메뉴 건너뛰기




Volumn 9, Issue 2, 2013, Pages 223-229

Validation of the femoral component placement during hip resurfacing: A comparison between the conventional jig, patient-specific template, and CT-based navigation

Author keywords

CT based navigation; Hip resurfacing; Patient specific template

Indexed keywords

COMPUTERIZED TOMOGRAPHY; MEAN SQUARE ERROR; NAVIGATION;

EID: 84878969748     PISSN: 14785951     EISSN: 1478596X     Source Type: Journal    
DOI: 10.1002/rcs.1490     Document Type: Article
Times cited : (21)

References (15)
  • 1
    • 49849083000 scopus 로고    scopus 로고
    • Results and lessons learned from a United States hip resurfacing investigational device exemption trial
    • Stulberg BN, Trier KK, Naughton M, Zadzilka JD. Results and lessons learned from a United States hip resurfacing investigational device exemption trial. J Bone Joint Surg Am 2008; 90(Suppl 3): 21-26.
    • (2008) J Bone Joint Surg Am , vol.90 , Issue.SUPPL. 3 , pp. 21-26
    • Stulberg, B.N.1    Trier, K.K.2    Naughton, M.3    Zadzilka, J.D.4
  • 2
    • 17744365971 scopus 로고    scopus 로고
    • Femoral neck fractures following Birmingham hip resurfacing: a national review of 50 cases
    • Shimmin AJ, Back D. Femoral neck fractures following Birmingham hip resurfacing: a national review of 50 cases. J Bone Joint Surg Br 2005; 87: 463-464.
    • (2005) J Bone Joint Surg Br , vol.87 , pp. 463-464
    • Shimmin, A.J.1    Back, D.2
  • 3
    • 77956641114 scopus 로고    scopus 로고
    • A comparison of conventional guidewire alignment jigs with imageless computer navigation in hip resurfacing arthroplasty
    • Olsen M, Chiu M, Gamble P, et al. A comparison of conventional guidewire alignment jigs with imageless computer navigation in hip resurfacing arthroplasty. J Bone Joint Surg Am 2010; 92: 1834-1841.
    • (2010) J Bone Joint Surg Am , vol.92 , pp. 1834-1841
    • Olsen, M.1    Chiu, M.2    Gamble, P.3
  • 4
    • 34249794249 scopus 로고    scopus 로고
    • The accuracy of image-free computer navigation in the placement of the femoral component of the Birmingham hip resurfacing: a cadaver study
    • Davis ET, Gallie P, Macgroarty K, et al. The accuracy of image-free computer navigation in the placement of the femoral component of the Birmingham hip resurfacing: a cadaver study. J Bone Joint Surg Br 2007; 89: 557-560.
    • (2007) J Bone Joint Surg Br , vol.89 , pp. 557-560
    • Davis, E.T.1    Gallie, P.2    Macgroarty, K.3
  • 6
    • 49849098395 scopus 로고    scopus 로고
    • Learning how to resurface cam-type femoral heads with acceptable accuracy and precision: the role of computed tomography-based navigation
    • Cobb JP, Kannan V, Dandachli W, et al. Learning how to resurface cam-type femoral heads with acceptable accuracy and precision: the role of computed tomography-based navigation. J Bone Joint Surg Am 2008; 90(Suppl 3): 57-64.
    • (2008) J Bone Joint Surg Am , vol.90 , Issue.SUPPL. 3 , pp. 57-64
    • Cobb, J.P.1    Kannan, V.2    Dandachli, W.3
  • 7
    • 79960472564 scopus 로고    scopus 로고
    • Evaluation of the accuracy of computed tomography-based navigation for femoral stem orientation and leg length discrepancy
    • Kitada M, Nakamura N, Iwana D, et al. Evaluation of the accuracy of computed tomography-based navigation for femoral stem orientation and leg length discrepancy. J Arthroplasty 2011; 26: 674-679.
    • (2011) J Arthroplasty , vol.26 , pp. 674-679
    • Kitada, M.1    Nakamura, N.2    Iwana, D.3
  • 8
    • 84867580065 scopus 로고    scopus 로고
    • Does CT-based navigation improve the long-term survival in ceramic-on-ceramic THA?
    • Sugano N, Takao M, Sakai T, et al. Does CT-based navigation improve the long-term survival in ceramic-on-ceramic THA? Clin Orthop Relat Res 2012; 470: 3054-3059.
    • (2012) Clin Orthop Relat Res , vol.470 , pp. 3054-3059
    • Sugano, N.1    Takao, M.2    Sakai, T.3
  • 9
    • 0031665319 scopus 로고    scopus 로고
    • Computer assisted orthopaedic surgery with image based individual templates
    • Radermacher K, Portheine F, Anton M, et al. Computer assisted orthopaedic surgery with image based individual templates. Clin Orthop Relat Res 1998; 354: 28-38.
    • (1998) Clin Orthop Relat Res , vol.354 , pp. 28-38
    • Radermacher, K.1    Portheine, F.2    Anton, M.3
  • 10
    • 77953121045 scopus 로고    scopus 로고
    • Computer-assisted hip resurfacing using individualized drill templates
    • Kunz M, Rudan JF, Xenoyannis GL, Ellis RE. Computer-assisted hip resurfacing using individualized drill templates. J Arthroplasty 2010; 25: 600-606.
    • (2010) J Arthroplasty , vol.25 , pp. 600-606
    • Kunz, M.1    Rudan, J.F.2    Xenoyannis, G.L.3    Ellis, R.E.4
  • 11
    • 77954493866 scopus 로고    scopus 로고
    • A custom-made guide-wire positioning device for hip surface replacement arthroplasty: description and first results
    • Raaijmaakers M, Gelaude F, De Smedt K, et al. A custom-made guide-wire positioning device for hip surface replacement arthroplasty: description and first results. BMC Musculoskelet Disord 2010; 11: 161.
    • (2010) BMC Musculoskelet Disord , vol.11 , pp. 161
    • Raaijmaakers, M.1    Gelaude, F.2    De Smedt, K.3
  • 12
    • 34848905651 scopus 로고    scopus 로고
    • Anatomic hip range of motion after implantation during total hip arthroplasty as measured by a navigation system
    • Miki H, Yamanashi W, Nishii T, et al. Anatomic hip range of motion after implantation during total hip arthroplasty as measured by a navigation system. J Arthroplasty 2007; 22: 946-952.
    • (2007) J Arthroplasty , vol.22 , pp. 946-952
    • Miki, H.1    Yamanashi, W.2    Nishii, T.3
  • 14
    • 80054039184 scopus 로고    scopus 로고
    • A custom-made guide for femoral component positioning in hip resurfacing arthroplasty: development and validation study
    • Audenaert E, De Smedt K, Gelaude F, et al. A custom-made guide for femoral component positioning in hip resurfacing arthroplasty: development and validation study. Comput Aided Surg 2011; 16: 304-309.
    • (2011) Comput Aided Surg , vol.16 , pp. 304-309
    • Audenaert, E.1    De Smedt, K.2    Gelaude, F.3
  • 15
    • 69249214255 scopus 로고    scopus 로고
    • Accuracy of computer-assisted navigation for femoral head resurfacing decreases in hips with abnormal anatomy
    • Pitto RP, Malak S, Anderson IA. Accuracy of computer-assisted navigation for femoral head resurfacing decreases in hips with abnormal anatomy. Clin Orthop Relat Res 2009; 467: 2310-2317.
    • (2009) Clin Orthop Relat Res , vol.467 , pp. 2310-2317
    • Pitto, R.P.1    Malak, S.2    Anderson, I.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.