-
1
-
-
0022969218
-
Mr imaging of intravoxel incoherent motions: Application to diffusion and perfusion in neurologic disorders
-
Le Bihan D, Breton E, Lallemand D, Grenier P, Cabanis E, Laval- Jeantet M (1986) MR imaging of intravoxel incoherent motions: application to diffusion and perfusion in neurologic disorders. Radiology 161:401-407
-
(1986)
Radiology
, vol.161
, pp. 401-407
-
-
Le Bihan, D.1
Breton, E.2
Lallemand, D.3
Grenier, P.4
Cabanis, E.5
Laval- Jeantet, M.6
-
2
-
-
0023678634
-
Separation of diffusion and perfusion in intravoxel incoherent motion mr imaging
-
Le Bihan D, Breton E, Lallemand D, Aubin ML, Vignaud J, Laval-Jeantet M (1988) Separation of diffusion and perfusion in intravoxel incoherent motion MR imaging. Radiology 168:497-505
-
(1988)
Radiology
, vol.168
, pp. 497-505
-
-
Le Bihan, D.1
Breton, E.2
Lallemand, D.3
Aubin, M.L.4
Vignaud, J.5
Laval-Jeantet, M.6
-
3
-
-
0025718336
-
Imaging of diffusion and microcirculation with gradient sensitization: Design, strategy, and significance
-
Le Bihan D, Turner R, Moonen CT, Pekar J (1991) Imaging of diffusion and microcirculation with gradient sensitization: design, strategy, and significance. J Magn Reson Imaging 1:7-28
-
(1991)
J Magn Reson Imaging
, vol.1
, pp. 7-28
-
-
Le Bihan, D.1
Turner, R.2
Moonen, C.T.3
Pekar, J.4
-
4
-
-
0028118461
-
Abdominal diffusion mapping with use of a whole-body echo-planar system
-
Müller MF, Prasad P, Siewert B, Nissenbaum MA, Raptopoulos V, Edelman RR (1994) Abdominal diffusion mapping with use of a whole-body echo-planar system. Radiology 190:475-478
-
(1994)
Radiology
, vol.190
, pp. 475-478
-
-
Müller, M.F.1
Prasad, P.2
Siewert, B.3
Nissenbaum, M.A.4
Raptopoulos, V.5
Edelman, R.R.6
-
5
-
-
0025049046
-
Echo-planar imaging of intravoxel incoherent motion
-
Turner R, Le Bihan D, Maier J, Vavrek R, Hedges LK, Pekar J (1990) Echo-planar imaging of intravoxel incoherent motion. Radiology 177:407-414
-
(1990)
Radiology
, vol.177
, pp. 407-414
-
-
Turner, R.1
Le Bihan, D.2
Maier, J.3
Vavrek, R.4
Hedges, L.K.5
Pekar, J.6
-
6
-
-
0030766670
-
Focal liver masses: Characterization with diffusion-weighted echoplanar mr imaging
-
Namimoto T, Yamashita Y, Sumi S, Tang Y, Takahashi M (1997) Focal liver masses: characterization with diffusion-weighted echoplanar MR imaging. Radiology 204:739-744
-
(1997)
Radiology
, vol.204
, pp. 739-744
-
-
Namimoto, T.1
Yamashita, Y.2
Sumi, S.3
Tang, Y.4
Takahashi, M.5
-
7
-
-
0032875761
-
Diffusion-weighted mr imaging with single-shot echo-planar imaging in the upper abdomen: Preliminary clinical experience in 61 patients
-
Ichikawa T, Haradome H, Hachiya J, Nitatori T, Araki T (1999) Diffusion-weighted MR imaging with single-shot echo-planar imaging in the upper abdomen: preliminary clinical experience in 61 patients. Abdom Imaging 24:456-461
-
(1999)
Abdom Imaging
, vol.24
, pp. 456-461
-
-
Ichikawa, T.1
Haradome, H.2
Hachiya, J.3
Nitatori, T.4
Araki, T.5
-
8
-
-
0032800447
-
Diffusion-weighted single-shot echoplanar mr imaging for liver disease
-
Kim T, Murakami T, Takahashi S, Hori M, Tsuda K, Nakamura H (1999) Diffusion-weighted single-shot echoplanar MR imaging for liver disease. AJR Am J Roentgenol 173:393-398
-
(1999)
AJR Am J Roentgenol
, vol.173
, pp. 393-398
-
-
Kim, T.1
Murakami, T.2
Takahashi, S.3
Hori, M.4
Tsuda, K.5
Nakamura, H.6
-
9
-
-
0032975435
-
Diffusion coefficients in abdominal organs and hepatic lesions: Evaluation with intravoxel incoherent motion echo-planar mr imaging
-
Yamada I, Aung W, Himeno Y, Nakagawa T, Shibuya H (1999) Diffusion coefficients in abdominal organs and hepatic lesions: evaluation with intravoxel incoherent motion echo-planar MR imaging. Radiology 210:617-623
-
(1999)
Radiology
, vol.210
, pp. 617-623
-
-
Yamada, I.1
Aung, W.2
Himeno, Y.3
Nakagawa, T.4
Shibuya, H.5
-
10
-
-
0036234399
-
Evaluation of hepatic lesions and hepatic parenchyma using diffusionweighted reordered turboflash magnetic resonance images
-
Moteki T, Horikoshi H, Oya N, Aoki J, Endo K (2002) Evaluation of hepatic lesions and hepatic parenchyma using diffusionweighted reordered turboFLASH magnetic resonance images. J Magn Reson Imaging 15:564-572
-
(2002)
J Magn Reson Imaging
, vol.15
, pp. 564-572
-
-
Moteki, T.1
Horikoshi, H.2
Oya, N.3
Aoki, J.4
Endo, K.5
-
11
-
-
33748264591
-
Evaluation of hepatic lesions and hepatic parenchyma using diffusion-weighted echo-planar mr with three values of gradient b-factor
-
Moteki T, Horikoshi H (2006) Evaluation of hepatic lesions and hepatic parenchyma using diffusion-weighted echo-planar MR with three values of gradient b-factor. J Magn Reson Imaging 24:637-645
-
(2006)
J Magn Reson Imaging
, vol.24
, pp. 637-645
-
-
Moteki, T.1
Horikoshi, H.2
-
12
-
-
58149518020
-
Evaluation of true diffusion, perfusion factor, and apparent diffusion coefficient in non-necrotic liver metastases and uncomplicated liver hemangiomas using black-blood echo planar imaging
-
Coenegrachts K, Delanote J, Ter Beek L et al (2009) Evaluation of true diffusion, perfusion factor, and apparent diffusion coefficient in non-necrotic liver metastases and uncomplicated liver hemangiomas using black-blood echo planar imaging. Eur J Radiol 69:131-138
-
(2009)
Eur J Radiol
, vol.69
, pp. 131-138
-
-
Coenegrachts, K.1
Delanote, J.2
Ter Beek, L.3
-
13
-
-
58149179092
-
Liver cirrhosis: Intravoxel incoherent motion mr imaging-pilot study
-
Luciani A, Vignaud A, Cavet M et al (2008) Liver cirrhosis: intravoxel incoherent motion MR imaging-pilot study. Radiology 249:891-899
-
(2008)
Radiology
, vol.249
, pp. 891-899
-
-
Luciani, A.1
Vignaud, A.2
Cavet, M.3
-
14
-
-
78649980837
-
Evaluation of noncirrhotic hepatic parenchyma with and without significant portal vein stenosis using diffusion-weighted echo-planar mr on the basis of multiple-perfusion-components theory
-
Moteki T, Horikoshi H (2011) Evaluation of noncirrhotic hepatic parenchyma with and without significant portal vein stenosis using diffusion-weighted echo-planar MR on the basis of multiple-perfusion-components theory. Magn Reson Imaging 29:64-73
-
(2011)
Magn Reson Imaging
, vol.29
, pp. 64-73
-
-
Moteki, T.1
Horikoshi, H.2
-
15
-
-
75349104448
-
Diffusion-weighted mr imaging of the liver
-
Taouli B, Koh DM (2010) Diffusion-weighted MR imaging of the liver. Radiology 254:47-66
-
(2010)
Radiology
, vol.254
, pp. 47-66
-
-
Taouli, B.1
Koh, D.M.2
-
16
-
-
0037257050
-
Evaluation of liver diffusion isotropy and characterization of focal hepatic lesions with two single-shot echoplanar mr imaging sequences: Prospective study in 66 patients
-
Taouli B, Vilgrain V, Dumont E, Daire JL, Fan B, Menu Y (2003) Evaluation of liver diffusion isotropy and characterization of focal hepatic lesions with two single-shot echoplanar MR imaging sequences: prospective study in 66 patients. Radiology 226:71-78
-
(2003)
Radiology
, vol.226
, pp. 71-78
-
-
Taouli, B.1
Vilgrain, V.2
Dumont, E.3
Daire, J.L.4
Fan, B.5
Menu, Y.6
-
17
-
-
38649113882
-
Magnetic resonance imaging of hepatic fibrosis: Emerging clinical applications
-
Talwalkar JA, Yin M, Fidler JL, Sanderson SO, Kamath PS, Ehman RL (2008) Magnetic resonance imaging of hepatic fibrosis: emerging clinical applications. Hepatology 47:332-342
-
(2008)
Hepatology
, vol.47
, pp. 332-342
-
-
Talwalkar, J.A.1
Yin, M.2
Fidler, J.L.3
Sanderson, S.O.4
Kamath, P.S.5
Ehman, R.L.6
-
18
-
-
0035118869
-
Diffusion-weighted mr imaging of the liver: Distinguishing hepatic abscess from cystic or necrotic tumor
-
Chan JH, Tsui EY, Luk SH et al (2001) Diffusion-weighted MR imaging of the liver: distinguishing hepatic abscess from cystic or necrotic tumor. Abdom Imaging 26:161-165
-
(2001)
Abdom Imaging
, vol.26
, pp. 161-165
-
-
Chan, J.H.1
Tsui, E.Y.2
Luk, S.H.3
-
19
-
-
0036082536
-
Abdomen: Diffusion-weighted mr imaging with pulse-triggered single-shot sequences
-
Mürtz P, Flacke S, Träber F, van den Brink JS, Gieseke J, Schild HH (2002) Abdomen: diffusion-weighted MR imaging with pulse-triggered single-shot sequences. Radiology 224:258-264
-
(2002)
Radiology
, vol.224
, pp. 258-264
-
-
Mürtz, P.1
Flacke, S.2
Träber, F.3
Van Den Brink, J.S.4
Gieseke, J.5
Schild, H.H.6
-
20
-
-
0041629178
-
Diffusionweighted mr imaging of the liver of hepatitis c patients
-
Boulanger Y, Amara M, Lepanto L et al (2003) Diffusionweighted MR imaging of the liver of hepatitis C patients. NMR Biomed 16:132-136
-
(2003)
NMR Biomed
, vol.16
, pp. 132-136
-
-
Boulanger, Y.1
Amara, M.2
Lepanto, L.3
-
21
-
-
39049083433
-
Characterization of focal liver lesions by adc measurements using a respiratory triggered diffusion-weighted single-shot echo-planar mr imaging technique
-
Bruegel M, Holzapfel K, Gaa J et al (2008) Characterization of focal liver lesions by ADC measurements using a respiratory triggered diffusion-weighted single-shot echo-planar MR imaging technique. Eur Radiol 18:477-485
-
(2008)
Eur Radiol
, vol.18
, pp. 477-485
-
-
Bruegel, M.1
Holzapfel, K.2
Gaa, J.3
-
23
-
-
73449098202
-
Value of diffusion-weighted mri for assessing liver fibrosis and cirrhosis
-
Sandrasegaran K, Akisik FM, Lin C et al (2009) Value of diffusion-weighted MRI for assessing liver fibrosis and cirrhosis. AJR Am J Roentgenol 193:1556-1560
-
(2009)
AJR Am J Roentgenol
, vol.193
, pp. 1556-1560
-
-
Sandrasegaran, K.1
Akisik, F.M.2
Lin, C.3
-
24
-
-
74949123772
-
Field strength and diffusion encoding technique affect the apparent diffusion coefficient measurements in diffusion-weighted imaging of the abdomen
-
Dale BM, Braithwaite AC, Boll DT, Merkle EM (2010) Field strength and diffusion encoding technique affect the apparent diffusion coefficient measurements in diffusion-weighted imaging of the abdomen. Invest Radiol 45:104-108
-
(2010)
Invest Radiol
, vol.45
, pp. 104-108
-
-
Dale, B.M.1
Braithwaite, A.C.2
Boll, D.T.3
Merkle, E.M.4
-
25
-
-
33748933680
-
Measurement of the apparent diffusion coefficient in the liver: Is it a reliable index for hepatic disease diagnosis?
-
Nasu K, Kuroki Y, Sekiguchi R, Kazama T, Nakajima H (2006) Measurement of the apparent diffusion coefficient in the liver: is it a reliable index for hepatic disease diagnosis? Radiat Med 24:438-444
-
(2006)
Radiat Med
, vol.24
, pp. 438-444
-
-
Nasu, K.1
Kuroki, Y.2
Sekiguchi, R.3
Kazama, T.4
Nakajima, H.5
-
26
-
-
48949117583
-
Non-breath-hold high b-value diffusion-weighted mri with parallel imaging technique: Apparent diffusion coefficient determination in normal abdominal organs
-
Kiliçkesmez O, Yirik G, Bayramoglu S, Cimilli T, Aydin S (2008) Non-breath-hold high b-value diffusion-weighted MRI with parallel imaging technique: apparent diffusion coefficient determination in normal abdominal organs. Diagn Interv Radiol 14:83-87
-
(2008)
Diagn Interv Radiol
, vol.14
, pp. 83-87
-
-
Kiliçkesmez, O.1
Yirik, G.2
Bayramoglu, S.3
Cimilli, T.4
Aydin, S.5
-
27
-
-
84859912267
-
-
MATLAB Central File Exchange. Available via. Accessed 4 May 2011
-
D'Errico J (2006) Understanding fminsearchbnd, MATLAB Central File Exchange. Available via http://www.mathworks. com/matlabcentral/fileexchange/ 8277-fminsearchbnd. Accessed 4 May 2011
-
(2006)
Understanding Fminsearchbnd
-
-
D'Errico, J.1
-
28
-
-
0032251894
-
Convergence properties of the nelder-mead simplex method in low dimensions
-
Lagarias JC, Reeds JA, Wright MH, Wright PE (1998) Convergence properties of the Nelder-Mead Simplex method in low dimensions. SIAM J Optim 9:112-147
-
(1998)
SIAM J Optim
, vol.9
, pp. 112-147
-
-
Lagarias, J.C.1
Reeds, J.A.2
Wright, M.H.3
Wright, P.E.4
-
29
-
-
84950646761
-
The influence curve and its role in robust estimation
-
Hampel FR (1974) The influence curve and its role in robust estimation. J Am Statist Assoc 69:383-393
-
(1974)
J Am Statist Assoc
, vol.69
, pp. 383-393
-
-
Hampel, F.R.1
-
30
-
-
33751225105
-
Adc measurement of abdominal organs and lesions using parallel imaging technique
-
Yoshikawa T, Kawamitsu H, Mitchell DG et al (2006) ADC measurement of abdominal organs and lesions using parallel imaging technique. AJR Am J Roentgenol 187:1521-1530
-
(2006)
AJR Am J Roentgenol
, vol.187
, pp. 1521-1530
-
-
Yoshikawa, T.1
Kawamitsu, H.2
Mitchell, D.G.3
-
31
-
-
79751534432
-
Liver diffusion-weighted mr imaging: The tower of babel?
-
Guiu B, Cercueil JP (2011) Liver diffusion-weighted MR imaging: the tower of Babel? Eur Radiol 21:463-467
-
(2011)
Eur Radiol
, vol.21
, pp. 463-467
-
-
Guiu, B.1
Cercueil, J.P.2
-
33
-
-
77951590693
-
Diffusion-weighted imaging of normal fibroglandular breast tissue: Influence of microperfusion and fat suppression technique on the apparent diffusion coefficient
-
Baron P, Dorrius MD, Kappert P, Oudkerk M, Sijens PE (2010) Diffusion-weighted imaging of normal fibroglandular breast tissue: influence of microperfusion and fat suppression technique on the apparent diffusion coefficient. NMR Biomed 23:399-405
-
(2010)
NMR Biomed
, vol.23
, pp. 399-405
-
-
Baron, P.1
Dorrius, M.D.2
Kappert, P.3
Oudkerk, M.4
Sijens, P.E.5
-
34
-
-
61349123591
-
Diffusion-weighted magnetic resonance imaging as a cancer biomarker: Consensus and recommendations
-
Padhani AR, Liu G, Koh DM et al (2009) Diffusion-weighted magnetic resonance imaging as a cancer biomarker: consensus and recommendations. Neoplasia 11:102-125
-
(2009)
Neoplasia
, vol.11
, pp. 102-125
-
-
Padhani, A.R.1
Liu, G.2
Koh, D.M.3
-
35
-
-
77950143207
-
Variability of renal apparent diffusion coefficients: Limitations of the monoexponential model for diffusion quantification
-
Zhang JL, Sigmund EE, Chandarana H et al (2010) Variability of renal apparent diffusion coefficients: limitations of the monoexponential model for diffusion quantification. Radiology 254:783-792
-
(2010)
Radiology
, vol.254
, pp. 783-792
-
-
Zhang, J.L.1
Sigmund, E.E.2
Chandarana, H.3
-
36
-
-
33746880243
-
Colorectal hepatic metastases: Quantitative measurements using single-shot echoplanar diffusion-weighted mr imaging
-
Koh DM, Scurr E, Collins DJ et al (2006) Colorectal hepatic metastases: quantitative measurements using single-shot echoplanar diffusion-weighted MR imaging. Eur Radiol 16:1898-1905
-
(2006)
Eur Radiol
, vol.16
, pp. 1898-1905
-
-
Koh, D.M.1
Scurr, E.2
Collins, D.J.3
-
37
-
-
63849179148
-
Respiratory-triggered versus breath-hold diffusion-weighted mri of liver lesions: Comparison of image quality and apparent diffusion coefficient values
-
Kandpal H, Sharma R, Madhusudhan KS, Kapoor KS (2009) Respiratory-triggered versus breath-hold diffusion-weighted MRI of liver lesions: comparison of image quality and apparent diffusion coefficient values. AJR Am J Roentgenol 192:915-922
-
(2009)
AJR Am J Roentgenol
, vol.192
, pp. 915-922
-
-
Kandpal, H.1
Sharma, R.2
Madhusudhan, K.S.3
Kapoor, K.S.4
-
38
-
-
75149161839
-
Influence of cardiac motion on diffusion-weighted magnetic resonance imaging of the liver
-
Kwee TC, Takahara T, Niwa T et al (2009) Influence of cardiac motion on diffusion-weighted magnetic resonance imaging of the liver. MAGMA 22:319-325
-
(2009)
MAGMA
, vol.22
, pp. 319-325
-
-
Kwee, T.C.1
Takahara, T.2
Niwa, T.3
-
39
-
-
36248985628
-
Hepatic pseudo-anisotropy: A specific artifact in hepatic diffusionweighted images obtained with respiratory triggering
-
Nasu K, Kuroki Y, Fujii H, Minami M (2007) Hepatic pseudo-anisotropy: a specific artifact in hepatic diffusionweighted images obtained with respiratory triggering. MAGMA 20:205-211
-
(2007)
MAGMA
, vol.20
, pp. 205-211
-
-
Nasu, K.1
Kuroki, Y.2
Fujii, H.3
Minami, M.4
-
40
-
-
79551633556
-
Features of eight segments of liver perfusion with the second generation dual-source computed tomography
-
Su BY, Jin ZY, Liu W et al (2010) Features of eight segments of liver perfusion with the second generation dual-source computed tomography. Acta Acad Med Sin 32:655-658
-
(2010)
Acta Acad Med Sin
, vol.32
, pp. 655-658
-
-
Su, B.Y.1
Jin, Z.Y.2
Liu, W.3
-
41
-
-
33947108448
-
Assessment of hepatic perfusion in transplanted livers by pharmacokinetic analysis of dynamic magnetic resonance measurements
-
Scharf J, Kemmling A, Hess T, Mehrabi A, Kauffmann G, Groden C, Brix G (2007) Assessment of hepatic perfusion in transplanted livers by pharmacokinetic analysis of dynamic magnetic resonance measurements. Invest Radiol 42:224-229
-
(2007)
Invest Radiol
, vol.42
, pp. 224-229
-
-
Scharf, J.1
Kemmling, A.2
Hess, T.3
Mehrabi, A.4
Kauffmann, G.5
Groden, C.6
Brix, G.7
-
42
-
-
77955854101
-
Hepatic perfusion changes in an experimental model of acute pancreatitis: Evaluation by perfusion ct
-
Tutcu S, Serter S, Kaya Y, Kara E, Nese N, Pekindil G, Coskun T (2010) Hepatic perfusion changes in an experimental model of acute pancreatitis: evaluation by perfusion CT. Eur J Radiol 75:203-206
-
(2010)
Eur J Radiol
, vol.75
, pp. 203-206
-
-
Tutcu, S.1
Serter, S.2
Kaya, Y.3
Kara, E.4
Nese, N.5
Pekindil, G.6
Coskun, T.7
-
43
-
-
24644438250
-
Age-related changes in liver structure and function: Implications for disease?
-
Schmucker DL (2005) Age-related changes in liver structure and function: implications for disease? Exp Gerontol 40:650-659
-
(2005)
Exp Gerontol
, vol.40
, pp. 650-659
-
-
Schmucker, D.L.1
-
45
-
-
79959268185
-
Magnetic resonance diffusion-weighted imaging: Quantitative evaluation of age-related changes in healthy liver parenchyma
-
Pasquinelli F, Belli G, Mazzoni LN, Grazioli L, Colagrande S (2011) Magnetic resonance diffusion-weighted imaging: quantitative evaluation of age-related changes in healthy liver parenchyma. Magn Reson Imaging 29:805-812
-
(2011)
Magn Reson Imaging
, vol.29
, pp. 805-812
-
-
Pasquinelli, F.1
Belli, G.2
Mazzoni, L.N.3
Grazioli, L.4
Colagrande, S.5
-
46
-
-
39149092066
-
Respiratory gated diffusion-weighted imaging of the liver: Value of apparent diffusion coefficient measurements in the differentiation between most commonly encountered benign and malignant focal liver lesions
-
Gourtsoyianni S, Papanikolaou N, Yarmenitis S, Maris T, Karantanas A, Gourtsoyiannis N (2008) Respiratory gated diffusion-weighted imaging of the liver: value of apparent diffusion coefficient measurements in the differentiation between most commonly encountered benign and malignant focal liver lesions. Eur Radiol 18:486-492
-
(2008)
Eur Radiol
, vol.18
, pp. 486-492
-
-
Gourtsoyianni, S.1
Papanikolaou, N.2
Yarmenitis, S.3
Maris, T.4
Karantanas, A.5
Gourtsoyiannis, N.6
|