메뉴 건너뛰기




Volumn 11, Issue 2, 1999, Pages 113-118

Delays in the detection of hypoxemia due to site of pulse oximetry probe placement

Author keywords

Hypoxemia; Monitoring site; Pulse oximetry

Indexed keywords

ADULT; ARTICLE; CLINICAL ARTICLE; EAR; HAND; HUMAN; HUMAN EXPERIMENT; HYPERCAPNIA; HYPOXEMIA; NORMAL HUMAN; OXYGEN SATURATION; PRIORITY JOURNAL; PULSE OXIMETER; PULSE OXIMETRY; TOE;

EID: 0033024665     PISSN: 09528180     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0952-8180(99)00010-0     Document Type: Article
Times cited : (43)

References (24)
  • 1
    • 0024562215 scopus 로고
    • Pulse oximetry
    • Kelleher J.F. Pulse oximetry. J Clin Monit. 5:1989;37-62.
    • (1989) J Clin Monit , vol.5 , pp. 37-62
    • Kelleher, J.F.1
  • 2
    • 0028946159 scopus 로고
    • Pulse oximetry - Clinical implications and recent technical developments
    • Lindberg L.G., Lennmarken C., Vegfors M. Pulse oximetry - clinical implications and recent technical developments. Acta Anaesthesiol Scand. 39:1995;279-287.
    • (1995) Acta Anaesthesiol Scand , vol.39 , pp. 279-287
    • Lindberg, L.G.1    Lennmarken, C.2    Vegfors, M.3
  • 4
    • 0025981812 scopus 로고
    • Potential errors in pulse oximetry. II. Effects of changes in saturation and signal quality
    • Webb R.K., Ralston A.C., Runciman W.B. Potential errors in pulse oximetry. II. Effects of changes in saturation and signal quality. Anaesthesia. 46:1991;207-212.
    • (1991) Anaesthesia , vol.46 , pp. 207-212
    • Webb, R.K.1    Ralston, A.C.2    Runciman, W.B.3
  • 5
    • 0026595952 scopus 로고
    • Decreased circulation time in the upper limb reduces the lag time of the finger pulse oximeter response
    • Ding Z.N., Shibata K., Yamamoto K., Kobayashi T., Murakami S. Decreased circulation time in the upper limb reduces the lag time of the finger pulse oximeter response. Can J Anaesth. 39:1992;87-89.
    • (1992) Can J Anaesth , vol.39 , pp. 87-89
    • Ding, Z.N.1    Shibata, K.2    Yamamoto, K.3    Kobayashi, T.4    Murakami, S.5
  • 6
    • 0029922024 scopus 로고    scopus 로고
    • Accuracy of pulse oximetry in hypothermic neonates and infants undergoing cardiac surgery
    • Iyer P., McDougall P., Loughnan P., Mee R.B., Al-Tawil K., Carlin J. Accuracy of pulse oximetry in hypothermic neonates and infants undergoing cardiac surgery. Crit Care Med. 24:1996;507-511.
    • (1996) Crit Care Med , vol.24 , pp. 507-511
    • Iyer, P.1    McDougall, P.2    Loughnan, P.3    Mee, R.B.4    Al-Tawil, K.5    Carlin, J.6
  • 7
    • 0024988847 scopus 로고
    • Comparison of four pulse oximeters: Effects of venous occlusion and cold-induced peripheral vasoconstriction
    • Langton J.A., Lassey D., Hanning C.D. Comparison of four pulse oximeters effects of venous occlusion and cold-induced peripheral vasoconstriction . Br J Anaesth. 65:1990;245-247.
    • (1990) Br J Anaesth , vol.65 , pp. 245-247
    • Langton, J.A.1    Lassey, D.2    Hanning, C.D.3
  • 8
    • 0027153273 scopus 로고
    • Pulse oximeter waveforms from the finger and toe during lumbar epidural anesthesia
    • Mineo R., Sharrock N.E. Pulse oximeter waveforms from the finger and toe during lumbar epidural anesthesia. Reg Anesth. 18:1993;106-109.
    • (1993) Reg Anesth , vol.18 , pp. 106-109
    • Mineo, R.1    Sharrock, N.E.2
  • 9
    • 0025813376 scopus 로고
    • Minimum pulse pressure and peripheral temperature needed for pulse oximetry during cardiac surgery with cardiopulmonary bypass
    • Palve H., Vuori A. Minimum pulse pressure and peripheral temperature needed for pulse oximetry during cardiac surgery with cardiopulmonary bypass. J Cardiothorac Vasc Anesth. 5:1991;327-330.
    • (1991) J Cardiothorac Vasc Anesth , vol.5 , pp. 327-330
    • Palve, H.1    Vuori, A.2
  • 10
    • 0024533898 scopus 로고
    • Pulse oximetry during low cardiac output and hypothermia states immediately after open heart surgery
    • Palve H., Vuori A. Pulse oximetry during low cardiac output and hypothermia states immediately after open heart surgery. Crit Care Med. 17:1989;66-69.
    • (1989) Crit Care Med , vol.17 , pp. 66-69
    • Palve, H.1    Vuori, A.2
  • 11
    • 0031040217 scopus 로고    scopus 로고
    • Accuracy of pulse oximetry in patients with low systemic vascular resistance
    • Secker C., Spiers P. Accuracy of pulse oximetry in patients with low systemic vascular resistance. Anaesthesia. 52:1997;127-130.
    • (1997) Anaesthesia , vol.52 , pp. 127-130
    • Secker, C.1    Spiers, P.2
  • 12
    • 0026535794 scopus 로고
    • The influence of changes in blood flow on the accuracy of pulse oximetry in humans
    • Vegfors M., Lindberg L.G., Lennmarken C. The influence of changes in blood flow on the accuracy of pulse oximetry in humans. Acta Anaesthesiol Scand. 36:1992;346-349.
    • (1992) Acta Anaesthesiol Scand , vol.36 , pp. 346-349
    • Vegfors, M.1    Lindberg, L.G.2    Lennmarken, C.3
  • 13
    • 0025270124 scopus 로고
    • Adverse respiratory events in anesthesia: A closed claims analysis
    • Caplan R.A., Posner K.L., Ward R.J., Cheney F.W. Adverse respiratory events in anesthesia a closed claims analysis . Anesthesiology. 72:1990;828-833.
    • (1990) Anesthesiology , vol.72 , pp. 828-833
    • Caplan, R.A.1    Posner, K.L.2    Ward, R.J.3    Cheney, F.W.4
  • 15
    • 0028537514 scopus 로고
    • Anesthesia related hypoxemia. The effect of pulse oximetry monitoring on perioperative events and postoperative complications
    • Moller J.T. Anesthesia related hypoxemia. The effect of pulse oximetry monitoring on perioperative events and postoperative complications. Dan Med Bull. 41:1994;489-500.
    • (1994) Dan Med Bull , vol.41 , pp. 489-500
    • Moller, J.T.1
  • 16
    • 0018843021 scopus 로고
    • Circulatory adjustments to hypoxia
    • Heistad D.D., Abboud F.M. Circulatory adjustments to hypoxia. Circulation. 61:1980;463-470.
    • (1980) Circulation , vol.61 , pp. 463-470
    • Heistad, D.D.1    Abboud, F.M.2
  • 17
    • 0024512498 scopus 로고
    • Comparison of pulse oximeters: Effects of vasoconstriction and venous engorgement
    • Wilkins C.J., Moores M., Hanning C.D. Comparison of pulse oximeters effects of vasoconstriction and venous engorgement . Br J Anaesth. 62:1989;439-444.
    • (1989) Br J Anaesth , vol.62 , pp. 439-444
    • Wilkins, C.J.1    Moores, M.2    Hanning, C.D.3
  • 18
    • 0023227243 scopus 로고
    • Evaluation of the Ohmeda 3700 pulse oximeter: Steady-state and transient response characteristics
    • Kagle D.M., Alexander C.M., Berko R.S., Giuffre M., Gross J.B. Evaluation of the Ohmeda 3700 pulse oximeter steady-state and transient response characteristics . Anesthesiology. 66:1987;376-380.
    • (1987) Anesthesiology , vol.66 , pp. 376-380
    • Kagle, D.M.1    Alexander, C.M.2    Berko, R.S.3    Giuffre, M.4    Gross, J.B.5
  • 19
    • 0023625841 scopus 로고
    • Evaluation of the Ohmeda 3700 pulse oximeter
    • Warley A.R., Mitchell J.H., Stradling J.R. Evaluation of the Ohmeda 3700 pulse oximeter. Thorax. 42:1987;892-896.
    • (1987) Thorax , vol.42 , pp. 892-896
    • Warley, A.R.1    Mitchell, J.H.2    Stradling, J.R.3
  • 20
    • 0023549911 scopus 로고
    • Accuracy of response of six pulse oximeters to profound hypoxia
    • Severinghaus J.W., Naifeh K.H. Accuracy of response of six pulse oximeters to profound hypoxia. Anesthesiology. 67:1987;551-558.
    • (1987) Anesthesiology , vol.67 , pp. 551-558
    • Severinghaus, J.W.1    Naifeh, K.H.2
  • 21
    • 0024506332 scopus 로고
    • Errors in 14 pulse oximeters during profound hypoxia
    • Severinghaus J.W., Naifeh K.H., Koh S.O. Errors in 14 pulse oximeters during profound hypoxia. J Clin Monit. 5:1989;72-81.
    • (1989) J Clin Monit , vol.5 , pp. 72-81
    • Severinghaus, J.W.1    Naifeh, K.H.2    Koh, S.O.3
  • 24
    • 0030963616 scopus 로고    scopus 로고
    • The hypoxic response: Huffing and HIFing
    • Guillemin K., Krasnow M.A. The hypoxic response Huffing and HIFing . Cell. 89:1997;9-12.
    • (1997) Cell , vol.89 , pp. 9-12
    • Guillemin, K.1    Krasnow, M.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.