메뉴 건너뛰기




Volumn 53, Issue 3, 2014, Pages 324-329

Clinical impact of using the deterministic patient dose calculation algorithm Acuros XB for lung stereotactic body radiation therapy

Author keywords

[No Author keywords available]

Indexed keywords

ALGORITHM; ARTICLE; BODY MASS; CONTROLLED STUDY; DOSIMETRY; FEMALE; HUMAN; LUNG FUNCTION; LUNG NON SMALL CELL CANCER; LUNG PARENCHYMA; MAJOR CLINICAL STUDY; MALE; PRIORITY JOURNAL; RADIATION DOSE; RADIATION DOSE DISTRIBUTION; RADIATION DOSE FRACTIONATION; STEREOTACTIC BODY RADIATION THERAPY; TUMOR VOLUME; ANISOTROPY; CANCER LOCALIZATION; CANCER PATIENT; CANCER SIZE; DOSIMETER; LUNG CANCER; TREATMENT PLANNING;

EID: 84894155321     PISSN: 0284186X     EISSN: 1651226X     Source Type: Journal    
DOI: 10.3109/0284186X.2013.822552     Document Type: Article
Times cited : (34)

References (24)
  • 1
    • 34547508285 scopus 로고    scopus 로고
    • The North American experience with stereotactic body radiation therapy in non-small cell lung cancer
    • Timmerman RD, Park C, Kavanagh BD. The North American experience with stereotactic body radiation therapy in non-small cell lung cancer. J Thorac Oncol 2007; 2(7 Suppl 3):S101-12.
    • (2007) J Thorac Oncol , vol.2 , Issue.7 SUPPL. 3
    • Timmerman, R.D.1    Park, C.2    Kavanagh, B.D.3
  • 2
    • 34547510573 scopus 로고    scopus 로고
    • Hypofractionated stereotactic radiotherapy (HypoFXSRT) for stage i non-small cell lung cancer: Updated results of 257 patients in a Japanese multi-institutional study
    • Onishi H, Shirato H, Nagata Y, Hiraoka M, Fujino M, Gomi K, et al. Hypofractionated stereotactic radiotherapy (HypoFXSRT) for stage I non-small cell lung cancer: Updated results of 257 patients in a Japanese multi-institutional study. J Thorac Oncol 2007;2(7 Suppl 3):S94-100.
    • (2007) J Thorac Oncol , vol.2 , Issue.7 SUPPL. 3
    • Onishi, H.1    Shirato, H.2    Nagata, Y.3    Hiraoka, M.4    Fujino, M.5    Gomi, K.6
  • 3
    • 79954598436 scopus 로고    scopus 로고
    • Dose escalation for non-small cell lung cancer: Analysis and modelling of published literature
    • Partridge M, Ramos M, Sardaro A, Brada M. Dose escalation for non-small cell lung cancer: Analysis and modelling of published literature. Radiother Oncol 2011;99:6-11.
    • (2011) Radiother Oncol , vol.99 , pp. 6-11
    • Partridge, M.1    Ramos, M.2    Sardaro, A.3    Brada, M.4
  • 4
    • 27144516385 scopus 로고    scopus 로고
    • Dose-response in stereotactic irradiation of lung tumors
    • Wulf J, Baier K, Mueller G, Flentje MP. Dose-response in stereotactic irradiation of lung tumors. Radiother Oncol 2005;77:83-7.
    • (2005) Radiother Oncol , vol.77 , pp. 83-87
    • Wulf, J.1    Baier, K.2    Mueller, G.3    Flentje, M.P.4
  • 5
    • 74549169230 scopus 로고    scopus 로고
    • Validation of a new grid-based Boltzmann equation solver for dose calculation in radiotherapy with photon beams
    • Vassiliev ON, Wareing TA, McGhee J, Failla G, Salehpour MR, Mourtada F. Validation of a new grid-based Boltzmann equation solver for dose calculation in radiotherapy with photon beams. Phys Med Biol 2010;55:581-98.
    • (2010) Phys Med Biol , vol.55 , pp. 581-598
    • Vassiliev, O.N.1    Wareing, T.A.2    McGhee, J.3    Failla, G.4    Salehpour, M.R.5    Mourtada, F.6
  • 6
    • 0034036210 scopus 로고    scopus 로고
    • Converting absorbed dose to medium to absorbed dose to water for Monte Carlo based photon beam dose calculations
    • Siebers JV, Keall PJ, Nahum AE, Mohan R. Converting absorbed dose to medium to absorbed dose to water for Monte Carlo based photon beam dose calculations. Phys Med Biol 2000;45:983-95.
    • (2000) Phys Med Biol , vol.45 , pp. 983-995
    • Siebers, J.V.1    Keall, P.J.2    Nahum, A.E.3    Mohan, R.4
  • 7
    • 84859765838 scopus 로고    scopus 로고
    • Clinical validation of the Acuros XB photon dose calculation algorithm, a grid-based Boltzmann equation solver
    • Hoffmann L, Jorgensen MB, Muren LP, Petersen JB. Clinical validation of the Acuros XB photon dose calculation algorithm, a grid-based Boltzmann equation solver. Acta Oncol 2012;51:376-85.
    • (2012) Acta Oncol , vol.51 , pp. 376-385
    • Hoffmann, L.1    Jorgensen, M.B.2    Muren, L.P.3    Petersen, J.B.4
  • 8
    • 79953648704 scopus 로고    scopus 로고
    • Dosimetric validation of Acuros XB with Monte Carlo methods for photon dose calculations
    • Bush K, Gagne IM, Zavgorodni S, Ansbacher W, Beckham W. Dosimetric validation of Acuros XB with Monte Carlo methods for photon dose calculations. Med Phys 2011;38: 2208-21.
    • (2011) Med Phys , vol.38 , pp. 2208-2221
    • Bush, K.1    Gagne, I.M.2    Zavgorodni, S.3    Ansbacher, W.4    Beckham, W.5
  • 9
    • 79960554736 scopus 로고    scopus 로고
    • Dosimetric evaluation of Acuros XB Advanced Dose Calculation algorithm in heterogeneous media
    • Fogliata A, Nicolini G, Clivio A, Vanetti E, Cozzi L. Dosimetric evaluation of Acuros XB Advanced Dose Calculation algorithm in heterogeneous media. Radiat Oncol 2011;6:82.
    • (2011) Radiat Oncol , vol.6 , pp. 82
    • Fogliata, A.1    Nicolini, G.2    Clivio, A.3    Vanetti, E.4    Cozzi, L.5
  • 10
    • 79959550301 scopus 로고    scopus 로고
    • Dosimetric comparison of Acuros XB deterministic radiation transport method with Monte Carlo and model-based convolution methods in heterogeneous media
    • Han T, Mikell.K, Salehpour M, Mourtada F. Dosimetric comparison of Acuros XB deterministic radiation transport method with Monte Carlo and model-based convolution methods in heterogeneous media. Med Phys 2011;38: 2651-64.
    • (2011) Med Phys , vol.38 , pp. 2651-2664
    • Han, T.1    Mikell, K.2    Salehpour, M.3    Mourtada, F.4
  • 11
    • 33646014420 scopus 로고    scopus 로고
    • Comparison of a finite-element multigroup discrete-ordinates code with Monte Carlo for radiotherapy calculations
    • Gifford KA, Horton JL, Wareing TA, Failla G, Mourtada F. Comparison of a finite-element multigroup discrete-ordinates code with Monte Carlo for radiotherapy calculations. Phys Med Biol 2006;51:2253-65.
    • (2006) Phys Med Biol , vol.51 , pp. 2253-2265
    • Gifford, K.A.1    Horton, J.L.2    Wareing, T.A.3    Failla, G.4    Mourtada, F.5
  • 12
    • 84863630399 scopus 로고    scopus 로고
    • Critical appraisal of Acuros XB and Anisotropic Analytic Algorithm dose calculation in advanced non-small-cell lung cancer treatments
    • Fogliata A, Nicolini G, Clivio A, Vanetti E, Cozzi L. Critical appraisal of Acuros XB and Anisotropic Analytic Algorithm dose calculation in advanced non-small-cell lung cancer treatments. Int J Radiat Oncol Biol Phys 2012;83:1587-95.
    • (2012) Int J Radiat Oncol Biol Phys , vol.83 , pp. 1587-1595
    • Fogliata, A.1    Nicolini, G.2    Clivio, A.3    Vanetti, E.4    Cozzi, L.5
  • 13
    • 34247337632 scopus 로고    scopus 로고
    • Evaluation of the analytical anisotropic algorithm in an extreme water-lung interface phantom using Monte Carlo dose calculations
    • Gagne IM, Zavgorodni S. Evaluation of the analytical anisotropic algorithm in an extreme water-lung interface phantom using Monte Carlo dose calculations. J Appl Clin Med Phys 2006;8:33-46.
    • (2006) J Appl Clin Med Phys , vol.8 , pp. 33-46
    • Gagne, I.M.1    Zavgorodni, S.2
  • 14
    • 47649106110 scopus 로고    scopus 로고
    • A 3D pencil-beam-based superposition algorithm for photon dose calculation in heterogeneous media
    • Tillikainen L, Helminen H, Torsti T, Siljamaki S, Alakuijala J, Pyyry J, et al. A 3D pencil-beam-based superposition algorithm for photon dose calculation in heterogeneous media. Phys Med Biol 2008;53:3821-39.
    • (2008) Phys Med Biol , vol.53 , pp. 3821-3839
    • Tillikainen, L.1    Helminen, H.2    Torsti, T.3    Siljamaki, S.4    Alakuijala, J.5    Pyyry, J.6
  • 15
    • 84894169274 scopus 로고    scopus 로고
    • Eclipse Algorithms Reference Guide Part number B503486R01B, December 2011
    • Eclipse Algorithms Reference Guide, pg 53. Varian Medical Systems. Part number B503486R01B, December 2011.
    • Varian Medical Systems , pp. 53
  • 16
    • 84875431970 scopus 로고    scopus 로고
    • Dosimetric evaluation of Acuros XB dose calculation algorithm with measurements in predicting doses beyond different air gap thickness for smaller and larger field sizes
    • Rana S, Rogers K. Dosimetric evaluation of Acuros XB dose calculation algorithm with measurements in predicting doses beyond different air gap thickness for smaller and larger field sizes. J Med Phys 2013;38:9-14.
    • (2013) J Med Phys , vol.38 , pp. 9-14
    • Rana, S.1    Rogers, K.2
  • 17
    • 84876113342 scopus 로고    scopus 로고
    • The influence of target and patient characteristics on the volume obtained from cone beam CT in lung stereotactic body radiation therapy
    • Liu HW, Khan R, DAmbrosi R, Krobutschek K, Nugent Z, Lau H. The influence of target and patient characteristics on the volume obtained from cone beam CT in lung stereotactic body radiation therapy. Radiother Oncol 2013;106:312-6.
    • (2013) Radiother Oncol , vol.106 , pp. 312-316
    • Liu, H.W.1    Khan, R.2    Dambrosi, R.3    Krobutschek, K.4    Nugent, Z.5    Lau, H.6
  • 18
    • 84857668086 scopus 로고    scopus 로고
    • Role of computed tomography in quantitative assessment of emphysema
    • Choromanska A, Macura KJ. Role of computed tomography in quantitative assessment of emphysema. Pol J Radiol 2012;77:28-36.
    • (2012) Pol J Radiol , vol.77 , pp. 28-36
    • Choromanska, A.1    Macura, K.J.2
  • 19
    • 65649096221 scopus 로고    scopus 로고
    • The effect of different lung densities on the accuracy of various radiotherapy dose calculation methods: Implications for tumour coverage
    • Aarup LR, Nahum AE, Zacharatou C, Juhler-Nottrup T, Knoos T, Nystrom H, et al. The effect of different lung densities on the accuracy of various radiotherapy dose calculation methods: Implications for tumour coverage. Radiother Oncol 2009;91:405-14.
    • (2009) Radiother Oncol , vol.91 , pp. 405-414
    • Aarup, L.R.1    Nahum, A.E.2    Zacharatou, C.3    Juhler-Nottrup, T.4    Knoos, T.5    Nystrom, H.6
  • 20
    • 33750612133 scopus 로고    scopus 로고
    • Excessive toxicity when treating central tumors in a phase II study of stereotactic body radiation therapy for medically inoperable early-stage lung cancer
    • Timmerman R, McGarry R, Yiannoutsos C, Papiez L, Tudor K, DeLuca J, et al. Excessive toxicity when treating central tumors in a phase II study of stereotactic body radiation therapy for medically inoperable early-stage lung cancer. J Clin Oncol 2006;24:4833-9.
    • (2006) J Clin Oncol , vol.24 , pp. 4833-4839
    • Timmerman, R.1    McGarry, R.2    Yiannoutsos, C.3    Papiez, L.4    Tudor, K.5    Deluca, J.6
  • 21
    • 0342617576 scopus 로고    scopus 로고
    • A conformation number to quantify the degree of conformality in brachytherapy and external beam irradiation: Application to the prostate
    • vant Riet A, Mak AC, Moerland MA, Elders LH, van der Zee W. A conformation number to quantify the degree of conformality in brachytherapy and external beam irradiation: Application to the prostate. Int J Radiat Oncol Biol Phys. 1997;37:731-6.
    • (1997) Int J Radiat Oncol Biol Phys. , vol.37 , pp. 731-736
    • Vant Riet, A.1    Mak, A.C.2    Ma, M.3    Elders, L.H.4    Van Der Zee, W.5
  • 22
    • 84871370197 scopus 로고    scopus 로고
    • Dosimetric impact of using the Acuros XB algorithm for intensity modulated radiation therapy and RapidArc planning in nasopharyngeal carcinomas
    • Kan MW, Leung LH, Yu PK. Dosimetric impact of using the Acuros XB algorithm for intensity modulated radiation therapy and RapidArc planning in nasopharyngeal carcinomas. Int J Radiat Oncol Biol Phys 2013;85:373-80.
    • (2013) Int J Radiat Oncol Biol Phys , vol.85 , pp. 373-380
    • Kan, M.W.1    Leung, L.H.2    Yu, P.K.3
  • 23
    • 84875153038 scopus 로고    scopus 로고
    • Dosimetric comparison between VMAT with different dose calculation algorithms and protons for soft-tissue sarcoma radiotherapy
    • Fogliata A, Scorsetti M, Navarria P, Catalano M, Clivio A, Cozzi L, et al. Dosimetric comparison between VMAT with different dose calculation algorithms and protons for soft-tissue sarcoma radiotherapy. Acta Oncol 2013;52:545-52.
    • (2013) Acta Oncol , vol.52 , pp. 545-552
    • Fogliata, A.1    Scorsetti, M.2    Navarria, P.3    Catalano, M.4    Clivio, A.5    Cozzi, L.6
  • 24
    • 46149107900 scopus 로고    scopus 로고
    • Inhomogeneity correction and the analytic anisotropic algorithm
    • Robinson D. Inhomogeneity correction and the analytic anisotropic algorithm. J Appl Clin Med Phys 2008;9: 2786.
    • (2008) J Appl Clin Med Phys , vol.9 , pp. 2786
    • Robinson, D.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.