Volumn 19, Issue 1, 2014, Pages 38-46

Clinical use of pulse oximetry: Official guidelines from the Thoracic Society of Australia and New Zealand

Author keywords

clinical medicine; guideline; hypoxemia; oxygen; pulse oximetry

Indexed keywords

ALARM MONITOR; ARTERIAL OXYGEN SATURATION; ARTERIAL OXYGEN TENSION; ARTICLE; ARTIFACT; BREATHING DISORDER; CARBON MONOXIDE INTOXICATION; EMERGENCY CARE; FETUS MONITORING; HOME CARE; HUMAN; HYPOXEMIA; INFECTION CONTROL; INFORMATION PROCESSING; INTENSIVE CARE; LIGHT; LUNG GAS EXCHANGE; LUNG VENTILATION; METHEMOGLOBINEMIA; NEWBORN ASSESSMENT; OUTPATIENT CARE; OXYGEN THERAPY; PATIENT MONITORING; PERIOPERATIVE PERIOD; PRACTICE GUIDELINE; PRIMARY MEDICAL CARE; PRIORITY JOURNAL; PULMONARY REHABILITATION; PULSE OXIMETER; PULSE OXIMETRY; RESPIRATORY FAILURE; RESPONSE TIME; SENSOR;

EID: 84896544058     PISSN: 13237799     EISSN: 14401843     Source Type: Journal    
DOI: 10.1111/resp.12204     Document Type: Article
Times cited : (78)

References (63)
  • 1
    • 0031690110 scopus 로고    scopus 로고
    • Pulse oximetry as a fifth vital sign in emergency geriatric assessment
    • Mower WR, Myers G, Nicklin EL, et al. Pulse oximetry as a fifth vital sign in emergency geriatric assessment. Acad. Emerg. Med. 1998; 5: 858-865.
    • (1998) Acad. Emerg. Med. , vol.5 , pp. 858-865
    • Mower, W.R.1    Myers, G.2    Nicklin, E.L.3
  • 2
    • 0030944520 scopus 로고    scopus 로고
    • Pulse oximetry as a fifth pediatric vital sign
    • Mower WR, Sachs C, Nicklin EL, et al. Pulse oximetry as a fifth pediatric vital sign. Pediatrics 1997; 99: 681-686.
    • (1997) Pediatrics , vol.99 , pp. 681-686
    • Mower, W.R.1    Sachs, C.2    Nicklin, E.L.3
  • 4
    • 21644477707 scopus 로고    scopus 로고
    • Adult domiciliary oxygen therapy. Position statement of the Thoracic Society of Australia and New Zealand
    • McDonald CF, Crockett AJ, Young IH,. Adult domiciliary oxygen therapy. Position statement of the Thoracic Society of Australia and New Zealand. Med. J. Aust. 2005; 182: 621-626.
    • (2005) Med. J. Aust. , vol.182 , pp. 621-626
    • McDonald, C.F.1    Crockett, A.J.2    Young, I.H.3
  • 5
    • 0032741475 scopus 로고    scopus 로고
    • Arterial blood gas reference values for sea level and an altitude of 1,400 meters
    • Crapo RO, Jensen RL, Hegewald M, et al. Arterial blood gas reference values for sea level and an altitude of 1,400 meters. Am. J. Respir. Crit. Care Med. 1999; 160: 1525-1531.
    • (1999) Am. J. Respir. Crit. Care Med. , vol.160 , pp. 1525-1531
    • Crapo, R.O.1    Jensen, R.L.2    Hegewald, M.3
  • 7
    • 33750432875 scopus 로고    scopus 로고
    • Normobaric hypoxia inhalation test vs. Response to airline flight in healthy passengers
    • Kelly PT, Swanney MP, Frampton C, et al. Normobaric hypoxia inhalation test vs. response to airline flight in healthy passengers. Aviat. Space Environ. Med. 2006; 77: 1143-1147.
    • (2006) Aviat. Space Environ. Med. , vol.77 , pp. 1143-1147
    • Kelly, P.T.1    Swanney, M.P.2    Frampton, C.3
  • 8
    • 0030741918 scopus 로고    scopus 로고
    • Does significant arterial hypoxemia alter vital signs?
    • Thrush DN, Downs JB, Hodges M, et al. Does significant arterial hypoxemia alter vital signs? J. Clin. Anesth. 1997; 9: 355-357.
    • (1997) J. Clin. Anesth. , vol.9 , pp. 355-357
    • Thrush, D.N.1    Downs, J.B.2    Hodges, M.3
  • 9
    • 33750698270 scopus 로고    scopus 로고
    • Validation of physiological scoring systems in the accident and emergency department
    • Subbe CP, Slater A, Menon D, et al. Validation of physiological scoring systems in the accident and emergency department. Emerg. Med. J. 2006; 23: 841-845.
    • (2006) Emerg. Med. J. , vol.23 , pp. 841-845
    • Subbe, C.P.1    Slater, A.2    Menon, D.3
  • 10
    • 84860904801 scopus 로고    scopus 로고
    • Derivation and validation of a risk adjustment model for predicting seven day mortality in emergency medical admissions: Mixed prospective and retrospective cohort study
    • Goodacre S, Wilson R, Shephard N, et al. Derivation and validation of a risk adjustment model for predicting seven day mortality in emergency medical admissions: mixed prospective and retrospective cohort study. BMJ 2012; 344: e2904.
    • (2012) BMJ , vol.344
    • Goodacre, S.1    Wilson, R.2    Shephard, N.3
  • 11
    • 33744967968 scopus 로고    scopus 로고
    • Prediction of mortality among emergency medical admissions
    • Goodacre S, Turner J, Nicholl J,. Prediction of mortality among emergency medical admissions. Emerg. Med. J. 2006; 23: 372-375.
    • (2006) Emerg. Med. J. , vol.23 , pp. 372-375
    • Goodacre, S.1    Turner, J.2    Nicholl, J.3
  • 12
    • 0025814674 scopus 로고
    • An evaluation of pulse oximetry in prehospital care
    • Aughey K, Hess D, Eitel D, et al. An evaluation of pulse oximetry in prehospital care. Ann. Emerg. Med. 1991; 20: 887-891.
    • (1991) Ann. Emerg. Med. , vol.20 , pp. 887-891
    • Aughey, K.1    Hess, D.2    Eitel, D.3
  • 13
    • 79951503699 scopus 로고    scopus 로고
    • Comparison of two new generation pulse oximeters during emergency ambulance transportation
    • Weber U, Tomschik E, Resch I, et al. Comparison of two new generation pulse oximeters during emergency ambulance transportation. Eur. J. Anaesthesiol. 2011; 28: 92-96.
    • (2011) Eur. J. Anaesthesiol. , vol.28 , pp. 92-96
    • Weber, U.1    Tomschik, E.2    Resch, I.3
  • 14
    • 78049452891 scopus 로고    scopus 로고
    • Effect of high flow oxygen on mortality in chronic obstructive pulmonary disease patients in prehospital setting: Randomised controlled trial
    • Austin MA, Wills KE, Blizzard L, et al. Effect of high flow oxygen on mortality in chronic obstructive pulmonary disease patients in prehospital setting: randomised controlled trial. BMJ 2010; 341: c5462.
    • (2010) BMJ , vol.341
    • Austin, M.A.1    Wills, K.E.2    Blizzard, L.3
  • 15
    • 34248678134 scopus 로고    scopus 로고
    • Do changes in pulse oximeter oxygen saturation predict equivalent changes in arterial oxygen saturation?
    • Perkins GD, McAuley DF, Giles S, et al. Do changes in pulse oximeter oxygen saturation predict equivalent changes in arterial oxygen saturation? Crit. Care 2003; 7: R67.
    • (2003) Crit. Care , vol.7
    • Perkins, G.D.1    McAuley, D.F.2    Giles, S.3
  • 16
    • 34548037928 scopus 로고    scopus 로고
    • Comparison of the SpO2/FIO2 ratio and the PaO2/FIO2 ratio in patients with acute lung injury or ARDS
    • Rice TW, Wheeler AP, Bernard GR, et al. Comparison of the SpO2/FIO2 ratio and the PaO2/FIO2 ratio in patients with acute lung injury or ARDS. Chest 2007; 132: 410-417.
    • (2007) Chest , vol.132 , pp. 410-417
    • Rice, T.W.1    Wheeler, A.P.2    Bernard, G.R.3
  • 17
    • 0034234391 scopus 로고    scopus 로고
    • The accuracy of pulse oximetry in the emergency department
    • Lee WW, Mayberry K, Crapo R, et al. The accuracy of pulse oximetry in the emergency department. Am. J. Emerg. Med. 2000; 18: 427-431.
    • (2000) Am. J. Emerg. Med. , vol.18 , pp. 427-431
    • Lee, W.W.1    Mayberry, K.2    Crapo, R.3
  • 19
    • 57649157639 scopus 로고    scopus 로고
    • Analysis of medical emergency team calls comparing subjective to 'objective' call criteria
    • Santiano N, Young L, Hillman K, et al. Analysis of medical emergency team calls comparing subjective to 'objective' call criteria. Resuscitation 2009; 80: 44-49.
    • (2009) Resuscitation , vol.80 , pp. 44-49
    • Santiano, N.1    Young, L.2    Hillman, K.3
  • 20
    • 0142074238 scopus 로고    scopus 로고
    • Home diagnosis of sleep apnea: A systematic review of the literature
    • Flemons WW, Littner MR, Rowley JA, et al. Home diagnosis of sleep apnea: a systematic review of the literature. Chest 2003; 124: 1543-1579.
    • (2003) Chest , vol.124 , pp. 1543-1579
    • Flemons, W.W.1    Littner, M.R.2    Rowley, J.A.3
  • 21
    • 84857013592 scopus 로고    scopus 로고
    • Interrelationships between body mass, oxygen desaturation, and apnea-hypopnea indices in a sleep clinic population
    • Ling IT, James AL, Hillman DR,. Interrelationships between body mass, oxygen desaturation, and apnea-hypopnea indices in a sleep clinic population. Sleep 2012; 35: 89-96.
    • (2012) Sleep , vol.35 , pp. 89-96
    • Ling, I.T.1    James, A.L.2    Hillman, D.R.3
  • 22
    • 63249117674 scopus 로고    scopus 로고
    • A randomized controlled trial of nurse-led care for symptomatic moderate-severe obstructive sleep apnea
    • Antic NA, Buchan C, Esterman A, et al. A randomized controlled trial of nurse-led care for symptomatic moderate-severe obstructive sleep apnea. Am. J. Respir. Crit. Care Med. 2009; 179: 501-508.
    • (2009) Am. J. Respir. Crit. Care Med. , vol.179 , pp. 501-508
    • Antic, N.A.1    Buchan, C.2    Esterman, A.3
  • 23
    • 79951942894 scopus 로고    scopus 로고
    • A simplified model of screening questionnaire and home monitoring for obstructive sleep apnoea in primary care
    • Chai-Coetzer CL, Antic NA, Rowland LS, et al. A simplified model of screening questionnaire and home monitoring for obstructive sleep apnoea in primary care. Thorax 2011; 66: 213-219.
    • (2011) Thorax , vol.66 , pp. 213-219
    • Chai-Coetzer, C.L.1    Antic, N.A.2    Rowland, L.S.3
  • 24
    • 18644363812 scopus 로고    scopus 로고
    • Six-minute walk, maximal exercise tests: Reproducibility in fibrotic interstitial pneumonia
    • Eaton T, Young P, Milne D, et al. Six-minute walk, maximal exercise tests: reproducibility in fibrotic interstitial pneumonia. Am. J. Respir. Crit. Care Med. 2005; 171: 1150-1157.
    • (2005) Am. J. Respir. Crit. Care Med. , vol.171 , pp. 1150-1157
    • Eaton, T.1    Young, P.2    Milne, D.3
  • 25
    • 33749434364 scopus 로고    scopus 로고
    • Idiopathic pulmonary fibrosis: Prognostic value of changes in physiology and six-minute-walk test
    • Flaherty KR, Andrei AC, Murray S, et al. Idiopathic pulmonary fibrosis: prognostic value of changes in physiology and six-minute-walk test. Am. J. Respir. Crit. Care Med. 2006; 174: 803-809.
    • (2006) Am. J. Respir. Crit. Care Med. , vol.174 , pp. 803-809
    • Flaherty, K.R.1    Andrei, A.C.2    Murray, S.3
  • 26
    • 0031792492 scopus 로고    scopus 로고
    • Screening patients in general practice with COPD for long-term domiciliary oxygen requirement using pulse oximetry
    • Roberts CM, Franklin J, O'Neill A, et al. Screening patients in general practice with COPD for long-term domiciliary oxygen requirement using pulse oximetry. Respir. Med. 1998; 92: 1265-1268.
    • (1998) Respir. Med. , vol.92 , pp. 1265-1268
    • Roberts, C.M.1    Franklin, J.2    O'Neill, A.3
  • 27
    • 84859848362 scopus 로고    scopus 로고
    • Inability of single resting arterial blood gas to predict significant hypoxaemia in chronic obstructive pulmonary disease
    • Trauer JM, Gielen C, Trauer T, et al. Inability of single resting arterial blood gas to predict significant hypoxaemia in chronic obstructive pulmonary disease. Int. Med. J. 2012; 42: 387-394.
    • (2012) Int. Med. J. , vol.42 , pp. 387-394
    • Trauer, J.M.1    Gielen, C.2    Trauer, T.3
  • 29
    • 65349140108 scopus 로고    scopus 로고
    • Oxygen saturation monitoring for the preterm infant: The evidence basis for current practice
    • Finer N, Leone T,. Oxygen saturation monitoring for the preterm infant: the evidence basis for current practice. Pediatr. Res. 2009; 65: 375-380.
    • (2009) Pediatr. Res. , vol.65 , pp. 375-380
    • Finer, N.1    Leone, T.2
  • 30
    • 80051729812 scopus 로고    scopus 로고
    • Hyperoxia in very preterm infants: A systematic review of the literature
    • Deuber C, Terhaar M,. Hyperoxia in very preterm infants: a systematic review of the literature. J. Perinat. Neonatal Nurs. 2011; 25: 268-274.
    • (2011) J. Perinat. Neonatal Nurs. , vol.25 , pp. 268-274
    • Deuber, C.1    Terhaar, M.2
  • 31
    • 0042861328 scopus 로고    scopus 로고
    • Oxygen-saturation targets and outcomes in extremely preterm infants
    • Askie LM, Henderson-Smart DJ, Irwig L, et al. Oxygen-saturation targets and outcomes in extremely preterm infants. N. Engl. J. Med. 2003; 349: 959-967.
    • (2003) N. Engl. J. Med. , vol.349 , pp. 959-967
    • Askie, L.M.1    Henderson-Smart, D.J.2    Irwig, L.3
  • 32
    • 44449153664 scopus 로고    scopus 로고
    • Pulse oxygen saturation levels and arterial oxygen tension values in newborns receiving oxygen therapy in the neonatal intensive care unit: Is 85% to 93% an acceptable range?
    • Castillo A, Sola A, Baquero H, et al. Pulse oxygen saturation levels and arterial oxygen tension values in newborns receiving oxygen therapy in the neonatal intensive care unit: is 85% to 93% an acceptable range? Pediatrics 2008; 121: 882-889.
    • (2008) Pediatrics , vol.121 , pp. 882-889
    • Castillo, A.1    Sola, A.2    Baquero, H.3
  • 33
    • 80052262243 scopus 로고    scopus 로고
    • Pulse oximetry screening for congenital heart defects in newborn infants (PulseOx): A test accuracy study
    • Ewer AK, Middleton LJ, Furmston AT, et al. Pulse oximetry screening for congenital heart defects in newborn infants (PulseOx): a test accuracy study. Lancet 2011; 378: 785-794.
    • (2011) Lancet , vol.378 , pp. 785-794
    • Ewer, A.K.1    Middleton, L.J.2    Furmston, A.T.3
  • 34
    • 34248150312 scopus 로고    scopus 로고
    • Comparison of forehead and digit oximetry in surgical/trauma patients at risk for decreased peripheral perfusion
    • Schallom L, Sona C, McSweeney M, et al. Comparison of forehead and digit oximetry in surgical/trauma patients at risk for decreased peripheral perfusion. Heart Lung 2007; 36: 188-194.
    • (2007) Heart Lung , vol.36 , pp. 188-194
    • Schallom, L.1    Sona, C.2    McSweeney, M.3
  • 35
    • 34247850879 scopus 로고    scopus 로고
    • Evaluation of a new pulse oximeter sensor
    • Fernandez M, Burns K, Calhoun B, et al. Evaluation of a new pulse oximeter sensor. Am. J. Crit. Care 2007; 16: 146-152.
    • (2007) Am. J. Crit. Care , vol.16 , pp. 146-152
    • Fernandez, M.1    Burns, K.2    Calhoun, B.3
  • 36
    • 1842844351 scopus 로고    scopus 로고
    • Forehead SpO2 monitoring compared to finger SpO2 recording in emergency transport
    • Nuhr M, Hoerauf K, Joldzo A, et al. Forehead SpO2 monitoring compared to finger SpO2 recording in emergency transport. Anaesthesia 2004; 59: 390-393.
    • (2004) Anaesthesia , vol.59 , pp. 390-393
    • Nuhr, M.1    Hoerauf, K.2    Joldzo, A.3
  • 37
    • 74549117712 scopus 로고    scopus 로고
    • Comparison of desaturation and resaturation response times between transmission and reflectance pulse oximeters
    • Choi SJ, Ahn HJ, Yang MK, et al. Comparison of desaturation and resaturation response times between transmission and reflectance pulse oximeters. Acta Anaesthesiol. Scand. 2010; 54: 212-217.
    • (2010) Acta Anaesthesiol. Scand. , vol.54 , pp. 212-217
    • Choi, S.J.1    Ahn, H.J.2    Yang, M.K.3
  • 38
    • 34248660829 scopus 로고    scopus 로고
    • Do clinicians know how to use pulse oximetry? A literature review and clinical implications
    • Elliott M, Tate R, Page K,. Do clinicians know how to use pulse oximetry? A literature review and clinical implications. Aust. Crit. Care 2006; 19: 139-144.
    • (2006) Aust. Crit. Care , vol.19 , pp. 139-144
    • Elliott, M.1    Tate, R.2    Page, K.3
  • 39
    • 0024586470 scopus 로고
    • Effects of methemoglobinemia on pulse oximetry and mixed venous oximetry
    • Barker SJ, Tremper KK, Hyatt J,. Effects of methemoglobinemia on pulse oximetry and mixed venous oximetry. Anesthesiology 1989; 70: 112-117.
    • (1989) Anesthesiology , vol.70 , pp. 112-117
    • Barker, S.J.1    Tremper, K.K.2    Hyatt, J.3
  • 40
    • 84855357610 scopus 로고    scopus 로고
    • Interference of patent blue dye with pulse oximetry readings, methemoglobin measurements, and blue urine in sentinel lymph node mapping: A case report and review of the literature
    • Lai HC, Hsu HM, Cherng CH, et al. Interference of patent blue dye with pulse oximetry readings, methemoglobin measurements, and blue urine in sentinel lymph node mapping: a case report and review of the literature. Acta Anaesth. Taiwan. 2011; 49: 162-164.
    • (2011) Acta Anaesth. Taiwan. , vol.49 , pp. 162-164
    • Lai, H.C.1    Hsu, H.M.2    Cherng, C.H.3
  • 41
    • 0030133008 scopus 로고    scopus 로고
    • Accuracy of pulse oximetry in pigmented patients
    • Bothma PA, Joynt GM, Lipman J, et al. Accuracy of pulse oximetry in pigmented patients. S. Afr. Med. J. 1996; 86: 594-596.
    • (1996) S. Afr. Med. J. , vol.86 , pp. 594-596
    • Bothma, P.A.1    Joynt, G.M.2    Lipman, J.3
  • 42
    • 0031707716 scopus 로고    scopus 로고
    • Effect of skin pigmentation on pulse oximetry accuracy in the emergency department
    • Adler JN, Hughes LA, Vivilecchia R, et al. Effect of skin pigmentation on pulse oximetry accuracy in the emergency department. Acad. Emerg. Med. 1998; 5: 965-970.
    • (1998) Acad. Emerg. Med. , vol.5 , pp. 965-970
    • Adler, J.N.1    Hughes, L.A.2    Vivilecchia, R.3
  • 43
    • 44349104866 scopus 로고    scopus 로고
    • Dark skin decreases the accuracy of pulse oximeters at low oxygen saturation: The effects of oximeter probe type and gender
    • tables of contents
    • Feiner JR, Severinghaus JW, Bickler PE,. Dark skin decreases the accuracy of pulse oximeters at low oxygen saturation: the effects of oximeter probe type and gender. Anesth. Analg. 2007; 105: S18-23, tables of contents.
    • (2007) Anesth. Analg. , vol.105
    • Feiner, J.R.1    Severinghaus, J.W.2    Bickler, P.E.3
  • 44
    • 0024504397 scopus 로고
    • Hyperbilirubinemia does not interfere with hemoglobin saturation measured by pulse oximetry
    • Veyckemans F, Baele P, Guillaume JE, et al. Hyperbilirubinemia does not interfere with hemoglobin saturation measured by pulse oximetry. Anesthesiology 1989; 70: 118-122.
    • (1989) Anesthesiology , vol.70 , pp. 118-122
    • Veyckemans, F.1    Baele, P.2    Guillaume, J.E.3
  • 45
    • 33646008827 scopus 로고    scopus 로고
    • Influence of digital clubbing on oxygen saturation measurements by pulse-oximetry in cystic fibrosis patients
    • Van Ginderdeuren F, Van Cauwelaert K, Malfroot A,. Influence of digital clubbing on oxygen saturation measurements by pulse-oximetry in cystic fibrosis patients. J. Cyst. Fibros. 2006; 5: 125-128.
    • (2006) J. Cyst. Fibros. , vol.5 , pp. 125-128
    • Van Ginderdeuren, F.1    Van Cauwelaert, K.2    Malfroot, A.3
  • 46
    • 0038724013 scopus 로고    scopus 로고
    • What is the effect of fingernail polish on pulse oximetry?
    • Chan MM, Chan ED,. What is the effect of fingernail polish on pulse oximetry? Chest 2003; 123: 2163-2164.
    • (2003) Chest , vol.123 , pp. 2163-2164
    • Chan, M.M.1    Chan, E.D.2
  • 47
    • 80052134107 scopus 로고    scopus 로고
    • Effect of nail polish and henna on oxygen saturation determined by pulse oximetry in healthy young adult females
    • Sutcu Cicek H, Gumus S, Deniz O, et al. Effect of nail polish and henna on oxygen saturation determined by pulse oximetry in healthy young adult females. Emerg. Med. J. 2011; 28: 783-785.
    • (2011) Emerg. Med. J. , vol.28 , pp. 783-785
    • Sutcu Cicek, H.1    Gumus, S.2    Deniz, O.3
  • 48
    • 38049066411 scopus 로고    scopus 로고
    • Fingernail polish does not influence pulse oximetry to a clinically relevant dimension
    • Hinkelbein J, Genzwuerker HV,. Fingernail polish does not influence pulse oximetry to a clinically relevant dimension. Intensive Crit. Care Nurs. 2008; 24: 4-5.
    • (2008) Intensive Crit. Care Nurs. , vol.24 , pp. 4-5
    • Hinkelbein, J.1    Genzwuerker, H.V.2
  • 49
  • 50
    • 84858341299 scopus 로고    scopus 로고
    • An assessment of the accuracy of pulse oximeters
    • Milner QJ, Mathews GR,. An assessment of the accuracy of pulse oximeters. Anaesthesia 2012; 67: 396-401.
    • (2012) Anaesthesia , vol.67 , pp. 396-401
    • Milner, Q.J.1    Mathews, G.R.2
  • 51
    • 60649106193 scopus 로고    scopus 로고
    • The effect of motion on pulse oximetry and its clinical significance
    • Petterson MT, Begnoche VL, Graybeal JM,. The effect of motion on pulse oximetry and its clinical significance. Anesth. Analg. 2007; 105: S78-84.
    • (2007) Anesth. Analg. , vol.105
    • Petterson, M.T.1    Begnoche, V.L.2    Graybeal, J.M.3
  • 52
    • 0028300877 scopus 로고
    • Crying wolf: False alarms in a pediatric intensive care unit
    • Lawless ST,. Crying wolf: false alarms in a pediatric intensive care unit. Crit. Care Med. 1994; 22: 981-985.
    • (1994) Crit. Care Med. , vol.22 , pp. 981-985
    • Lawless, S.T.1
  • 53
    • 0032067515 scopus 로고    scopus 로고
    • Sleep states and neonatal pulse oximetry
    • Fletcher J, Page M, Jeffery HE,. Sleep states and neonatal pulse oximetry. Sleep 1998; 21: 305-310.
    • (1998) Sleep , vol.21 , pp. 305-310
    • Fletcher, J.1    Page, M.2    Jeffery, H.E.3
  • 54
    • 0036138902 scopus 로고    scopus 로고
    • Differences in pulse oximetry technology can affect detection of sleep-disorderd breathing in children
    • Brouillette RT, Lavergne J, Leimanis A, et al. Differences in pulse oximetry technology can affect detection of sleep-disorderd breathing in children. Anesth. Analg. 2002; 94: S47-53.
    • (2002) Anesth. Analg. , vol.94
    • Brouillette, R.T.1    Lavergne, J.2    Leimanis, A.3
  • 55
    • 0024511902 scopus 로고
    • Fluorescent light interferes with pulse oximetry
    • Amar D, Neidzwski J, Wald A, et al. Fluorescent light interferes with pulse oximetry. J. Clin. Monit. 1989; 5: 135-136.
    • (1989) J. Clin. Monit. , vol.5 , pp. 135-136
    • Amar, D.1    Neidzwski, J.2    Wald, A.3
  • 56
    • 0642275551 scopus 로고    scopus 로고
    • Does ambient light affect the accuracy of pulse oximetry?
    • Fluck RR, Jr, Schroeder C, Frani G, et al. Does ambient light affect the accuracy of pulse oximetry? Respir. Care 2003; 48: 677-680.
    • (2003) Respir. Care , vol.48 , pp. 677-680
    • Fluck, Jr.R.R.1    Schroeder, C.2    Frani, G.3
  • 57
    • 0033024665 scopus 로고    scopus 로고
    • Delays in the detection of hypoxemia due to site of pulse oximetry probe placement
    • Hamber EA, Bailey PL, James SW, et al. Delays in the detection of hypoxemia due to site of pulse oximetry probe placement. J. Clin. Anesth. 1999; 11: 113-118.
    • (1999) J. Clin. Anesth. , vol.11 , pp. 113-118
    • Hamber, E.A.1    Bailey, P.L.2    James, S.W.3
  • 58
    • 0026583962 scopus 로고
    • Response-time of pulse oximeters assessed using acute decompression
    • Young D, Jewkes C, Spittal M, et al. Response-time of pulse oximeters assessed using acute decompression. Anesth. Analg. 1992; 74: 189-195.
    • (1992) Anesth. Analg. , vol.74 , pp. 189-195
    • Young, D.1    Jewkes, C.2    Spittal, M.3
  • 59
    • 0032525441 scopus 로고    scopus 로고
    • Importance of the pulse oximeter averaging time when measuring oxygen desaturation in sleep apnea
    • Farre R, Montserrat JM, Ballester E, et al. Importance of the pulse oximeter averaging time when measuring oxygen desaturation in sleep apnea. Sleep 1998; 21: 386-390.
    • (1998) Sleep , vol.21 , pp. 386-390
    • Farre, R.1    Montserrat, J.M.2    Ballester, E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.