메뉴 건너뛰기




Volumn 10, Issue 1, 2014, Pages 113-120

Validation of patient specific surgical guides in total hip arthroplasty

Author keywords

Accuracy; Computed tomography; Patient specific surgical guide; Resurfacing; Total hip arthroplasty

Indexed keywords

COMPUTERIZED TOMOGRAPHY; ORTHOPEDICS;

EID: 84895821472     PISSN: 14785951     EISSN: 1478596X     Source Type: Journal    
DOI: 10.1002/rcs.1547     Document Type: Article
Times cited : (14)

References (20)
  • 1
    • 0031665319 scopus 로고    scopus 로고
    • Computer assisted orthopaedic surgery with image based individual templates
    • Radermacher K, Portheine F, Anton M, et al. Computer assisted orthopaedic surgery with image based individual templates. Clin Orthop Relat Res 1998; 354: 28-38.
    • (1998) Clin Orthop Relat Res , vol.354 , pp. 28-38
    • Radermacher, K.1    Portheine, F.2    Anton, M.3
  • 2
    • 55849124682 scopus 로고    scopus 로고
    • Three-dimensional corrective osteotomy of malunited fractures of the upper extremity with use of a computersimulation system
    • Murase T, Oka K, Moritomo H, et al. Three-dimensional corrective osteotomy of malunited fractures of the upper extremity with use of a computersimulation system. J Bone Joint Surg Am 2008; 90: 2375-2389.
    • (2008) J Bone Joint Surg Am , vol.90 , pp. 2375-2389
    • Murase, T.1    Oka, K.2    Moritomo, H.3
  • 3
    • 33646007057 scopus 로고    scopus 로고
    • Computer-assisted total knee Arthroplasty using patient-specific templating
    • Hafez MA, Chelule KL, Seedhom BB, Sherman KP. Computer-assisted total knee Arthroplasty using patient-specific templating. Clin Orthop Relat Res 2006; 444: 184-192.
    • (2006) Clin Orthop Relat Res , vol.444 , pp. 184-192
    • Hafez, M.A.1    Chelule, K.L.2    Seedhom, B.B.3    Sherman, K.P.4
  • 4
    • 77953121045 scopus 로고    scopus 로고
    • Computer-assissted hip resurfacing using individualized drill templates
    • Kunz M, Rudan JF, Xenoyannis GL, Ellis RE. Computer-assissted hip resurfacing using individualized drill templates. J Arthroplasty 2010; 25: 600-606.
    • (2010) J Arthroplasty , vol.25 , pp. 600-606
    • Kunz, M.1    Rudan, J.F.2    Xenoyannis, G.L.3    Ellis, R.E.4
  • 5
    • 77954493866 scopus 로고    scopus 로고
    • A custom-made guide-wirepositioning device for hip surface replacement Arthroplasty: description and first results
    • Raaijmaakers M, Gelaude F, De Smedt K, et al. A custom-made guide-wirepositioning device for hip surface replacement Arthroplasty: description and first results. BMC Musculoskelet Disord 2010; 11: 161-167.
    • (2010) BMC Musculoskelet Disord , vol.11 , pp. 161-167
    • Raaijmaakers, M.1    Gelaude, F.2    De Smedt, K.3
  • 6
    • 80054039184 scopus 로고    scopus 로고
    • A custom-made guide for femoral component positioning in hip resurfacing arthroplasty: development and validation study
    • Andenaert E, De Smedt K, Gelaude F, et al. A custom-made guide for femoral component positioning in hip resurfacing arthroplasty: development and validation study. Comput Aided Surg 2011; 16: 304-309.
    • (2011) Comput Aided Surg , vol.16 , pp. 304-309
    • Andenaert, E.1    De Smedt, K.2    Gelaude, F.3
  • 7
    • 84878969748 scopus 로고    scopus 로고
    • Validation of the femoral component placement during hip resurfacing: a comparison between the conventional jig, patient-specific template, and CT-based navigation
    • Kitada M, Sakai T, Murase T, et al. Validation of the femoral component placement during hip resurfacing: a comparison between the conventional jig, patient-specific template, and CT-based navigation. Int J Med Robot 2013; 9: 223-229.
    • (2013) Int J Med Robot , vol.9 , pp. 223-229
    • Kitada, M.1    Sakai, T.2    Murase, T.3
  • 8
    • 67649417912 scopus 로고    scopus 로고
    • Tailor-made surgical guide based on rapid prototyping technique for cup insertion in total hip arthroplasty
    • Hananouchi T, Saito M, Koyama T, et al. Tailor-made surgical guide based on rapid prototyping technique for cup insertion in total hip arthroplasty. Int J Med Robot 2009; 5: 164-169.
    • (2009) Int J Med Robot , vol.5 , pp. 164-169
    • Hananouchi, T.1    Saito, M.2    Koyama, T.3
  • 9
    • 77950488922 scopus 로고    scopus 로고
    • Tailor-made surgical guide reduces incidence of outliers of cup placement
    • Hananouchi T, Saito M, Koyama T, et al. Tailor-made surgical guide reduces incidence of outliers of cup placement. Clin Orthop Relat Res 2010; 468: 1088-1095.
    • (2010) Clin Orthop Relat Res , vol.468 , pp. 1088-1095
    • Hananouchi, T.1    Saito, M.2    Koyama, T.3
  • 10
    • 82055166059 scopus 로고    scopus 로고
    • Preliminary application of computer-assisted patient-specific acetabular navigational template for total hip arthroplasty in adult single development dysplasia of the hip
    • Zhang YZ, Chen B, Lu S, et al. Preliminary application of computer-assisted patient-specific acetabular navigational template for total hip arthroplasty in adult single development dysplasia of the hip. Int J Med Robot 2011; 7: 469-474.
    • (2011) Int J Med Robot , vol.7 , pp. 469-474
    • Zhang, Y.Z.1    Chen, B.2    Lu, S.3
  • 11
    • 34848905651 scopus 로고    scopus 로고
    • Anatomic hip range of motion after implantation during total hip arthroplasty as measured by a navigation system
    • Miki H, Yamanashi W, Nishii T, et al. Anatomic hip range of motion after implantation during total hip arthroplasty as measured by a navigation system. J Arthroplasty 2007; 22: 946-952.
    • (2007) J Arthroplasty , vol.22 , pp. 946-952
    • Miki, H.1    Yamanashi, W.2    Nishii, T.3
  • 13
    • 0036220260 scopus 로고    scopus 로고
    • Factors predisposing to dislocation after primary total hip prosthesis
    • Jolles BM, Zangger P, Leyvraz PF. Factors predisposing to dislocation after primary total hip prosthesis. J Arthroplasty 2002; 17: 282-288.
    • (2002) J Arthroplasty , vol.17 , pp. 282-288
    • Jolles, B.M.1    Zangger, P.2    Leyvraz, P.F.3
  • 14
    • 20444399895 scopus 로고    scopus 로고
    • Impingement in total hip arthroplasty: a study of retrieved acetabular components
    • Shon WY, Baldini T, Peterson MG, et al. Impingement in total hip arthroplasty: a study of retrieved acetabular components. J Arthroplasty 2005; 20: 427-435.
    • (2005) J Arthroplasty , vol.20 , pp. 427-435
    • Shon, W.Y.1    Baldini, T.2    Peterson, M.G.3
  • 15
    • 0031855096 scopus 로고    scopus 로고
    • Effect of acetabular component orientation on recurrent dislocation, pelvic osteolysis, polyethylene wear, and component migration
    • Kennedy JG, Rogers WB, Soffe KE, et al. Effect of acetabular component orientation on recurrent dislocation, pelvic osteolysis, polyethylene wear, and component migration. J Arthroplasty 1998; 13: 530-534.
    • (1998) J Arthroplasty , vol.13 , pp. 530-534
    • Kennedy, J.G.1    Rogers, W.B.2    Soffe, K.E.3
  • 16
    • 0016707369 scopus 로고
    • Range of motion studies for total hip replacements. A comparative study with a new experimental apparatus
    • Amstutz HC, Lodwig RM, Schurman DJ, Hodgson AG. Range of motion studies for total hip replacements. A comparative study with a new experimental apparatus. Clin Orthop Relat Res 1975; 111: 124-130.
    • (1975) Clin Orthop Relat Res , vol.111 , pp. 124-130
    • Amstutz, H.C.1    Lodwig, R.M.2    Schurman, D.J.3    Hodgson, A.G.4
  • 17
    • 2942615374 scopus 로고    scopus 로고
    • Compliant positioning of total hip components for optimal range of motion
    • Widmer KH, Zurfluh B. Compliant positioning of total hip components for optimal range of motion. J Orthop Res 2004; 22: 815-821.
    • (2004) J Orthop Res , vol.22 , pp. 815-821
    • Widmer, K.H.1    Zurfluh, B.2
  • 18
    • 49849098395 scopus 로고    scopus 로고
    • Learning how to resurface cam-type femoral heads with acceptable accuracy and precision: the role of computed tomography-based navigation
    • Cobb JP, Kannan V, Dandachli W, et al. Learning how to resurface cam-type femoral heads with acceptable accuracy and precision: the role of computed tomography-based navigation. J Bone Joint Surg Am 2008; 90-A(Suppl): 57-64.
    • (2008) J Bone Joint Surg Am , vol.90 A , Issue.SUPPL , pp. 57-64
    • Cobb, J.P.1    Kannan, V.2    Dandachli, W.3
  • 19
    • 78951487450 scopus 로고    scopus 로고
    • Improving cup positioning using a mechanical navigation instrument
    • Steppacher SD, Kowal JH, Murphy SB. Improving cup positioning using a mechanical navigation instrument. Clin Orthop Relat Res 2011; 469: 423-428.
    • (2011) Clin Orthop Relat Res , vol.469 , pp. 423-428
    • Steppacher, S.D.1    Kowal, J.H.2    Murphy, S.B.3
  • 20
    • 79960472564 scopus 로고    scopus 로고
    • Evaluation of the accuracy of computed tomography-based navigation for femoral stem orientation and leg length discrepancy
    • Kitada M, Nakamura N, Iwana D, et al. Evaluation of the accuracy of computed tomography-based navigation for femoral stem orientation and leg length discrepancy. J Arthroplasty 2011; 26: 674-679.
    • (2011) J Arthroplasty , vol.26 , pp. 674-679
    • Kitada, M.1    Nakamura, N.2    Iwana, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.