메뉴 건너뛰기




Volumn 49, Issue 3, 2014, Pages 138-146

Magnetic resonance imaging of the liver: Apparent diffusion coefficients from multiexponential analysis of b values greater than 50 s/mm2 do not respond to caloric intake despite increased portal-venous blood flow

Author keywords

apparent diffusion coefficient; diffusion weighted imaging; liver; magnetic resonance imaging

Indexed keywords

ADULT; APPARENT DIFFUSION COEFFICIENT; ARTICLE; CALORIC INTAKE; CARBOHYDRATE INTAKE; CONTRAST ENHANCEMENT; CONTROLLED STUDY; DIET RESTRICTION; DIFFUSION COEFFICIENT; DIFFUSION WEIGHTED IMAGING; FEMALE; HUMAN; HUMAN EXPERIMENT; LIVER EXAMINATION; MALE; NORMAL HUMAN; PORTAL VEIN BLOOD FLOW; PRIORITY JOURNAL; PROTEIN INTAKE; WHOLE BODY MRI; YOUNG ADULT;

EID: 84894078037     PISSN: 00209996     EISSN: 15360210     Source Type: Journal    
DOI: 10.1097/RLI.0000000000000005     Document Type: Article
Times cited : (18)

References (57)
  • 1
    • 49049083456 scopus 로고    scopus 로고
    • Relevance of b-values in evaluating liver fibrosis: A study in healthy and cirrhotic subjects healthy liver using two single-shot spin-echo echo-planar diffusion-weighted sequences
    • Girometti R, Furlan A, Esposito G, et al. Relevance of b-values in evaluating liver fibrosis: A study in healthy and cirrhotic subjects healthy liver using two single-shot spin-echo echo-planar diffusion-weighted sequences. JMagn Reson Imaging. 2008;28:411-419
    • (2008) JMagn Reson Imaging , vol.28 , pp. 411-419
    • Girometti, R.1    Furlan, A.2    Esposito, G.3
  • 2
    • 0028118461 scopus 로고
    • Abdominal diffusion mapping with use of a whole body echo-planar system
    • Muller MF, Prasad P, Siewert B, et al. Abdominal diffusion mapping with use of a whole body echo-planar system. Radiology. 1994;190:475-478
    • (1994) Radiology , vol.190 , pp. 475-478
    • Muller, M.F.1    Prasad, P.2    Siewert, B.3
  • 3
    • 79952296058 scopus 로고    scopus 로고
    • Evaluation of the mean and entropy of apparent diffusion coefficient values in chronic hepatitis C: Correlation with pathologic fibrosis stage and inflammatory activity grade
    • Fujimoto K, Tonan T, Azuma S, et al. Evaluation of the mean and entropy of apparent diffusion coefficient values in chronic hepatitis C: Correlation with pathologic fibrosis stage and inflammatory activity grade. Radiology. 2011;258: 739-748
    • (2011) Radiology , vol.258 , pp. 739-748
    • Fujimoto, K.1    Tonan, T.2    Azuma, S.3
  • 4
    • 34748912281 scopus 로고    scopus 로고
    • Diffusion-weightedmri for quantification of liver fibrosis: Preliminary experience
    • Taouli B, Tolia AJ, Losada M, et al. Diffusion-weightedMRI for quantification of liver fibrosis: Preliminary experience. AJR Am J Roentgenol. 2007;189:799-806
    • (2007) AJR Am J Roentgenol , vol.189 , pp. 799-806
    • Taouli, B.1    Tolia, A.J.2    Losada, M.3
  • 5
    • 40949092665 scopus 로고    scopus 로고
    • Focal liver lesion detection and characterization with diffusion-weighted mr imaging: Comparison with standard breathhold t2-weighted imaging
    • Parikh T, Drew SJ, Lee VS, et al. Focal liver lesion detection and characterization with diffusion-weighted MR imaging: Comparison with standard breathhold T2-weighted imaging. Radiology. 2008;246:812-822
    • (2008) Radiology , vol.246 , pp. 812-822
    • Parikh, T.1    Drew, S.J.2    Lee, V.S.3
  • 6
    • 0037257050 scopus 로고    scopus 로고
    • Evaluation of liver diffusion isotropy and characterization of focal hepatic lesions with two single-shot echo-planar MR imaging sequences: Prospective study in 66 patients
    • Taouli B, Vilgrain VR, Dumont E, et al. Evaluation of liver diffusion isotropy and characterization of focal hepatic lesions with two single-shot echo-planar MR imaging sequences: Prospective study in 66 patients. Radiology. 2003;226:71-78
    • (2003) Radiology , vol.226 , pp. 71-78
    • Taouli, B.1    Vilgrain, V.R.2    Dumont, E.3
  • 7
    • 0032975435 scopus 로고    scopus 로고
    • Diffusion coefficients in abdominal organs and hepatic lesions: Evaluation with intravoxel incoherent motion echo-planar MR imaging
    • Yamada I, AungW, Himeno Y, et al. Diffusion coefficients in abdominal organs and hepatic lesions: Evaluation with intravoxel incoherent motion echo-planar MR imaging. Radiology. 1999;210:617-623
    • (1999) Radiology , vol.210 , pp. 617-623
    • Yamada, I.1    AungW Himeno, Y.2
  • 8
    • 84857423105 scopus 로고    scopus 로고
    • High-b-value diffusion-weighted MR imaging of benign hepatocellular lesions: Quantitative and qualitative analysis
    • Agnello F, Ronot M, Valla DC, et al. High-b-value diffusion-weighted MR imaging of benign hepatocellular lesions: Quantitative and qualitative analysis. Radiology. 2012;262:511-519
    • (2012) Radiology , vol.262 , pp. 511-519
    • Agnello, F.1    Ronot, M.2    Valla, D.C.3
  • 9
    • 67650751866 scopus 로고    scopus 로고
    • Early detection of therapeutic response to hepatic arterial infusion chemotherapy of liver metastases from colorectal cancer using diffusion-weighted MR imaging
    • Marugami N, Tanaka T, Kitano S, et al. Early detection of therapeutic response to hepatic arterial infusion chemotherapy of liver metastases from colorectal cancer using diffusion-weighted MR imaging. Cardiovasc Intervent Radiol. 2009;32:638-646
    • (2009) Cardiovasc Intervent Radiol , vol.32 , pp. 638-646
    • Marugami, N.1    Tanaka, T.2    Kitano, S.3
  • 10
    • 51549112352 scopus 로고    scopus 로고
    • Apparent diffusion coefficient: Potential imaging biomarker for prediction and early detection of response to chemotherapy in hepatic metastases
    • Cui Y, Zhang XP, Sun YS, et al. Apparent diffusion coefficient: Potential imaging biomarker for prediction and early detection of response to chemotherapy in hepatic metastases. Radiology. 2008;248:894-900
    • (2008) Radiology , vol.248 , pp. 894-900
    • Cui, Y.1    Zhang, X.P.2    Sun, Y.S.3
  • 11
    • 84860391243 scopus 로고    scopus 로고
    • Hepatocellular carcinoma: Response to TACE assessed with semiautomated volumetric and functional analysis of diffusionweighted and contrast-enhanced MR imaging data
    • Bonekamp S, Jolepalem P, Lazo M, et al. Hepatocellular carcinoma: Response to TACE assessed with semiautomated volumetric and functional analysis of diffusionweighted and contrast-enhanced MR imaging data. Radiology. 2011;260:752-761
    • (2011) Radiology , vol.260 , pp. 752-761
    • Bonekamp, S.1    Jolepalem, P.2    Lazo, M.3
  • 12
    • 27144541488 scopus 로고    scopus 로고
    • Effect of vascular targeting agent in rat tumor model: Dynamic contrast-enhanced versus diffusion-weighted MR imaging
    • Thoeny HC, et al. Effect of vascular targeting agent in rat tumor model: Dynamic contrast-enhanced versus diffusion-weighted MR imaging. Radiology. 2005;237:492-499
    • (2005) Radiology , vol.237 , pp. 492-499
    • Thoeny, H.C.1
  • 13
    • 61749088918 scopus 로고    scopus 로고
    • Short-And midterm reproducibility of apparent diffusion coefficient measurements at 3.0-T diffusion-weighted imaging of the abdomen
    • Braithwaite AC, Dale BM, Boll DT, et al. Short-And midterm reproducibility of apparent diffusion coefficient measurements at 3.0-T diffusion-weighted imaging of the abdomen. Radiology. 2009;250:459-465
    • (2009) Radiology , vol.250 , pp. 459-465
    • Braithwaite, A.C.1    Dale, B.M.2    Boll, D.T.3
  • 14
    • 77950894817 scopus 로고    scopus 로고
    • MR-diffusion weighted imaging of healthy liver parenchyma: Repeatability and reproducibility of apparent diffusion coefficient measurement
    • Colagrande S, Pasquinelli F, Mazzoni LN, et al. MR-diffusion weighted imaging of healthy liver parenchyma: Repeatability and reproducibility of apparent diffusion coefficient measurement. J Magn Reson Imaging. 2010;31:912-920
    • (2010) J Magn Reson Imaging , vol.31 , pp. 912-920
    • Colagrande, S.1    Pasquinelli, F.2    Mazzoni, L.N.3
  • 15
    • 84864686885 scopus 로고    scopus 로고
    • Reproductibility of apparent diffusion coefficients measurements in diffusion-weighted MRI of the abdomen with different b values
    • Bilgili MY. Reproductibility of apparent diffusion coefficients measurements in diffusion-weighted MRI of the abdomen with different b values. Eur J Radiol. 2012;81:2066-2068
    • (2012) Eur J Radiol , vol.81 , pp. 2066-2068
    • Bilgili, M.Y.1
  • 16
    • 58149179092 scopus 로고    scopus 로고
    • Liver cirrhosis: Intravoxel incoherent motion MR imagingVpilot study
    • Luciani A, Vignaud A, Cavet M, et al. Liver cirrhosis: Intravoxel incoherent motion MR imagingVpilot study. Radiology. 2008;249:891-899
    • (2008) Radiology , vol.249 , pp. 891-899
    • Luciani, A.1    Vignaud, A.2    Cavet, M.3
  • 17
    • 84861457392 scopus 로고    scopus 로고
    • Effects of microperfusion in hepatic diffusion weighted imaging
    • Dijkstra H, Baron P, Kappert P, et al. Effects of microperfusion in hepatic diffusion weighted imaging. Eur Radiol. 2012;22:891-899
    • (2012) Eur Radiol , vol.22 , pp. 891-899
    • Dijkstra, H.1    Baron, P.2    Kappert, P.3
  • 18
    • 84894033701 scopus 로고    scopus 로고
    • Diffusion analysis with triexponential function in liver cirrhosis
    • Epub ahead of print]
    • Hayashi T, Miyati T, Takahashi J, et al. Diffusion analysis with triexponential function in liver cirrhosis. Radiol Phys Technol. 2013. [Epub ahead of print]
    • (2013) Radiol Phys Technol
    • Hayashi, T.1    Miyati, T.2    Takahashi, J.3
  • 19
    • 80052543682 scopus 로고    scopus 로고
    • Liver magnetic resonance diffusion weighted imaging: 2011 update
    • Chiaradia M, Baranes L, Pigneur F, et al. Liver magnetic resonance diffusion weighted imaging: 2011 update. Clin ResHepatolGastroenterol. 2011;35:539-548
    • (2011) Clin ResHepatolGastroenterol , vol.35 , pp. 539-548
    • Chiaradia, M.1    Baranes, L.2    Pigneur, F.3
  • 20
    • 74949109673 scopus 로고    scopus 로고
    • Diffusion-weighted magnetic resonance imaging of the liver using tracking only navigator echo: Feasibility study
    • Takahara T, Kwee TC, Van Leeuwen MS, et al. Diffusion-weighted magnetic resonance imaging of the liver using tracking only navigator echo: Feasibility study. Invest Radiol. 2010;45:57-63
    • (2010) Invest Radiol , vol.45 , pp. 57-63
    • Takahara, T.1    Kwee, T.C.2    Van Leeuwen, M.S.3
  • 21
    • 74949123772 scopus 로고    scopus 로고
    • Field strength and diffusion encoding technique affect the apparent diffusion coefficient measurements in diffusionweighted imaging of the abdomen
    • Dale BM, Braithwaite AC, Boll DT, et al. Field strength and diffusion encoding technique affect the apparent diffusion coefficient measurements in diffusionweighted imaging of the abdomen. Invest Radiol. 2010;45:104-108
    • (2010) Invest Radiol , vol.45 , pp. 104-108
    • Dale, B.M.1    Braithwaite, A.C.2    Boll, D.T.3
  • 22
    • 33846228820 scopus 로고    scopus 로고
    • Assessment of diffusion-weighted MR imaging in liver fibrosis
    • Annet L, Peeters F, Abarca-Quinones J, et al. Assessment of diffusion-weighted MR imaging in liver fibrosis. J Magn Reson Imaging. 2007;25:122-128
    • (2007) J Magn Reson Imaging , vol.25 , pp. 122-128
    • Annet, L.1    Peeters, F.2    Abarca-Quinones, J.3
  • 23
    • 0022969218 scopus 로고
    • MR imaging of intravoxel incoherent motions: Application to diffusion and perfusion in neurologic disorders
    • Le Bihan D, Breton E, Lallemand D, et al. MR imaging of intravoxel incoherent motions: Application to diffusion and perfusion in neurologic disorders. Radiology. 1986;161:401-407
    • (1986) Radiology , vol.161 , pp. 401-407
    • Le Bihan, D.1    Breton, E.2    Lallemand, D.3
  • 24
    • 0023678634 scopus 로고
    • Separation of diffusion and perfusion in intravoxel incoherent motion MR imaging
    • Le Bihan D, Breton E, Lallemand D, et al. Separation of diffusion and perfusion in intravoxel incoherent motion MR imaging. Radiology. 1988;168:497-505
    • (1988) Radiology , vol.168 , pp. 497-505
    • Le Bihan, D.1    Breton, E.2    Lallemand, D.3
  • 25
    • 77649216180 scopus 로고    scopus 로고
    • Diagnosis of cirrhosis with intravoxel incoherent motion diffusion MRI and dynamic contrast-enhanced MRI alone and in combination: Preliminary experience
    • Patel J, et al. Diagnosis of cirrhosis with intravoxel incoherent motion diffusion MRI and dynamic contrast-enhanced MRI alone and in combination: Preliminary experience. J Magn Reson Imaging. 2010;31:589-600
    • (2010) J Magn Reson Imaging , vol.31 , pp. 589-600
    • Patel, J.1
  • 26
    • 78649980837 scopus 로고    scopus 로고
    • Evaluation of noncirrhotic hepatic parenchyma with and without significant portal vein stenosis using diffusion-weighted echoplanar MR on the basis of multiple-perfusion-components theory
    • Moteki T, Horikoshi H. Evaluation of noncirrhotic hepatic parenchyma with and without significant portal vein stenosis using diffusion-weighted echoplanar MR on the basis of multiple-perfusion-components theory. Magn Reson Imaging. 2011;29:64-73
    • (2011) Magn Reson Imaging , vol.29 , pp. 64-73
    • Moteki, T.1    Horikoshi, H.2
  • 27
    • 79960529109 scopus 로고    scopus 로고
    • Intravoxel incoherent motion in body diffusion-weighted MRI: Reality and challenges
    • Koh DM, Collins DJ, Orton MR. Intravoxel incoherent motion in body diffusion-weighted MRI: Reality and challenges. AJR Am J Roentgenol. 2011;196:1351-1361
    • (2011) AJR Am J Roentgenol , vol.196 , pp. 1351-1361
    • Koh, D.M.1    Collins, D.J.2    Orton, M.R.3
  • 28
    • 0029681669 scopus 로고    scopus 로고
    • Respiratory and postprandial changes in portal flow rate: Assessment by phase contrast MR imaging
    • Sadek AG, Mohamed FB, Outwater EK, et al. Respiratory and postprandial changes in portal flow rate: Assessment by phase contrast MR imaging. J Magn Reson Imaging. 1996;6:90-93
    • (1996) J Magn Reson Imaging , vol.6 , pp. 90-93
    • Sadek, A.G.1    Mohamed, F.B.2    Outwater, E.K.3
  • 29
    • 0020503794 scopus 로고
    • Effect of food on hepatic blood flow: Implications in the food effect phenomenon
    • Svensson CK, Edwards DJ, Mauriello PM, et al. Effect of food on hepatic blood flow: Implications in the food effect phenomenon. Clin Pharmacol Ther. 1983;34:316-323
    • (1983) Clin Pharmacol Ther , vol.34 , pp. 316-323
    • Svensson, C.K.1    Edwards, D.J.2    Mauriello, P.M.3
  • 30
    • 0026548410 scopus 로고
    • Postprandial changes in portal haemodynamics in patients with cirrhosis
    • OBrien S, Keogan M, Patchett S, et al. Postprandial changes in portal haemodynamics in patients with cirrhosis. Gut. 1992;33:364-367
    • (1992) Gut , vol.33 , pp. 364-367
    • O'Brien, S.1    Keogan, M.2    Patchett, S.3
  • 31
    • 0024410498 scopus 로고
    • Effect of meal on portal haemodynamics in healthy humans and in patients with chronic liver disease
    • Gaiani S, Bolondi S, Bassi S, et al. Effect of meal on portal haemodynamics in healthy humans and in patients with chronic liver disease. Hepatology. 1989;9:815-819
    • (1989) Hepatology , vol.9 , pp. 815-819
    • Gaiani, S.1    Bolondi, S.2    Bassi, S.3
  • 32
    • 0025829257 scopus 로고
    • Regulation of postprandial mesenteric blood flow in humans: Evidence for a cholinergic nervous reflex
    • Sieber C, Beglinger C, Jaeger K, et al. Regulation of postprandial mesenteric blood flow in humans: Evidence for a cholinergic nervous reflex. Gut. 1991;32:361-366
    • (1991) Gut , vol.32 , pp. 361-366
    • Sieber, C.1    Beglinger, C.2    Jaeger, K.3
  • 33
    • 73449119276 scopus 로고    scopus 로고
    • Dynamic measurements of total hepatic blood flow with phase contrast MRI
    • Yzet T, Bouzerar R, Baledent O, et al. Dynamic measurements of total hepatic blood flow with phase contrast MRI. Eur J Radiol. 2010;73:119-124
    • (2010) Eur J Radiol , vol.73 , pp. 119-124
    • Yzet, T.1    Bouzerar, R.2    Baledent, O.3
  • 34
    • 77649224323 scopus 로고    scopus 로고
    • Hepatic vascular flow measurements by phase contrast MRI and Doppler echography: A comparative and reproducibility study
    • Yzet T, Bouzerar R, Allart JD, et al. Hepatic vascular flow measurements by phase contrast MRI and Doppler echography: A comparative and reproducibility study. J Magn Reson Imaging. 2010;31:579-588
    • (2010) J Magn Reson Imaging , vol.31 , pp. 579-588
    • Yzet, T.1    Bouzerar, R.2    Allart, J.D.3
  • 35
    • 36248985628 scopus 로고    scopus 로고
    • Hepatic pseudo-Anisotropy: A specific artefact in hepatic diffusion-weighted images obtained with respiratory triggering
    • Nasu K, Kuroki Y, Fujii H, et al. Hepatic pseudo-Anisotropy: A specific artefact in hepatic diffusion-weighted images obtained with respiratory triggering. MAGMA. 2007;20:205-211
    • (2007) MAGMA , vol.20 , pp. 205-211
    • Nasu, K.1    Kuroki, Y.2    Fujii, H.3
  • 36
    • 0036082536 scopus 로고    scopus 로고
    • Abdomen: Diffusion-weighted MR imaging with pulse-Triggered single-shot sequences
    • Mürtz P, Flacke S, Träber F, et al. Abdomen: Diffusion-weighted MR imaging with pulse-Triggered single-shot sequences. Radiology. 2002;224:258-264
    • (2002) Radiology , vol.224 , pp. 258-264
    • Mürtz, P.1    Flacke, S.2    Träber, F.3
  • 37
    • 75149161839 scopus 로고    scopus 로고
    • Influence of cardiac motion on diffusionweighted magnetic resonance imaging of the liver
    • Kwee TC, Takahara T, Niwa T, et al. Influence of cardiac motion on diffusionweighted magnetic resonance imaging of the liver. MAGMA. 2009;22:319-325
    • (2009) MAGMA , vol.22 , pp. 319-325
    • Kwee, T.C.1    Takahara, T.2    Niwa, T.3
  • 38
    • 84894043266 scopus 로고    scopus 로고
    • CpČížek, Pavel (2004) : (Non, Center for Applied Statistics and Economics (CASE), No
    • cp.Čížek, Pavel (2004) : (Non) Linear Regression Modeling, Papers/Humboldt-Universität Berlin, Center for Applied Statistics and Economics (CASE), No. 2004,11, http://hdl.handle.net/10419/22185
    • (2004) Linear Regression Modeling, Papers/Humboldt-Universität Berlin , vol.11
  • 39
    • 0029850075 scopus 로고    scopus 로고
    • Postprandial splanchnic hemodynamic response in patients with cirrhosis of the liver: Evaluation with triple-vessel duplex us
    • Iwao T, Toyonaga A, Oho K, et al. Postprandial splanchnic hemodynamic response in patients with cirrhosis of the liver: Evaluation with triple-vessel duplex US. Radiology. 1996;201:711-715
    • (1996) Radiology , vol.201 , pp. 711-715
    • Iwao, T.1    Toyonaga, A.2    Oho, K.3
  • 40
    • 0030940166 scopus 로고    scopus 로고
    • Effect of fasting and food intake on magnetization transfer of human liver tissue
    • Salo S, Alanen A, Komu M, et al. Effect of fasting and food intake on magnetization transfer of human liver tissue. Magn Reson Imaging. 1997;15:47-50
    • (1997) Magn Reson Imaging , vol.15 , pp. 47-50
    • Salo, S.1    Alanen, A.2    Komu, M.3
  • 41
    • 0020032895 scopus 로고
    • Relative contribution of fat, protein, carbohydrate, and ethanol to intestinal hyperemia
    • Siregar H, Chou CC. Relative contribution of fat, protein, carbohydrate, and ethanol to intestinal hyperemia. Am J Physiol. 1982;242:G27-G31
    • (1982) Am J Physiol , vol.242
    • Siregar, H.1    Chou, C.C.2
  • 42
    • 0026548030 scopus 로고
    • Intestinal phase of superior mesenteric artery blood flow in man
    • Sieber C, Beglinger C, Jäger K, Stalder GA. Intestinal phase of superior mesenteric artery blood flow in man. Gut. 1992;33:497-501
    • (1992) Gut , vol.33 , pp. 497-501
    • Sieber, C.1    Beglinger, C.2    Jäger, K.3    Stalder, G.A.4
  • 43
    • 0023866437 scopus 로고
    • Effects of ingestion of carbohydrate, fat, protein, and water on the mesenteric blood flow in man
    • Qamar MI, Read AE. Effects of ingestion of carbohydrate, fat, protein, and water on the mesenteric blood flow in man. Scand J Gastroenterol. 1988;23:26-30
    • (1988) Scand J Gastroenterol , vol.23 , pp. 26-30
    • Qamar, M.I.1    Read, A.E.2
  • 44
    • 63849179148 scopus 로고    scopus 로고
    • Respiratory-Triggered versus breath-hold diffusion-weighted MRI of liver lesions: Comparison of image quality and apparent diffusion coefficient values
    • Kandpal H, Sharma R, Madhusudhan KS, et al. Respiratory-Triggered versus breath-hold diffusion-weighted MRI of liver lesions: Comparison of image quality and apparent diffusion coefficient values. AJR Am J Roentgenol. 2009;192:915-922
    • (2009) AJR Am J Roentgenol , vol.192 , pp. 915-922
    • Kandpal, H.1    Sharma, R.2    Madhusudhan, K.S.3
  • 45
    • 55749097922 scopus 로고    scopus 로고
    • Comparison and reproducibility of ADC measurements in breathhold, respiratory triggered, and free-breathing diffusionweighted MR imaging of the liver
    • Kwee TC, Takahara T, Koh DM, et al. Comparison and reproducibility of ADC measurements in breathhold, respiratory triggered, and free-breathing diffusionweighted MR imaging of the liver. J Magn Reson Imaging. 2008;28:1141-1148
    • (2008) J Magn Reson Imaging , vol.28 , pp. 1141-1148
    • Kwee, T.C.1    Takahara, T.2    Koh, D.M.3
  • 46
    • 33748933680 scopus 로고    scopus 로고
    • Measurement of the apparent diffusion coefficient in the liver: Is it a reliable index for hepatic disease diagnosis
    • Nasu K, Kuroki Y, Sekiguchi R, et al. Measurement of the apparent diffusion coefficient in the liver: Is it a reliable index for hepatic disease diagnosis? Radiat Med. 2006;24:438-444
    • (2006) Radiat Med , vol.24 , pp. 438-444
    • Nasu, K.1    Kuroki, Y.2    Sekiguchi, R.3
  • 47
    • 34249874331 scopus 로고    scopus 로고
    • Diffusion-weighted MRI in the body: Applications and challenges in oncology
    • Koh DM, Collins DJ. Diffusion-weighted MRI in the body: Applications and challenges in oncology. AJR Am J Roentgenol. 2007;188:1622-1635
    • (2007) AJR Am J Roentgenol , vol.188 , pp. 1622-1635
    • Koh, D.M.1    Collins, D.J.2
  • 48
    • 33645514999 scopus 로고    scopus 로고
    • Influence of perfusion on hepatic MR diffusion measurement
    • Hollingsworth KG, Lomas DJ. Influence of perfusion on hepatic MR diffusion measurement. NMR Biomed. 2006;19:231-235
    • (2006) NMR Biomed , vol.19 , pp. 231-235
    • Hollingsworth, K.G.1    Lomas, D.J.2
  • 49
    • 0020592142 scopus 로고    scopus 로고
    • Relationship between hepatic blood flow and overall metabolism: The hepatic arterial buffer response
    • Lautt WW. Relationship between hepatic blood flow and overall metabolism: The hepatic arterial buffer response. Fed Proc. 1983;42:1662-1666
    • Fed Proc , vol.1983 , Issue.42 , pp. 1662-1666
    • Lautt, W.W.1
  • 50
    • 0023640594 scopus 로고
    • Conceptual review of the hepatic vascular bed
    • Lautt WW, Greenway CV. Conceptual review of the hepatic vascular bed. Hepatology. 1987;7:952-963
    • (1987) Hepatology , vol.7 , pp. 952-963
    • Lautt, W.W.1    Greenway, C.V.2
  • 51
    • 0026080019 scopus 로고
    • Hepatic microvascular regulatory mechanisms xi effects of serotonin on intralobular perfusion and volumetric flowrates at the inlet of periportal and outlet of centrivenous sinusoids
    • Blankenship LL Jr, Cilento EV, Reilly FD. Hepatic microvascular regulatory mechanisms. XI. Effects of serotonin on intralobular perfusion and volumetric flowrates at the inlet of periportal and outlet of centrivenous sinusoids. Microcirc Endothelium Lymphatics. 1991;7:57-75
    • (1991) Microcirc Endothelium Lymphatics , vol.7 , pp. 57-75
    • Blankenship Jr., L.L.1    Cilento, E.V.2    Reilly, F.D.3
  • 53
    • 0019515599 scopus 로고
    • Hepatic microvascular regulatory mechanisms i adrenergic mechanisms
    • Reilly FD, McCuskey RS, Cilento EV. Hepatic microvascular regulatory mechanisms. I. Adrenergic mechanisms. Microvasc Res. 1981;21:103-116
    • (1981) Microvasc Res , vol.21 , pp. 103-116
    • Reilly, F.D.1    McCuskey, R.S.2    Cilento, E.V.3
  • 54
    • 74249107370 scopus 로고    scopus 로고
    • Magnetic resonance measurement of diffusion in the abdomen
    • Perman WH, Balci NC, Akduman I, et al. Magnetic resonance measurement of diffusion in the abdomen. Top Magn Reson Imaging. 2009;20:99-104
    • (2009) Top Magn Reson Imaging , vol.20 , pp. 99-104
    • Perman, W.H.1    Balci, N.C.2    Akduman, I.3
  • 55
    • 47249161179 scopus 로고    scopus 로고
    • Liver imaging at 3.0 T: Diffusion-induced black-blood echo-planar imaging with large anatomic volumetric coverage as an alternative for specific absorption rate-intensive echotrain spin-echo sequences: Feasibility study
    • Van Den Bos IC, Hussain SM, Krestin GP, et al. Liver imaging at 3.0 T: Diffusion-induced black-blood echo-planar imaging with large anatomic volumetric coverage as an alternative for specific absorption rate-intensive echotrain spin-echo sequences: Feasibility study. Radiology. 2008;248:264-271
    • (2008) Radiology , vol.248 , pp. 264-271
    • Van Den Bos, I.C.1    Hussain, S.M.2    Krestin, G.P.3
  • 56
    • 84861092311 scopus 로고    scopus 로고
    • Hepatic fat quantification: A prospective comparison of magnetic resonance spectroscopy and analysis methods for chemical-shift gradient echo magnetic resonance imaging with histologic assessment as the reference standard
    • Kang BK, Yu ES, Lee SS, et al. Hepatic fat quantification: A prospective comparison of magnetic resonance spectroscopy and analysis methods for chemical-shift gradient echo magnetic resonance imaging with histologic assessment as the reference standard. Invest Radiol. 2012;47:368-375
    • (2012) Invest Radiol , vol.47 , pp. 368-375
    • Kang, B.K.1    Yu, E.S.2    Lee, S.S.3
  • 57
    • 81855169989 scopus 로고    scopus 로고
    • Noninvasive quantification of hepatic fat content using three-echo dixon magnetic resonance imaging with correction for T2 relaxation effects
    • Kuhn JP, Evert M, Friedrich N, et al. Noninvasive quantification of hepatic fat content using three-echo dixon magnetic resonance imaging with correction for T2 relaxation effects. Invest Radiol. 2011;46:783-789
    • (2011) Invest Radiol , vol.46 , pp. 783-789
    • Kuhn, J.P.1    Evert, M.2    Friedrich, N.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.