Nonrigid PET motion compensation in the lower abdomen using simultaneous tagged-MRI and PET imaging

Author keywords

fully 3D reconstruction; motion correction; simultaneous PET MRI acquisitions; tagged MRI

Indexed keywords

DEFORMATION; HISTOLOGY; IMAGE RECONSTRUCTION; MAGNETIC RESONANCE IMAGING; MOTION COMPENSATION; MOTION ESTIMATION; PHANTOMS; POSITRON EMISSION TOMOGRAPHY; RESPIRATORY MECHANICS; SIGNAL TO NOISE RATIO; TISSUE; TISSUE ENGINEERING;

EID: 79958840226     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3589136     Document Type: Article
Times cited : (101)

References (55)
  • 1
    • 77949261532 scopus 로고    scopus 로고
    • Dual-gated cardiac PET-Clinical feasibility study
    • 10.1007/s00259-009-1252-4
    • M. Ters Dual-gated cardiac PET-Clinical feasibility study., Eur. J. Nucl. Med. Mol. Imaging 37, 505-516 (2009). 10.1007/s00259-009-1252-4
    • (2009) Eur. J. Nucl. Med. Mol. Imaging , vol.37 , pp. 505-516
    • Ters, M.1
  • 2
    • 0031212835 scopus 로고    scopus 로고
    • Non-rigid summing of gated PET via optical flow
    • 10.1109/23.632704
    • G. J. Klein, B. W. Reutter, and R. H. Huesman, Non-rigid summing of gated PET via optical flow., IEEE Trans. Nucl. Sci. 44, 1509-1512 (1997). 10.1109/23.632704
    • (1997) IEEE Trans. Nucl. Sci. , vol.44 , pp. 1509-1512
    • Klein, G.J.1    Reutter, B.W.2    Huesman, R.H.3
  • 4
    • 28544440972 scopus 로고    scopus 로고
    • Respiratory motion artefact in the liver dome on FDG PET/CT: Comparison of attenuation correction with CT and a caesium external source
    • DOI 10.1007/s00259-005-1868-y
    • D. Papathanassiou, S. Becker, A. Amir, B. Menroux, and J. C. Liehn, Respiratory motion artifact in the liver dome on FDG PET/CT: comparison of attenuation correction with CT and a caesium external source., Eur. J. Nucl. Med. Mol. Imaging 32, 1422-1428 (2005). 10.1007/s00259-005-1868-y (Pubitemid 41746847)
    • (2005) European Journal of Nuclear Medicine and Molecular Imaging , vol.32 , Issue.12 , pp. 1422-1428
    • Papathanassiou, D.1    Becker, S.2    Amir, R.3    Meneroux, B.4    Liehn, J.-C.5
  • 5
    • 0037884881 scopus 로고    scopus 로고
    • Respiratory motion artifacts on PET emission images obtained using CT attenuation correction on PET-CT
    • 10.1007/s00259-002-1024-x
    • M. M. Osman, C. Cohade, Y. Nakamoto, and R. L. Wahl, Respiratory motion artifacts on PET emission images obtained using CT attenuation correction on PET-CT., Eur. J. Nucl. Med. Mol. Imaging 30, 1619-7070 (2003). 10.1007/s00259-002-1024-x
    • (2003) Eur. J. Nucl. Med. Mol. Imaging , vol.30 , pp. 1619-7070
    • Osman, M.M.1    Cohade, C.2    Nakamoto, Y.3    Wahl, R.L.4
  • 7
    • 0642372122 scopus 로고    scopus 로고
    • Reduction of respiratory motion artifacts in PET imaging of lung cancer by respiratory correlated dynamic PET: Methodology and comparison with respiratory gated PET
    • S. A. Nehmeh, Y. E. Erdi, K. E. Rosenzweig, H. Schoder, S. M. Larson, O. D. Squire, and J. L. Humm, Reduction of respiratory motion artifacts in PET imaging of lung cancer by respiratory correlated dynamic PET: methodology and comparison with respiratory gated PET., J. Nucl. Med. 44, 1644-1648 (2003). (Pubitemid 39663338)
    • (2003) Journal of Nuclear Medicine , vol.44 , Issue.10 , pp. 1644-1648
    • Nehmeh, S.A.1    Erdi, Y.E.2    Rosenzweig, K.E.3    Schoder, H.4    Larson, S.M.5    Squire, O.D.6    Humm, J.L.7
  • 9
    • 0033311379 scopus 로고    scopus 로고
    • Practical 3D tomographic method for correcting patient head motion in clinical SPECT
    • DOI 10.1109/23.775596
    • R. R. Fulton, S. Eberl, S. R. Meikle, B. F. Hutton, and M. Braun, A practical 3D tomographic method for correcting patient head motion in clinical SPECT., IEEE Trans. Nucl. Sci. 46, 667-672 (1999). 10.1109/23.775596 (Pubitemid 30504967)
    • (1999) IEEE Transactions on Nuclear Science , vol.46 , Issue.II3 , pp. 667-672
    • Fulton, R.R.1    Eberl, S.2    Meikle, S.R.3    Hutton, B.F.4    Braun, M.5
  • 11
    • 8344252935 scopus 로고    scopus 로고
    • Feasibility of stereo-infrared tracking to monitor patient motion during cardiac SPECT imaging
    • 10.1109/TNS.2004.835786
    • R. D. Beach Feasibility of stereo-infrared tracking to monitor patient motion during cardiac SPECT imaging., IEEE Trans. Nucl. Sci. 51, 2693-2698 (2004). 10.1109/TNS.2004.835786
    • (2004) IEEE Trans. Nucl. Sci. , vol.51 , pp. 2693-2698
    • Beach, R.D.1
  • 12
    • 0142179125 scopus 로고    scopus 로고
    • Sinogram-based motion correction of PET images using optical motion tracking system and list-mode data acquisition
    • S. K. Woo, H. Watabe, Y. Choi, K. M. Kim, C. C. Park, and H. Iida, Sinogram-based motion correction of PET images using optical motion tracking system and list-mode data acquisition., IEEE Trans. Nucl. Sci. 2, 830-834 (2002).
    • (2002) IEEE Trans. Nucl. Sci. , vol.2 , pp. 830-834
    • Woo, S.K.1    Watabe, H.2    Choi, Y.3    Kim, K.M.4    Park, C.C.5    Iida, H.6
  • 14
    • 34247281725 scopus 로고    scopus 로고
    • Respiratory motion correction for PET oncology applications using affine transformation of list mode data
    • DOI 10.1088/0031-9155/52/1/009, PII S0031915507302376, 009
    • F. Lamare, T. Cresson, J. Savean, C. Cheze Le Rest, A. J. Reader, and D. Visvikis, Respiratory motion correction for PET oncology applications using affine transformation of list mode data., Phys. Med. Biol. 52, 121-140 (2007). 10.1088/0031-9155/52/1/009 (Pubitemid 46646270)
    • (2007) Physics in Medicine and Biology , vol.52 , Issue.1 , pp. 121-140
    • Lamare, F.1    Cresson, T.2    Savean, J.3    Cheze Le Rest, C.4    Reader, A.J.5    Visvikis, D.6
  • 16
    • 33746512521 scopus 로고    scopus 로고
    • A motion-incorporated reconstruction method for gated PET studies
    • DOI 10.1088/0031-9155/51/15/012, PII S0031915506183074, 012
    • F. Qiao, T. Pan, J. W. Clark, and O. R. Malawi, A motion-incorporated reconstruction method for gated PET studies., Phys. Med. Biol. 51, 3769-3783 (2006). 10.1088/0031-9155/51/15/012 (Pubitemid 44131364)
    • (2006) Physics in Medicine and Biology , vol.51 , Issue.15 , pp. 3769-3783
    • Qiao, F.1    Pan, T.2    Clark Jr., J.W.3    Mawlawi, O.R.4
  • 17
    • 34247472261 scopus 로고    scopus 로고
    • 4D MR imaging of respiratory organ motion and its variability
    • DOI 10.1088/0031-9155/52/6/001, PII S0031915507275505, 001
    • M. Von Siebenthal, G. Szkely, U. Gamper, P. Boesiger, A. Lomax, and P. Cattin, 4D MR imaging of respiratory organ motion and its variability., Phys. Med. Biol. 52, 1547-1564 (2007). 10.1088/0031-9155/52/6/001 (Pubitemid 46646366)
    • (2007) Physics in Medicine and Biology , vol.52 , Issue.6 , pp. 1547-1564
    • Von Siebenthal, M.1    Szekely, G.2    Gamper, U.3    Boesiger, P.4    Lomax, A.5    Cattin, Ph.6
  • 18
    • 23244445127 scopus 로고    scopus 로고
    • Modelling respiratory motion for optimisation of lung cancer radiotherapy using fast MR imaging and intensity-based image registration
    • (Berlin, Germany, 2007), Vol.
    • J. M. Blackall, S. Ahmad, M. Miquel, D. Landau, and D. Hawkes, Modelling respiratory motion for optimisation of lung cancer radiotherapy using fast MR imaging and intensity-based image registration., Proc. Int. Soc. Magn. Reson. Med. (Berlin, Germany, 2007), Vol. 11, p. 2610.
    • Proc. Int. Soc. Magn. Reson. Med. , vol.11 , pp. 2610
    • Blackall, J.M.1    Ahmad, S.2    Miquel, M.3    Landau, D.4    Hawkes, D.5
  • 20
    • 0030026702 scopus 로고    scopus 로고
    • Navigator-echo-based real-time respiratory gating and triggering for reduction of respiration effects in three-dimensional coronary MR angiography
    • Y. Wang, P. J. Rossman, R. C. Grimm, S. J. Riederer, and R. L. Ehman, Navigator-echo-based real-time respiratory gating and triggering for reduction of respiration effects in three-dimensional coronary MR angiography., Radiology 198, 55-60 (1996). (Pubitemid 26008240)
    • (1996) Radiology , vol.198 , Issue.1 , pp. 55-60
    • Wang, Y.1    Rossman, P.J.2    Grimm, R.C.3    Riederer, S.J.4    Ehman, R.L.5
  • 21
    • 11944261245 scopus 로고    scopus 로고
    • Joint estimation of image and deformation parameters in motion-corrected PET
    • M16-8, 2003 IEEE Nuclear Science Symposium Conference Record - Nuclear Science Symposium, Medical Imaging Conference
    • M. W. Jacobson and J. A. Fessler, Joint estimation of image and deformation parameters in motion-corrected PET., Proceedings of the IEEE Nuclear Science Symposium Medical Imaging Conference, 2003, Vol. 5, pp. 3290-3294. (Pubitemid 40100103)
    • (2003) IEEE Nuclear Science Symposium Conference Record , vol.5 , pp. 3290-3294
    • Jacobson, M.W.1    Fessler, J.A.2
  • 22
    • 22244488754 scopus 로고    scopus 로고
    • Rigid-body transformation of list-mode projection data for respiratory motion correction in cardiac PET
    • DOI 10.1088/0031-9155/50/14/008
    • L. Livieratos, L. Stegger, P. M. Bloomfield, K. Schafers, D. L. Bailey, and P. G. Camici, Rigid-body transformation of list-mode projection data for respiratory motion correction in cardiac PET., Phys. Med.Biol. 50, 3313-3322 (2005). 10.1088/0031-9155/50/14/008 (Pubitemid 40991691)
    • (2005) Physics in Medicine and Biology , vol.50 , Issue.14 , pp. 3313-3322
    • Livieratos, L.1    Stegger, L.2    Bloomfield, P.M.3    Schafers, K.4    Bailey, D.L.5    Camici, P.G.6
  • 23
    • 48549091398 scopus 로고    scopus 로고
    • Respiratory motion correction in 3-D PET data with advanced optical flow algorithms
    • 10.1109/TMI.2008.918321
    • M. Dawood, F. Buther, X. Jiang, and K. Schafers, Respiratory motion correction in 3-D PET data with advanced optical flow algorithms., IEEE Trans. Med. Imaging 27, 1164-1175 (2008). 10.1109/TMI.2008.918321
    • (2008) IEEE Trans. Med. Imaging , vol.27 , pp. 1164-1175
    • Dawood, M.1    Buther, F.2    Jiang, X.3    Schafers, K.4
  • 24
    • 0035355169 scopus 로고    scopus 로고
    • Four-dimensional affine registration models for respiratory-gated PET
    • DOI 10.1109/23.940159, PII S0018949901050900
    • G. J. Klein, R. W. Reutter, and R. H. Huesman, Four-dimensional affine registration models for respiratory-gated PET., IEEE Trans. Nucl. Sci. 48, 756-760 (2001). 10.1109/23.940159 (Pubitemid 32945686)
    • (2001) IEEE Transactions on Nuclear Science , vol.48 , Issue.II3 , pp. 756-760
    • Klein, G.J.1    Reutter, B.W.2    Huesman, R.H.3
  • 26
    • 34247199659 scopus 로고    scopus 로고
    • Simultaneous acquisition of multislice PET and MR images: Initial results with a MR-compatible PET scanner
    • C. Catana, Y. Wu, M. S. Judenhofer, J. Qi, B. J. Pichler, and S. R. Cherry, Simultaneous acquisition of multislice PET and MR images: initial results with a MR-compatible PET scanner., J. Nucl. Med. 47, 1968-1976 (2006). (Pubitemid 47544984)
    • (2006) Journal of Nuclear Medicine , vol.47 , Issue.12 , pp. 1968-1976
    • Catana, C.1    Wu, Y.2    Judenhofer, M.S.3    Qi, J.4    Pichler, B.J.5    Cherry, S.R.6
  • 28
    • 0021282475 scopus 로고
    • Measurement of flow with NMR imaging using a gradient pulse and phase difference technique
    • D. J. Bryant, J. A. Payne, D. N. Firmin, and D. B. Longmore, Measurement of flow with NMR imaging using a gradient pulse and phase difference technique., J. Comput. Assist. Tomogr. 8, 588-593 (1984). 10.1097/00004728-198408000-00002 (Pubitemid 14097044)
    • (1984) Journal of Computer Assisted Tomography , vol.8 , Issue.4 , pp. 588-593
    • Bryant, D.J.1    Payne, J.A.2    Firmin, D.N.3    Longmore, D.B.4
  • 32
    • 0024307534 scopus 로고
    • Heart wall motion: Improved method for spatial modulation of magnetization for MR imaging
    • L. Axel and L. Dougherty, Heart wall motion: improved method of spatial modulation of magnetization for MR imaging., Radiology 172, 349-350 (1989). (Pubitemid 19184866)
    • (1989) Radiology , vol.172 , Issue.2 , pp. 349-350
    • Axel, L.1    Dougherty, L.2
  • 33
    • 0024318208 scopus 로고
    • MR imaging of motion with spatial modulation of magnetization
    • L. Axel and L. Dougherty, MR imaging of motion with spatial modulation of magnetization., Radiology 171, 841-845 (1989). (Pubitemid 19134952)
    • (1989) Radiology , vol.171 , Issue.3 , pp. 841-845
    • Axel, L.1    Dougherty, L.2
  • 34
    • 0033623972 scopus 로고    scopus 로고
    • Imaging heart motion using harmonic phase MRI
    • 10.1109/42.845177
    • N. F. Osman, E. R. McVeigh, and J. L. Prince, Imaging heart motion using harmonic phase MRI., IEEE Trans. Med. Imaging 19, 186-202 (2000). 10.1109/42.845177
    • (2000) IEEE Trans. Med. Imaging , vol.19 , pp. 186-202
    • Osman, N.F.1    McVeigh, E.R.2    Prince, J.L.3
  • 35
    • 21244439948 scopus 로고    scopus 로고
    • Estimating motion from MRI data
    • DOI 10.1109/JPROC.2003.817872, Emerging Medical Imaging Technology
    • C. Ozturk, J. A. Derbyshire, and E. R. MCVeigh, Estimating motion from MRI data., Proc. IEEE 91, 1627-1648 (2003). 10.1109/JPROC.2003.817872 (Pubitemid 40890808)
    • (2003) Proceedings of the IEEE , vol.91 , Issue.10 , pp. 1627-1647
    • Ozturk, C.1    Derbyshire, J.A.2    McVeigh, E.R.3
  • 36
    • 85027227744 scopus 로고    scopus 로고
    • Online issue of International Hospital and Solutions.
    • Online issue of International Hospital and Solutions: http://www.ihe-online.com/feature-articles/science-fiction-becomes-reality- europes-first-full-body-petmr-system/index.html.
  • 37
    • 85027221372 scopus 로고    scopus 로고
    • Online issue of International Hospital.
    • Online issue of International Hospital: http://www.european-hospital.com/ en/article/6628.html.
  • 38
    • 0028397086 scopus 로고
    • Tag and contour detection in tagged MR images of the left ventricle
    • 10.1109/42.276146
    • M. A. Guttman, J. L. Prince, and E. R. McVeigh, Tag and contour detection in tagged MR images of the left ventricle., IEEE Trans. Med.Imaging 13, 74-88 (1994). 10.1109/42.276146
    • (1994) IEEE Trans. Med.Imaging , vol.13 , pp. 74-88
    • Guttman, M.A.1    Prince, J.L.2    McVeigh, E.R.3
  • 39
    • 0028392926 scopus 로고
    • Automatic tracking of SPAMM grid and the estimation of deformation parameters from cardiac MR images
    • 10.1109/42.276150
    • S. Kumar and D. Goldgof, Automatic tracking of SPAMM grid and the estimation of deformation parameters from cardiac MR images., IEEE Trans. Med. Imaging 13, 122-132 (1993). 10.1109/42.276150
    • (1993) IEEE Trans. Med. Imaging , vol.13 , pp. 122-132
    • Kumar, S.1    Goldgof, D.2
  • 40
    • 0029029302 scopus 로고
    • Three-dimensional myocardial deformations: Calculations with displacement field fitting of tagged MR images
    • W.
    • W. G. O'Dell, C. C. Moore, W. C. Hunter, E. A. Zerhouni, and E. R. McVeigh, Three-dimensional myocardial deformations: calculations with displacement field fitting of tagged MR images., Radiology 195, 829-835 (1995).
    • (1995) Radiology , vol.195 , pp. 829-835
    • O'Dell, G.1    Moore, C.C.2    Hunter, W.C.3    Zerhouni, E.A.4    McVeigh, E.R.5
  • 41
    • 0029505977 scopus 로고
    • Reconstruction of 3-D left ventricular motion from planar tagged cardiac MR images: An estimation theoretic approach
    • 10.1109/42.476104
    • T. S. Denney and J. L. Prince, Reconstruction of 3-D left ventricular motion from planar tagged cardiac MR images: an estimation theoretic approach., IEEE Trans. Med. Imaging 14, 625-635 (1995). 10.1109/42.476104
    • (1995) IEEE Trans. Med. Imaging , vol.14 , pp. 625-635
    • Denney, T.S.1    Prince, J.L.2
  • 42
    • 0029716890 scopus 로고    scopus 로고
    • Deformable B-solids and implicit snakes for localization and tracking of SPAMM MRI-data
    • (San Francisco, CA)
    • P. Radeva, A. Amini, J. Huang, and E. Marti, Deformable B-solids and implicit snakes for localization and tracking of SPAMM MRI-data., Proceedings of the MMBIA (San Francisco, CA, 1996), pp. 192-201.
    • (1996) Proceedings of the MMBIA , pp. 192-201
    • Radeva, P.1    Amini, A.2    Huang, J.3    Marti, E.4
  • 44
    • 33750391994 scopus 로고    scopus 로고
    • Calculation of the Sensitivity Image in List-Mode Reconstruction for PET
    • DOI 10.1109/TNS.2006.882298, 1710264
    • J. Qi, Calculation of the sensitivity image in list-mode reconstruction for PET., IEEE Trans. Nucl. Sci. 53, 2746-2751 (2006). 10.1109/TNS.2006.882298 (Pubitemid 44637023)
    • (2006) IEEE Transactions on Nuclear Science , vol.53 , Issue.5 , pp. 2746-2751
    • Qi, J.1
  • 45
    • 57349155316 scopus 로고    scopus 로고
    • MR-Based attenuation correction for PET/MR: A novel approach combining pattern recognition and atlas registration
    • 10.2967/jnumed.107.049353
    • M. Hofmann MR-Based attenuation correction for PET/MR: a novel approach combining pattern recognition and atlas registration., J. Nucl. Med. 49, 875-1883 (2008). 10.2967/jnumed.107.049353
    • (2008) J. Nucl. Med. , vol.49 , pp. 875-1883
    • Hofmann, M.1
  • 46
    • 60549086399 scopus 로고    scopus 로고
    • Towards quantitative PET/MR: A review of MR-base attenuation correction technique
    • 10.1007/s00259-008-1007-7
    • M. Hofmann, B. Pichler, B. Schlkopf, and T. Beyer, Towards quantitative PET/MR: a review of MR-base attenuation correction technique., Eur. J. Nucl. Med. Mol. Imaging 36, S93-S104 (2009). 10.1007/s00259-008-1007-7
    • (2009) Eur. J. Nucl. Med. Mol. Imaging , vol.36
    • Hofmann, M.1    Pichler, B.2    Schlkopf, B.3    Beyer, T.4
  • 48
    • 43749114975 scopus 로고    scopus 로고
    • MR-based attenuation correction for torso-PET/MR imaging: Pitfalls in mapping MR to CT data
    • 10.1007/s00259-008-0734-0
    • T. Beyer MR-based attenuation correction for torso-PET/MR imaging: pitfalls in mapping MR to CT data., Eur. J. Nucl. Med. Mol. Imaging 35, 1142-1146 (2008). 10.1007/s00259-008-0734-0
    • (2008) Eur. J. Nucl. Med. Mol. Imaging , vol.35 , pp. 1142-1146
    • Beyer, T.1
  • 51
    • 0033046365 scopus 로고    scopus 로고
    • Randoms variance reduction in 3D PET
    • DOI 10.1088/0031-9155/44/4/010, PII S0031915599958049
    • R. D. Badawi, A. P. Miller, D. L. Bailey, and P. K. Mardsen, Randoms variance reduction in 3D PET., Phys. Med. Biol. 44, 941-954 (1999). 10.1088/0031-9155/44/4/010 (Pubitemid 29185384)
    • (1999) Physics in Medicine and Biology , vol.44 , Issue.4 , pp. 941-954
    • Badawi, R.D.1    Miller, M.P.2    Bailey, D.L.3    Marsden, P.K.4
  • 52
    • 0034244929 scopus 로고    scopus 로고
    • New, faster, image-based scatter correction for 3D PET
    • 10.1109/23.873020
    • C. C. Watson, New, faster, image-based scatter correction for 3D PET., IEEE Trans. Nucl. Sci. 47, 1587-1594 (2000). 10.1109/23.873020
    • (2000) IEEE Trans. Nucl. Sci. , vol.47 , pp. 1587-1594
    • Watson, C.C.1
  • 53
    • 0033343646 scopus 로고    scopus 로고
    • Realistic spline-based dynamic heart phantom
    • DOI 10.1109/23.775570
    • W. P. Segars, D. S. Lalush, and B. M. W. Tsui, A realistic spline-based dynamic heart phantom., IEEE Trans. Nucl. Sci. 46, 503-506 (1999). 10.1109/23.775570 (Pubitemid 30504993)
    • (1999) IEEE Transactions on Nuclear Science , vol.46 , Issue.II3 , pp. 503-506
    • Segars, W.P.1    Lalush, D.S.2    Tsui, B.M.W.3
  • 54
    • 13444282105 scopus 로고    scopus 로고
    • The SIMRI project: A versatile and interactive MRI simulator
    • DOI 10.1016/j.jmr.2004.09.027, PII S1090780704003908
    • H. Benoit-Cattin, G. Collewet, B. Belaroussi, H. Saint-Jalmes, and C. Odet, The SIMRI project: a versatile and interactive MRI simulator., J. Magn. Reson. 173, 97-115 (2005). 10.1016/j.jmr.2004.09.027 (Pubitemid 40206422)
    • (2005) Journal of Magnetic Resonance , vol.173 , Issue.1 , pp. 97-115
    • Benoit-Cattin, H.1    Collewet, G.2    Belaroussi, B.3    Saint-Jalmes, H.4    Odet, C.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.