Volumn 110, Issue 1-3, 2004, Pages 432-438

A readout circuit for an intra-ocular pressure sensor

Author keywords

Intra ocular pressure; Micro coils; Passive telemetry; Readout circuit

Indexed keywords

ELECTRIC COILS; NETWORKS (CIRCUITS); PATIENT MONITORING; PRESSURE TRANSDUCERS; READOUT SYSTEMS; TELEMETERING; VARIABLE FREQUENCY OSCILLATORS;

EID: 1642566500     PISSN: 09244247     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.sna.2003.09.015     Document Type: Conference Paper
Times cited : (60)

References (16)
  • 4
    • 0014080792 scopus 로고
    • Miniature pressure transensor for implanting in the eye
    • Collins C.C. Miniature pressure transensor for implanting in the eye. IEEE Trans. Biomed. Eng. BME-14:1967;74-83.
    • (1967) IEEE Trans. Biomed. Eng. , vol.BME-14 , pp. 74-83
    • Collins, C.C.1
  • 5
    • 0025698114 scopus 로고
    • Passive silicon transensor intended for biomedical, remote pressure monitoring
    • Backlund Y., Rosengren L., Hok B., Svedbergh B. Passive silicon transensor intended for biomedical, remote pressure monitoring. Sens. Actuators A. 21:1990;58-61.
    • (1990) Sens. Actuators A , vol.21 , pp. 58-61
    • Backlund, Y.1    Rosengren, L.2    Hok, B.3    Svedbergh, B.4
  • 6
    • 0035892868 scopus 로고    scopus 로고
    • A wireless batch sealed absolute capacitive pressure sensor
    • Akar O., Akin T., Najafi K. A wireless batch sealed absolute capacitive pressure sensor. Sens. Actuators A. 95:2001;29-38.
    • (2001) Sens. Actuators A , vol.95 , pp. 29-38
    • Akar, O.1    Akin, T.2    Najafi, K.3
  • 7
    • 0000298124 scopus 로고    scopus 로고
    • Hermetically sealed inductor-capacitor (LC) resonator for remote pressure monitoring
    • Park E., Yoon J., Yoon E. Hermetically sealed inductor-capacitor (LC) resonator for remote pressure monitoring. Jpn. J. Appl. Phys. 37:1998;7124-7128.
    • (1998) Jpn. J. Appl. Phys. , vol.37 , pp. 7124-7128
    • Park, E.1    Yoon, J.2    Yoon, E.3
  • 10
    • 0033704280 scopus 로고    scopus 로고
    • Electrodeposited copper inductors for intraocular pressure telemetry
    • Puers R., Vandevoorde G., De Bruyker D. Electrodeposited copper inductors for intraocular pressure telemetry. J. Micromech. Microeng. 10:2000;124-129.
    • (2000) J. Micromech. Microeng. , vol.10 , pp. 124-129
    • Puers, R.1    Vandevoorde, G.2    De Bruyker, D.3
  • 11
    • 0030200060 scopus 로고    scopus 로고
    • Geometric approach for coupling enhancement of magnetically coupled coils
    • Zierhofer C.M., Hochmair E.S. Geometric approach for coupling enhancement of magnetically coupled coils. IEEE Trans. Biomed. Eng. BME-43:1996;708-714.
    • (1996) IEEE Trans. Biomed. Eng. , vol.BME-43 , pp. 708-714
    • Zierhofer, C.M.1    Hochmair, E.S.2
  • 12
    • 0023324937 scopus 로고
    • Radio-frequency coils in implantable devices: Misalignment analysis and design procedure
    • Soma M., Galbraith D.C., White R.L. Radio-frequency coils in implantable devices: misalignment analysis and design procedure. IEEE Trans. Biomed. Eng. BME-34:1987;276-282.
    • (1987) IEEE Trans. Biomed. Eng. , vol.BME-34 , pp. 276-282
    • Soma, M.1    Galbraith, D.C.2    White, R.L.3
  • 13
    • 0028498583 scopus 로고
    • FASTHENRY: A multipole-accelerated 3-D inductance extraction program
    • Kamon M., Tsuk M.J., White J. FASTHENRY: A multipole-accelerated 3-D inductance extraction program. IEEE Trans. Microwave Theory Tech. MTT-42:1994;1750-1758.
    • (1994) IEEE Trans. Microwave Theory Tech. , vol.MTT-42 , pp. 1750-1758
    • Kamon, M.1    Tsuk, M.J.2    White, J.3
  • 14
    • 0025698073 scopus 로고
    • A capacitive pressure sensor with low impedance output and active suppression of parasitic effects
    • Puers B., Peeters E., Van Den Bossche A., Sansen W. A capacitive pressure sensor with low impedance output and active suppression of parasitic effects. Sens. Actuators. A21-A23:1990;104-108.
    • (1990) Sens. Actuators , vol.A21-A23 , pp. 104-108
    • Puers, B.1    Peeters, E.2    Van Den Bossche, A.3    Sansen, W.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.