Volumn 9, Issue 2, 2008, Pages 112-122

Inhomogeneity correction and the analytic anisotropic algorithm

Author keywords

AAA; Analytic anisotrophic algorithm; Inhomogeneity correction factor

Indexed keywords


EID: 46149107900     PISSN: None     EISSN: 15269914     Source Type: Journal    
DOI: 10.1120/jacmp.v9i2.2786     Document Type: Article
Times cited : (51)

References (14)
  • 1
    • 85024374987 scopus 로고    scopus 로고
    • Radiation Therapy Committee, Task Group 65. Tissue Inhomogeneity Corrections for Megavoltage Photon Beams
    • American Association of Physicists in Medicine (AAPM, No. 85. Madison WI, Medical Physics Publishing;
    • American Association of Physicists in Medicine (AAPM), Radiation Therapy Committee, Task Group 65. Tissue Inhomogeneity Corrections for Megavoltage Photon Beams. AAPM report No. 85. Madison (WI): Medical Physics Publishing; 2004. p. 9.
    • (2004) AAPM report , pp. 9
  • 2
    • 46149122403 scopus 로고
    • Dose distribution problems in megavoltage therapy. I. The problem of air spaces
    • Massey JB. Dose distribution problems in megavoltage therapy. I. The problem of air spaces. Br J Radiol. 1962;35(419):736-738.
    • (1962) Br J Radiol , vol.35 , Issue.419 , pp. 736-738
    • Massey, J.B.1
  • 3
    • 0017195953 scopus 로고
    • Method for calculating dose when lung tissue lies in the treatment field
    • McDonald SC, Keller BE, Rubin P. Method for calculating dose when lung tissue lies in the treatment field. Med Phys. 1976;3(4):210-216.
    • (1976) Med Phys , vol.3 , Issue.4 , pp. 210-216
    • McDonald, S.C.1    Keller, B.E.2    Rubin, P.3
  • 4
    • 0018132661 scopus 로고
    • The equivalent tissue-air ratio method for making absorbed dose calculations in a heterogeneous medium
    • Sontag MR, Cunningham JR. The equivalent tissue-air ratio method for making absorbed dose calculations in a heterogeneous medium. Radiology. 1978;129(3):787-794.
    • (1978) Radiology , vol.129 , Issue.3 , pp. 787-794
    • Sontag, M.R.1    Cunningham, J.R.2
  • 6
    • 0025119995 scopus 로고
    • On methods of inhomogeneity corrections for photon transport
    • Wong JW, Purdy JA. On methods of inhomogeneity corrections for photon transport. Med Phys. 1990;17(5):807-814.
    • (1990) Med Phys , vol.17 , Issue.5 , pp. 807-814
    • Wong, J.W.1    Purdy, J.A.2
  • 7
    • 0024430392 scopus 로고
    • Evaluation of lung dose correction methods for photon irradiations of thorax phantoms
    • el-Khatib EE, Evans M, Pla M, Cunningham JR. Evaluation of lung dose correction methods for photon irradiations of thorax phantoms. Int J Radiat Oncol Biol Phys. 1989;17(4):871-878.
    • (1989) Int J Radiat Oncol Biol Phys , vol.17 , Issue.4 , pp. 871-878
    • el-Khatib, E.E.1    Evans, M.2    Pla, M.3    Cunningham, J.R.4
  • 9
    • 0017667678 scopus 로고
    • Corrections to absorbed dose calculations for tissue inhomogeneities
    • Sontag MR, Cunningham JR. Corrections to absorbed dose calculations for tissue inhomogeneities. Med Phys. 1977;4(5):431-436.
    • (1977) Med Phys , vol.4 , Issue.5 , pp. 431-436
    • Sontag, M.R.1    Cunningham, J.R.2
  • 10
    • 85024379741 scopus 로고
    • Determination of absorbed dose in a patient irradiated by beams of X or gamma rays in radiotherapy procedures
    • International Commission on Radiation Units and Measurements (ICRU, Washington DC, ICRU;
    • International Commission on Radiation Units and Measurements (ICRU). Determination of absorbed dose in a patient irradiated by beams of X or gamma rays in radiotherapy procedures. ICRU Report 24. Washington (DC): ICRU; 1976. p. 22-23.
    • (1976) ICRU Report , vol.24 , pp. 22-23
  • 11
    • 0018885977 scopus 로고
    • Half body radiotherapy: The use of computed tomography to determine the dose to lung
    • Van Dyk J, Battista JJ, Rider WD. Half body radiotherapy: the use of computed tomography to determine the dose to lung. Int J Radiat Oncol Biol Phys. 1980;6(4):463-470.
    • (1980) Int J Radiat Oncol Biol Phys , vol.6 , Issue.4 , pp. 463-470
    • Van Dyk, J.1    Battista, J.J.2    Rider, W.D.3
  • 12
    • 33750574559 scopus 로고    scopus 로고
    • Testing of the analytical anisotropic algorithm for photon dose calculation
    • Van Esch A, Tillikainen L, Pyykkonen J, et al. Testing of the analytical anisotropic algorithm for photon dose calculation. Med Phys. 2006;33(11):4130-4148.
    • (2006) Med Phys , vol.33 , Issue.11 , pp. 4130-4148
    • Van Esch, A.1    Tillikainen, L.2    Pyykkonen, J.3
  • 13
    • 34247207650 scopus 로고    scopus 로고
    • On the dosimetric behaviour of photon dose calculation algorithms in the presence of simple geometric heterogeneities: Comparison with Monte Carlo calculations
    • Fogliata A, Vanetti E, Albers D, et al. On the dosimetric behaviour of photon dose calculation algorithms in the presence of simple geometric heterogeneities: comparison with Monte Carlo calculations. Phys Med Biol. 2007;52(5):1363-1385.
    • (2007) Phys Med Biol , vol.52 , Issue.5 , pp. 1363-1385
    • Fogliata, A.1    Vanetti, E.2    Albers, D.3
  • 14
    • 34247337632 scopus 로고    scopus 로고
    • Evaluation of the analytical anisotropic algorithm in an extreme water-lung interface phantom using Monte Carlo dose calculations
    • Gagné IM, Zavgorodni S. Evaluation of the analytical anisotropic algorithm in an extreme water-lung interface phantom using Monte Carlo dose calculations. J Appl Clin Med Phys. 2007;8(1):33-46.
    • (2007) J Appl Clin Med Phys , vol.8 , Issue.1 , pp. 33-46
    • Gagné, I.M.1    Zavgorodni, S.2