메뉴 건너뛰기




Volumn 34, Issue 12, 2013, Pages

A readout system for passive pressure sensors

Author keywords

inductive coupling; LC resonant circuit; passive pressure sensor; resonant frequency; wireless

Indexed keywords

INDUCTIVE COUPLINGS; INDUCTIVELY-COUPLED; LC RESONANT CIRCUITS; LOW-TEMPERATURE CO-FIRED CERAMICS; MEASUREMENT CIRCUIT; PASSIVE PRESSURE SENSORS; PRESSURE VARIATIONS; RESONANT FREQUENCY SHIFT;

EID: 84891600666     PISSN: 16744926     EISSN: None     Source Type: Journal    
DOI: 10.1088/1674-4926/34/12/125006     Document Type: Article
Times cited : (7)

References (18)
  • 1
    • 0027612054 scopus 로고
    • Advances in sensors for aerospace applications
    • 10.1016/0924-4247(93)80024-B 0924-4247
    • Prosser S J 1993 Advances in sensors for aerospace applications Sensors and Actuators A: Physical 37/38 128
    • (1993) Sensors and Actuators A: Physical , vol.37-38 , pp. 128
    • Prosser, S.J.1
  • 2
    • 14644392839 scopus 로고    scopus 로고
    • The changing automotive environment: High-temperature electronics
    • 10.1109/TEPM.2004.843109 1521-334X
    • Johnson R W, Evans J L, Jacobsen P, et al 2004 The changing automotive environment: high-temperature electronics IEEE Trans Electron Packag Manuf 27 (3) 164
    • (2004) IEEE Trans Electron Packag Manuf , vol.27 , Issue.3 , pp. 164
    • Johnson, R.W.1    Evans, J.L.2    Jacobsen, P.3
  • 3
    • 0033704280 scopus 로고    scopus 로고
    • Electrode-posited copper inductors for intraocular pressure telemetry
    • Puers R, Vandevoorde G, Bruyke R D D, et al 2002 Electrode-posited copper inductors for intraocular pressure telemetry J Micromechan Microeng 10 (2) 124
    • (2002) J Micromechan Microeng , vol.10 , Issue.2 , pp. 124
    • Puers, R.1    Vandevoorde, G.2    Bruyke, R.D.D.3
  • 4
    • 57449102575 scopus 로고    scopus 로고
    • Microfabricated implantable parylene-based wireless passive intraocular pressure sensors
    • 10.1109/JMEMS.2008.2004945 1057-7157
    • Chen P J, Rodger D C, Saati S, et al 2008 Microfabricated implantable parylene-based wireless passive intraocular pressure sensors J Micro-Electromechan Syst 17 (6) 1342
    • (2008) J Micro-Electromechan Syst , vol.17 , Issue.6 , pp. 1342
    • Chen, P.J.1    Rodger, D.C.2    Saati, S.3
  • 5
    • 33744513520 scopus 로고    scopus 로고
    • A new passive telemetry LC pressure and temperature sensor optimized for TPMS
    • 1742-6596 127
    • Nabipoor M, Majlis B Y 2006 A new passive telemetry LC pressure and temperature sensor optimized for TPMS J Phys: Conference Series 34 770
    • (2006) J Phys: Conference Series , vol.34 , Issue.1 , pp. 770
    • Nabipoor, M.1    Majlis, B.Y.2
  • 6
    • 84891618484 scopus 로고    scopus 로고
    • Polymer/ceramic wireless MEMS pressure sensors for harsh environments: High temperature and biomedical applications
    • Fonseca M A 2007 Polymer/ceramic wireless MEMS pressure sensors for harsh environments: high temperature and biomedical applications School of Electrical and Computer Engineering
    • (2007) School of Electrical and Computer Engineering
    • Fonseca, M.A.1
  • 7
    • 0036686314 scopus 로고    scopus 로고
    • Wireless micromachined ceramic pressure sensor for high-temperature applications
    • 10.1109/JMEMS.2002.800939 1057-7157
    • Fonseca M A, English J M, Arx M V, et al 2002 Wireless micromachined ceramic pressure sensor for high-temperature applications J Microelectromechan Syst 11 (4) 337
    • (2002) J Microelectromechan Syst , vol.11 , Issue.4 , pp. 337
    • Fonseca, M.A.1    English, J.M.2    Arx, M.V.3
  • 10
    • 0000298124 scopus 로고    scopus 로고
    • Hermetically sealed inductor - Capacitor (LC) resonator for remote pressure monitoring
    • 10.1143/JJAP.37.7124 0021-4922
    • Park E C, Yoon E, Yoon J B 1998 Hermetically sealed inductor - capacitor (LC) resonator for remote pressure monitoring Jpn J Appl Phys 37 (12B) 7124
    • (1998) Jpn J Appl Phys , vol.37 , Issue.12 B , pp. 7124
    • Park, E.C.1    Yoon, E.2    Yoon, J.B.3
  • 11
    • 1642566500 scopus 로고    scopus 로고
    • A readout circuit for an intraocular pressure sensor
    • 10.1016/j.sna.2003.09.015 0924-4247 A
    • Coosemans J, Catrysse M, Puers R 2004 A readout circuit for an intraocular pressure sensor Sensors and Actuators A 110 (1-3) 432
    • (2004) Sensors and Actuators , vol.110 , Issue.1-3 , pp. 432
    • Coosemans, J.1    Catrysse, M.2    Puers, R.3
  • 12
    • 1642566578 scopus 로고    scopus 로고
    • Micro devices for a cere-brospinal fluid (CSF) shunt system
    • 10.1016/j.sna.2003.10.047 0924-4247 A
    • Yoon H J, Jung J M, Jeong J S, et al 2004 Micro devices for a cere-brospinal fluid (CSF) shunt system Sensors and Actuators A 110 (1-3) 68
    • (2004) Sensors and Actuators , vol.110 , Issue.1-3 , pp. 68
    • Yoon, H.J.1    Jung, J.M.2    Jeong, J.S.3
  • 13
    • 0036143086 scopus 로고    scopus 로고
    • A passive wireless integrated humidity sensor
    • 10.1016/S0924-4247(01)00720-8 0924-4247 A
    • Harpster T J, Stark B, Najafi K 2002 A passive wireless integrated humidity sensor Sensors and Actuators A 95 (2/3) 100
    • (2002) Sensors and Actuators , vol.95 , Issue.2-3 , pp. 100
    • Harpster, T.J.1    Stark, B.2    Najafi, K.3
  • 14
    • 84877831888 scopus 로고    scopus 로고
    • Measurement of wireless pressure sensors fabricated in high temperature co-fired ceramic MEMS technology
    • 10.1631/jzus.C12MNT04 1869-1951 C
    • Xiong J J, Zheng S J, Hong Y P, et al 2013 Measurement of wireless pressure sensors fabricated in high temperature co-fired ceramic MEMS technology Journal of Zhejiang University Science C 14 (4) 258
    • (2013) Journal of Zhejiang University Science , vol.14 , Issue.4 , pp. 258
    • Xiong, J.J.1    Zheng, S.J.2    Hong, Y.P.3
  • 15
    • 0343081380 scopus 로고    scopus 로고
    • Simple accurate expressions for planar spiral inductances
    • 10.1109/4.792620 0018-9200
    • Mohan S S, Del Mar Hershenson M, Boyd S P, et al 1999 Simple accurate expressions for planar spiral inductances IEEE J Solid-state Circuits 34 (10) 1419
    • (1999) IEEE J Solid-state Circuits , vol.34 , Issue.10 , pp. 1419
    • Mohan, S.S.1    Del Mar Hershenson, M.2    Boyd, S.P.3
  • 16
    • 84877285297 scopus 로고    scopus 로고
    • Wireless LTCC-based capacitive pressure sensor for harsh environment
    • 10.1016/j.sna.2013.04.007 0924-4247
    • Xiong J J, Li Y, Hong Y P, et al 2013 Wireless LTCC-based capacitive pressure sensor for harsh environment Sensors and Actuators A: Physical 197 30
    • (2013) Sensors and Actuators A: Physical , vol.197 , pp. 30
    • Xiong, J.J.1    Li, Y.2    Hong, Y.P.3
  • 17
    • 58149185308 scopus 로고    scopus 로고
    • A passive wireless temperature sensor for harsh environment applications
    • 10.3390/s8127982 1424-8220
    • Wang Y, Jia Y, Chen Q S, et al 2008 A passive wireless temperature sensor for harsh environment applications Sensors 8 (12) 7982
    • (2008) Sensors , vol.8 , Issue.12 , pp. 7982
    • Wang, Y.1    Jia, Y.2    Chen, Q.S.3
  • 18
    • 17444371362 scopus 로고    scopus 로고
    • Qiu G Y 1999 Circuit Beijing: Higher Education Press
    • (1999) Circuit
    • Qiu, G.Y.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.