메뉴 건너뛰기




Volumn 292, Issue , 2014, Pages 843-851

Drug release from porous silicon for stable neural interface

Author keywords

Dexamethasone; Drug release; Neural interface; Porous silicon; Primary astrocyte

Indexed keywords

CONTROLLED DRUG DELIVERY; DEGRADATION; DRUG PRODUCTS; IMAGE ENHANCEMENT; MICROELECTRODES; PORE SIZE; POROUS SILICON; SILICON WAFERS; TISSUE;

EID: 84893652163     PISSN: 01694332     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.apsusc.2013.12.060     Document Type: Article
Times cited : (11)

References (34)
  • 1
    • 0035905783 scopus 로고    scopus 로고
    • Actions from thoughts
    • M.A.L. Nicolelis Actions from thoughts Nature 409 2001 403 407
    • (2001) Nature , vol.409 , pp. 403-407
    • Nicolelis, M.A.L.1
  • 2
    • 33749062944 scopus 로고    scopus 로고
    • Brain-controlled interfaces: Movement restoration with neural prosthetics
    • A.B. Schwartz, X.T. Cui, D.J. Weber, and D.W. Moran Brain-controlled interfaces: movement restoration with neural prosthetics Neuron 52 2006 205 220
    • (2006) Neuron , vol.52 , pp. 205-220
    • Schwartz, A.B.1    Cui, X.T.2    Weber, D.J.3    Moran, D.W.4
  • 3
    • 0033485808 scopus 로고    scopus 로고
    • Long-term neural recording characteristics of wire microelectrode arrays implanted in cerebral cortex
    • J.C. Williams, R.L. Rennaker, and D.R. Kipke Long-term neural recording characteristics of wire microelectrode arrays implanted in cerebral cortex Brain Research Protocols 4 1999 303 313
    • (1999) Brain Research Protocols , vol.4 , pp. 303-313
    • Williams, J.C.1    Rennaker, R.L.2    Kipke, D.R.3
  • 5
    • 79954552027 scopus 로고    scopus 로고
    • Neural control of cursor trajectory and click by a human with tetraplegia 1000 days after implant of an intracortical microelectrode array
    • J.D. Simeral, S.P. Kim, M.J. Black, J.P. Donoghue, and L.R. Hochberg Neural control of cursor trajectory and click by a human with tetraplegia 1000 days after implant of an intracortical microelectrode array Journal of Neural Engineering 8 2011 025027
    • (2011) Journal of Neural Engineering , vol.8 , pp. 025027
    • Simeral, J.D.1    Kim, S.P.2    Black, M.J.3    Donoghue, J.P.4    Hochberg, L.R.5
  • 7
    • 78549231224 scopus 로고    scopus 로고
    • The surface immobilization of the neural adhesion molecule L1 on neural probes and its effect on neuronal density and gliosis at the probe/tissue interface
    • E. Azemi, C.F. Lagenaur, and X.T. Cui The surface immobilization of the neural adhesion molecule L1 on neural probes and its effect on neuronal density and gliosis at the probe/tissue interface Biomaterials 32 2011 681 692
    • (2011) Biomaterials , vol.32 , pp. 681-692
    • Azemi, E.1    Lagenaur, C.F.2    Cui, X.T.3
  • 9
    • 67349233067 scopus 로고    scopus 로고
    • Porous silicon as a potential electrode material in a nerve repair setting: Tissue reactions
    • F. Johansson, L. Wallman, N. Danielsen, J. Schouenborg, and M. Kanie Porous silicon as a potential electrode material in a nerve repair setting: tissue reactions Acta Biomaterialia 5 2009 2230 2237
    • (2009) Acta Biomaterialia , vol.5 , pp. 2230-2237
    • Johansson, F.1    Wallman, L.2    Danielsen, N.3    Schouenborg, J.4    Kanie, M.5
  • 10
    • 84875405021 scopus 로고    scopus 로고
    • Preventing neuronal damage and inflammation in vivo during cortical microelectrode implantation through the use of Poloxamer P-188
    • A. Misra, P. Kondaveeti, J. Nissanov, K. Barbee, P. Shewokis, L. Rioux, and K.A. Moxon Preventing neuronal damage and inflammation in vivo during cortical microelectrode implantation through the use of Poloxamer P-188 Journal of Neural Engineering 10 2013 016011
    • (2013) Journal of Neural Engineering , vol.10 , pp. 016011
    • Misra, A.1    Kondaveeti, P.2    Nissanov, J.3    Barbee, K.4    Shewokis, P.5    Rioux, L.6    Moxon, K.A.7
  • 13
    • 34247331898 scopus 로고    scopus 로고
    • Dexamethasone-coated neural probes elicit attenuated inflammatory response and neuronal loss compared to uncoated neural probes
    • Y. Zhong, and R.V. Bellamkonda Dexamethasone-coated neural probes elicit attenuated inflammatory response and neuronal loss compared to uncoated neural probes Brain Research 1148 2007 15 27
    • (2007) Brain Research , vol.1148 , pp. 15-27
    • Zhong, Y.1    Bellamkonda, R.V.2
  • 14
    • 32144463825 scopus 로고    scopus 로고
    • Sustained release of dexamethasone from hydrophilic matrices using PLGA nanoparticles for neural drug delivery
    • D.H. Kim, and D.C. Martin Sustained release of dexamethasone from hydrophilic matrices using PLGA nanoparticles for neural drug delivery Biomaterials 27 2006 3031 3037
    • (2006) Biomaterials , vol.27 , pp. 3031-3037
    • Kim, D.H.1    Martin, D.C.2
  • 15
    • 79959547261 scopus 로고    scopus 로고
    • A comparative study of apatite coating and apatite/collagen composite coating fabricated on NiTi shape memory alloy through electrochemical deposition
    • T. Sun, W.C. Lee, and M. Wang A comparative study of apatite coating and apatite/collagen composite coating fabricated on NiTi shape memory alloy through electrochemical deposition Materials Letters 65 2011 2575 2577
    • (2011) Materials Letters , vol.65 , pp. 2575-2577
    • Sun, T.1    Lee, W.C.2    Wang, M.3
  • 16
    • 84873725654 scopus 로고    scopus 로고
    • Effect of solution aging time on stability of colorimetric assay for degradation rate evaluation of porous Si in artificial cerebrospinal fluid
    • T. Sun, J.Z. An, W.T. Park, and M. Je Effect of solution aging time on stability of colorimetric assay for degradation rate evaluation of porous Si in artificial cerebrospinal fluid Advanced Materials Research 651 2013 306 311
    • (2013) Advanced Materials Research , vol.651 , pp. 306-311
    • Sun, T.1    An, J.Z.2    Park, W.T.3    Je, M.4
  • 17
    • 84875372170 scopus 로고    scopus 로고
    • Engineering porous silicon nanostructures as tunable carriers for mitoxantrone dihydrochloride
    • A. Tzur-Balter, A. Gilert, N. Massad-Ivanir, and E. Segal Engineering porous silicon nanostructures as tunable carriers for mitoxantrone dihydrochloride Acta Biomaterialia 9 2013 6208 6217
    • (2013) Acta Biomaterialia , vol.9 , pp. 6208-6217
    • Tzur-Balter, A.1    Gilert, A.2    Massad-Ivanir, N.3    Segal, E.4
  • 19
  • 20
    • 84879687090 scopus 로고    scopus 로고
    • Silica nanoparticle-based films on titanium substrates with long-term superhydrophilic and superhydrophobic stability
    • R.A. Fleming, and M. Zou Silica nanoparticle-based films on titanium substrates with long-term superhydrophilic and superhydrophobic stability Applied Surface Science 280 2013 820 827
    • (2013) Applied Surface Science , vol.280 , pp. 820-827
    • Fleming, R.A.1    Zou, M.2
  • 21
    • 78651074480 scopus 로고    scopus 로고
    • (Ti, O)/Ti and (Ti, O, N)/Ti composite coatings fabricated via PIIID for the medical application of NiTi shape memory alloy
    • T. Sun, L. Wang, and M. Wang (Ti, O)/Ti and (Ti, O, N)/Ti composite coatings fabricated via PIIID for the medical application of NiTi shape memory alloy Journal of Biomedical Materials Research Part B: Applied Biomaterials 968 2011 249 260
    • (2011) Journal of Biomedical Materials Research Part B: Applied Biomaterials , vol.968 , pp. 249-260
    • Sun, T.1    Wang, L.2    Wang, M.3
  • 24
    • 78650979671 scopus 로고    scopus 로고
    • Real-time monitoring of sustained drug release using the optical properties of porous silicon photonic crystal particles
    • E.C. Wu, J.S. Andrew, L. Cheng, W.R. Freeman, L. Pearson, and M.J. Sailor Real-time monitoring of sustained drug release using the optical properties of porous silicon photonic crystal particles Biomaterials 32 2011 1957 1966
    • (2011) Biomaterials , vol.32 , pp. 1957-1966
    • Wu, E.C.1    Andrew, J.S.2    Cheng, L.3    Freeman, W.R.4    Pearson, L.5    Sailor, M.J.6
  • 25
    • 79960556002 scopus 로고    scopus 로고
    • Immune responses to implants - A review of the implications for the design of immunomodulatory biomaterials
    • S. Franz, S. Rammelt, D. Scharnweber, and J.C. Simon Immune responses to implants - a review of the implications for the design of immunomodulatory biomaterials Biomaterials 32 2011 6692 6709
    • (2011) Biomaterials , vol.32 , pp. 6692-6709
    • Franz, S.1    Rammelt, S.2    Scharnweber, D.3    Simon, J.C.4
  • 26
    • 77249090658 scopus 로고    scopus 로고
    • Poly(lactide-co-glycolide) nanoparticle assembly for highly efficient delivery of potent therapeutic agents from medical devices
    • C.T. Lo, P.R. Van Tassel, and W.M. Saltzman Poly(lactide-co-glycolide) nanoparticle assembly for highly efficient delivery of potent therapeutic agents from medical devices Biomaterials 31 2010 3631 3642
    • (2010) Biomaterials , vol.31 , pp. 3631-3642
    • Lo, C.T.1    Van Tassel, P.R.2    Saltzman, W.M.3
  • 27
    • 18744384648 scopus 로고    scopus 로고
    • Parylene flexible neural probes integrated with microfluidic channels
    • S. Takeuchi, D. Ziegler, Y. Yoshida, K. Mabuchi, and T. Suzuki Parylene flexible neural probes integrated with microfluidic channels Lab on a Chip 5 2005 519 523
    • (2005) Lab on A Chip , vol.5 , pp. 519-523
    • Takeuchi, S.1    Ziegler, D.2    Yoshida, Y.3    Mabuchi, K.4    Suzuki, T.5
  • 28
    • 84954358659 scopus 로고    scopus 로고
    • Expression of bystin in reactive astrocytes induced by ischemia/reperfusion and chemical hypoxia in vitro
    • F. Du, Li Zhu, Z. Qian, X.M. Wu, W.H. Yung, W.Y. Xu, and Y. Ke Expression of bystin in reactive astrocytes induced by ischemia/reperfusion and chemical hypoxia in vitro Biochimica et Biophysica Acta 1782 2008 658 663
    • (2008) Biochimica et Biophysica Acta , vol.1782 , pp. 658-663
    • Du, F.1    Zhu, L.2    Qian, Z.3    Wu, X.M.4    Yung, W.H.5    Xu, W.Y.6    Ke, Y.7
  • 30
    • 2442719087 scopus 로고    scopus 로고
    • Nanostructured surface modification of ceramic-based microelectrodes to enhance biocompatibility for a direct brain-machine interface
    • K.A. Moxon, N.M. Kalkhoran, M. Markert, and M.A. Sambito Nanostructured surface modification of ceramic-based microelectrodes to enhance biocompatibility for a direct brain-machine interface IEEE Transactions on Biomedical Engineering 51 2004 881 889
    • (2004) IEEE Transactions on Biomedical Engineering , vol.51 , pp. 881-889
    • Moxon, K.A.1    Kalkhoran, N.M.2    Markert, M.3    Sambito, M.A.4
  • 31
    • 34547175689 scopus 로고    scopus 로고
    • Influence of experimental parameters on physical properties of porous silicon and oxidized porous silicon layers
    • J. Charrier, V. Alaiwan, P. Pirasteh, A. Najar, and M. Gadonna Influence of experimental parameters on physical properties of porous silicon and oxidized porous silicon layers Applied Surface Science 253 2007 8632 8636
    • (2007) Applied Surface Science , vol.253 , pp. 8632-8636
    • Charrier, J.1    Alaiwan, V.2    Pirasteh, P.3    Najar, A.4    Gadonna, M.5
  • 32
    • 79954618009 scopus 로고    scopus 로고
    • Effect of oligoethylene glycol moieties in porous silicon surface functionalisation on protein adsorption and cell attachment
    • M.J. Sweetman, F.J. Harding, S.D. Graney, and N.H. Voelcker Effect of oligoethylene glycol moieties in porous silicon surface functionalisation on protein adsorption and cell attachment Applied Surface Science 257 2011 6768 6774
    • (2011) Applied Surface Science , vol.257 , pp. 6768-6774
    • Sweetman, M.J.1    Harding, F.J.2    Graney, S.D.3    Voelcker, N.H.4
  • 33
    • 33646857934 scopus 로고    scopus 로고
    • Evaluation of mammalian cell adhesion on surface-modified porous silicon
    • S.P. Low, K.A. Williams, L.T. Canham, and N.H. Voelcker Evaluation of mammalian cell adhesion on surface-modified porous silicon Biomaterials 27 2006 4538 4546
    • (2006) Biomaterials , vol.27 , pp. 4538-4546
    • Low, S.P.1    Williams, K.A.2    Canham, L.T.3    Voelcker, N.H.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.