메뉴 건너뛰기




Volumn 16, Issue 6, 2011, Pages 304-309

A custom-made guide for femoral component positioning in hip resurfacing arthroplasty: Development and validation study

Author keywords

Accuracy; Computer assisted surgery; Orthopaedic surgery; Surgical planning

Indexed keywords

ARTICLE; AUDIOVISUAL EQUIPMENT; BIOMECHANICS; CADAVER; COMPUTER ASSISTED SURGERY; CONCEPT FORMATION; FEMUR; HIP; HIP ARTHROPLASTY; HISTOLOGY; HUMAN; INSTRUMENTATION; METHODOLOGY; PATHOLOGY; POSTOPERATIVE PERIOD; REPRODUCIBILITY; THREE DIMENSIONAL IMAGING; VALIDATION STUDY;

EID: 80054039184     PISSN: 10929088     EISSN: 10970150     Source Type: Journal    
DOI: 10.3109/10929088.2011.613951     Document Type: Article
Times cited : (25)

References (11)
  • 1
    • 69249222921 scopus 로고    scopus 로고
    • Learning from the learning curve in total hip resurfacing: A radiographic analysis
    • Witjes S, Smolders J, Beaulé P, Pasker P, Van Susante J. Learning from the learning curve in total hip resurfacing: A radiographic analysis. Arch Orthop Trauma Surg 2009;129(10):1293-1299.
    • (2009) Arch Orthop Trauma Surg , vol.129 , Issue.10 , pp. 1293-1299
    • Witjes, S.1    Smolders, J.2    Beaulé, P.3    Pasker, P.4    Van Susante, J.5
  • 2
    • 49849101720 scopus 로고    scopus 로고
    • Imageless navigation in hip resurfacing: Avoiding component malposition during the surgeon learning curve
    • Romanowski J, Swank M. Imageless navigation in hip resurfacing: Avoiding component malposition during the surgeon learning curve. J Bone Joint Surg Am 2008;90(1):65-70.
    • (2008) J Bone Joint Surg Am , vol.90 , Issue.1 , pp. 65-70
    • Romanowski, J.1    Swank, M.2
  • 3
    • 49849089116 scopus 로고    scopus 로고
    • Does computer-assisted surgery improve accuracy and decrease the learning curve in hip resurfacing? A radiographic analysis
    • Seyler T, Lai L, Sprinkle D, Ward W, Jinnah R. Does computer-assisted surgery improve accuracy and decrease the learning curve in hip resurfacing? A radiographic analysis. J Bone Joint Surg Am 2008;90(1):71-80.
    • (2008) J Bone Joint Surg Am , vol.90 , Issue.1 , pp. 71-80
    • Seyler, T.1    Lai, L.2    Sprinkle, D.3    Ward, W.4    Jinnah, R.5
  • 4
    • 55549101580 scopus 로고    scopus 로고
    • Femoral neck fracture following hip resurfacing: The effect of alignment of the femoral component
    • Davis ET, Olsen M, Zdero R, Waddell JP, Schemitsch EH. Femoral neck fracture following hip resurfacing: The effect of alignment of the femoral component. J Bone Joint Surg Br 2008;90(11):1522-1527.
    • (2008) J Bone Joint Surg Br , vol.90 , Issue.11 , pp. 1522-1527
    • Davis, E.T.1    Olsen, M.2    Zdero, R.3    Waddell, J.P.4    Schemitsch, E.H.5
  • 5
    • 49849095334 scopus 로고    scopus 로고
    • Tribology and wear of metal-on-metal hip prostheses: Influence of cup angle and head position
    • Williams S, Leslie I, Isaac G, Jin Z, Ingham E, Fisher J. Tribology and wear of metal-on-metal hip prostheses: Influence of cup angle and head position. J Bone Joint Surg Am 2008;90(3):111-117.
    • (2008) J Bone Joint Surg Am , vol.90 , Issue.3 , pp. 111-117
    • Williams, S.1    Leslie, I.2    Isaac, G.3    Jin, Z.4    Ingham, E.5    Fisher, J.6
  • 7
  • 9
    • 34249794249 scopus 로고    scopus 로고
    • The accuracy of image-free computer navigation in the placement of the femoral component of the Birmingham Hip Resurfacing
    • DOI 10.1302/0301-620X.89B4.17893
    • Davis ET, Gallie P, Macgroarty K, Waddell JP, Schemitsch E. The accuracy of image-free computer navigation in the placement of the femoral component of the Birmingham Hip Resurfacing: A cadaver study. J Bone Joint Surg Br 2007;89(4):557-560. (Pubitemid 46851142)
    • (2007) Journal of Bone and Joint Surgery - Series B , vol.89 , Issue.4 , pp. 557-560
    • Davis, E.T.1    Gallie, P.2    Macgroarty, K.3    Waddell, J.P.4    Schemitsch, E.5
  • 10
    • 47249098939 scopus 로고    scopus 로고
    • Accuracy assessment of CT-based outer surface femur meshes
    • DOI 10.1080/10929080802195783, PII 794916573
    • Gelaude F, Vander Sloten J, Lauwers B. Accuracy assessment of CT-based outer surface femur meshes. Comput Aided Surg 2008;13(4):188-199. (Pubitemid 351990203)
    • (2008) Computer Aided Surgery , vol.13 , Issue.4 , pp. 188-199
    • Gelaude, F.1    Vander Sloten, J.2    Lauwers, B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.