power M mode transcranial Doppler for diagnosis of patent foramen ovale and assessing transcatheter closure. Journal of Neuroimaging 2004 14 : 342 349.
    • (2004) Journal of Neuroimaging , vol.14 , pp. 342-349
    • Spencer, M.P.1    Moehring, M.A.2    Jesurum, J.3    Gray, W.A.4    Olsen, J.V.5    Reisman, M.6
  • 20
    • 0028082344 scopus 로고
    • Characteristics of patent foramen ovale associated with cryptogenic stroke: A biplane transesophageal echocardiographic study
    • Homma S, Di Tullio MR, Sacco RL, Mihalatos D, Li Mandri G, Mohr JP. Characteristics of patent foramen ovale associated with cryptogenic stroke: a biplane transesophageal echocardiographic study. Stroke 1994 25 : 582 586.
    • (1994) Stroke , vol.25 , pp. 582-586
    • Homma, S.1    Di Tullio, M.R.2    Sacco, R.L.3    Mihalatos, D.4    Li Mandri, G.5    Mohr, J.P.6
  • 21
    • 0028832597 scopus 로고
    • Recurrent cerebrovascular events in patients with patent foramen ovale, atrial septal aneurysm or both and cryptogenic stroke or transient ischemic attack: French study Group on Patent Foramen Ovale and Atrial Septal Aneurysm
    • Mas JL, Zuber M. Recurrent cerebrovascular events in patients with patent foramen ovale, atrial septal aneurysm or both and cryptogenic stroke or transient ischemic attack: French study Group on Patent Foramen Ovale and Atrial Septal Aneurysm. American Heart Journal 1995 130 : 1083 1088.
    • (1995) American Heart Journal , vol.130 , pp. 1083-1088
    • Mas, J.L.1    Zuber, M.2
  • 22
    • 0031971359 scopus 로고    scopus 로고
    • Patent foramen ovale size and embolic brain imaging findings with ischemic stroke
    • Steiner MM, Di Tullio MR, Rundek T, et al. Patent foramen ovale size and embolic brain imaging findings with ischemic stroke. Stroke 1998 29 : 944 948.
    • (1998) Stroke , vol.29 , pp. 944-948
    • Steiner, M.M.1    Di Tullio, M.R.2    Rundek, T.3
  • 23
    • 27144506167 scopus 로고    scopus 로고
    • Microbubbles, pathophysiology and clinical implications
    • Barak M, Katz Y. Microbubbles, pathophysiology and clinical implications. Chest 2005 128 : 2918 2932.
    • (2005) Chest , vol.128 , pp. 2918-2932
    • Barak, M.1    Katz, Y.2
  • 24
    • 0028137779 scopus 로고
    • Patent foramen ovale: An anatomical study. Apropos of 500 consecutive autopsies
    • Penter P. Patent foramen ovale: an anatomical study. Apropos of 500 consecutive autopsies. Archives des Maladies du Coeur et des Vaisseaux 1994 87 : 15 21.
    • (1994) Archives des Maladies du Coeur et des Vaisseaux , vol.87 , pp. 15-21
    • Penter, P.1
  • 26
    • 33644867063 scopus 로고    scopus 로고
    • Guidelines for prevention of stroke in patients with ischemic stroke or transient ischemic attack: A statement for healthcare professionals from the American Heart Association/American Stroke Association Council on Stroke: Co-sponsored by the Council on Cardiovascular Radiology and Intervention: The American Academy of Neurology affirms the value of this guideline
    • Sacco RL, Adams R, Albers G, et al. Guidelines for prevention of stroke in patients with ischemic stroke or transient ischemic attack: a statement for healthcare professionals from the American Heart Association/American Stroke Association Council on Stroke: co-sponsored by the Council on Cardiovascular Radiology and Intervention: the American Academy of Neurology affirms the value of this guideline. Stroke 2006 37 : 577 617.
    • (2006) Stroke , vol.37 , pp. 577-617
    • Sacco, R.L.1    Adams, R.2    Albers, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.