메뉴 건너뛰기




Volumn , Issue , 2009, Pages 1244-1256

Vascular Access and Complications

Author keywords

Algorithm for catheter related infection; Algorithm for venous thrombosis; Cardiac tamponade; Catheter related venous thrombosis; Complications related to catheter insertion; Externally tunneled catheter; Implantable subcutaneous ports; Vascular access and complications

Indexed keywords


EID: 84890758167     PISSN: None     EISSN: None     Source Type: Book    
DOI: 10.1002/9781444303537.ch83     Document Type: Chapter
Times cited : (1)

References (68)
  • 1
    • 0024595241 scopus 로고
    • The origins of intravenous fl uid therapy
    • Cosnett JE. The origins of intravenous fl uid therapy. Lancet 1989; 333: 768-71.
    • (1989) Lancet , vol.333 , pp. 768-771
    • Cosnett, J.E.1
  • 2
    • 0014202118 scopus 로고
    • The utilization of long nylon catheters for prolonged intravenous infusions
    • Roy R, Wilkinson R, Bayliss C. The utilization of long nylon catheters for prolonged intravenous infusions. Can Med Assoc J 1967; 96: 94-7.
    • (1967) Can Med Assoc J , vol.96 , pp. 94-97
    • Roy, R.1    Wilkinson, R.2    Bayliss, C.3
  • 3
    • 0015611436 scopus 로고
    • A silicone rubber atrial catheter for prolonged parenteral alimentation
    • Broviac JW, Cole JJ, Scribner BH. A silicone rubber atrial catheter for prolonged parenteral alimentation. Surg Gynecol Obstet 1973; 136: 602-6.
    • (1973) Surg Gynecol Obstet , vol.136 , pp. 602-606
    • Broviac, J.W.1    Cole, J.J.2    Scribner, B.H.3
  • 5
    • 0033531178 scopus 로고    scopus 로고
    • The evolving technology of venous access
    • Wenzel RP, Edmond MB. The evolving technology of venous access. N Engl J Med 1999; 340: 48-50.
    • (1999) N Engl J Med , vol.340 , pp. 48-50
    • Wenzel, R.P.1    Edmond, M.B.2
  • 6
    • 0032012460 scopus 로고    scopus 로고
    • Utility and safety of Hickman catheters for venous access after bone marrow transplantation
    • Kumagai T, Sakamaki H, Tanikawa S et al. Utility and safety of Hickman catheters for venous access after bone marrow transplantation. Intern Med 1998; 37: 286-91.
    • (1998) Intern Med , vol.37 , pp. 286-291
    • Kumagai, T.1    Sakamaki, H.2    Tanikawa, S.3
  • 7
    • 10744230129 scopus 로고    scopus 로고
    • Use of totally implantable central venous access ports for highdose chemotherapy and peripheral blood stem cell transplantation: results of a monocentre series of 376 patients
    • Biffi R, Pozzi S, Agazzi A et al. Use of totally implantable central venous access ports for highdose chemotherapy and peripheral blood stem cell transplantation: results of a monocentre series of 376 patients. Ann Oncol 2004; 15: 296-300.
    • (2004) Ann Oncol , vol.15 , pp. 296-300
    • Biffi, R.1    Pozzi, S.2    Agazzi, A.3
  • 8
    • 0034031875 scopus 로고    scopus 로고
    • Multi-purpose silastic dual-lumen central venous catheters for both collection and transplantation of hematopoietic progenitor cells
    • Lazarus HM, Trehan S, Miller R, Fox RM, Creger RJ, Raaf JH. Multi-purpose silastic dual-lumen central venous catheters for both collection and transplantation of hematopoietic progenitor cells. Bone Marrow Transplant 2000; 25: 779-85.
    • (2000) Bone Marrow Transplant , vol.25 , pp. 779-785
    • Lazarus, H.M.1    Trehan, S.2    Miller, R.3    Fox, R.M.4    Creger, R.J.5    Raaf, J.H.6
  • 9
    • 0345732692 scopus 로고    scopus 로고
    • Peripherally inserted central venous catheters for autologous blood progenitor cell transplantation in patients with haematological malignancies
    • Harter C, Ostendorf T, Bach A, Egerer G, Goldschmidt H, Ho AD. Peripherally inserted central venous catheters for autologous blood progenitor cell transplantation in patients with haematological malignancies. Support Care Cancer 2003; 11: 790-4.
    • (2003) Support Care Cancer , vol.11 , pp. 790-794
    • Harter, C.1    Ostendorf, T.2    Bach, A.3    Egerer, G.4    Goldschmidt, H.5    Ho, A.D.6
  • 10
    • 2942568326 scopus 로고    scopus 로고
    • High rate of complications associated with peripherally inserted central venous catheters in patients with solid tumours
    • Cheong K, Perry D, Karapetis C, Koczwara B. High rate of complications associated with peripherally inserted central venous catheters in patients with solid tumours. Intern Med J 2004; 34: 234-8.
    • (2004) Intern Med J , vol.34 , pp. 234-238
    • Cheong, K.1    Perry, D.2    Karapetis, C.3    Koczwara, B.4
  • 11
    • 0029447385 scopus 로고
    • Comparison of the fl ow rates of central venous catheters designed for rapid transfusion in infants and small children
    • Beebe DS, Beck D, Belani KG. Comparison of the fl ow rates of central venous catheters designed for rapid transfusion in infants and small children. Paediatr Anaesthes 1995; 5: 35-9.
    • (1995) Paediatr Anaesthes , vol.5 , pp. 35-39
    • Beebe, D.S.1    Beck, D.2    Belani, K.G.3
  • 13
    • 23744489549 scopus 로고    scopus 로고
    • Risk of catheter-related bloodstream infection with peripherally inserted central venous catheters used in hospitalized patients
    • Safdar N, Maki DG. Risk of catheter-related bloodstream infection with peripherally inserted central venous catheters used in hospitalized patients. Chest 2005; 128: 489-95.
    • (2005) Chest , vol.128 , pp. 489-495
    • Safdar, N.1    Maki, D.G.2
  • 14
    • 0036750094 scopus 로고    scopus 로고
    • Performance of a hybrid central venous catheter utilized for both peripheral blood stem cell harvest and transplant support of patients undergoing autologous peripheral blood stem cell transplantation
    • Restrepo A, Devore P, Encarnacion CE et al. Performance of a hybrid central venous catheter utilized for both peripheral blood stem cell harvest and transplant support of patients undergoing autologous peripheral blood stem cell transplantation. Bone Marrow Transplant 2002; 30: 389-95.
    • (2002) Bone Marrow Transplant , vol.30 , pp. 389-395
    • Restrepo, A.1    Devore, P.2    Encarnacion, C.E.3
  • 15
    • 0029243652 scopus 로고
    • Left internal versus right internal jugular vein access to central venous circulation using the Seldinger technique
    • Muralidhar K. Left internal versus right internal jugular vein access to central venous circulation using the Seldinger technique. J Cardiothorac Vasc Anesth 1995; 9: 115-16.
    • (1995) J Cardiothorac Vasc Anesth , vol.9 , pp. 115-116
    • Muralidhar, K.1
  • 16
    • 0037294081 scopus 로고    scopus 로고
    • Malpositioning of Hickman catheters, left versus right sided attempts
    • Unal AE, Bayar S, Arat M, Ilhan O. Malpositioning of Hickman catheters, left versus right sided attempts. Transfus Apher Sci 2003; 28: 9-12.
    • (2003) Transfus Apher Sci , vol.28 , pp. 9-12
    • Unal, A.E.1    Bayar, S.2    Arat, M.3    Ilhan, O.4
  • 17
    • 0032866834 scopus 로고    scopus 로고
    • Silicone venous access devices positioned with their tips high in the superior vena cava are more likely to malfunction
    • Petersen J, Delaney JH, Brakstad MT, Rowbotham RK, Bagley CM, Jr. Silicone venous access devices positioned with their tips high in the superior vena cava are more likely to malfunction. Am J Surg 1999; 178: 38-41.
    • (1999) Am J Surg , vol.178 , pp. 38-41
    • Petersen, J.1    Delaney, J.H.2    Brakstad, M.T.3    Rowbotham, R.K.4    Bagley Jr., C.M.5
  • 18
    • 34250867431 scopus 로고    scopus 로고
    • Real-time ultrasound-guided catheterisation of the internal jugular vein: a prospective comparison with the landmark technique in critical care patients
    • Karakitsos D, Labropoulos N, De Groot E et al. Real-time ultrasound-guided catheterisation of the internal jugular vein: a prospective comparison with the landmark technique in critical care patients. Crit Care 2006; 10: R162.
    • (2006) Crit Care , vol.10
    • Karakitsos, D.1    Labropoulos, N.2    De Groot, E.3
  • 20
    • 0033857256 scopus 로고    scopus 로고
    • Imageguided central venous catheter placement for apheresis in allogeneic stem cell donors
    • Sadler DJ, McCarthy M, Saliken JC et al. Imageguided central venous catheter placement for apheresis in allogeneic stem cell donors. J Clin Apher 2000; 15: 173-5.
    • (2000) J Clin Apher , vol.15 , pp. 173-175
    • Sadler, D.J.1    McCarthy, M.2    Saliken, J.C.3
  • 21
    • 14544277951 scopus 로고    scopus 로고
    • An anatomic landmark to simplify subclavian vein cannulation: the "deltoid tuberosity"
    • von Goedecke A, Keller C, Moriggl B et al. An anatomic landmark to simplify subclavian vein cannulation: the "deltoid tuberosity". Anesth Analg 2005; 100: 623-8.
    • (2005) Anesth Analg , vol.100 , pp. 623-628
    • von Goedecke, A.1    Keller, C.2    Moriggl, B.3
  • 22
    • 33747607066 scopus 로고    scopus 로고
    • Central venous catheter-related infection in a prospective and observational study of 2,595 catheters
    • Lorente L, Henry C, Martin MM, Jimenez A, Mora ML. Central venous catheter-related infection in a prospective and observational study of 2,595 catheters. Crit Care 2005; 9: R631-5.
    • (2005) Crit Care , vol.9
    • Lorente, L.1    Henry, C.2    Martin, M.M.3    Jimenez, A.4    Mora, M.L.5
  • 23
    • 0027186164 scopus 로고
    • Propofol versus midazolam for monitored sedation: a comparison of intraoperative and recovery parameters
    • Pratila MG, Fischer ME, Alagesan R, Alagesan R, Reinsel RA, Pratilas D. Propofol versus midazolam for monitored sedation: a comparison of intraoperative and recovery parameters. J Clin Anesth 1993; 5: 268-74.
    • (1993) J Clin Anesth , vol.5 , pp. 268-274
    • Pratila, M.G.1    Fischer, M.E.2    Alagesan, R.3    Alagesan, R.4    Reinsel, R.A.5    Pratilas, D.6
  • 24
    • 37249067319 scopus 로고    scopus 로고
    • Prophylactic antibiotics for preventing early central venous catheter Gram positive infections in oncology patients
    • van de Wetering MD, van Woensel JB. Prophylactic antibiotics for preventing early central venous catheter Gram positive infections in oncology patients. Cochrane Database Syst Rev 2007(1): CD003295.
    • (2007) Cochrane Database Syst Rev , Issue.1
    • van de Wetering, M.D.1    van Woensel, J.B.2
  • 25
    • 0031026423 scopus 로고    scopus 로고
    • Percutaneous nonangiographic insertion of Hickman catheters in marrow transplant recipients by anesthesiologists and intensivists
    • Muhm M, Kalhs P, Sunder-Plassmann G, Apsner R, Brugger S, Druml W. Percutaneous nonangiographic insertion of Hickman catheters in marrow transplant recipients by anesthesiologists and intensivists. Anesth Analg 1997; 84: 80-4.
    • (1997) Anesth Analg , vol.84 , pp. 80-84
    • Muhm, M.1    Kalhs, P.2    Sunder-Plassmann, G.3    Apsner, R.4    Brugger, S.5    Druml, W.6
  • 26
    • 0033974729 scopus 로고    scopus 로고
    • How much guidewire is too much? Direct measurement of the distance from subclavian and internal jugular vein access sites to the superior vena cava-atrial junction during central venous catheter placement
    • Andrews RT, Bova DA, Venbrux AC. How much guidewire is too much? Direct measurement of the distance from subclavian and internal jugular vein access sites to the superior vena cava-atrial junction during central venous catheter placement. Crit Care Med 2000; 28: 138-42.
    • (2000) Crit Care Med , vol.28 , pp. 138-142
    • Andrews, R.T.1    Bova, D.A.2    Venbrux, A.C.3
  • 27
    • 0033660173 scopus 로고    scopus 로고
    • Sucking noise and collapse after central venous catheter removal
    • Madden B, Paruchuru P, Kunst H. Sucking noise and collapse after central venous catheter removal. J R Soc Med 2000; 93: 592-3.
    • (2000) J R Soc Med , vol.93 , pp. 592-593
    • Madden, B.1    Paruchuru, P.2    Kunst, H.3
  • 28
    • 0037079397 scopus 로고    scopus 로고
    • Ultrasound guided central venous access
    • Muhm M. Ultrasound guided central venous access. BMJ 2002; 325: 1373-4.
    • (2002) BMJ , vol.325 , pp. 1373-1374
    • Muhm, M.1
  • 29
    • 0043234290 scopus 로고    scopus 로고
    • Ultrasonic locating devices for central venous cannulation: meta-analysis
    • Hind D, Calvert N, McWilliams R et al. Ultrasonic locating devices for central venous cannulation: meta-analysis. BMJ 2003; 327: 361.
    • (2003) BMJ , vol.327 , pp. 361
    • Hind, D.1    Calvert, N.2    McWilliams, R.3
  • 30
    • 0033779171 scopus 로고    scopus 로고
    • Conversion of indwelling chest port catheters to tunneled central venous catheters
    • Brodwater BK, Silber JS, Smith TP et al. Conversion of indwelling chest port catheters to tunneled central venous catheters. J Vasc Interv Radiol 2000; 11: 1137-42.
    • (2000) J Vasc Interv Radiol , vol.11 , pp. 1137-1142
    • Brodwater, B.K.1    Silber, J.S.2    Smith, T.P.3
  • 31
    • 0031893389 scopus 로고    scopus 로고
    • Right atrial thrombi are related to indwelling central venous catheter position: insights into time course and possible mechanism of formation
    • Gilon D, Schechter D, Rein AJ et al. Right atrial thrombi are related to indwelling central venous catheter position: insights into time course and possible mechanism of formation. Am Heart J 1998; 135: 457-62.
    • (1998) Am Heart J , vol.135 , pp. 457-462
    • Gilon, D.1    Schechter, D.2    Rein, A.J.3
  • 32
    • 0037018953 scopus 로고    scopus 로고
    • Chlorhexidine compared with povidone-iodine solution for vascular catheter-site care: a metaanalysis
    • Chaiyakunapruk N, Veenstra DL, Lipsky BA, Saint S. Chlorhexidine compared with povidone-iodine solution for vascular catheter-site care: a metaanalysis. Ann Intern Med 2002; 136: 792-801.
    • (2002) Ann Intern Med , vol.136 , pp. 792-801
    • Chaiyakunapruk, N.1    Veenstra, D.L.2    Lipsky, B.A.3    Saint, S.4
  • 34
    • 33746633900 scopus 로고    scopus 로고
    • Use of vancomycin-containing lock or fl ush solutions for prevention of bloodstream infection associated with central venous access devices: a meta-analysis of prospective, randomized trials
    • Safdar N, Maki DG. Use of vancomycin-containing lock or fl ush solutions for prevention of bloodstream infection associated with central venous access devices: a meta-analysis of prospective, randomized trials. Clin Infect Dis 2006; 43: 474-84.
    • (2006) Clin Infect Dis , vol.43 , pp. 474-484
    • Safdar, N.1    Maki, D.G.2
  • 35
    • 33745485096 scopus 로고    scopus 로고
    • The impact of needleless connector device design on central venous catheter occlusion in children: a prospective, controlled trial
    • Schilling S, Doellman D, Hutchinson N, Jacobs BR. The impact of needleless connector device design on central venous catheter occlusion in children: a prospective, controlled trial. JPEN J Parenter Enteral Nutr 2006; 30: 85-90.
    • (2006) JPEN J Parenter Enteral Nutr , vol.30 , pp. 85-90
    • Schilling, S.1    Doellman, D.2    Hutchinson, N.3    Jacobs, B.R.4
  • 36
    • 0030117209 scopus 로고    scopus 로고
    • Complications associated with the use of central venous access devices
    • Whitman ED. Complications associated with the use of central venous access devices. Curr Probl Surg 1996; 33: 309-78.
    • (1996) Curr Probl Surg , vol.33 , pp. 309-378
    • Whitman, E.D.1
  • 37
    • 0036168422 scopus 로고    scopus 로고
    • Complications of central venous catheters: internal jugular versus subclavian access - a systematic review
    • Ruesch S, Walder B, Tramer MR. Complications of central venous catheters: internal jugular versus subclavian access - a systematic review. Crit Care Med 2002; 30: 454-60.
    • (2002) Crit Care Med , vol.30 , pp. 454-460
    • Ruesch, S.1    Walder, B.2    Tramer, M.R.3
  • 38
    • 33845781545 scopus 로고    scopus 로고
    • Preliminary report of a prospective, randomized trial of underwater seal for spontaneous and iatrogenic pneumothorax
    • Reed MF, Lyons JM, Luchette FA, Neu JA, Howington JA. Preliminary report of a prospective, randomized trial of underwater seal for spontaneous and iatrogenic pneumothorax. J Am Coll Surg 2007; 204: 84-90.
    • (2007) J Am Coll Surg , vol.204 , pp. 84-90
    • Reed, M.F.1    Lyons, J.M.2    Luchette, F.A.3    Neu, J.A.4    Howington, J.A.5
  • 39
    • 0029936064 scopus 로고    scopus 로고
    • The management of pneumothorax with the thoracic vent versus conventional intercostal tube drainage
    • Roggla M, Wagner A, Brunner C, Roggla G. The management of pneumothorax with the thoracic vent versus conventional intercostal tube drainage. Wien Klin Wochenschr 1996; 108: 330-3.
    • (1996) Wien Klin Wochenschr , vol.108 , pp. 330-333
    • Roggla, M.1    Wagner, A.2    Brunner, C.3    Roggla, G.4
  • 40
    • 0030909130 scopus 로고    scopus 로고
    • Complications associated with central venous catheters used for the collection of peripheral blood progenitor cells to support high-dose chemotherapy and autologous stem cell rescue
    • Meisenberg BR, Callaghan M, Sloan C, Sampson L, Miller WE, McMillan R. Complications associated with central venous catheters used for the collection of peripheral blood progenitor cells to support high-dose chemotherapy and autologous stem cell rescue. Support Care Cancer 1997; 5: 223-7.
    • (1997) Support Care Cancer , vol.5 , pp. 223-227
    • Meisenberg, B.R.1    Callaghan, M.2    Sloan, C.3    Sampson, L.4    Miller, W.E.5    McMillan, R.6
  • 41
    • 0035016676 scopus 로고    scopus 로고
    • Evaluation of various maneuvers for prevention of air embolism during central venous catheter placement
    • Wysoki MG, Covey A, Pollak J, Rosenblatt M, Aruny J, Denbow N. Evaluation of various maneuvers for prevention of air embolism during central venous catheter placement. J Vasc Interv Radiol 2001; 12: 764-6.
    • (2001) J Vasc Interv Radiol , vol.12 , pp. 764-766
    • Wysoki, M.G.1    Covey, A.2    Pollak, J.3    Rosenblatt, M.4    Aruny, J.5    Denbow, N.6
  • 42
    • 0033859579 scopus 로고    scopus 로고
    • Safe placement of central venous catheters: where should the tip lie?
    • Fletcher S, Bodenham A. Safe placement of central venous catheters: where should the tip lie? Br J Anaesth 2000; 85: 188-92.
    • (2000) Br J Anaesth , vol.85 , pp. 188-192
    • Fletcher, S.1    Bodenham, A.2
  • 43
    • 2942556571 scopus 로고    scopus 로고
    • Dose-ranging trial with a recombinant urokinase (urokinase alfa) for occluded central venous catheters in oncology patients
    • Deitcher SR, Fraschini G, Himmelfarb J et al. Dose-ranging trial with a recombinant urokinase (urokinase alfa) for occluded central venous catheters in oncology patients. J Vasc Interv Radiol 2004; 15: 575-80.
    • (2004) J Vasc Interv Radiol , vol.15 , pp. 575-580
    • Deitcher, S.R.1    Fraschini, G.2    Himmelfarb, J.3
  • 44
    • 0037316267 scopus 로고    scopus 로고
    • Central venous access device occlusions Part 1. Thrombotic causes and treatment
    • Gorski LA. Central venous access device occlusions. Part 1. Thrombotic causes and treatment. Home Healthc Nurse 2003; 21: 115-23.
    • (2003) Home Healthc Nurse , vol.21 , pp. 115-123
    • Gorski, L.A.1
  • 45
    • 0036137741 scopus 로고    scopus 로고
    • Safety and efficacy of alteplase for restoring function in occluded central venous catheters: results of the cardiovascular thrombolytic to open occluded lines trial
    • Deitcher SR, Fesen MR, Kiproff PM et al. Safety and efficacy of alteplase for restoring function in occluded central venous catheters: results of the cardiovascular thrombolytic to open occluded lines trial. J Clin Oncol 2002; 20: 317-24.
    • (2002) J Clin Oncol , vol.20 , pp. 317-324
    • Deitcher, S.R.1    Fesen, M.R.2    Kiproff, P.M.3
  • 46
    • 0035200601 scopus 로고    scopus 로고
    • Lack of efficacy of twice-weekly urokinase in the prevention of complications associated with Hickman catheters: a multicentre randomised comparison of urokinase versus heparin
    • Solomon B, Moore J, Arthur C, Prince HM. Lack of efficacy of twice-weekly urokinase in the prevention of complications associated with Hickman catheters: a multicentre randomised comparison of urokinase versus heparin. Eur J Cancer 2001; 37: 2379-84.
    • (2001) Eur J Cancer , vol.37 , pp. 2379-2384
    • Solomon, B.1    Moore, J.2    Arthur, C.3    Prince, H.M.4
  • 47
    • 0037645283 scopus 로고    scopus 로고
    • Central venous access device occlusions Part 2. Nonthrombotic causes and treatment
    • Gorski LA. Central venous access device occlusions. Part 2. Nonthrombotic causes and treatment. Home Healthc Nurse 2003; 21: 168-73.
    • (2003) Home Healthc Nurse , vol.21 , pp. 168-173
    • Gorski, L.A.1
  • 48
    • 3843105849 scopus 로고    scopus 로고
    • Pinch-off syndrome: case report and collective review of the literature
    • Mirza B, Vanek VW, Kupensky DT. Pinch-off syndrome: case report and collective review of the literature. Am Surg 2004; 70: 635-44.
    • (2004) Am Surg , vol.70 , pp. 635-644
    • Mirza, B.1    Vanek, V.W.2    Kupensky, D.T.3
  • 49
    • 0036709626 scopus 로고    scopus 로고
    • Emergency percutaneous retrieval of a silicone port catheter fragment in pinch-off syndrome by means of an Amplatz gooseneck snare
    • Dinkel HP, Muhm M, Exadaktylos AK, Hoppe H, Triller J. Emergency percutaneous retrieval of a silicone port catheter fragment in pinch-off syndrome by means of an Amplatz gooseneck snare. Emerg Radiol 2002; 9: 165-8.
    • (2002) Emerg Radiol , vol.9 , pp. 165-168
    • Dinkel, H.P.1    Muhm, M.2    Exadaktylos, A.K.3    Hoppe, H.4    Triller, J.5
  • 50
    • 18444388270 scopus 로고    scopus 로고
    • Infectious complications of central venous catheters increase the risk of catheter-related thrombosis in hematology patients: a prospective study
    • van Rooden CJ, Schippers EF, Barge RM et al. Infectious complications of central venous catheters increase the risk of catheter-related thrombosis in hematology patients: a prospective study. J Clin Oncol 2005; 23: 2655-60.
    • (2005) J Clin Oncol , vol.23 , pp. 2655-2660
    • van Rooden, C.J.1    Schippers, E.F.2    Barge, R.M.3
  • 51
    • 34447650408 scopus 로고    scopus 로고
    • A pilot study of central venous catheter survival in cancer patients using low molecular weight heparin (dalteparin) and warfarin without catheter removal for the treatment of upper extremity deep vein thrombosis (the catheter study)
    • Kovacs MJ, Kahn SR, Rodger M et al. A pilot study of central venous catheter survival in cancer patients using low molecular weight heparin (dalteparin) and warfarin without catheter removal for the treatment of upper extremity deep vein thrombosis (the catheter study). J Thromb Haemost 2007; 5: 1650-3.
    • (2007) J Thromb Haemost , vol.5 , pp. 1650-1653
    • Kovacs, M.J.1    Kahn, S.R.2    Rodger, M.3
  • 52
    • 2342437469 scopus 로고    scopus 로고
    • Factor V Leiden and G20210A prothrombin mutation and the risk of subclavian vein thrombosis in patients with breast cancer and a central venous catheter
    • Mandala M, Curigliano G, Bucciarelli P et al. Factor V Leiden and G20210A prothrombin mutation and the risk of subclavian vein thrombosis in patients with breast cancer and a central venous catheter. Ann Oncol 2004; 15: 590-3.
    • (2004) Ann Oncol , vol.15 , pp. 590-593
    • Mandala, M.1    Curigliano, G.2    Bucciarelli, P.3
  • 53
    • 17144409931 scopus 로고    scopus 로고
    • Risk factors for mortality in patients with upper extremity and internal jugular deep venous thrombosis
    • Hingorani A, Ascher E, Markevich N et al. Risk factors for mortality in patients with upper extremity and internal jugular deep venous thrombosis. J Vasc Surg 2005; 41: 476-8.
    • (2005) J Vasc Surg , vol.41 , pp. 476-478
    • Hingorani, A.1    Ascher, E.2    Markevich, N.3
  • 54
    • 4644228314 scopus 로고    scopus 로고
    • Upper-extremity deep vein thrombosis: a prospective registry of 592 patients
    • Joffe HV, Kucher N, Tapson VF, Goldhaber SZ. Upper-extremity deep vein thrombosis: a prospective registry of 592 patients. Circulation 2004; 110: 1605-11.
    • (2004) Circulation , vol.110 , pp. 1605-1611
    • Joffe, H.V.1    Kucher, N.2    Tapson, V.F.3    Goldhaber, S.Z.4
  • 55
    • 0037775584 scopus 로고    scopus 로고
    • Lowmolecular- weight heparin versus a coumarin for the prevention of recurrent venous thromboembolism in patients with cancer
    • Lee AY, Levine MN, Baker RI et al. Lowmolecular- weight heparin versus a coumarin for the prevention of recurrent venous thromboembolism in patients with cancer. N Engl J Med 2003; 349: 146-53.
    • (2003) N Engl J Med , vol.349 , pp. 146-153
    • Lee, A.Y.1    Levine, M.N.2    Baker, R.I.3
  • 56
    • 30444457926 scopus 로고    scopus 로고
    • Prophylaxis of central venous catheter-related thrombosis with minidose warfarin in patients treated with high-dose chemotherapy and peripheral-blood stem-cell transplantation: retrospective analysis of 228 cancer patients
    • Magagnoli M, Masci G, Castagna L et al. Prophylaxis of central venous catheter-related thrombosis with minidose warfarin in patients treated with high-dose chemotherapy and peripheral-blood stem-cell transplantation: retrospective analysis of 228 cancer patients. Am J Hematol 2006; 81: 1-4.
    • (2006) Am J Hematol , vol.81 , pp. 1-4
    • Magagnoli, M.1    Masci, G.2    Castagna, L.3
  • 57
    • 31444432756 scopus 로고    scopus 로고
    • Primary thromboprophylaxis for cancer patients with central venous catheters - a reappraisal of the evidence
    • Cunningham MS, White B, Hollywood D, O'Donnell J. Primary thromboprophylaxis for cancer patients with central venous catheters - a reappraisal of the evidence. Br J Cancer 2006; 94: 189-94.
    • (2006) Br J Cancer , vol.94 , pp. 189-194
    • Cunningham, M.S.1    White, B.2    Hollywood, D.3    O'Donnell, J.4
  • 58
    • 23044457912 scopus 로고    scopus 로고
    • Catheter-associated thrombosis: thromboprophylaxis or not?
    • Levine M, Kakkar AK. Catheter-associated thrombosis: thromboprophylaxis or not? J Clin Oncol 2005; 23: 4006-8.
    • (2005) J Clin Oncol , vol.23 , pp. 4006-4008
    • Levine, M.1    Kakkar, A.K.2
  • 59
    • 14844365297 scopus 로고    scopus 로고
    • Meta-analysis: methods for diagnosing intravascular devicerelated bloodstream infection
    • Safdar N, Fine JP, Maki DG. Meta-analysis: methods for diagnosing intravascular devicerelated bloodstream infection. Ann Intern Med 2005; 142: 451-66.
    • (2005) Ann Intern Med , vol.142 , pp. 451-466
    • Safdar, N.1    Fine, J.P.2    Maki, D.G.3
  • 60
    • 33748174254 scopus 로고    scopus 로고
    • The risk of bloodstream infection in adults with different intravascular devices: a systematic review of 200 published prospective studies
    • Maki DG, Kluger DM, Crnich CJ. The risk of bloodstream infection in adults with different intravascular devices: a systematic review of 200 published prospective studies. Mayo Clin Proc 2006; 81: 1159-71.
    • (2006) Mayo Clin Proc , vol.81 , pp. 1159-1171
    • Maki, D.G.1    Kluger, D.M.2    Crnich, C.J.3
  • 61
    • 0034103063 scopus 로고    scopus 로고
    • Optimal management of central venous catheter-related infections - what is the evidence?
    • Oppenheim BA. Optimal management of central venous catheter-related infections - what is the evidence? J Infect 2000; 40: 26-30.
    • (2000) J Infect , vol.40 , pp. 26-30
    • Oppenheim, B.A.1
  • 62
    • 3543133717 scopus 로고    scopus 로고
    • Catheter-related bloodstream infection in adult haematology patients: catheter removal practice and outcome
    • Coyle VM, McMullan R, Morris TC, Rooney PJ, Hedderwick S. Catheter-related bloodstream infection in adult haematology patients: catheter removal practice and outcome. J Hosp Infect 2004; 57: 325-31.
    • (2004) J Hosp Infect , vol.57 , pp. 325-331
    • Coyle, V.M.1    McMullan, R.2    Morris, T.C.3    Rooney, P.J.4    Hedderwick, S.5
  • 63
    • 22744432815 scopus 로고    scopus 로고
    • Comparison of antimicrobial impregnation with tunneling of long-term central venous catheters: a randomized controlled trial
    • Darouiche RO, Berger DH, Khardori N et al. Comparison of antimicrobial impregnation with tunneling of long-term central venous catheters: a randomized controlled trial. Ann Surg 2005; 242: 193-200.
    • (2005) Ann Surg , vol.242 , pp. 193-200
    • Darouiche, R.O.1    Berger, D.H.2    Khardori, N.3
  • 64
    • 0037636500 scopus 로고    scopus 로고
    • Safe removal of longterm cuffed Hickman-type catheters
    • Galloway S, Bodenham A. Safe removal of longterm cuffed Hickman-type catheters. Hosp Med 2003; 64: 20-3.
    • (2003) Hosp Med , vol.64 , pp. 20-23
    • Galloway, S.1    Bodenham, A.2
  • 65
    • 0022352767 scopus 로고
    • An improved technique for the removal of long term implantable central venous lines
    • Reed WP, Newman KA, Tenney JH. An improved technique for the removal of long term implantable central venous lines. Surg Gynecol Obstet 1985; 161: 479-80.
    • (1985) Surg Gynecol Obstet , vol.161 , pp. 479-480
    • Reed, W.P.1    Newman, K.A.2    Tenney, J.H.3
  • 66
    • 0034996482 scopus 로고    scopus 로고
    • Outcome of polyester cuff retention following traction removal of tunneled central venous catheters
    • Kohli MD, Trerotola SO, Namyslowski J et al. Outcome of polyester cuff retention following traction removal of tunneled central venous catheters. Radiology 2001; 219: 651-4.
    • (2001) Radiology , vol.219 , pp. 651-654
    • Kohli, M.D.1    Trerotola, S.O.2    Namyslowski, J.3
  • 67
    • 0028239432 scopus 로고
    • Retained Hickman catheter cuff as an infection source following allogeneic bone marrow transplant
    • Ruppel LJ, Brown RA, Borson RA, Whitman ED. Retained Hickman catheter cuff as an infection source following allogeneic bone marrow transplant. Bone Marrow Transplant 1994; 14: 169-71.
    • (1994) Bone Marrow Transplant , vol.14 , pp. 169-171
    • Ruppel, L.J.1    Brown, R.A.2    Borson, R.A.3    Whitman, E.D.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.