메뉴 건너뛰기




Volumn 24, Issue 4, 2014, Pages 799-806

Quantitative analysis of emphysema and airway measurements according to iterative reconstruction algorithms: Comparison of filtered back projection, adaptive statistical iterative reconstruction and model-based iterative reconstruction

Author keywords

Chronic obstructive pulmonary disease; Computed tomography; Iterative reconstruction; Pulmonary emphysema; Quantitative analysis

Indexed keywords

ADAPTIVE STATISTICAL ITERATIVE RECONSTRUCTION; ADULT; AGED; AIRWAY; ALGORITHM; ARTICLE; CHRONIC OBSTRUCTIVE LUNG DISEASE; COMPARATIVE STUDY; COMPUTER ASSISTED TOMOGRAPHY; EMPHYSEMA; FEMALE; FILTERED BACK PROJECTION; HUMAN; LUNG EMPHYSEMA; LUNG PARENCHYMA; MAJOR CLINICAL STUDY; MALE; MEASUREMENT ERROR; MIDDLE AGED; MODEL BASED ITERATIVE RECONSTRUCTION; PRIORITY JOURNAL; QUANTITATIVE ANALYSIS; RADIOLOGICAL PARAMETERS; RADIOLOGY PHANTOM; THICKNESS; TOTAL LUNG CAPACITY; VERY ELDERLY; WILCOXON SIGNED RANKS TEST; YOUNG ADULT;

EID: 84896313470     PISSN: 09387994     EISSN: 14321084     Source Type: Journal    
DOI: 10.1007/s00330-013-3078-5     Document Type: Article
Times cited : (46)

References (28)
  • 1
    • 70349571729 scopus 로고    scopus 로고
    • Radiation dose modulation techniques in the multidetector CT era: From basics to practice
    • Lee CH, Goo JM, Ye HJ et al (2008) Radiation dose modulation techniques in the multidetector CT era: from basics to practice. Radiographics 28:1451-1459
    • (2008) Radiographics , vol.28 , pp. 1451-1459
    • Lee, C.H.1    Goo, J.M.2    Ye, H.J.3
  • 2
    • 77957551489 scopus 로고    scopus 로고
    • Impact of new technologies on dose reduction in CT
    • Lee TY, Chhem RK (2010) Impact of new technologies on dose reduction in CT. Eur J Radiol 76:28-35
    • (2010) Eur J Radiol , vol.76 , pp. 28-35
    • Lee, T.Y.1    Chhem, R.K.2
  • 3
    • 77956841482 scopus 로고    scopus 로고
    • Abdominal CT: Comparison of low-dose CTwith adaptive statistical iterative reconstruction and routine-dose CT with filtered back projection in 53 patients
    • Sagara Y, Hara AK, Pavlicek W, Silva AC, Paden RG, Wu Q (2010) Abdominal CT: comparison of low-dose CTwith adaptive statistical iterative reconstruction and routine-dose CT with filtered back projection in 53 patients. AJR Am J Roentgenol 195:713-719
    • (2010) AJR Am J Roentgenol , vol.195 , pp. 713-719
    • Sagara, Y.1    Hara, A.K.2    Pavlicek, W.3    Silva, A.C.4    Paden, R.G.5    Wu, Q.6
  • 4
    • 84864713607 scopus 로고    scopus 로고
    • Model-based iterative reconstruction technique for radiation dose reduction in chest CT: Comparison with the adaptive statistical iterative reconstruction technique
    • Katsura M, Matsuda I, Akahane M et al (2012) Model-based iterative reconstruction technique for radiation dose reduction in chest CT: comparison with the adaptive statistical iterative reconstruction technique. Eur Radiol 22:1613-1623
    • (2012) Eur Radiol , vol.22 , pp. 1613-1623
    • Katsura, M.1    Matsuda, I.2    Akahane, M.3
  • 6
    • 84856855191 scopus 로고    scopus 로고
    • Adaptive statistical iterative reconstruction versus filtered back projection in the same patient: 64 channel liver CT image quality and patient radiation dose
    • Mitsumori LM, Shuman WP, Busey JM, Kolokythas O, Koprowicz KM(2012) Adaptive statistical iterative reconstruction versus filtered back projection in the same patient: 64 channel liver CT image quality and patient radiation dose. Eur Radiol 22:138-143
    • (2012) Eur Radiol , vol.22 , pp. 138-143
    • Mitsumori, L.M.1    Shuman, W.P.2    Busey, J.M.3    Kolokythas, O.4    Koprowicz, K.M.5
  • 7
    • 76449091107 scopus 로고    scopus 로고
    • Radiation dose reduction with chest computed tomography using adaptive statistical iterative reconstruction technique: Initial experience
    • Prakash P, Kalra MK, Digumarthy SR et al (2010) Radiation dose reduction with chest computed tomography using adaptive statistical iterative reconstruction technique: initial experience. J Comput Assist Tomogr 34:40-45
    • (2010) J Comput Assist Tomogr , vol.34 , pp. 40-45
    • Prakash, P.1    Kalra, M.K.2    Digumarthy, S.R.3
  • 8
    • 74749087439 scopus 로고    scopus 로고
    • Innovations in CT dose reduction strategy: Application of the adaptive statistical iterative reconstruction algorithm
    • Silva AC, Lawder HJ, Hara A, Kujak J, Pavlicek W (2010) Innovations in CT dose reduction strategy: application of the adaptive statistical iterative reconstruction algorithm. AJR Am J Roentgenol 194:191-199
    • (2010) AJR Am J Roentgenol , vol.194 , pp. 191-199
    • Silva, A.C.1    Lawder, H.J.2    Hara, A.3    Kujak, J.4    Pavlicek, W.5
  • 9
    • 84863666413 scopus 로고    scopus 로고
    • Model-based iterative reconstruction technique for ultralow-dose computed tomography of the lung: A pilot study
    • Yamada Y, Jinzaki M, Tanami Y et al (2012) Model-based iterative reconstruction technique for ultralow-dose computed tomography of the lung: a pilot study. Invest Radiol 47:482-489
    • (2012) Invest Radiol , vol.47 , pp. 482-489
    • Yamada, Y.1    Jinzaki, M.2    Tanami, Y.3
  • 10
    • 84867241562 scopus 로고    scopus 로고
    • Morphological measurements in computed tomography correlate with airflow obstruction in chronic obstructive pulmonary disease: Systematic review and meta-analysis
    • Xie X, de Jong PA, Oudkerk M et al (2012) Morphological measurements in computed tomography correlate with airflow obstruction in chronic obstructive pulmonary disease: systematic review and meta-analysis. Eur Radiol 22:2085-2093
    • (2012) Eur Radiol , vol.22 , pp. 2085-2093
    • Xie, X.1    De Jong, P.A.2    Oudkerk, M.3
  • 11
    • 84878347675 scopus 로고    scopus 로고
    • Quantitative thoracic CT techniques in adults: Can they be applied in the pediatric population?
    • Yoon SH, Goo JM, Goo HW (2013) Quantitative thoracic CT techniques in adults: can they be applied in the pediatric population? Pediatr Radiol 43:308-314
    • (2013) Pediatr Radiol , vol.43 , pp. 308-314
    • Yoon, S.H.1    Goo, J.M.2    Goo, H.W.3
  • 13
    • 73049095694 scopus 로고    scopus 로고
    • Effects of CT section thickness and reconstruction kernel on emphysema quantification relationship to the magnitude of the CT emphysema index
    • Gierada DS, Bierhals AJ, Choong CK et al (2010) Effects of CT section thickness and reconstruction kernel on emphysema quantification relationship to the magnitude of the CT emphysema index. Acad Radiol 17:146-156
    • (2010) Acad Radiol , vol.17 , pp. 146-156
    • Gierada, D.S.1    Bierhals, A.J.2    Choong, C.K.3
  • 14
    • 84858276535 scopus 로고    scopus 로고
    • Inter-scan repeatability of CT-based lung densitometry in the surveillance of emphysema in a lung cancer screening setting
    • Park SJ, Lee CH, Goo JM, Heo CY, Kim JH (2012) Inter-scan repeatability of CT-based lung densitometry in the surveillance of emphysema in a lung cancer screening setting. Eur J Radiol 81:e554-e560
    • (2012) Eur J Radiol , vol.81
    • Park, S.J.1    Lee, C.H.2    Goo, J.M.3    Heo, C.Y.4    Kim, J.H.5
  • 15
    • 84867266066 scopus 로고    scopus 로고
    • The effect of iterative reconstruction on computed tomography assessment of emphysema, air trapping and airway dimensions
    • Mets OM, Willemink MJ, de Kort FP et al (2012) The effect of iterative reconstruction on computed tomography assessment of emphysema, air trapping and airway dimensions. Eur Radiol 22:2103-2109
    • (2012) Eur Radiol , vol.22 , pp. 2103-2109
    • Mets, O.M.1    Willemink, M.J.2    De Kort, F.P.3
  • 16
    • 84865589993 scopus 로고    scopus 로고
    • Emphysema quantification by low-dose CT: Potential impact of adaptive iterative dose reduction using 3D processing
    • Nishio M, Matsumoto S, Ohno Y et al (2012) Emphysema quantification by low-dose CT: potential impact of adaptive iterative dose reduction using 3D processing. AJR Am J Roentgenol 199:595-601
    • (2012) AJR Am J Roentgenol , vol.199 , pp. 595-601
    • Nishio, M.1    Matsumoto, S.2    Ohno, Y.3
  • 18
    • 79955036642 scopus 로고    scopus 로고
    • Adaptive statistical iterative reconstruction technique for radiation dose reduction in chest CT: A pilot study
    • Singh S, Kalra MK, Gilman MD et al (2011) Adaptive statistical iterative reconstruction technique for radiation dose reduction in chest CT: a pilot study. Radiology 259:565-573
    • (2011) Radiology , vol.259 , pp. 565-573
    • Singh, S.1    Kalra, M.K.2    Gilman, M.D.3
  • 19
    • 79957914848 scopus 로고    scopus 로고
    • Cross-sectional analysis of the utility of pulmonary function tests in predicting emphysema in ever-smokers
    • Hesselbacher SE, Ross R, Schabath MB et al (2011) Cross-sectional analysis of the utility of pulmonary function tests in predicting emphysema in ever-smokers. Int J Environ Res Public Health 8:1324-1340
    • (2011) Int J Environ Res Public Health , vol.8 , pp. 1324-1340
    • Hesselbacher, S.E.1    Ross, R.2    Schabath, M.B.3
  • 21
    • 0025101237 scopus 로고
    • Quantitation of emphysema by computed tomography using a 'density mask' program and correlation with pulmonary function tests
    • Kinsella M, Müller NL, Abboud RT, Morrison NJ, DyBuncio A (1990) Quantitation of emphysema by computed tomography using a "density mask" program and correlation with pulmonary function tests. Chest 97:315-321 (Pubitemid 20050666)
    • (1990) Chest , vol.97 , Issue.2 , pp. 315-321
    • Kinsella, M.1    Muller, N.L.2    Abboud, R.T.3    Morrison, N.J.4    DyBuncio, A.5
  • 24
    • 34548033498 scopus 로고    scopus 로고
    • The effects of radiation dose and CT manufacturer on measurements of lung densitometry
    • DOI 10.1378/chest.06-2325
    • Yuan R, Mayo JR, Hogg JC et al (2007) The effects of radiation dose and CT manufacturer on measurements of lung densitometry. Chest 132:617-623 (Pubitemid 47282397)
    • (2007) Chest , vol.132 , Issue.2 , pp. 617-623
    • Yuan, R.1    Mayo, J.R.2    Hogg, J.C.3    Pare, P.D.4    McWilliams, A.M.5    Lam, S.6    Coxson, H.O.7
  • 25
    • 0033043753 scopus 로고    scopus 로고
    • Quantitation of emphysema with three-dimensional CT densitometry: Comparison with two-dimensional analysis, visual emphysema scores, and pulmonary function test results
    • Park KJ, Bergin CJ, Clausen JL (1999) Quantitation of emphysema with three-dimensional CT densitometry: comparison with two-dimensional analysis, visual emphysema scores, and pulmonary function test results. Radiology 211:541-547 (Pubitemid 29206828)
    • (1999) Radiology , vol.211 , Issue.2 , pp. 541-547
    • Park, K.J.1    Bergin, C.J.2    Clausen, J.L.3
  • 26
    • 80755163509 scopus 로고    scopus 로고
    • How accurate is CT morphometry of airway? Phantomand clinical validation study
    • Takahashi M, Okada H, Oguni N et al (2011) How accurate is CT morphometry of airway? Phantomand clinical validation study. Eur J Radiol 80:e524-e530
    • (2011) Eur J Radiol , vol.80
    • Takahashi, M.1    Okada, H.2    Oguni, N.3
  • 27
    • 80052671827 scopus 로고    scopus 로고
    • The role of CT scanning in multidimensional phenotyping of COPD
    • Bafadhel M, Umar I, Gupta S et al (2011) The role of CT scanning in multidimensional phenotyping of COPD. Chest 140:634-642
    • (2011) Chest , vol.140 , pp. 634-642
    • Bafadhel, M.1    Umar, I.2    Gupta, S.3
  • 28
    • 34147202921 scopus 로고    scopus 로고
    • Pulmonary emphysema: Radiation dose and section thickness at multidetector CT quantification - Comparison with macroscopic and microscopic morphometry
    • DOI 10.1148/radiol.2431060194
    • Madani A, De Maertelaer V, Zanen J, Gevenois PA (2007) Pulmonary emphysema: radiation dose and section thickness at multidetector CT quantification - comparison with macroscopic and microscopic morphometry. Radiology 243:250-257 (Pubitemid 46579717)
    • (2007) Radiology , vol.243 , Issue.1 , pp. 250-257
    • Madani, A.1    De Maertelaer, V.2    Zanen, J.3    Gevenois, P.A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.