메뉴 건너뛰기




Volumn 166, Issue 3, 2013, Pages 681-687

Long-term hemodynamic performance of bileaflet prostheses versus tilting-disc prostheses in the aortic position

Author keywords

Aortic valve replacement; Hemodynamics; Prosthetic heart valve

Indexed keywords

ADULT; AGE; AGED; AORTA STENOSIS; AORTA VALVE DISEASE; AORTA VALVE PROSTHESIS; AORTA VALVE REPLACEMENT; AORTIC VALVE PANNUS FORMATION; ARTICLE; ATS MEDICAL OPENPIVOT BILEAFLET PROSTHESIS; BLEEDING; BRAIN HEMORRHAGE; BRAIN INFARCTION; COMPARATIVE STUDY; CONTROLLED STUDY; ECHOCARDIOGRAPHY; ENDOCARDITIS; FEMALE; FOLLOW UP; GENDER; HEART LEFT VENTRICLE; HEMODYNAMICS; HUMAN; INCIDENCE; LEFT VENTRICULAR MASS INDEX; MAJOR CLINICAL STUDY; MALE; MEDTRONIC HALL TILTING DISC VALVE PROSTHESIS; MITRAL VALVE REPLACEMENT; OVERALL SURVIVAL; PNEUMONIA; PRESSURE GRADIENT; PRIORITY JOURNAL; PROSTHESIS FAILURE; PROSTHETIC VALVE ENDOCARDITIS; REOPERATION; SEPTIC SHOCK; SUDDEN DEATH; SURGICAL MORTALITY; SURVIVAL; SURVIVAL RATE; THROMBOEMBOLISM; TRANSAORTIC MEAN PRESSURE GRADIENT; TRICUSPID VALVE REGURGITATION; VALVULAR HEART DISEASE; AORTA VALVE; HEART VALVE PROSTHESIS; HEART VALVE REPLACEMENT; METHODOLOGY; MIDDLE AGED; PATHOLOGY; PHYSIOLOGY; RETROSPECTIVE STUDY; TIME; PROCEDURES; SURGERY; TRENDS;

EID: 84893446887     PISSN: 01675273     EISSN: 18741754     Source Type: Journal    
DOI: 10.1016/j.ijcard.2011.11.105     Document Type: Article
Times cited : (8)

References (21)
  • 1
    • 0018326932 scopus 로고
    • An improved pivotal disc-type prosthetic heart valve
    • Hall KV, Kaster RL, Woien A. An improved pivotal disc-type prosthetic heart valve. J Oslo City Hosp 1979; 29: 3-21.
    • (1979) J Oslo City Hosp , vol.29 , pp. 3-21
    • Hall, K.V.1    Kaster, R.L.2    Woien, A.3
  • 2
    • 0020638644 scopus 로고
    • Clinical and echocardiographic assessment of the medtronic-hall valve: Experience with 370 implanted valves
    • (Spec 2)
    • Butchart EG, Griffiths BE, Breckenridge IM. Clinical and echocardiographic assessment of the Medtronic-Hall valve: experience with 370 implanted valves. Thorac Cardiovasc Surg 1983; 31(Spec 2): 81-4.
    • (1983) Thorac Cardiovasc Surg , vol.31 , pp. 81-84
    • Butchart, E.G.1    Griffiths, B.E.2    Breckenridge, I.M.3
  • 3
    • 0034045201 scopus 로고    scopus 로고
    • ATS prosthetic valve motion: An in vitro analysis
    • Tayama E, Feng Z, Oda T, et al. ATS prosthetic valve motion: an in vitro analysis. J Heart Valve Dis 2000; 9: 408-14.
    • (2000) J Heart Valve Dis , vol.9 , pp. 408-414
    • Tayama, E.1    Feng, Z.2    Oda, T.3
  • 4
    • 13844317359 scopus 로고    scopus 로고
    • Comparison of transprosthetic mean pressure gradients between medtronic hall and ATS valves in the aortic position
    • Sung K, Park PW, Park KH, Jun TG, Lee YT, Yang JH. Comparison of transprosthetic mean pressure gradients between Medtronic Hall and ATS valves in the aortic position. Int J Cardiol 2005; 99: 29-35.
    • (2005) Int J Cardiol , vol.99 , pp. 29-35
    • Sung, K.1    Park, P.W.2    Park, K.H.3    Jun, T.G.4    Lee, Y.T.5    Yang, J.H.6
  • 5
    • 40749143101 scopus 로고    scopus 로고
    • Guidelines for reporting mortality and morbidity after cardiac valve interventions
    • Akins CW, Miller DC, Turina MI, et al. Guidelines for reporting mortality and morbidity after cardiac valve interventions. Ann Thorac Surg 2008; 85: 1490-5.
    • (2008) Ann Thorac Surg , vol.85 , pp. 1490-1495
    • Akins, C.W.1    Miller, D.C.2    Turina, M.I.3
  • 6
    • 29244432482 scopus 로고    scopus 로고
    • Recommendations for chamber quantification: A report from the American society of echocardiography's guidelines and standards committee and the chamber quantification writing group, developed in conjunction with the european association of echocardiography, a branch of the european society of cardiology
    • Lang RM, Bierig M, Devereux RB, et al. Recommendations for chamber quantification: a report from the American Society of Echocardiography's Guidelines and Standards Committee and the Chamber Quantification Writing Group, developed in conjunction with the European Association of Echocardiography, a branch of the European Society of Cardiology. J Am Soc Echocardiogr 2005; 18: 1440-63.
    • (2005) J Am Soc Echocardiogr , vol.18 , pp. 1440-1463
    • Lang, R.M.1    Bierig, M.2    Devereux, R.B.3
  • 7
    • 0017331788 scopus 로고
    • Echocardiographic determination of left ventricular mass in man: Anatomic validation of the method
    • Devereux RD, Reichek N. Echocardiographic determination of left ventricular mass in man: anatomic validation of the method. Circulation 1977; 55: 613-8.
    • (1977) Circulation , vol.55 , pp. 613-618
    • Devereux, R.D.1    Reichek, N.2
  • 8
    • 0034077342 scopus 로고    scopus 로고
    • Tilting disc versus bileaflet aortic valve substitutes: Intraoperative and postoperative hemodynamic performance in humans
    • discussion 311-2
    • Kleine P, Hasenkam MJ, Nygaard H, Perthel M, Wesemeyer D, Laas J. Tilting disc versus bileaflet aortic valve substitutes: intraoperative and postoperative hemodynamic performance in humans. J Heart Valve Dis 2000; 9: 308-11discussion 311-2
    • (2000) J Heart Valve Dis , vol.9 , pp. 308-311
    • Kleine, P.1    Hasenkam, M.J.2    Nygaard, H.3    Perthel, M.4    Wesemeyer, D.5    Laas, J.6
  • 9
    • 4944257847 scopus 로고    scopus 로고
    • Tilting-disc versus bileaflet mechanical prostheses in the aortic position: A multicenter evaluation
    • Vitale N, De Feo M, De Siena P, et al. Tilting-disc versus bileaflet mechanical prostheses in the aortic position: a multicenter evaluation. J Heart Valve Dis 2004; 13(Suppl. 1):S27-34.
    • (2004) J Heart Valve Dis , vol.13 , Issue.SUPPL. 1
    • Vitale, N.1    De Feo, M.2    De Siena, P.3
  • 10
    • 78751675982 scopus 로고    scopus 로고
    • Serial changes of hemodynamic performance with medtronic hall valve in aortic position
    • Cho YH, Jeong DS, Park PW, et al. Serial changes of hemodynamic performance with Medtronic Hall valve in aortic position. Ann Thorac Surg 2011; 91: 424-31.
    • (2011) Ann Thorac Surg , vol.91 , pp. 424-431
    • Cho, Y.H.1    Jeong, D.S.2    Park, P.W.3
  • 11
    • 50649110229 scopus 로고    scopus 로고
    • Predictors of secondary tricuspid regurgitation after left-sided valve replacement
    • Wang G, Sun Z, Xia J, et al. Predictors of secondary tricuspid regurgitation after left-sided valve replacement. Surg Today 2008; 38: 778-83.
    • (2008) Surg Today , vol.38 , pp. 778-783
    • Wang, G.1    Sun, Z.2    Xia, J.3
  • 13
    • 59649116115 scopus 로고    scopus 로고
    • Nine-year routine clinical experience of aortic valve replacement with ATS mechanical valves
    • Villemot JP, Lekehal M, Maureira P, et al. Nine-year routine clinical experience of aortic valve replacement with ATS mechanical valves. J Heart Valve Dis 2008; 17: 648-56.
    • (2008) J Heart Valve Dis , vol.17 , pp. 648-656
    • Villemot, J.P.1    Lekehal, M.2    Maureira, P.3
  • 14
    • 37349016908 scopus 로고    scopus 로고
    • Twenty-five-year experience with the medtronic-hall valve prosthesis in the aortic position: A follow-up cohort study of 816 consecutive patients
    • Svennevig JL, Abdelnoor M, Nitter-Hauge S. Twenty-five-year experience with the Medtronic-Hall valve prosthesis in the aortic position: a follow-up cohort study of 816 consecutive patients. Circulation 2007; 116: 1795-800.
    • (2007) Circulation , vol.116 , pp. 1795-1800
    • Svennevig, J.L.1    Abdelnoor, M.2    Nitter-Hauge, S.3
  • 17
    • 77952323234 scopus 로고    scopus 로고
    • Fifteen years of experience with ATS mechanical heart valve prostheses
    • Sezai A, Hata M, Niino T, et al. Fifteen years of experience with ATS mechanical heart valve prostheses. J Thorac Cardiovasc Surg 2010; 139: 1494-500.
    • (2010) J Thorac Cardiovasc Surg , vol.139 , pp. 1494-1500
    • Sezai, A.1    Hata, M.2    Niino, T.3
  • 18
    • 33748995076 scopus 로고    scopus 로고
    • Prevalence of pannus formation after aortic valve replacement: Clinical aspects and surgical treatment
    • Sakamoto Y, Hashimoto K, Okuyama H, Ishii S, Shingo T, Kagawa H. Prevalence of pannus formation after aortic valve replacement: clinical aspects and surgical treatment. J Artif Organs 2006; 9: 199-202.
    • (2006) J Artif Organs , vol.9 , pp. 199-202
    • Sakamoto, Y.1    Hashimoto, K.2    Okuyama, H.3    Ishii, S.4    Shingo, T.5    Kagawa, H.6
  • 20
    • 0032794497 scopus 로고    scopus 로고
    • Reoperations for acute prosthetic thrombosis and pannus: An assessment of rates, relationship and risk
    • Rizzoli G, Guglielmi C, Toscano G, et al. Reoperations for acute prosthetic thrombosis and pannus: an assessment of rates, relationship and risk. Eur J Cardiothorac Surg 1999; 16: 74-80.
    • (1999) Eur J Cardiothorac Surg , vol.16 , pp. 74-80
    • Rizzoli, G.1    Guglielmi, C.2    Toscano, G.3
  • 21
    • 58749088412 scopus 로고    scopus 로고
    • Medtronic hall valve malfunction due to pannus formation in the aortic position with peculiar movement of the leaflet: A case report
    • Horiguchi M, Seko T, Yazu T, Takeuchi M, Ichikawa T. Medtronic Hall valve malfunction due to pannus formation in the aortic position with peculiar movement of the leaflet: a case report. J Heart Valve Dis 2008; 17: 583-5.
    • (2008) J Heart Valve Dis , vol.17 , pp. 583-585
    • Horiguchi, M.1    Seko, T.2    Yazu, T.3    Takeuchi, M.4    Ichikawa, T.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.