-
1
-
-
70349197791
-
Brachytherapy for prostate cancer: A systematic review
-
Koukourakis G., Kelekis N., Armonis V., et al. Brachytherapy for prostate cancer: A systematic review. Adv Urol 2009, 327945.
-
(2009)
Adv Urol
, pp. 327945
-
-
Koukourakis, G.1
Kelekis, N.2
Armonis, V.3
-
2
-
-
22444433291
-
Anatomy-based inverse planning dose optimization in HDR prostate implant: Atoxicity study
-
Mahmoudieh A., Tremblay C., Beaulieu L., et al. Anatomy-based inverse planning dose optimization in HDR prostate implant: Atoxicity study. Radiother Oncol 2005, 75:318-324.
-
(2005)
Radiother Oncol
, vol.75
, pp. 318-324
-
-
Mahmoudieh, A.1
Tremblay, C.2
Beaulieu, L.3
-
3
-
-
0036140325
-
Direct evidence that prostate tumors show high sensitivity to fractionation (low α/β ratio), similar to late-responding normal tissue
-
Brenner D.J., Martinez A.A., Edmundson G.K., et al. Direct evidence that prostate tumors show high sensitivity to fractionation (low α/β ratio), similar to late-responding normal tissue. Int J Radiat Oncol Biol Phys 2002, 52:6-13.
-
(2002)
Int J Radiat Oncol Biol Phys
, vol.52
, pp. 6-13
-
-
Brenner, D.J.1
Martinez, A.A.2
Edmundson, G.K.3
-
5
-
-
70350712610
-
AAPM recommendations on dose prescription and reporting methods for permanent interstitial brachytherapy for prostate cancer: Report of Task Group 137
-
Nath R., Bice W.S., Butler W.M., et al. AAPM recommendations on dose prescription and reporting methods for permanent interstitial brachytherapy for prostate cancer: Report of Task Group 137. Med Phys 2009, 36:5310-5322.
-
(2009)
Med Phys
, vol.36
, pp. 5310-5322
-
-
Nath, R.1
Bice, W.S.2
Butler, W.M.3
-
6
-
-
84855984259
-
American Brachytherapy Society consensus guidelines for high-dose-rate prostate brachytherapy
-
Yamada Y., Rogers L., Demanes D.J., et al. American Brachytherapy Society consensus guidelines for high-dose-rate prostate brachytherapy. Brachytherapy 2012, 11:20-32.
-
(2012)
Brachytherapy
, vol.11
, pp. 20-32
-
-
Yamada, Y.1
Rogers, L.2
Demanes, D.J.3
-
7
-
-
14744282491
-
GEC/ESTRO-EAU recommendations on temporary brachytherapy using stepping sources for localised prostate cancer
-
Kovács G., Pötter R., Loch T., et al. GEC/ESTRO-EAU recommendations on temporary brachytherapy using stepping sources for localised prostate cancer. Radiother Oncol 2005, 74:137-148.
-
(2005)
Radiother Oncol
, vol.74
, pp. 137-148
-
-
Kovács, G.1
Pötter, R.2
Loch, T.3
-
8
-
-
0032930340
-
Definition of the prostate in CT and MRI: A multi-observer study
-
Rasch C., Barillot I., Remeijer P., et al. Definition of the prostate in CT and MRI: A multi-observer study. Int J Radiat Oncol Biol Phys 1999, 43:57-66.
-
(1999)
Int J Radiat Oncol Biol Phys
, vol.43
, pp. 57-66
-
-
Rasch, C.1
Barillot, I.2
Remeijer, P.3
-
9
-
-
79957552144
-
Can images obtained with high field strength magnetic resonance imaging reduce contouring variability of the prostate?
-
Usmani N., Sloboda R., Kamal W., et al. Can images obtained with high field strength magnetic resonance imaging reduce contouring variability of the prostate?. Int J Radiat Oncol Biol Phys 2011, 80:728-734.
-
(2011)
Int J Radiat Oncol Biol Phys
, vol.80
, pp. 728-734
-
-
Usmani, N.1
Sloboda, R.2
Kamal, W.3
-
10
-
-
33847333327
-
Prostate volume contouring: A3D analysis of segmentation using 3DTRUS, CT, and MR
-
Smith W.L., Lewis C., Bauman G., et al. Prostate volume contouring: A3D analysis of segmentation using 3DTRUS, CT, and MR. Int J Radiat Oncol Biol Phys 2007, 67:1238-1247.
-
(2007)
Int J Radiat Oncol Biol Phys
, vol.67
, pp. 1238-1247
-
-
Smith, W.L.1
Lewis, C.2
Bauman, G.3
-
11
-
-
79958792539
-
Use of cone-beam imaging to correct for catheter displacement in high dose-rate prostate brachytherapy
-
Holly R., Morton G.C., Sankreacha R., et al. Use of cone-beam imaging to correct for catheter displacement in high dose-rate prostate brachytherapy. Brachytherapy 2011, 10:299-305.
-
(2011)
Brachytherapy
, vol.10
, pp. 299-305
-
-
Holly, R.1
Morton, G.C.2
Sankreacha, R.3
-
12
-
-
79951854571
-
HDR monotherapy for prostate cancer: A simulation study to determine the effect of catheter displacement on target coverage and normal tissue irradiation
-
Kolkman-Deurloo I.K., Roos M.A., Aluwini S. HDR monotherapy for prostate cancer: A simulation study to determine the effect of catheter displacement on target coverage and normal tissue irradiation. Radiother Oncol 2011, 98:192-197.
-
(2011)
Radiother Oncol
, vol.98
, pp. 192-197
-
-
Kolkman-Deurloo, I.K.1
Roos, M.A.2
Aluwini, S.3
-
13
-
-
84862533355
-
Comparison of prostate volume, shape, and contouring variability determined from preimplant magnetic resonance and transrectal ultrasound images
-
Liu D., Usmani N., Ghosh S., et al. Comparison of prostate volume, shape, and contouring variability determined from preimplant magnetic resonance and transrectal ultrasound images. Brachytherapy 2012, 11:284-291.
-
(2012)
Brachytherapy
, vol.11
, pp. 284-291
-
-
Liu, D.1
Usmani, N.2
Ghosh, S.3
-
14
-
-
80055089988
-
A novel method for accurate needle-tip identification in trans-rectal ultrasound-based high-dose-rate prostate brachytherapy
-
Zheng D., Todor D.A. A novel method for accurate needle-tip identification in trans-rectal ultrasound-based high-dose-rate prostate brachytherapy. Brachytherapy 2011, 10:466-473.
-
(2011)
Brachytherapy
, vol.10
, pp. 466-473
-
-
Zheng, D.1
Todor, D.A.2
-
15
-
-
84871810699
-
A phantom study to assessaccuracy of needle identification in real-time planning of ultrasound-guided high-dose-rate prostate implants
-
Schmid M., Crook J.M., Batchelar D., et al. A phantom study to assessaccuracy of needle identification in real-time planning of ultrasound-guided high-dose-rate prostate implants. Brachytherapy 2013, 12:56-64.
-
(2013)
Brachytherapy
, vol.12
, pp. 56-64
-
-
Schmid, M.1
Crook, J.M.2
Batchelar, D.3
-
16
-
-
80051669771
-
Open MR-guided high-dose-rate (HDR) prostate brachytherapy: Feasibility and initial experiences
-
Lakosi F., Antal G., Vandulek C., et al. Open MR-guided high-dose-rate (HDR) prostate brachytherapy: Feasibility and initial experiences. Pathol Oncol Res 2011, 17:315-324.
-
(2011)
Pathol Oncol Res
, vol.17
, pp. 315-324
-
-
Lakosi, F.1
Antal, G.2
Vandulek, C.3
-
17
-
-
35648940686
-
Intraoperative adaptive brachytherapy of iodine-125 prostate implants guided by C-arm cone-beam computed tomography-based dosimetry
-
Westendorp H., Hoekstra C.J., van't Riet A., et al. Intraoperative adaptive brachytherapy of iodine-125 prostate implants guided by C-arm cone-beam computed tomography-based dosimetry. Brachytherapy 2007, 6:231-237.
-
(2007)
Brachytherapy
, vol.6
, pp. 231-237
-
-
Westendorp, H.1
Hoekstra, C.J.2
van't Riet, A.3
-
18
-
-
0032518595
-
A conformal index (COIN) to evaluate implant quality and dose specification in brachytherapy
-
Baltas D., Kolotas C., Geramani K., et al. A conformal index (COIN) to evaluate implant quality and dose specification in brachytherapy. Int J Radiat Oncol Biol Phys 1998, 40:515-524.
-
(1998)
Int J Radiat Oncol Biol Phys
, vol.40
, pp. 515-524
-
-
Baltas, D.1
Kolotas, C.2
Geramani, K.3
-
19
-
-
3042658240
-
Inverse planning for HDR prostate brachytherapy used to boost dominant intraprostatic lesions defined by magnetic resonance spectroscopy imaging
-
Pouliot J., Kim Y., Lessard E., et al. Inverse planning for HDR prostate brachytherapy used to boost dominant intraprostatic lesions defined by magnetic resonance spectroscopy imaging. Int J Radiat Oncol Biol Phys 2004, 59:1196-1207.
-
(2004)
Int J Radiat Oncol Biol Phys
, vol.59
, pp. 1196-1207
-
-
Pouliot, J.1
Kim, Y.2
Lessard, E.3
-
20
-
-
84860440903
-
Methods of verifying the output of the treatment planning system used for high dose rate (HDR) prostate brachytherapy
-
Huckle A., Al-Qaisieh B., Bownes P. Methods of verifying the output of the treatment planning system used for high dose rate (HDR) prostate brachytherapy. Radiother Oncol 2012, 103:261-265.
-
(2012)
Radiother Oncol
, vol.103
, pp. 261-265
-
-
Huckle, A.1
Al-Qaisieh, B.2
Bownes, P.3
-
21
-
-
77952573175
-
Single-fraction high-dose-rate brachytherapy and hypofractionated external beam radiotherapy for men with intermediate-risk prostate cancer: Analysis of short- and medium-term toxicity and quality of life
-
Morton G.C., Loblaw D.A., Sankreacha R., et al. Single-fraction high-dose-rate brachytherapy and hypofractionated external beam radiotherapy for men with intermediate-risk prostate cancer: Analysis of short- and medium-term toxicity and quality of life. Int J Radiat Oncol Biol Phys 2010, 77:811-817.
-
(2010)
Int J Radiat Oncol Biol Phys
, vol.77
, pp. 811-817
-
-
Morton, G.C.1
Loblaw, D.A.2
Sankreacha, R.3
-
22
-
-
79954424099
-
Dosimetric impact of interfraction catheter movement in high-dose rate prostate brachytherapy
-
Foster W., Cunha A.M., Hsu I.C., et al. Dosimetric impact of interfraction catheter movement in high-dose rate prostate brachytherapy. Int J Radiat Oncol Biol Phys 2011, 80:85-90.
-
(2011)
Int J Radiat Oncol Biol Phys
, vol.80
, pp. 85-90
-
-
Foster, W.1
Cunha, A.M.2
Hsu, I.C.3
-
23
-
-
38049120408
-
Measurement of craniocaudal catheter displacement between fractions in computed tomography-based high dose rate brachytherapy of prostate cancer
-
Kim Y., Hsu I.C., Pouliot J. Measurement of craniocaudal catheter displacement between fractions in computed tomography-based high dose rate brachytherapy of prostate cancer. J Appl Clin Med Phys 2007, 8:2415-2427.
-
(2007)
J Appl Clin Med Phys
, vol.8
, pp. 2415-2427
-
-
Kim, Y.1
Hsu, I.C.2
Pouliot, J.3
-
24
-
-
70350500682
-
Justification for inter-fraction correction of catheter movement in fractionated high dose-rate brachytherapy treatment of prostate cancer
-
Simnor T., Li S., Lowe G., et al. Justification for inter-fraction correction of catheter movement in fractionated high dose-rate brachytherapy treatment of prostate cancer. Radiother Oncol 2009, 93:253-258.
-
(2009)
Radiother Oncol
, vol.93
, pp. 253-258
-
-
Simnor, T.1
Li, S.2
Lowe, G.3
-
25
-
-
81855207481
-
Prostate HDR brachytherapy catheter displacement between planning and treatment delivery
-
Whitaker M., Hruby G., Lovett A., et al. Prostate HDR brachytherapy catheter displacement between planning and treatment delivery. Radiother Oncol 2011, 101:490-494.
-
(2011)
Radiother Oncol
, vol.101
, pp. 490-494
-
-
Whitaker, M.1
Hruby, G.2
Lovett, A.3
-
26
-
-
33747171181
-
Minimal displacement of novel self-anchoring catheters suitable for temporary prostate implants
-
Pieters B.R., van der Grient J.N., Blank L.E., et al. Minimal displacement of novel self-anchoring catheters suitable for temporary prostate implants. Radiother Oncol 2006, 80:69-72.
-
(2006)
Radiother Oncol
, vol.80
, pp. 69-72
-
-
Pieters, B.R.1
van der Grient, J.N.2
Blank, L.E.3
-
27
-
-
38149120882
-
HDR prostate monotherapy-Dosimetric effects of implant deformation due to posture change between TRUS- and CT-imaging
-
Seppenwoolde Y., Kolkman-Deurloo I.K., Sipkema D., et al. HDR prostate monotherapy-Dosimetric effects of implant deformation due to posture change between TRUS- and CT-imaging. Radiother Oncol 2008, 86:114-119.
-
(2008)
Radiother Oncol
, vol.86
, pp. 114-119
-
-
Seppenwoolde, Y.1
Kolkman-Deurloo, I.K.2
Sipkema, D.3
|