메뉴 건너뛰기




Volumn 232, Issue 1, 2004, Pages 295-301

Emphysema: Effect of reconstruction algorithm on CT imaging measures

Author keywords

Computed tomography (CT), computer programs; Computed tomography (CT), electron beam; Computed tomography (CT), image processing; Emphysema, pulmonary; Lung, CT

Indexed keywords

ADULT; AGED; ALGORITHM; ARTICLE; CLINICAL ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; FEMALE; HUMAN; IMAGE ANALYSIS; IMAGE ENHANCEMENT; IMAGE RECONSTRUCTION; LUNG EMPHYSEMA; MALE; PRIORITY JOURNAL; STATISTICAL ANALYSIS;

EID: 2942752080     PISSN: 00338419     EISSN: None     Source Type: Journal    
DOI: 10.1148/radiol.2321030383     Document Type: Article
Times cited : (173)

References (20)
  • 1
    • 0036141583 scopus 로고    scopus 로고
    • Quantitative CT of the lung
    • Goldin JG. Quantitative CT of the lung. Radiol Clin North Am 2002; 40:145-162.
    • (2002) Radiol Clin North Am , vol.40 , pp. 145-162
    • Goldin, J.G.1
  • 2
    • 0034764145 scopus 로고    scopus 로고
    • Repeatability of lung density measurements with low-dose computed tomography in subjects with alpha-1-antitrypsin deficiency-associated emphysema
    • Stolk J, Dirksen A, van der Lugt AA, et al. Repeatability of lung density measurements with low-dose computed tomography in subjects with alpha-1-antitrypsin deficiency-associated emphysema. Invest Radiol 2001; 36:648-651.
    • (2001) Invest Radiol , vol.36 , pp. 648-651
    • Stolk, J.1    Dirksen, A.2    Van Der Lugt, A.A.3
  • 5
    • 0031473144 scopus 로고    scopus 로고
    • CT lung densitometry: Dependence of CT number histograms on sample volume and consequences for scan protocol comparability
    • Kemerink GJ, Kruize HH, Lamers RJ, van Engelshoven JM. CT lung densitometry: dependence of CT number histograms on sample volume and consequences for scan protocol comparability. J Comput Assist Tomogr 1997; 21:948-954.
    • (1997) J Comput Assist Tomogr , vol.21 , pp. 948-954
    • Kemerink, G.J.1    Kruize, H.H.2    Lamers, R.J.3    Van Engelshoven, J.M.4
  • 6
    • 0023695782 scopus 로고
    • Density mask: An objective method to quantitate emphysema using computed tomography
    • Muller NL, Miller RR, Abboud RT. Density mask: an objective method to quantitate emphysema using computed tomography. Chest 1988; 94:782-787.
    • (1988) Chest , vol.94 , pp. 782-787
    • Muller, N.L.1    Miller, R.R.2    Abboud, R.T.3
  • 7
    • 0033057034 scopus 로고    scopus 로고
    • A quantification of the lung surface area in emphysema using computed tomography
    • Coxson HO, Rogers RM, Hogg JC, et al. A quantification of the lung surface area in emphysema using computed tomography [published correction appears in Am J Respir Crit Care Med 2001; 163:1500-1501]. Am J Respir Crit Care Med, 1999; 159:851-956.
    • (1999) Am J Respir Crit Care Med , vol.159 , pp. 851-956
    • Coxson, H.O.1    Rogers, R.M.2    Hogg, J.C.3
  • 8
    • 0034981871 scopus 로고    scopus 로고
    • published correction appears
    • Coxson HO, Rogers RM, Hogg JC, et al. A quantification of the lung surface area in emphysema using computed tomography [published correction appears in Am J Respir Crit Care Med 2001; 163:1500-1501]. Am J Respir Crit Care Med, 1999; 159:851-956.
    • (2001) Am J Respir Crit Care Med , vol.163 , pp. 1500-1501
  • 9
    • 0019913387 scopus 로고
    • A practical method to measure the MTF of CT scanners
    • Droege RT, Morin RL. A practical method to measure the MTF of CT scanners. Med Phys 1982; 9:758-760.
    • (1982) Med Phys , vol.9 , pp. 758-760
    • Droege, R.T.1    Morin, R.L.2
  • 10
    • 0035080793 scopus 로고    scopus 로고
    • Determination of the presampled MTF in computed tomography
    • Boone JM. Determination of the presampled MTF in computed tomography. Med Phys 2001; 28:356-360.
    • (2001) Med Phys , vol.28 , pp. 356-360
    • Boone, J.M.1
  • 11
    • 0031283426 scopus 로고    scopus 로고
    • Method for segmenting chest CT image data using an anatomical model: Preliminary results
    • Brown MS, McNitt-Gray MF, Mankovich NJ, et al. Method for segmenting chest CT image data using an anatomical model: preliminary results. IEEE Trans Med Imaging 1997; 16:828-839.
    • (1997) IEEE Trans Med Imaging , vol.16 , pp. 828-839
    • Brown, M.S.1    McNitt-Gray, M.F.2    Mankovich, N.J.3
  • 12
    • 0034023312 scopus 로고    scopus 로고
    • Knowledge-based segmentation of thoracic computed tomography images for assessment of split lung function
    • Brown MS, Goldin JG, McNitt-Gray MF, et al. Knowledge-based segmentation of thoracic computed tomography images for assessment of split lung function. Med Phys 2000; 27:592-598.
    • (2000) Med Phys , vol.27 , pp. 592-598
    • Brown, M.S.1    Goldin, J.G.2    McNitt-Gray, M.F.3
  • 13
    • 0032767425 scopus 로고    scopus 로고
    • Automated measurement of single and total lung volume from CT
    • Brown MS, McNitt-Gray MF, Goldin JG, et al. Automated measurement of single and total lung volume from CT. J Comput Assist Tomogr 1999; 23:632-640.
    • (1999) J Comput Assist Tomogr , vol.23 , pp. 632-640
    • Brown, M.S.1    McNitt-Gray, M.F.2    Goldin, J.G.3
  • 14
    • 0000250624 scopus 로고
    • The behavior of maximum likelihood estimates under non-standard conditions
    • Berkeley, Calif: University of California Press
    • Huber PJ. The behavior of maximum likelihood estimates under non-standard conditions. In: Proceedings of the Fifth Berkeley Symposium on Mathematical Statistics and Probability. Vol 1. Berkeley, Calif: University of California Press, 1967; 221-233.
    • (1967) Proceedings of the Fifth Berkeley Symposium on Mathematical Statistics and Probability , vol.1 , pp. 221-233
    • Huber, P.J.1
  • 15
    • 0000095552 scopus 로고
    • A heteroskedasticity-consistent covariance matrix estimator and a direct test for heteroskedasticity
    • White H. A heteroskedasticity-consistent covariance matrix estimator and a direct test for heteroskedasticity. Econometrica 1980; 48:817-830.
    • (1980) Econometrica , vol.48 , pp. 817-830
    • White, H.1
  • 17
    • 8244229859 scopus 로고    scopus 로고
    • Quantification of idiopathic pulmonary fibrosis using computed tomography and histology
    • Coxson HO, Hogg JC, Mayo JR, et al. Quantification of idiopathic pulmonary fibrosis using computed tomography and histology. Am J Respir Crit Care Med 1997; 155:1649-1656.
    • (1997) Am J Respir Crit Care Med , vol.155 , pp. 1649-1656
    • Coxson, H.O.1    Hogg, J.C.2    Mayo, J.R.3
  • 19
    • 0029021066 scopus 로고
    • Can computed tomography quantify pulmonary emphysema?
    • Gevenois PA, Yernault JC. Can computed tomography quantify pulmonary emphysema? Eur Respir J 1995; 8:843-848.
    • (1995) Eur Respir J , vol.8 , pp. 843-848
    • Gevenois, P.A.1    Yernault, J.C.2
  • 20
    • 0022559799 scopus 로고
    • The diagnosis of emphysema: A computed tomographic-pathologic correlation
    • Bergin C, Muller N, Nichols DM, et al. The diagnosis of emphysema: a computed tomographic-pathologic correlation. Am Rev Respir Dis 1986; 133:541-546.
    • (1986) Am Rev Respir Dis , vol.133 , pp. 541-546
    • Bergin, C.1    Muller, N.2    Nichols, D.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.