-
1
-
-
84859718633
-
The value of translational models for microvascular anastamosis
-
J. Russin, and S.L. Giannotta The value of translational models for microvascular anastamosis World Neurosurg 77 2012 289 290
-
(2012)
World Neurosurg
, vol.77
, pp. 289-290
-
-
Russin, J.1
Giannotta, S.L.2
-
2
-
-
0037132877
-
Effect of visual-spatial ability on learning of spatially-complex surgical skills
-
K.R. Wanzel, S.J. Hamstra, and D.J. Anastakis et al. Effect of visual-spatial ability on learning of spatially-complex surgical skills Lancet 359 2002 230 231
-
(2002)
Lancet
, vol.359
, pp. 230-231
-
-
Wanzel, K.R.1
Hamstra, S.J.2
Anastakis, D.J.3
-
3
-
-
0024400613
-
Use of small-caliber polytetrafluoroethylene (Gore-Tex) grafts in microsurgical training
-
K.E. Korber, and B.A. Kraemer Use of small-caliber polytetrafluoroethylene (Gore-Tex) grafts in microsurgical training Microsurgery 10 1989 113 115
-
(1989)
Microsurgery
, vol.10
, pp. 113-115
-
-
Korber, K.E.1
Kraemer, B.A.2
-
4
-
-
0022548017
-
An animal model for advanced microsurgical training
-
B.L. Eppley, and J.J. Delfino An animal model for advanced microsurgical training J Oral Maxillofac Surg 44 1986 833 836
-
(1986)
J Oral Maxillofac Surg
, vol.44
, pp. 833-836
-
-
Eppley, B.L.1
Delfino, J.J.2
-
5
-
-
0021120013
-
A training card for microsurgery
-
A.M. Awwad A training card for microsurgery Microsurgery 5 1984 160
-
(1984)
Microsurgery
, vol.5
, pp. 160
-
-
Awwad, A.M.1
-
8
-
-
0019775384
-
Fresh chicken leg: An experimental model for the microsurgical beginner
-
D. Sucur, P. Konstantinovic, and Z. Potparic Fresh chicken leg: an experimental model for the microsurgical beginner Br J Plast Surg 34 1981 488 489
-
(1981)
Br J Plast Surg
, vol.34
, pp. 488-489
-
-
Sucur, D.1
Konstantinovic, P.2
Potparic, Z.3
-
9
-
-
0019785480
-
A simple model on which to practise microsurgical technique: A fresh chicken
-
A. Govila A simple model on which to practise microsurgical technique: a fresh chicken Br J Plast Surg 34 1981 486 487
-
(1981)
Br J Plast Surg
, vol.34
, pp. 486-487
-
-
Govila, A.1
-
10
-
-
0019253247
-
The microvascular technique of vein grafting in rats as a training and experimental model
-
R.M. Razaboni, D.L. Ballantyne, and A.D. Harper et al. The microvascular technique of vein grafting in rats as a training and experimental model J Microsurg 2 1980 148 150
-
(1980)
J Microsurg
, vol.2
, pp. 148-150
-
-
Razaboni, R.M.1
Ballantyne, D.L.2
Harper, A.D.3
-
11
-
-
0037941403
-
Training in microvascular surgery using a chicken wing artery
-
discussion 7-8
-
A. Hino Training in microvascular surgery using a chicken wing artery Neurosurgery 52 2003 1495 1497 discussion 7-8
-
(2003)
Neurosurgery
, vol.52
, pp. 1495-1497
-
-
Hino, A.1
-
12
-
-
77956220821
-
Novel brain model for training of deep microvascular anastomosis
-
T. Ishikawa, N. Yasui, and H. Ono Novel brain model for training of deep microvascular anastomosis Neurol Med Chir (Tokyo) 50 2010 627 629
-
(2010)
Neurol Med Chir (Tokyo)
, vol.50
, pp. 627-629
-
-
Ishikawa, T.1
Yasui, N.2
Ono, H.3
-
13
-
-
33645623934
-
Experimental microsurgical operations in animals
-
M.G. Yasargil, Georg Thieme Verlag Stuttgart, Germany
-
M.G. Yasargil Experimental microsurgical operations in animals M.G. Yasargil, Microsurgery applied to neurosurgery 1969 Georg Thieme Verlag Stuttgart, Germany 60 81
-
(1969)
Microsurgery Applied to Neurosurgery
, pp. 60-81
-
-
Yasargil, M.G.1
-
14
-
-
0026053753
-
Rat femoral vein-to-vein grafts as a microvascular practice model: Factors that influence patency
-
B.C. Cooley, M. Lan, and J.S. Gould Rat femoral vein-to-vein grafts as a microvascular practice model: factors that influence patency Microsurgery 12 1991 43 45
-
(1991)
Microsurgery
, vol.12
, pp. 43-45
-
-
Cooley, B.C.1
Lan, M.2
Gould, J.S.3
-
15
-
-
0028953527
-
Rat tail: A useful model for microvascular training
-
J.Y. Bao Rat tail: a useful model for microvascular training Microsurgery 16 1995 122 125
-
(1995)
Microsurgery
, vol.16
, pp. 122-125
-
-
Bao, J.Y.1
-
16
-
-
77952944099
-
Comparison of different microanastomosis training models: Model accuracy and practicality
-
G. Hwang, C.W. Oh, and S.Q. Park et al. Comparison of different microanastomosis training models: model accuracy and practicality J Korean Neurosurg Soc 47 2010 287 290
-
(2010)
J Korean Neurosurg Soc
, vol.47
, pp. 287-290
-
-
Hwang, G.1
Oh, C.W.2
Park, S.Q.3
-
17
-
-
60649084398
-
The realization of preferable operative working space through the microsurgical training with rats-the importance of the process
-
R. Kanazawa, and A. Teramoto The realization of preferable operative working space through the microsurgical training with rats-the importance of the process Surg Neurol 71 2009 380 387
-
(2009)
Surg Neurol
, vol.71
, pp. 380-387
-
-
Kanazawa, R.1
Teramoto, A.2
-
18
-
-
67549106788
-
Neurosurgical training: More hours needed or a new learning culture?
-
discussion 95-7
-
J. Haase, and E. Boisen Neurosurgical training: more hours needed or a new learning culture? Surg Neurol 72 2009 89 95 discussion 95-7
-
(2009)
Surg Neurol
, vol.72
, pp. 89-95
-
-
Haase, J.1
Boisen, E.2
-
19
-
-
13444269362
-
Microsurgical skills training: A new concept for simulation of vessel-wall suturing
-
A. Lahiri, A.Y. Lim, and Z. Qifen et al. Microsurgical skills training: a new concept for simulation of vessel-wall suturing Microsurgery 25 2005 21 24
-
(2005)
Microsurgery
, vol.25
, pp. 21-24
-
-
Lahiri, A.1
Lim, A.Y.2
Qifen, Z.3
-
20
-
-
0042972676
-
Microsurgical training with surgical gauze: The first step
-
M.E. Demirseren, Y. Tosa, and Y. Hosaka Microsurgical training with surgical gauze: the first step J Reconstr Microsurg 19 2003 385 386
-
(2003)
J Reconstr Microsurg
, vol.19
, pp. 385-386
-
-
Demirseren, M.E.1
Tosa, Y.2
Hosaka, Y.3
-
21
-
-
0036941016
-
Design of a new suture practice card for microsurgical training
-
J. Uson, and M.C. Calles Design of a new suture practice card for microsurgical training Microsurgery 22 2002 324 328
-
(2002)
Microsurgery
, vol.22
, pp. 324-328
-
-
Uson, J.1
Calles, M.C.2
-
22
-
-
0035491221
-
The PVC-rat and other alternatives in microsurgical training
-
R. Remie The PVC-rat and other alternatives in microsurgical training Lab Anim (NY) 30 2001 48 52
-
(2001)
Lab Anim (NY)
, vol.30
, pp. 48-52
-
-
Remie, R.1
-
23
-
-
0035678985
-
Non-vital, prosthetic, and virtual reality models of microsurgical training
-
D.A. Lannon, J.A. Atkins, and P.E. Butler Non-vital, prosthetic, and virtual reality models of microsurgical training Microsurgery 21 2001 389 393
-
(2001)
Microsurgery
, vol.21
, pp. 389-393
-
-
Lannon, D.A.1
Atkins, J.A.2
Butler, P.E.3
-
24
-
-
0035674543
-
Alternative model for teaching microsurgery
-
S.P. Fanua, J. Kim, and E.F. Shaw Wilgis Alternative model for teaching microsurgery Microsurgery 21 2001 379 382
-
(2001)
Microsurgery
, vol.21
, pp. 379-382
-
-
Fanua, S.P.1
Kim, J.2
Shaw Wilgis, E.F.3
-
25
-
-
0034495747
-
From surgical gloves to the rat. The various stages of microsurgery learning
-
A.G. Zarabini, and M. Galeano From surgical gloves to the rat. The various stages of microsurgery learning Minerva Chir 55 2000 687 692
-
(2000)
Minerva Chir
, vol.55
, pp. 687-692
-
-
Zarabini, A.G.1
Galeano, M.2
-
27
-
-
0032438584
-
Dexter: A device for the assessment of microsurgical instrumentation and instruction of trainees
-
S.J. Southern, and V. Ramakrishnan Dexter: a device for the assessment of microsurgical instrumentation and instruction of trainees Microsurgery 18 1998 430 431
-
(1998)
Microsurgery
, vol.18
, pp. 430-431
-
-
Southern, S.J.1
Ramakrishnan, V.2
-
28
-
-
0030923994
-
A synthetic model for microsurgical training: A surgical contribution to reduce the number of animal experiments
-
D. Weber, N. Moser, and R. Rosslein A synthetic model for microsurgical training: a surgical contribution to reduce the number of animal experiments Eur J Pediatr Surg 7 1997 204 206
-
(1997)
Eur J Pediatr Surg
, vol.7
, pp. 204-206
-
-
Weber, D.1
Moser, N.2
Rosslein, R.3
-
29
-
-
0029552606
-
New model for microsurgical training and skills maintenance
-
D.M. Yen, R. Arroyo, and R. Berezniak et al. New model for microsurgical training and skills maintenance Microsurgery 16 1995 760 762
-
(1995)
Microsurgery
, vol.16
, pp. 760-762
-
-
Yen, D.M.1
Arroyo, R.2
Berezniak, R.3
-
30
-
-
0029557930
-
Advanced non-animal microsurgical exercises
-
N.L. Crosby, J.B. Clapson, and H.J. Buncke et al. Advanced non-animal microsurgical exercises Microsurgery 16 1995 655 658
-
(1995)
Microsurgery
, vol.16
, pp. 655-658
-
-
Crosby, N.L.1
Clapson, J.B.2
Buncke, H.J.3
-
31
-
-
0025311289
-
Canniesburn "ever-ready" model to practise microsurgery
-
M.M. Guler, and G.S. Rao Canniesburn "ever-ready" model to practise microsurgery Br J Plast Surg 43 1990 381 382
-
(1990)
Br J Plast Surg
, vol.43
, pp. 381-382
-
-
Guler, M.M.1
Rao, G.S.2
-
32
-
-
0020955040
-
A microvascular surgical practice disc for beginners
-
S. Lee, and W.J. Coppersmith A microvascular surgical practice disc for beginners Microsurgery 4 1983 67 69
-
(1983)
Microsurgery
, vol.4
, pp. 67-69
-
-
Lee, S.1
Coppersmith, W.J.2
-
33
-
-
0037159724
-
Animal rights pressure on scientists
-
S.L. Teitelbaum Animal rights pressure on scientists Science 298 2002 1515
-
(2002)
Science
, vol.298
, pp. 1515
-
-
Teitelbaum, S.L.1
-
34
-
-
3242670638
-
The educational impact of bench model fidelity on the acquisition of technical skill: The use of clinically relevant outcome measures
-
E.D. Grober, S.J. Hamstra, and K.R. Wanzel et al. The educational impact of bench model fidelity on the acquisition of technical skill: the use of clinically relevant outcome measures Ann Surg 240 2004 374 381
-
(2004)
Ann Surg
, vol.240
, pp. 374-381
-
-
Grober, E.D.1
Hamstra, S.J.2
Wanzel, K.R.3
-
35
-
-
79952915441
-
The practice of knots untying technique using a 10-0 nylon suture and gauze to cope with technical difficulties of microvascular anastomosis
-
M. Indo, K. Tsutsumi, and M. Shin The practice of knots untying technique using a 10-0 nylon suture and gauze to cope with technical difficulties of microvascular anastomosis World Neurosurg 75 2011 87 89
-
(2011)
World Neurosurg
, vol.75
, pp. 87-89
-
-
Indo, M.1
Tsutsumi, K.2
Shin, M.3
-
36
-
-
41449097749
-
A new training method to improve deep microsurgical skills using a mannequin head
-
M. Takeuchi, N. Hayashi, and H. Hamada et al. A new training method to improve deep microsurgical skills using a mannequin head Microsurgery 28 2008 168 170
-
(2008)
Microsurgery
, vol.28
, pp. 168-170
-
-
Takeuchi, M.1
Hayashi, N.2
Hamada, H.3
-
37
-
-
37849187327
-
Training of A3-A3 side-to-side anastomosis in a deep corridor using a box with 6.5-cm depth: Technical note
-
T. Inoue, K. Tsutsumi, and K. Saito et al. Training of A3-A3 side-to-side anastomosis in a deep corridor using a box with 6.5-cm depth: technical note Surg Neurol 66 2006 638 641
-
(2006)
Surg Neurol
, vol.66
, pp. 638-641
-
-
Inoue, T.1
Tsutsumi, K.2
Saito, K.3
-
38
-
-
34547896287
-
Validation of microsurgical models in microsurgery training and competence: A review
-
W.Y. Chan, P. Matteucci, and S.J. Southern Validation of microsurgical models in microsurgery training and competence: a review Microsurgery 27 2007 494 499
-
(2007)
Microsurgery
, vol.27
, pp. 494-499
-
-
Chan, W.Y.1
Matteucci, P.2
Southern, S.J.3
-
39
-
-
53149088602
-
Microvascular anastomosis training model based on a Turkey neck with perfused arteries
-
discussion ONS10-1
-
M.E. Colpan, K.V. Slavin, and S. Amin-Hanjani et al. Microvascular anastomosis training model based on a Turkey neck with perfused arteries Neurosurgery 62 2008 ONS407 410 discussion ONS10-1
-
(2008)
Neurosurgery
, vol.62
, pp. 407-410
-
-
Colpan, M.E.1
Slavin, K.V.2
Amin-Hanjani, S.3
-
40
-
-
24344492922
-
Learning to perform microvascular anastomosis
-
J.D. MacDonald Learning to perform microvascular anastomosis Skull Base 15 2005 229 240
-
(2005)
Skull Base
, vol.15
, pp. 229-240
-
-
Macdonald, J.D.1
-
41
-
-
75649114245
-
Microsurgical training on an in vitro chicken wing infusion model
-
J. Olabe, and J. Olabe Microsurgical training on an in vitro chicken wing infusion model Surg Neurol 72 2009 695 699
-
(2009)
Surg Neurol
, vol.72
, pp. 695-699
-
-
Olabe, J.1
Olabe, J.2
-
42
-
-
3342969327
-
Simple and viable in vitro perfusion model for training microvascular anastomoses
-
K.G. Krishnan, P. Dramm, and G. Schackert Simple and viable in vitro perfusion model for training microvascular anastomoses Microsurgery 24 2004 335 338
-
(2004)
Microsurgery
, vol.24
, pp. 335-338
-
-
Krishnan, K.G.1
Dramm, P.2
Schackert, G.3
-
43
-
-
0034940572
-
The usefulness of a fresh chicken leg as an experimental model during the intermediate stages of microsurgical training
-
M. Galeano, and A.G. Zarabini The usefulness of a fresh chicken leg as an experimental model during the intermediate stages of microsurgical training Ann Plast Surg 47 2001 96 97
-
(2001)
Ann Plast Surg
, vol.47
, pp. 96-97
-
-
Galeano, M.1
Zarabini, A.G.2
-
44
-
-
0035150327
-
Microvascular simulator - A device for micro-anastomosis training
-
M.A. Senior, S.J. Southern, and S. Majumder Microvascular simulator - a device for micro-anastomosis training Ann R Coll Surg Engl 83 2001 358 360
-
(2001)
Ann R Coll Surg Engl
, vol.83
, pp. 358-360
-
-
Senior, M.A.1
Southern, S.J.2
Majumder, S.3
-
45
-
-
26844528948
-
Use of cryopreserved rat arteries for microsurgical training
-
N.R. Lausada, E. Escudero, and R. Lamonega et al. Use of cryopreserved rat arteries for microsurgical training Microsurgery 25 2005 500 501
-
(2005)
Microsurgery
, vol.25
, pp. 500-501
-
-
Lausada, N.R.1
Escudero, E.2
Lamonega, R.3
-
46
-
-
33746453318
-
Pulsatile perfused porcine coronary arteries for microvascular training
-
H. Schoffl, D. Hager, and C. Hinterdorfer et al. Pulsatile perfused porcine coronary arteries for microvascular training Ann Plast Surg 57 2006 213 216
-
(2006)
Ann Plast Surg
, vol.57
, pp. 213-216
-
-
Schoffl, H.1
Hager, D.2
Hinterdorfer, C.3
-
47
-
-
33846444333
-
Laboratory-based vascular anastomosis training: A randomized controlled trial evaluating the effects of bench model fidelity and level of training on skill acquisition
-
R.S. Sidhu, J. Park, and R. Brydges et al. Laboratory-based vascular anastomosis training: a randomized controlled trial evaluating the effects of bench model fidelity and level of training on skill acquisition J Vasc Surg 45 2007 343 349
-
(2007)
J Vasc Surg
, vol.45
, pp. 343-349
-
-
Sidhu, R.S.1
Park, J.2
Brydges, R.3
-
48
-
-
84896100749
-
Human cadaver brain infusion skull model for neurosurgical training
-
J. Olabe, J. Olabe, and J.M. Roda et al. Human cadaver brain infusion skull model for neurosurgical training Surg Neurol Int 2 2011 54
-
(2011)
Surg Neurol Int
, vol.2
, pp. 54
-
-
Olabe, J.1
Olabe, J.2
Roda, J.M.3
-
49
-
-
0036897044
-
New laboratory model for neurosurgical training that simulates live surgery
-
E. Aboud, O. Al-Mefty, and M.G. Yaşargil New laboratory model for neurosurgical training that simulates live surgery J Neurosurg 97 2002 1367 1372
-
(2002)
J Neurosurg
, vol.97
, pp. 1367-1372
-
-
Aboud, E.1
Al-Mefty, O.2
Yaşargil, M.G.3
-
50
-
-
75649112659
-
Human cadaver brain infusion model for neurosurgical training
-
J. Olabe, J. Olabe, and V. Sancho Human cadaver brain infusion model for neurosurgical training Surg Neurol 72 2009 700 702
-
(2009)
Surg Neurol
, vol.72
, pp. 700-702
-
-
Olabe, J.1
Olabe, J.2
Sancho, V.3
-
51
-
-
84870294718
-
Simulation of a high-flow EC-IC bypass using a radial artery graft in a novel fresh tissue model
-
discussion 319-20
-
J.J. Russin, W.J. Mack, and J.N. Carey et al. Simulation of a high-flow EC-IC bypass using a radial artery graft in a novel fresh tissue model Neurosurgery 71 2012 315 319 discussion 319-20
-
(2012)
Neurosurgery
, vol.71
, pp. 315-319
-
-
Russin, J.J.1
Mack, W.J.2
Carey, J.N.3
-
52
-
-
77952973483
-
Skull base training and education using an artificial skull model created by selective laser sintering
-
discussion 9-60
-
M. Wanibuchi, M. Ohtaki, and T. Fukushima et al. Skull base training and education using an artificial skull model created by selective laser sintering Acta Neurochir (Wien) 152 2010 1055 1059 discussion 9-60
-
(2010)
Acta Neurochir (Wien)
, vol.152
, pp. 1055-1059
-
-
Wanibuchi, M.1
Ohtaki, M.2
Fukushima, T.3
-
53
-
-
84857787121
-
Three-dimensional anatomical accuracy of cranial models created by rapid prototyping techniques validated using a neuronavigation station
-
V. Waran, P. Devaraj, and T. Hari Chandran et al. Three-dimensional anatomical accuracy of cranial models created by rapid prototyping techniques validated using a neuronavigation station J Clin Neurosci 19 2012 574 577
-
(2012)
J Clin Neurosci
, vol.19
, pp. 574-577
-
-
Waran, V.1
Devaraj, P.2
Hari Chandran, T.3
-
54
-
-
0032984759
-
Measuring and developing suturing technique with a virtual reality surgical simulator
-
R.V. O'Toole, R.R. Playter, and T.M. Krummel et al. Measuring and developing suturing technique with a virtual reality surgical simulator J Am Coll Surg 189 1999 114 127
-
(1999)
J Am Coll Surg
, vol.189
, pp. 114-127
-
-
O'Toole, R.V.1
Playter, R.R.2
Krummel, T.M.3
-
55
-
-
0036754447
-
Algorithmic tools for real-time microsurgery simulation
-
J. Brown, S. Sorkin, and J.C. Latombe et al. Algorithmic tools for real-time microsurgery simulation Med Image Anal 6 2002 289 300
-
(2002)
Med Image Anal
, vol.6
, pp. 289-300
-
-
Brown, J.1
Sorkin, S.2
Latombe, J.C.3
-
56
-
-
0037372786
-
Virtual reality surgery: Neurosurgery and the contemporary landscape
-
discussion 96-7
-
M.A. Spicer, and M.L. Apuzzo Virtual reality surgery: neurosurgery and the contemporary landscape Neurosurgery 52 2003 489 497 discussion 96-7
-
(2003)
Neurosurgery
, vol.52
, pp. 489-497
-
-
Spicer, M.A.1
Apuzzo, M.L.2
-
57
-
-
84866443238
-
Virtual reality training in neurosurgery: Review of current status and future applications
-
A. Alaraj, M.G. Lemole, and J.H. Finkle et al. Virtual reality training in neurosurgery: review of current status and future applications Surg Neurol Int 2 2011 52
-
(2011)
Surg Neurol Int
, vol.2
, pp. 52
-
-
Alaraj, A.1
Lemole, M.G.2
Finkle, J.H.3
-
58
-
-
77957977387
-
Simulation in neurosurgery: A review of computer-based simulation environments and their surgical applications
-
H.R. Malone, O.N. Syed, and M.S. Downes et al. Simulation in neurosurgery: a review of computer-based simulation environments and their surgical applications Neurosurgery 67 2010 1105 1116
-
(2010)
Neurosurgery
, vol.67
, pp. 1105-1116
-
-
Malone, H.R.1
Syed, O.N.2
Downes, M.S.3
-
59
-
-
28844481868
-
Quantitative measures of performance in microvascular anastomoses
-
P.B. McBeth, D.F. Louw, and F. Yang et al. Quantitative measures of performance in microvascular anastomoses Comput Aided Surg 10 2005 173 180
-
(2005)
Comput Aided Surg
, vol.10
, pp. 173-180
-
-
McBeth, P.B.1
Louw, D.F.2
Yang, F.3
-
60
-
-
0041832176
-
Validation of novel and objective measures of microsurgical skill: Hand-motion analysis and stereoscopic visual acuity
-
E.D. Grober, S.J. Hamstra, and K.R. Wanzel et al. Validation of novel and objective measures of microsurgical skill: hand-motion analysis and stereoscopic visual acuity Microsurgery 23 2003 317 322
-
(2003)
Microsurgery
, vol.23
, pp. 317-322
-
-
Grober, E.D.1
Hamstra, S.J.2
Wanzel, K.R.3
-
61
-
-
32644433546
-
Learning microsurgical suturing and knotting techniques: Comparative data
-
I. Furka, E. Brath, and N. Nemeth et al. Learning microsurgical suturing and knotting techniques: comparative data Microsurgery 26 2006 4 7
-
(2006)
Microsurgery
, vol.26
, pp. 4-7
-
-
Furka, I.1
Brath, E.2
Nemeth, N.3
-
62
-
-
0035014372
-
Side-to-side arterial anastomosis model in the rat internal and external carotid arteries
-
N. Matsumura, H. Hamada, and K. Yamatani et al. Side-to-side arterial anastomosis model in the rat internal and external carotid arteries J Reconstr Microsurg 17 2001 263 266
-
(2001)
J Reconstr Microsurg
, vol.17
, pp. 263-266
-
-
Matsumura, N.1
Hamada, H.2
Yamatani, K.3
-
63
-
-
0033646101
-
A human skull cast model for training of intracranial microneurosurgical skills
-
T. Menovsky A human skull cast model for training of intracranial microneurosurgical skills Microsurgery 20 2000 311 313
-
(2000)
Microsurgery
, vol.20
, pp. 311-313
-
-
Menovsky, T.1
-
64
-
-
0032763532
-
An experimental model for side-to-side microvascular anastomosis
-
N. Matsumura, S. Endo, and H. Hamada et al. An experimental model for side-to-side microvascular anastomosis J Reconstr Microsurg 15 1999 581 583
-
(1999)
J Reconstr Microsurg
, vol.15
, pp. 581-583
-
-
Matsumura, N.1
Endo, S.2
Hamada, H.3
-
65
-
-
79960725536
-
Basic training model for supermicrosurgery: A novel practice card model
-
N. Matsumura, Y. Horie, and T. Shibata et al. Basic training model for supermicrosurgery: a novel practice card model J Reconstr Microsurg 27 2011 377 382
-
(2011)
J Reconstr Microsurg
, vol.27
, pp. 377-382
-
-
Matsumura, N.1
Horie, Y.2
Shibata, T.3
-
66
-
-
64649090673
-
A newly designed training tool for microvascular anastomosis techniques: Microvascular practice card
-
N. Matsumura, N. Hayashi, and H. Hamada et al. A newly designed training tool for microvascular anastomosis techniques: microvascular practice card Surg Neurol 71 2009 616 620
-
(2009)
Surg Neurol
, vol.71
, pp. 616-620
-
-
Matsumura, N.1
Hayashi, N.2
Hamada, H.3
-
67
-
-
33746275269
-
Effectiveness of suturing training with 10-0 nylon under fixed and maximum magnification (×20) using desk type microscope
-
T. Inoue, K. Tsutsumi, and S. Adachi et al. Effectiveness of suturing training with 10-0 nylon under fixed and maximum magnification (×20) using desk type microscope Surg Neurol 66 2006 183 187
-
(2006)
Surg Neurol
, vol.66
, pp. 183-187
-
-
Inoue, T.1
Tsutsumi, K.2
Adachi, S.3
-
68
-
-
0026576982
-
The use of placenta in a microvascular exercise
-
S. Ayoubi, P. Ward, and S. Naik et al. The use of placenta in a microvascular exercise Neurosurgery 30 1992 252 254
-
(1992)
Neurosurgery
, vol.30
, pp. 252-254
-
-
Ayoubi, S.1
Ward, P.2
Naik, S.3
|