메뉴 건너뛰기




Volumn 35, Issue 2, 2014, Pages 113-122

Management of respiratory motion in PET/computed tomography: The state of the art

Author keywords

compensation; correction; PET computed tomography; respiratory motion; tracking

Indexed keywords

FLUORODEOXYGLUCOSE F 18;

EID: 84891541970     PISSN: 01433636     EISSN: 14735628     Source Type: Journal    
DOI: 10.1097/MNM.0000000000000048     Document Type: Review
Times cited : (103)

References (85)
  • 1
    • 13944279944 scopus 로고    scopus 로고
    • Monitoring response to treatment in patients utilizing PET
    • Avril NE, Weber WA. Monitoring response to treatment in patients utilizing PET. Radiol Clin North Am 2005; 43:189-204.
    • (2005) Radiol Clin North Am , vol.43 , pp. 189-204
    • Avril, N.E.1    Weber, W.A.2
  • 3
    • 84891538420 scopus 로고    scopus 로고
    • Assessment of response to therapy
    • Peller P, Subramaniam R, Guermazi A, editors, Berlin: Springer-Verlag
    • Gholamrezanezhad A, Chirindel A, Subramaniam R. Assessment of response to therapy. In: Peller P, Subramaniam R, Guermazi A, editors. PET-CT and PET-MRI in oncology. Berlin: Springer-Verlag; 2012. pp. 279-317.
    • (2012) PET-CT and PET-MRI in Oncology , pp. 279-317
    • Gholamrezanezhad, A.1    Chirindel, A.2    Subramaniam, R.3
  • 4
    • 0037792992 scopus 로고    scopus 로고
    • Staging of non-small-cell lung cancer with integrated positron-emission tomography and computed tomography
    • Lardinois D, Weder W, Hany TF, Kamel EM, Korom S, Seifert B, et al. Staging of non-small-cell lung cancer with integrated positron-emission tomography and computed tomography. N Engl J Med 2003; 348: 2500-2507.
    • (2003) N Engl J Med , vol.348 , pp. 2500-2507
    • Lardinois, D.1    Weder, W.2    Hany, T.F.3    Kamel, E.M.4    Korom, S.5    Seifert, B.6
  • 5
    • 10044237741 scopus 로고    scopus 로고
    • Does the novel PET/CT imaging modality impact on the treatment of patients with metastatic colorectal cancer of the liver?
    • Selzner M, Hany TF, Wildbrett P, McCormack L, Kadry Z, Clavien P-A. Does the novel PET/CT imaging modality impact on the treatment of patients with metastatic colorectal cancer of the liver? Ann Surg 2004; 240:1027-1036.
    • (2004) Ann Surg , vol.240 , pp. 1027-1036
    • Selzner, M.1    Hany, T.F.2    Wildbrett, P.3    McCormack, L.4    Kadry, Z.5    Clavien, P.-A.6
  • 6
    • 77049180654 scopus 로고
    • Movements of the thoracic cage and diaphragm in respiration
    • Wade OL. Movements of the thoracic cage and diaphragm in respiration. J Physiol 1954; 124:193-212.
    • (1954) J Physiol , vol.124 , pp. 193-212
    • Wade, O.L.1
  • 7
    • 0015418117 scopus 로고
    • Assessment of hepatic respiratory excursion
    • Weiss PH, Baker JM, Potchen EJ. Assessment of hepatic respiratory excursion. J Nucl Med 1972; 13:758-759.
    • (1972) J Nucl Med , vol.13 , pp. 758-759
    • Weiss, P.H.1    Baker, J.M.2    Potchen, E.J.3
  • 8
  • 9
    • 46149139183 scopus 로고
    • Structural model of thorax and abdomen for respiratory mechanics
    • Loring SH. Structural model of thorax and abdomen for respiratory mechanics. Math Model 1986; 7:1083-1098.
    • (1986) Math Model , vol.7 , pp. 1083-1098
    • Loring, S.H.1
  • 10
    • 0023574785 scopus 로고
    • Regional ventilation during spontaneous breathing and mechanical ventilation in dogs
    • Hubmayr RD, Rodarte JR, Walters BJ, Tonelli FM. Regional ventilation during spontaneous breathing and mechanical ventilation in dogs. J Appl Physiol 1987; 63:2467-2475.
    • (1987) J Appl Physiol , vol.63 , pp. 2467-2475
    • Hubmayr, R.D.1    Rodarte, J.R.2    Walters, B.J.3    Tonelli, F.M.4
  • 11
    • 0037884881 scopus 로고    scopus 로고
    • Respiratory motion artifacts on PET emission images obtained using CT attenuation correction on PET-CT
    • Osman MM, Cohade C, Nakamoto Y, Wahl RL. Respiratory motion artifacts on PET emission images obtained using CT attenuation correction on PET-CT. Eur J Nucl Med Mol Imaging 2003; 30:603-606.
    • (2003) Eur J Nucl Med Mol Imaging , vol.30 , pp. 603-606
    • Osman, M.M.1    Cohade, C.2    Nakamoto, Y.3    Wahl, R.L.4
  • 12
    • 79958809465 scopus 로고    scopus 로고
    • Technical note: Correlation of respiratory motion between external patient surface and internal anatomical landmarks
    • Fayad H, Pan T, Clement JF, Visvikis D. Technical note: correlation of respiratory motion between external patient surface and internal anatomical landmarks. Med Phys 2011; 38:3157-3164.
    • (2011) Med Phys , vol.38 , pp. 3157-3164
    • Fayad, H.1    Pan, T.2    Clement, J.F.3    Visvikis, D.4
  • 13
    • 16344373639 scopus 로고    scopus 로고
    • The correlation between internal and external markers for abdominal tumors: Implications for respiratory gating
    • Gierga DP, Brewer J, Sharp GC, Betke M, Willett CG, Chen GT. The correlation between internal and external markers for abdominal tumors: implications for respiratory gating. Int J Radiat Oncol Biol Phys 2005; 61:1551-1558.
    • (2005) Int J Radiat Oncol Biol Phys , vol.61 , pp. 1551-1558
    • Gierga, D.P.1    Brewer, J.2    Sharp, G.C.3    Betke, M.4    Willett, C.G.5    Chen, G.T.6
  • 14
    • 10044224589 scopus 로고    scopus 로고
    • Evaluation of internal lung motion for respiratory-gated radiotherapy using MRI: Part I-correlating internal lung motion with skin fiducial motion
    • Koch N, Liu HH, Starkschall G, Jacobson M, Forster K, Liao Z, et al. Evaluation of internal lung motion for respiratory-gated radiotherapy using MRI: part I-correlating internal lung motion with skin fiducial motion. Int J Radiat Oncol Biol Phys 2004; 60:1459-1472.
    • (2004) Int J Radiat Oncol Biol Phys , vol.60 , pp. 1459-1472
    • Koch, N.1    Liu, H.H.2    Starkschall, G.3    Jacobson, M.4    Forster, K.5    Liao, Z.6
  • 17
    • 0346364988 scopus 로고    scopus 로고
    • Application of the spirometer in respiratory gated radiotherapy
    • Zhang T, Keller H, O'Brien MJ, Mackie TR, Paliwal B. Application of the spirometer in respiratory gated radiotherapy. Med Phys 2003; 30: 3165-3171.
    • (2003) Med Phys , vol.30 , pp. 3165-3171
    • Zhang, T.1    Keller, H.2    O'Brien, M.J.3    Mackie, T.R.4    Paliwal, B.5
  • 18
    • 78650160543 scopus 로고    scopus 로고
    • A comparison of the respiratory signals acquired by different respiratory monitoring systems used in respiratory gated radiotherapy
    • Otani Y, Fukuda I, Tsukamoto N, Kumazaki Y, Sekine H, Imabayashi E, et al. A comparison of the respiratory signals acquired by different respiratory monitoring systems used in respiratory gated radiotherapy. Med Phys 2010; 37:6178-6186.
    • (2010) Med Phys , vol.37 , pp. 6178-6186
    • Otani, Y.1    Fukuda, I.2    Tsukamoto, N.3    Kumazaki, Y.4    Sekine, H.5    Imabayashi, E.6
  • 19
    • 1542399631 scopus 로고    scopus 로고
    • Respiratory gating for 3-dimensional PET of the thorax: Feasibility and initial results
    • Boucher L, Rodrigue S, Lecomte R, Benard F. Respiratory gating for 3-dimensional PET of the thorax: feasibility and initial results. J Nucl Med 2004; 45:214-219.
    • (2004) J Nucl Med , vol.45 , pp. 214-219
    • Boucher, L.1    Rodrigue, S.2    Lecomte, R.3    Benard, F.4
  • 21
    • 35648931409 scopus 로고    scopus 로고
    • A method for synchronizing an external respiratory signal with a list-mode PET acquisition
    • Bruyant PP, Cheze Le Rest C, Turzo A, Jarritt P, Carson K, Visvikis D. A method for synchronizing an external respiratory signal with a list-mode PET acquisition. Med Phys 2007; 34:4472-4475.
    • (2007) Med Phys , vol.34 , pp. 4472-4475
    • Bruyant, P.P.1    Cheze Le Rest, C.2    Turzo, A.3    Jarritt, P.4    Carson, K.5    Visvikis, D.6
  • 23
    • 18344390040 scopus 로고    scopus 로고
    • Effect of respiratory gating on reducing lung motion artifacts in PET imaging of lung cancer
    • Nehmeh SA, Erdi YE, Ling CC, Rosenzweig KE, Squire OD, Braban LE, et al. Effect of respiratory gating on reducing lung motion artifacts in PET imaging of lung cancer. Med Phys 2002; 29:366-371.
    • (2002) Med Phys , vol.29 , pp. 366-371
    • Nehmeh, S.A.1    Erdi, Y.E.2    Ling, C.C.3    Rosenzweig, K.E.4    Squire, O.D.5    Braban, L.E.6
  • 24
    • 73449114294 scopus 로고    scopus 로고
    • Respiratory gating enhances imaging of pulmonary nodules and measurement of tracer uptake in FDG PET/CT
    • Werner MK, Parker JA, Kolodny GM, English JR, Palmer MR. Respiratory gating enhances imaging of pulmonary nodules and measurement of tracer uptake in FDG PET/CT. Am J Roentgenol 2009; 193:1640-1645.
    • (2009) Am J Roentgenol , vol.193 , pp. 1640-1645
    • Werner, M.K.1    Parker, J.A.2    Kolodny, G.M.3    English, J.R.4    Palmer, M.R.5
  • 28
    • 34347392321 scopus 로고    scopus 로고
    • Respiratory gating in positron emission tomography: A quantitative comparison of different gating schemes
    • Dawood M, Buther F, Lang N, Schober O, Schafers KP. Respiratory gating in positron emission tomography: a quantitative comparison of different gating schemes. Med Phys 2007; 34:3067-3076.
    • (2007) Med Phys , vol.34 , pp. 3067-3076
    • Dawood, M.1    Buther, F.2    Lang, N.3    Schober, O.4    Schafers, K.P.5
  • 29
    • 61449138067 scopus 로고    scopus 로고
    • Respiratory-gated positron emission tomography and breath-hold computed tomography coupling to reduce the influence of respiratory motion: Methodology and feasibility
    • Daouk J, Fin L, Bailly P, Meyer ME. Respiratory-gated positron emission tomography and breath-hold computed tomography coupling to reduce the influence of respiratory motion: methodology and feasibility. Acta Radiol 2009; 50:144-155.
    • (2009) Acta Radiol , vol.50 , pp. 144-155
    • Daouk, J.1    Fin, L.2    Bailly, P.3    Meyer, M.E.4
  • 31
    • 65449181578 scopus 로고    scopus 로고
    • Optimal number of respiratory gates in positron emission tomography: A cardiac patient study
    • Dawood M, Buther F, Stegger L, Jiang X, Schober O, Schafers M, et al. Optimal number of respiratory gates in positron emission tomography: a cardiac patient study. Med Phys 2009; 36:1775-1784.
    • (2009) Med Phys , vol.36 , pp. 1775-1784
    • Dawood, M.1    Buther, F.2    Stegger, L.3    Jiang, X.4    Schober, O.5    Schafers, M.6
  • 32
    • 84870942670 scopus 로고    scopus 로고
    • The effect of breathing irregularities on quantitative accuracy of respiratory gated PET/CT
    • Teo BK, Saboury B, Munbodh R, Scheuermann J, Torigian DA, Zaidi H, et al. The effect of breathing irregularities on quantitative accuracy of respiratory gated PET/CT. Med Phys 2012; 39:7390-7397.
    • (2012) Med Phys , vol.39 , pp. 7390-7397
    • Teo, B.K.1    Saboury, B.2    Munbodh, R.3    Scheuermann, J.4    Torigian, D.A.5    Zaidi, H.6
  • 33
    • 0019992105 scopus 로고
    • Quantitation in positron emission computed tomography: 6. Effect of nonuniform resolution
    • Hoffman EJ, Huang SC, Plummer D, Phelps ME. Quantitation in positron emission computed tomography: 6. Effect of nonuniform resolution. J Comput Assist Tomogr 1982; 6:987-999.
    • (1982) J Comput Assist Tomogr , vol.6 , pp. 987-999
    • Hoffman, E.J.1    Huang, S.C.2    Plummer, D.3    Phelps, M.E.4
  • 34
    • 33750579692 scopus 로고    scopus 로고
    • Improved quantitation for PET/CT image reconstruction with system modeling and anatomical priors
    • Alessio AM, Kinahan PE. Improved quantitation for PET/CT image reconstruction with system modeling and anatomical priors. Med Phys 2006; 33:4095-4103.
    • (2006) Med Phys , vol.33 , pp. 4095-4103
    • Alessio, A.M.1    Kinahan, P.E.2
  • 35
    • 72049122100 scopus 로고    scopus 로고
    • Number of partitions (gates) needed to obtain motion-free images in a respiratory gated 4D-PET/CT study as a function of the lesion size and motion displacement
    • Bettinardi V, Rapisarda E, Gilardi MC. Number of partitions (gates) needed to obtain motion-free images in a respiratory gated 4D-PET/CT study as a function of the lesion size and motion displacement. Med Phys 2009; 36:5547-5558.
    • (2009) Med Phys , vol.36 , pp. 5547-5558
    • Bettinardi, V.1    Rapisarda, E.2    Gilardi, M.C.3
  • 36
    • 84881606679 scopus 로고    scopus 로고
    • Challenges and opportunities in patient-specific, motion-managed and PET/CT-guided radiation therapy of lung cancer: Review and perspective
    • Bowen SR, Nyflot MJ, Gensheimer M, Hendrickson KR, Kinahan PE, Sandison GA, et al. Challenges and opportunities in patient-specific, motion-managed and PET/CT-guided radiation therapy of lung cancer: review and perspective. Clin Transl Med 2012; 1:1-18.
    • (2012) Clin Transl Med , vol.1 , pp. 1-18
    • Bowen, S.R.1    Nyflot, M.J.2    Gensheimer, M.3    Hendrickson, K.R.4    Kinahan, P.E.5    Sandison, G.A.6
  • 38
    • 34250667163 scopus 로고    scopus 로고
    • Deep-inspiration breath-hold PET/CT: Clinical findings with a new technique for detection and characterization of thoracic lesions
    • Meirelles GS, Erdi YE, Nehmeh SA, Squire OD, Larson SM, Humm JL, et al. Deep-inspiration breath-hold PET/CT: clinical findings with a new technique for detection and characterization of thoracic lesions. J Nucl Med 2007; 48:712-719.
    • (2007) J Nucl Med , vol.48 , pp. 712-719
    • Meirelles, G.S.1    Erdi, Y.E.2    Nehmeh, S.A.3    Squire, O.D.4    Larson, S.M.5    Humm, J.L.6
  • 39
    • 48749133710 scopus 로고    scopus 로고
    • Deep-inspiration breath-hold PET/CT of lung cancer: Maximum standardized uptake value analysis of 108 patients
    • Kawano T, Ohtake E, Inoue T. Deep-inspiration breath-hold PET/CT of lung cancer: maximum standardized uptake value analysis of 108 patients. J Nucl Med 2008; 49:1223-1231.
    • (2008) J Nucl Med , vol.49 , pp. 1223-1231
    • Kawano, T.1    Ohtake, E.2    Inoue, T.3
  • 40
    • 79954438614 scopus 로고    scopus 로고
    • Deep-inspiration breath-hold PET/CT versus free breathing PET/CT and respiratory gating PET for reference: Evaluation in 95 patients with lung cancer
    • Kawano T, Ohtake E, Inoue T. Deep-inspiration breath-hold PET/CT versus free breathing PET/CT and respiratory gating PET for reference: evaluation in 95 patients with lung cancer. Ann Nucl Med 2011; 25:109-116.
    • (2011) Ann Nucl Med , vol.25 , pp. 109-116
    • Kawano, T.1    Ohtake, E.2    Inoue, T.3
  • 41
    • 70349644861 scopus 로고    scopus 로고
    • Single 20-s acquisition of deep-inspiration breath-hold PET/CT: Clinical feasibility for lung cancer
    • Torizuka T, Tanizaki Y, Kanno T, Futatsubashi M, Yoshikawa E, Okada H, et al. Single 20-s acquisition of deep-inspiration breath-hold PET/CT: clinical feasibility for lung cancer. J Nucl Med 2009; 50:1579-1584.
    • (2009) J Nucl Med , vol.50 , pp. 1579-1584
    • Torizuka, T.1    Tanizaki, Y.2    Kanno, T.3    Futatsubashi, M.4    Yoshikawa, E.5    Okada, H.6
  • 42
    • 77954536870 scopus 로고    scopus 로고
    • Multi-bed-position acquisition technique for deep inspiration breath-hold PET/CT: A preliminary result for pulmonary lesions
    • Daisaki H, Shinohara H, Terauchi T, Murano T, Shimada N, Moriyama N, et al. Multi-bed-position acquisition technique for deep inspiration breath-hold PET/CT: a preliminary result for pulmonary lesions. Ann Nucl Med 2010; 24:179-188.
    • (2010) Ann Nucl Med , vol.24 , pp. 179-188
    • Daisaki, H.1    Shinohara, H.2    Terauchi, T.3    Murano, T.4    Shimada, N.5    Moriyama, N.6
  • 43
    • 77954533014 scopus 로고    scopus 로고
    • The reproducibility of deep-inspiration breath-hold (18)F-FDG PET/CT technique in diagnosing various cancers affected by respiratory motion
    • Nagamachi S, Wakamatsu H, Kiyohara S, Fujita S, Futami S, Arita H, et al. The reproducibility of deep-inspiration breath-hold (18)F-FDG PET/CT technique in diagnosing various cancers affected by respiratory motion. Ann Nucl Med 2010; 24:171-178.
    • (2010) Ann Nucl Med , vol.24 , pp. 171-178
    • Nagamachi, S.1    Wakamatsu, H.2    Kiyohara, S.3    Fujita, S.4    Futami, S.5    Arita, H.6
  • 45
    • 49949094416 scopus 로고    scopus 로고
    • Improved attenuation correction via appropriate selection of respiratory-correlated PET data
    • Daouk J, Fin L, Bailly P, Meyer ME. Improved attenuation correction via appropriate selection of respiratory-correlated PET data. Comput Methods Programs Biomed 2008; 92:90-98.
    • (2008) Comput Methods Programs Biomed , vol.92 , pp. 90-98
    • Daouk, J.1    Fin, L.2    Bailly, P.3    Meyer, M.E.4
  • 46
    • 53649100554 scopus 로고    scopus 로고
    • Initial clinical results for breath-hold CT-based processing of respiratory-gated PET acquisitions
    • Fin L, Daouk J, Morvan J, Bailly P, El Esper I, Saidi L, et al. Initial clinical results for breath-hold CT-based processing of respiratory-gated PET acquisitions. Eur J Nucl Med Mol Imaging 2008; 35:1971-1980.
    • (2008) Eur J Nucl Med Mol Imaging , vol.35 , pp. 1971-1980
    • Fin, L.1    Daouk, J.2    Morvan, J.3    Bailly, P.4    El Esper, I.5    Saidi, L.6
  • 48
    • 51049117682 scopus 로고    scopus 로고
    • AW-OSEM parameter optimization for selected events related to the breath-hold CT position in respiratory-gated PET acquisition
    • 14-17 May, Paris, France
    • Daouk J, Fin L, Bailly P, Meyer M-E. AW-OSEM parameter optimization for selected events related to the breath-hold CT position in respiratory-gated PET acquisition. Fifth IEEE International Symposium on Biomedical Imaging; 14-17 May, Paris, France; 2008. pp. 1323-1326.
    • (2008) Fifth IEEE International Symposium on Biomedical Imaging , pp. 1323-1326
    • Daouk, J.1    Fin, L.2    Bailly, P.3    Meyer, M.-E.4
  • 52
    • 75149114655 scopus 로고    scopus 로고
    • Implementation of an automated respiratory amplitude gating technique for PET/CT: Clinical evaluation
    • Chang G, Chang T, Pan T, Clark JW Jr, Mawlawi OR. Implementation of an automated respiratory amplitude gating technique for PET/CT: clinical evaluation. J Nucl Med 2010; 51:16-24.
    • (2010) J Nucl Med , vol.51 , pp. 16-24
    • Chang, G.1    Chang, T.2    Pan, T.3    Clark Jr., J.W.4    Mawlawi, O.R.5
  • 53
    • 0642372122 scopus 로고    scopus 로고
    • Reduction of respiratory motion artifacts in PET imaging of lung cancer by respiratory correlated dynamic PET: Methodology and comparison with respiratory gated PET
    • Nehmeh SA, Erdi YE, Rosenzweig KE, Schoder H, Larson SM, Squire OD, et al. Reduction of respiratory motion artifacts in PET imaging of lung cancer by respiratory correlated dynamic PET: methodology and comparison with respiratory gated PET. J Nucl Med 2003; 44:1644-1648.
    • (2003) J Nucl Med , vol.44 , pp. 1644-1648
    • Nehmeh, S.A.1    Erdi, Y.E.2    Rosenzweig, K.E.3    Schoder, H.4    Larson, S.M.5    Squire, O.D.6
  • 54
    • 33749382047 scopus 로고    scopus 로고
    • List-mode affine rebinning for respiratory motion correction in PET cardiac imaging
    • Yang G-Z, editor, Berlin, Heidelberg: Springer-Verlag
    • Chung AJ, Camici PG, Yang G-Z. List-mode affine rebinning for respiratory motion correction in PET cardiac imaging. In: Yang G-Z, editor. International Workshop on Medical Image and Augmented Reality, Shanghai. Berlin, Heidelberg: Springer-Verlag; 2006. pp. 293-300.
    • (2006) International Workshop on Medical Image and Augmented Reality, Shanghai , pp. 293-300
    • Chung, A.J.1    Camici, P.G.2    Yang, G.-Z.3
  • 55
    • 34247281725 scopus 로고    scopus 로고
    • Respiratory motion correction for PET oncology applications using affine transformation of list mode data
    • Lamare F, Cresson T, Savean J, Cheze Le Rest C, Reader AJ, Visvikis D. Respiratory motion correction for PET oncology applications using affine transformation of list mode data. Phys Med Biol 2007; 52:121-140.
    • (2007) Phys Med Biol , vol.52 , pp. 121-140
    • Lamare, F.1    Cresson, T.2    Savean, J.3    Cheze Le Rest, C.4    Reader, A.J.5    Visvikis, D.6
  • 56
    • 22244488754 scopus 로고    scopus 로고
    • Rigid-body transformation of list-mode projection data for respiratory motion correction in cardiac PET
    • Livieratos L, Stegger L, Bloomfield PM, Schafers K, Bailey DL, Camici PG. Rigid-body transformation of list-mode projection data for respiratory motion correction in cardiac PET. Phys Med Biol 2005; 50:3313-3322.
    • (2005) Phys Med Biol , vol.50 , pp. 3313-3322
    • Livieratos, L.1    Stegger, L.2    Bloomfield, P.M.3    Schafers, K.4    Bailey, D.L.5    Camici, P.G.6
  • 57
    • 8344282876 scopus 로고    scopus 로고
    • Motion compensation in histogram-mode and list-mode em reconstructions: Beyond the event-driven approach
    • Rahmim A, Bloomfield P, Houle S, Lenox M, Michel C, Buckley KR, et al. Motion compensation in histogram-mode and list-mode EM reconstructions: beyond the event-driven approach. IEEE Trans Nucl Sci 2004; 51: 2588-2596.
    • (2004) IEEE Trans Nucl Sci , vol.51 , pp. 2588-2596
    • Rahmim, A.1    Bloomfield, P.2    Houle, S.3    Lenox, M.4    Michel, C.5    Buckley, K.R.6
  • 59
    • 11844256362 scopus 로고    scopus 로고
    • Image reconstruction of motion corrected sonograms
    • 2003 IEEE; 19-25 October, Portland, Oregon, USA
    • Thielemans K, Mustafovic S, Schnorr L. Image reconstruction of motion corrected sonograms. Nuclear Science Symposium Conference Record, 2003 IEEE; 19-25 October, Portland, Oregon, USA; 2003. pp. 2401-2406.
    • (2003) Nuclear Science Symposium Conference Record , pp. 2401-2406
    • Thielemans, K.1    Mustafovic, S.2    Schnorr, L.3
  • 61
    • 0025404969 scopus 로고
    • Bayesian reconstructions from emission tomography data using a modified em algorithm
    • Green PJ. Bayesian reconstructions from emission tomography data using a modified EM algorithm. IEEE Trans Med Imaging 1990; 9:84-93.
    • (1990) IEEE Trans Med Imaging , vol.9 , pp. 84-93
    • Green, P.J.1
  • 62
    • 0028700063 scopus 로고
    • Accelerated image reconstruction using ordered subsets of projection data
    • Hudson H, Larkin R. Accelerated image reconstruction using ordered subsets of projection data. IEEE Trans Med Imaging 1994; 13:601-609.
    • (1994) IEEE Trans Med Imaging , vol.13 , pp. 601-609
    • Hudson, H.1    Larkin, R.2
  • 63
    • 0020194763 scopus 로고
    • Maximum likelihood reconstruction for emission tomography
    • Shepp L, Vardi Y. Maximum likelihood reconstruction for emission tomography. IEEE Trans Med Imaging 1982; 1:113-122.
    • (1982) IEEE Trans Med Imaging , vol.1 , pp. 113-122
    • Shepp, L.1    Vardi, Y.2
  • 64
    • 70349443218 scopus 로고    scopus 로고
    • Motion correction based on an appropriate system matrix for statistical reconstruction of respiratory-correlated PET acquisitions
    • Fin L, Bailly P, Daouk J, Meyer ME. Motion correction based on an appropriate system matrix for statistical reconstruction of respiratory- correlated PET acquisitions. Comput Methods Programs Biomed 2009; 96:e1-e9.
    • (2009) Comput Methods Programs Biomed , vol.96
    • Fin, L.1    Bailly, P.2    Daouk, J.3    Meyer, M.E.4
  • 65
    • 36048972941 scopus 로고    scopus 로고
    • List-mode-based reconstruction for respiratory motion correction in PET using non-rigid body transformations
    • Lamare F, Ledesma Carbayo MJ, Cresson T, Kontaxakis G, Santos A, Le Rest CC, et al. List-mode-based reconstruction for respiratory motion correction in PET using non-rigid body transformations. Phys Med Biol 2007; 52:5187-5204.
    • (2007) Phys Med Biol , vol.52 , pp. 5187-5204
    • Lamare, F.1    Ledesma Carbayo, M.J.2    Cresson, T.3    Kontaxakis, G.4    Santos, A.5    Le Rest, C.C.6
  • 66
    • 33646440883 scopus 로고    scopus 로고
    • Model-based image reconstruction for four-dimensional PET
    • Li T, Thorndyke B, Schreibmann E, Yang Y, Xing L. Model-based image reconstruction for four-dimensional PET. Med Phys 2006; 33:1288-1298.
    • (2006) Med Phys , vol.33 , pp. 1288-1298
    • Li, T.1    Thorndyke, B.2    Schreibmann, E.3    Yang, Y.4    Xing, L.5
  • 67
    • 33746512521 scopus 로고    scopus 로고
    • A motion-incorporated reconstruction method for gated PET studies
    • Qiao F, Pan T, Clark JW Jr, Mawlawi OR. A motion-incorporated reconstruction method for gated PET studies. Phys Med Biol 2006; 51:3769-3783.
    • (2006) Phys Med Biol , vol.51 , pp. 3769-3783
    • Qiao, F.1    Pan, T.2    Clark, Jr.J.W.3    Mawlawi, O.R.4
  • 71
    • 0038720462 scopus 로고    scopus 로고
    • Three-dimensional motion estimation with image reconstruction for gated cardiac ECT
    • Cao Z, Gilland DR, Mair BA, Jaszczak RJ. Three-dimensional motion estimation with image reconstruction for gated cardiac ECT. IEEE Trans Nucl Sci 2003; 50:384-388.
    • (2003) IEEE Trans Nucl Sci , vol.50 , pp. 384-388
    • Cao, Z.1    Gilland, D.R.2    Mair, B.A.3    Jaszczak, R.J.4
  • 72
    • 17644401707 scopus 로고    scopus 로고
    • Motion-compensated reconstruction of tomographic image sequences
    • Gravier EJ, Yongyi Y. Motion-compensated reconstruction of tomographic image sequences. IEEE Trans Nucl Sci 2005; 52:51-56.
    • (2005) IEEE Trans Nucl Sci , vol.52 , pp. 51-56
    • Gravier, E.J.1    Yongyi, Y.2
  • 73
    • 11944261245 scopus 로고    scopus 로고
    • Joint estimation of image and deformation parameters in motion-corrected PET
    • 2003 IEEE; 19-25 October, Portland, Oregon, USA
    • Jacobson MW, Fessler JA. Joint estimation of image and deformation parameters in motion-corrected PET. Nuclear Science Symposium Conference Record, 2003 IEEE; 19-25 October, Portland, Oregon, USA; 2003. pp. 3290-3294.
    • (2003) Nuclear Science Symposium Conference Record , pp. 3290-3294
    • Jacobson, M.W.1    Fessler, J.A.2
  • 74
    • 36648999151 scopus 로고    scopus 로고
    • Joint model of motion and anatomy for PET image reconstruction
    • Qiao F, Clark JW, Pan T, Mawlawi O. Joint model of motion and anatomy for PET image reconstruction. Med Phys 2007; 34:4626-4639.
    • (2007) Med Phys , vol.34 , pp. 4626-4639
    • Qiao, F.1    Clark, J.W.2    Pan, T.3    Mawlawi, O.4
  • 76
    • 67649882488 scopus 로고    scopus 로고
    • Regularized B-spline deformable registration for respiratory motion correction in PET images
    • Bai W, Brady M. Regularized B-spline deformable registration for respiratory motion correction in PET images. Phys Med Biol 2009; 54:2719-2736.
    • (2009) Phys Med Biol , vol.54 , pp. 2719-2736
    • Bai, W.1    Brady, M.2
  • 77
    • 48549091398 scopus 로고    scopus 로고
    • Respiratory motion correction in 3-D PET data with advanced optical flow algorithms
    • Dawood M, Buther F, Jiang X, Schafers KP. Respiratory motion correction in 3-D PET data with advanced optical flow algorithms. IEEE Trans Med Imaging 2008; 27:1164-1175.
    • (2008) IEEE Trans Med Imaging , vol.27 , pp. 1164-1175
    • Dawood, M.1    Buther, F.2    Jiang, X.3    Schafers, K.P.4
  • 78
  • 79
    • 84867968239 scopus 로고    scopus 로고
    • Respiratory motion correction with an improved demons algorithm for PET image
    • Gao J, Chai P, Yun M-K, Liu S-Q, Bao-Ci S, Wei L. Respiratory motion correction with an improved demons algorithm for PET image. Chinese Phys C 2012; 36:1025-1030.
    • (2012) Chinese Phys C , vol.36 , pp. 1025-1030
    • Gao, J.1    Chai, P.2    Yun, M.-K.3    Liu, S.-Q.4    Bao-Ci, S.5    Wei, L.6
  • 82
    • 77956188071 scopus 로고    scopus 로고
    • PET/CT (and CT) instrumentation, image reconstruction and data transfer for radiotherapy planning
    • Sattler B, Lee JA, Lonsdale M, Coche E. PET/CT (and CT) instrumentation, image reconstruction and data transfer for radiotherapy planning. Radiother Oncol 2010; 96:288-297.
    • (2010) Radiother Oncol , vol.96 , pp. 288-297
    • Sattler, B.1    Lee, J.A.2    Lonsdale, M.3    Coche, E.4
  • 84
    • 79958840226 scopus 로고    scopus 로고
    • Nonrigid PET motion compensation in the lower abdomen using simultaneous tagged-MRI and PET imaging
    • Guerin B, Cho S, Chun SY, Zhu X, Alpert NM, El Fakhri G, et al. Nonrigid PET motion compensation in the lower abdomen using simultaneous tagged-MRI and PET imaging. Med Phys 2011; 38:3025-3038.
    • (2011) Med Phys , vol.38 , pp. 3025-3038
    • Guerin, B.1    Cho, S.2    Chun, S.Y.3    Zhu, X.4    Alpert, N.M.5    El Fakhri, G.6
  • 85
    • 84874915268 scopus 로고    scopus 로고
    • Respiratory motion correction in oncologic PET using T1-weighted MR imaging on a simultaneous whole-body PET/MR system
    • Wurslin C, Schmidt H, Martirosian P, Brendle C, Boss A, Schwenzer NF, et al. Respiratory motion correction in oncologic PET using T1-weighted MR imaging on a simultaneous whole-body PET/MR system. J Nucl Med 2013; 54:464-471.
    • (2013) J Nucl Med , vol.54 , pp. 464-471
    • Wurslin, C.1    Schmidt, H.2    Martirosian, P.3    Brendle, C.4    Boss, A.5    Schwenzer, N.F.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.