메뉴 건너뛰기




Volumn 48, Issue 7, 2003, Pages 677-680

Does ambient light affect the accuracy of pulse oximetry?

Author keywords

Monitoring; Oxyhemoglobin saturation; Patient assessment; Pulse oximetry

Indexed keywords

OXYHEMOGLOBIN;

EID: 0642275551     PISSN: 00201324     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (47)

References (17)
  • 1
    • 0026300053 scopus 로고
    • AARC Clinical Practice Guideline: Pulse oximetry
    • American Association for Respiratory Care
    • American Association for Respiratory Care. AARC Clinical Practice Guideline: Pulse oximetry. Respir Care 1991;36(12):1406-1409.
    • (1991) Respir Care , vol.36 , Issue.12 , pp. 1406-1409
  • 2
    • 0024346442 scopus 로고
    • Pulse oximetry: A review of the theory, accuracy, and clinical applications
    • Bowes WA 3rd, Corke BC, Hulka J. Pulse oximetry: a review of the theory, accuracy, and clinical applications. Obstet Gynecol 1989;74(3 Pt 2):541-546.
    • (1989) Obstet Gynecol , vol.74 , Issue.3 PART 2 , pp. 541-546
    • Bowes 3rd, W.A.1    Corke, B.C.2    Hulka, J.3
  • 3
    • 84939471810 scopus 로고    scopus 로고
    • Scanlan CL. Analysis and monitoring of gas exchange. In: Scanlan CL, Wilkins RL, Stoller JK. Egan's fundamentals of respiratory care, 7th edition. St Louis: Mosby; 1999:337-369.
    • Scanlan CL. Analysis and monitoring of gas exchange. In: Scanlan CL, Wilkins RL, Stoller JK. Egan's fundamentals of respiratory care, 7th edition. St Louis: Mosby; 1999:337-369.
  • 4
    • 0026100834 scopus 로고
    • Potential errors in pulse oximetry. III: Effects of interferences, dyes, dyshaemoglobins and other pigments
    • Ralston AC, Webb RK, Runciman WB. Potential errors in pulse oximetry. III: Effects of interferences, dyes, dyshaemoglobins and other pigments. Anaesthesia 1991;46(4):291-295.
    • (1991) Anaesthesia , vol.46 , Issue.4 , pp. 291-295
    • Ralston, A.C.1    Webb, R.K.2    Runciman, W.B.3
  • 5
    • 84939470622 scopus 로고    scopus 로고
    • Mallinckrodt Inc. Operator's manual- N-395 pulse oximeter. St Louis 2000:25, 73.
    • Mallinckrodt Inc. Operator's manual- N-395 pulse oximeter. St Louis 2000:25, 73.
  • 7
    • 0032932450 scopus 로고    scopus 로고
    • Pulse oximetry: Principles and limitations
    • Sinex JE. Pulse oximetry: principles and limitations. Am J Emerg Med 1999;17(1):59-67.
    • (1999) Am J Emerg Med , vol.17 , Issue.1 , pp. 59-67
    • Sinex, J.E.1
  • 9
    • 0023885793 scopus 로고
    • Noninvasive oxygen monitoring
    • Brown M, Vender JS. Noninvasive oxygen monitoring. Crit Care Clin 1988;4(3):493-509.
    • (1988) Crit Care Clin , vol.4 , Issue.3 , pp. 493-509
    • Brown, M.1    Vender, J.S.2
  • 10
    • 0025306525 scopus 로고
    • Pulse oximetry: Instrumentation and clinical applications
    • discussion 597-601
    • Welch JP, DeCesare R, Hess D. Pulse oximetry: instrumentation and clinical applications. Respir Care 1990;35(6):584-597; discussion 597-601.
    • (1990) Respir Care , vol.35 , Issue.6 , pp. 584-597
    • Welch, J.P.1    DeCesare, R.2    Hess, D.3
  • 11
    • 0024375160 scopus 로고
    • Skin color and ear oximetry
    • Ries AL, Prewitt LM, Johnson JJ. Skin color and ear oximetry. Chest 1989;96(2):287-290.
    • (1989) Chest , vol.96 , Issue.2 , pp. 287-290
    • Ries, A.L.1    Prewitt, L.M.2    Johnson, J.J.3
  • 13
    • 0030989206 scopus 로고    scopus 로고
    • Effects of motion, ambient light, and hypoperfusion on pulse oximeter function
    • Trivedi NS, Ghouri AF, Shah NK, Lai E, Barker SJ. Effects of motion, ambient light, and hypoperfusion on pulse oximeter function. J Clin Anesth 1997;9(3):179-183.
    • (1997) J Clin Anesth , vol.9 , Issue.3 , pp. 179-183
    • Trivedi, N.S.1    Ghouri, A.F.2    Shah, N.K.3    Lai, E.4    Barker, S.J.5
  • 14
    • 0024511902 scopus 로고
    • Fluorescent light interferes with pulse oximetry
    • Amar D, Neidzwski J, Wald A, Finck AD. Fluorescent light interferes with pulse oximetry. J Clin Monit 1989;5(2):135-136.
    • (1989) J Clin Monit , vol.5 , Issue.2 , pp. 135-136
    • Amar, D.1    Neidzwski, J.2    Wald, A.3    Finck, A.D.4
  • 15
    • 0023395659 scopus 로고    scopus 로고
    • Preventing ambient light from affecting pulse oximetry (letter)
    • Siegel MN, Gravenstein N. Preventing ambient light from affecting pulse oximetry (letter). Anesthesiology 1998;67(2):280.
    • (1998) Anesthesiology , vol.67 , Issue.2 , pp. 280
    • Siegel, M.N.1    Gravenstein, N.2
  • 16
    • 0023264568 scopus 로고
    • Interference in a pulse oximeter from a fiberoptic light source
    • Block FE Jr. Interference in a pulse oximeter from a fiberoptic light source. J Clin Monit 1987;3(3):210-211.
    • (1987) J Clin Monit , vol.3 , Issue.3 , pp. 210-211
    • Block Jr., F.E.1
  • 17
    • 0021522916 scopus 로고
    • Infrared heat lamps interfere with pulse oximeters (letter)
    • Brooks TD, Paulus DA, Winkle WE. Infrared heat lamps interfere with pulse oximeters (letter). Anesthesiology 1984;61(5):630.
    • (1984) Anesthesiology , vol.61 , Issue.5 , pp. 630
    • Brooks, T.D.1    Paulus, D.A.2    Winkle, W.E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.