-
1
-
-
78650796319
-
Acute consequences of hypoglycaemia in diabetic patients
-
Halimi S. Acute consequences of hypoglycaemia in diabetic patients. Diabetes Metab. 2010;36 Suppl 3:S75-83.
-
(2010)
Diabetes Metab
, vol.36
, Issue.SUPPL. 3
-
-
Halimi, S.1
-
2
-
-
84861543332
-
Severe hypoglycemia symptoms, antecedent behaviors, immediate consequences and association with glycemia medication usage: Secondary analysis of the ACCORD clinical trial data
-
Bonds DE, Miller ME, Dudl J, Feinglos M, Ismail-Beigi F, Malozowski S, Seaquist E, Simmons DL, Sood A. Severe hypoglycemia symptoms, antecedent behaviors, immediate consequences and association with glycemia medication usage: secondary analysis of the ACCORD clinical trial data. BMC Endocr Disord. 2012;12:5.
-
(2012)
BMC Endocr Disord
, vol.12
, pp. 5
-
-
Bonds, D.E.1
Miller, M.E.2
Dudl, J.3
Feinglos, M.4
Ismail-Beigi, F.5
Malozowski, S.6
Seaquist, E.7
Simmons, D.L.8
Sood, A.9
-
3
-
-
79960959816
-
Effect of intensive glucose lowering treatment on all cause mortality, cardiovascular death, and microvascular events in type 2 diabetes: Metaanalysis of randomised controlled trials
-
Boussageon R, Bejan-Angoulvant T, Saadatian-Elahi M, Lafont S, Bergeonneau C, Kassaï B, Erpeldinger S, Wright JM, Gueyffier F, Cornu C. Effect of intensive glucose lowering treatment on all cause mortality, cardiovascular death, and microvascular events in type 2 diabetes: metaanalysis of randomised controlled trials. BMJ. 2011;343:d4169.
-
(2011)
BMJ
, vol.343
-
-
Boussageon, R.1
Bejan-Angoulvant, T.2
Saadatian-Elahi, M.3
Lafont, S.4
Bergeonneau, C.5
Kassaï, B.6
Erpeldinger, S.7
Wright, J.M.8
Gueyffier, F.9
Cornu, C.10
-
4
-
-
33644819026
-
Comparison of a needle-type and a microdialysis continuous glucose monitor in type 1 diabetic patients
-
DOI 10.2337/diacare.28.12.2871
-
Wentholt IM, Vollebregt MA, Hart AA, Hoekstra JB, DeVries JH. Comparison of a needle-type and a microdialysis continuous glucose monitor in type 1 diabetic patients. Diabetes Care. 2005;28(12):2871-6. (Pubitemid 43942917)
-
(2005)
Diabetes Care
, vol.28
, Issue.12
, pp. 2871-2876
-
-
Wentholt, I.M.1
Vollebregt, M.A.2
Hart, A.A.3
Hoekstra, J.B.4
DeVries, J.H.5
-
5
-
-
4344692198
-
Current problems and potential techniques in in vivo glucose monitoring
-
Wickramasinghe Y, Yang Y, Spencer SA. Current problems and potential techniques in in vivo glucose monitoring. J Fluoresc. 2004;14(5):513-20.
-
(2004)
J Fluoresc
, vol.14
, Issue.5
, pp. 513-520
-
-
Wickramasinghe, Y.1
Yang, Y.2
Spencer, S.A.3
-
6
-
-
0036883638
-
Biosensors for in vivo glucose measurement: Can we cross the experimental stage
-
DOI 10.1016/S0956-5663(02)00099-4, PII S0956566302000994
-
Abel PU, von Woedtke T. Biosensors for in vivo glucose measurement: can we cross the experimental stage. Biosens Bioelectron. 2002;17(11-12):1059-70. (Pubitemid 35232479)
-
(2002)
Biosensors and Bioelectronics
, vol.17
, Issue.11-12
, pp. 1059-1070
-
-
Abel, P.U.1
Von Woedtke, T.2
-
7
-
-
0036021760
-
Continuous glucose monitoring: An overview of today's technologies and their clinical applications
-
Heinemann L, Koschinsky T. Continuous glucose monitoring: an overview of today's technologies and their clinical applications. Int J Clin Pract Suppl. 2002;129:75-9.
-
(2002)
Int J Clin Pract Suppl
, vol.129
, pp. 75-79
-
-
Heinemann, L.1
Koschinsky, T.2
-
8
-
-
14844345011
-
Noninvasive and minimally invasive methods for transdermal glucose monitoring
-
DOI 10.1089/dia.2005.7.174
-
Sieg A, Guy RH, Delgado-Charro MB. Noninvasive and minimally invasive methods for transdermal glucose monitoring. Diabetes Technol Ther. 2005;7(1):174-97. (Pubitemid 40354587)
-
(2005)
Diabetes Technology and Therapeutics
, vol.7
, Issue.1
, pp. 174-197
-
-
Sieg, A.1
Guy, R.H.2
Delgado-Charro, M.B.3
-
9
-
-
0033552348
-
In vivo glucose sensing for diabetes management: Progress towards non-invasive monitoring. Interview by Judy Jones
-
Pickup J, Rolinski O, Birch D. In vivo glucose sensing for diabetes management: progress towards non-invasive monitoring. Interview by Judy Jones. BMJ. 1999;319(7220):1289.
-
(1999)
BMJ
, vol.319
, Issue.7220
, pp. 1289
-
-
Pickup, J.1
Rolinski, O.2
Birch, D.3
-
10
-
-
18044367556
-
Biosensors for real-time in vivo measurements
-
DOI 10.1016/j.bios.2004.12.003, 20th Anniversary of Biosendors and Bioelectronics
-
Wilson GS, Giford R. Biosensors for real-time in vivo measurements. Biosens Bioelectron. 2005;20(12):2388-403. (Pubitemid 40602179)
-
(2005)
Biosensors and Bioelectronics
, vol.20
, Issue.12
, pp. 2388-2403
-
-
Wilson, G.S.1
Gifford, R.2
-
11
-
-
0027474192
-
Screen printed glucose electrodes based on platinised carbon particles and glucose oxidase
-
DOI 10.1016/0003-2670(93)85040-Q
-
Cardosi MF, Birch SW. Screen printed glucose electrodes based on platinised carbon particles and glucose oxidase. Anal Chim Acta. 1993;276:69-74. (Pubitemid 23094266)
-
(1993)
Analytica Chimica Acta
, vol.276
, Issue.1
, pp. 69-74
-
-
Cardosi, M.F.1
Birch, S.W.2
-
12
-
-
84988129719
-
Carbon paste electrode incorporated with cobalt(II) octaethoxyphthalocyanine for the amperometric detection of hydrogen peroxide
-
Mizutani F, Yabuki S, Iijima S. Carbon paste electrode incorporated with cobalt(II) octaethoxyphthalocyanine for the amperometric detection of hydrogen peroxide. Electroanalysis. 1995;7(8):706-9.
-
(1995)
Electroanalysis
, vol.7
, Issue.8
, pp. 706-709
-
-
Mizutani, F.1
Yabuki, S.2
Iijima, S.3
-
13
-
-
0029075404
-
Continuous in vivo monitoring in diabetes: The subcutaneous glucose concentration
-
Fischer U. Continuous in vivo monitoring in diabetes: the subcutaneous glucose concentration. Acta Anaesthesiol Scand Suppl. 1995;104:21-9.
-
(1995)
Acta Anaesthesiol Scand Suppl
, vol.104
, pp. 21-29
-
-
Fischer, U.1
-
14
-
-
0023580011
-
Assessment of subcutaneous glucose concentration: Validation of the wick technique as a reference for implanted electrochemical sensors in normal and diabetic dogs
-
Fischer U, Ertle R, Abel P, Rebrin K, Brunstein E, Hahn von Dorsche H, Freyse EJ. Assessment of subcutaneous glucose concentration: validation of the wick technique as a reference for implanted electrochemical sensors in normal and diabetic dogs. Diabetologia. 1987;30(12):940-5. (Pubitemid 18055852)
-
(1987)
Diabetologia
, vol.30
, Issue.12
, pp. 940-945
-
-
Fischer, U.1
Ertle, R.2
Abel, P.3
Rebrin, K.4
Brunstein, E.5
Hahn, V.D.H.6
Freyse, E.J.7
-
15
-
-
0024541965
-
In vivo molecular sensing in diabetes mellitus: an implantable glucose sensor with direct electron transfer
-
DOI 10.1007/BF00265097
-
Pickup JC, Shaw GW, Claremont DJ. In vivo molecular sensing in diabetes mellitus: an implantable glucose sensor with direct electron transfer. Diabetologia. 1989;32(3):213-7. (Pubitemid 19117104)
-
(1989)
Diabetologia
, vol.32
, Issue.3
, pp. 213-217
-
-
Pickup, J.C.1
Shaw, G.W.2
Claremont, D.J.3
-
17
-
-
0022913659
-
Subcutaneous implantation of a ferrocene-mediated glucose sensor in pigs
-
DOI 10.1007/BF00873223
-
Claremont DJ, Sambrook IE, Penton C, Pickup JC. Subcutaneous implantation of a ferrocene-mediated glucose sensor in pigs. Diabetologia. 1986;29(11):817-21. (Pubitemid 17053721)
-
(1986)
Diabetologia
, vol.29
, Issue.11
, pp. 817-821
-
-
Claremont, D.J.1
Sambrook, I.E.2
Penton, C.3
Pickup, J.C.4
-
18
-
-
0037278431
-
Determination of plasma glucose during rapid glucose excursions with a subcutaneous glucose sensor
-
DOI 10.1089/152091503763816436
-
Steil GM, Rebrin K, Mastrototaro J, Bernaba B, Saad MF. Determination of plasma glucose during rapid glucose excursions with a subcutaneous glucose sensor. Diabetes Technol Ther. 2003;5(1):27-31. (Pubitemid 36506087)
-
(2003)
Diabetes Technology and Therapeutics
, vol.5
, Issue.1
, pp. 27-31
-
-
Steil, G.M.1
Rebrin, K.2
Mastrototaro, J.3
Bernaba, B.4
Saad, M.F.5
-
19
-
-
0026593281
-
Subcutaneous glucose monitoring by means of electrochemical sensors: Fiction or reality
-
Rebrin K, Fischer U, Hahn von Dorsche H, von Woetke T, Abel P, Brunstein E. Subcutaneous glucose monitoring by means of electrochemical sensors: fiction or reality. J Biomed Eng. 1992;14(1):33-40.
-
(1992)
J Biomed Eng
, vol.14
, Issue.1
, pp. 33-40
-
-
Rebrin, K.1
Fischer, U.2
Hahn Von Dorsche, H.3
Von Woetke, T.4
Abel, P.5
Brunstein, E.6
-
20
-
-
3042783097
-
Emerging biomedical sensing technologies and their applications
-
Cote GL, Lec RM, Pishko MV. Emerging biomedical sensing technologies and their applications. IEEE Sens J. 2003;3(3):251-66.
-
(2003)
IEEE Sens J
, vol.3
, Issue.3
, pp. 251-266
-
-
Cote, G.L.1
Lec, R.M.2
Pishko, M.V.3
-
21
-
-
0027411735
-
In vivo glucose monitoring: Sense and sensorbility
-
Pickup JC. In vivo glucose monitoring: sense and sensorbility. Diabetes Care. 1993;16(2):535-9. (Pubitemid 23046648)
-
(1993)
Diabetes Care
, vol.16
, Issue.2
, pp. 535-539
-
-
Pickup, J.C.1
-
22
-
-
0023131817
-
On the way to the automated (blood) glucose regulation in diabetes: The dark past, the grey present and the rosy future
-
XII Congress of the International Diabetes Federation, Madrid, 22-28 September 1985
-
Pfeifer EF. On the way to the automated (blood) glucose regulation in diabetes: the dark past, the grey present and the rosy future. XII Congress of the International Diabetes Federation, Madrid, 22-28 September 1985. Diabetologia. 1987;30(2):51-65.
-
(1987)
Diabetologia
, vol.30
, Issue.2
, pp. 51-65
-
-
Pfeifer, E.F.1
-
23
-
-
0033765196
-
In vitro and in vivo degradation of glucose oxidase enzyme used for an implantable glucose biosensor
-
Valdes TI, Moussy F. In vitro and in vivo degradation of glucose oxidase enzyme used for an implantable glucose biosensor. Diabetes Technol Ther. 2000;2(3):367-76.
-
(2000)
Diabetes Technol Ther
, vol.2
, Issue.3
, pp. 367-376
-
-
Valdes, T.I.1
Moussy, F.2
-
24
-
-
33750623254
-
Biocompatibility of electrochemical glucose sensors implanted in the subcutis of pigs
-
DOI 10.1089/dia.2006.8.463
-
Kvist PH, Iburg T, Bielecki M, Gerstenberg M, Buch-Rasmussen T, Hasselager E, Jensen HE. Biocompatibility of electrochemical glucose sensors implanted in the subcutis of pigs. Diabetes Technol Ther. 2006;8(4):463-75. (Pubitemid 44735466)
-
(2006)
Diabetes Technology and Therapeutics
, vol.8
, Issue.4
, pp. 463-475
-
-
Kvist, P.H.1
Iburg, T.2
Bielecki, M.3
Gerstenberg, M.4
Buch-Rasmussen, T.5
Hasselager, E.6
Jensen, H.E.7
-
25
-
-
0027362745
-
Fibrin(ogen) mediates acute inflammatory responses to biomaterials
-
DOI 10.1084/jem.178.6.2147
-
Tang L, Eaton JW. Fibrin(ogen) mediates acute inflammatory responses to biomaterials. J Exp Med. 1993;178(6):2147-56. (Pubitemid 23344872)
-
(1993)
Journal of Experimental Medicine
, vol.178
, Issue.6
, pp. 2147-2156
-
-
Tang, L.1
Eaton, J.W.2
-
26
-
-
27744589710
-
The endocrine system
-
Kumar V, Abbas AK, Fausto N, eds. Philadelphia: Elsevier Saunders
-
Maitra M, Abbas AK. The endocrine system. In: Kumar V, Abbas AK, Fausto N, eds. Robbins and Cotran pathologic basis of disease. Philadelphia: Elsevier Saunders; 2005, 1189-205.
-
(2005)
Robbins and Cotran Pathologic Basis of Disease
, pp. 1189-1205
-
-
Maitra, M.1
Abbas, A.K.2
-
27
-
-
4344583135
-
Effects of the chemical structure and the surface properties of polymeric biomaterials on their biocompatibility
-
DOI 10.1023/B:PHAM.0000036909.41843.18
-
Wang YX, Robertson JL, Spillman WB Jr, Claus RO. Effects of the chemical structure and the surface properties of polymeric biomaterials on their biocompatibility. Pharm Res. 2004;21(8):1362-73. (Pubitemid 39149650)
-
(2004)
Pharmaceutical Research
, vol.21
, Issue.8
, pp. 1362-1373
-
-
Wang, Y.-X.1
Robertson, J.L.2
Spillman Jr., W.B.3
Claus, R.O.4
-
28
-
-
84871337303
-
Recent advances in continuous glucose monitoring: Biocompatibility of glucose sensors for implantation in subcutis
-
Kvist PH, Jensen HE. Recent advances in continuous glucose monitoring: biocompatibility of glucose sensors for implantation in subcutis. J Diabetes Sci Technol. 2007;1(5):746-52.
-
(2007)
J Diabetes Sci Technol
, vol.1
, Issue.5
, pp. 746-752
-
-
Kvist, P.H.1
Jensen, H.E.2
-
29
-
-
0028929339
-
Inflammatory responses to biomaterials
-
Tang L, Eaton JW. Inflammatory responses to biomaterials. Am J Clin Pathol. 1995;103(4):466-71.
-
(1995)
Am J Clin Pathol
, vol.103
, Issue.4
, pp. 466-471
-
-
Tang, L.1
Eaton, J.W.2
-
30
-
-
84872781187
-
Metabolic biofouling of glucose sensors in vivo: Role of tissue microhemorrhages
-
Klueh U, Liu Z, Feldman B, Henning TP, Cho B, Ouyang T, Kreutzer D. Metabolic biofouling of glucose sensors in vivo: role of tissue microhemorrhages. J Diabetes Sci Technol. 2011;5(3):583-95.
-
(2011)
J Diabetes Sci Technol
, vol.5
, Issue.3
, pp. 583-595
-
-
Klueh, U.1
Liu, Z.2
Feldman, B.3
Henning, T.P.4
Cho, B.5
Ouyang, T.6
Kreutzer, D.7
-
31
-
-
70350345556
-
Surface-modified nanoparticles as a new, versatile, and mechanically robust nonadhesive coating: Suppression of protein adsorption and bacterial adhesion
-
Holmes PF, Currie EP, Thies JC, Van der Mei HC, Busscher HJ, Norde W. Surface-modified nanoparticles as a new, versatile, and mechanically robust nonadhesive coating: Suppression of protein adsorption and bacterial adhesion. J Biomed Mater Res A. 2009;91(3):824-33.
-
(2009)
J Biomed Mater Res A
, vol.91
, Issue.3
, pp. 824-833
-
-
Holmes, P.F.1
Currie, E.P.2
Thies, J.C.3
Van Der Mei, H.C.4
Busscher, H.J.5
Norde, W.6
-
33
-
-
0041386468
-
Constructing thromboresistant surface on biomedical stainless steel via layer-by-layer deposition anticoagulant
-
DOI 10.1016/S0142-9612(03)00363-6
-
Tan Q, Ji J, Barbosa MA, Fonseca C, Shen J. Constructing thromboresistant surface on biomedical stainless steel via layer-by-layer deposition anticoagulant. Biomaterials. 2003;24(25):4699-705. (Pubitemid 37013631)
-
(2003)
Biomaterials
, vol.24
, Issue.25
, pp. 4699-4705
-
-
Tan, Q.1
Ji, J.2
Barbosa, M.A.3
Fonseca, C.4
Shen, J.5
-
34
-
-
84862275093
-
Comparison of modified Chandler, roller pump, and ball valve circulation models for in vitro testing in high blood flow conditions: Application in thrombogenicity testing of different materials for vascular applications
-
Van Oeveren W, Tielliu IF, de Hart J. Comparison of modified Chandler, roller pump, and ball valve circulation models for in vitro testing in high blood flow conditions: application in thrombogenicity testing of different materials for vascular applications. Int J Biomater. 2012;2012:673163.
-
(2012)
Int J Biomater
, vol.2012
, pp. 673163
-
-
Van Oeveren, W.1
Tielliu, I.F.2
De Hart, J.3
|