메뉴 건너뛰기




Volumn 30, Issue 6, 2002, Pages 389-395

Performance of a hybrid central venous catheter utilized for both peripheral blood stem cell harvest and transplant support of patients undergoing autologous peripheral blood stem cell transplantation

Author keywords

Catheters; Hematopoietic stem cell transplantation; Indwelling; Infection

Indexed keywords

ADULT; AGED; ARTICLE; AUTOTRANSPLANTATION; BLOOD CLOTTING; CENTRAL VENOUS CATHETERIZATION; CLINICAL TRIAL; FEMALE; FEVER; HUMAN; INFECTION; INSTRUMENTATION; LEUKAPHERESIS; MALE; MIDDLE AGED; NEOPLASM; PERIPHERAL BLOOD STEM CELL TRANSPLANTATION; PROSPECTIVE STUDY; CATHETER INFECTION; CENTRAL VENOUS CATHETER; CONTROLLED STUDY; DATA ANALYSIS; DEVICE; DEVICE REMOVAL; INFECTIOUS COMPLICATION; MAJOR CLINICAL STUDY; PERIPHERAL BLOOD STEM CELL; PRIORITY JOURNAL; STEM CELL TRANSPLANTATION; VEIN OCCLUSION;

EID: 0036750094     PISSN: 02683369     EISSN: None     Source Type: Journal    
DOI: 10.1038/sj.bmt.1703647     Document Type: Article
Times cited : (9)

References (15)
  • 1
    • 0034031875 scopus 로고    scopus 로고
    • Multi-purpose silastic dual-lumen central venous catheter for both collection and transplantation of hematopoietic progenitor cells
    • Lazarus HM, Trehan S, Miler R et al. Multi-purpose silastic dual-lumen central venous catheter for both collection and transplantation of hematopoietic progenitor cells. Bone Marrow Transplant 2000; 25: 779-785.
    • (2000) Bone Marrow Transplant , vol.25 , pp. 779-785
    • Lazarus, H.M.1    Trehan, S.2    Miler, R.3
  • 2
    • 0030909130 scopus 로고    scopus 로고
    • Complications associated with central venous catheters used for the collection of peripheral blood progenitor cells to support high dose chemotherapy and autologous stem cell rescue
    • Meisenberg BR, Callaghan M, Sloan C et al. Complications associated with central venous catheters used for the collection of peripheral blood progenitor cells to support high dose chemotherapy and autologous stem cell rescue. Support Care Cancer 1997; 5: 223-227.
    • (1997) Support Care Cancer , vol.5 , pp. 223-227
    • Meisenberg, B.R.1    Callaghan, M.2    Sloan, C.3
  • 3
    • 4243355048 scopus 로고    scopus 로고
    • The Neostar catheter: Improved venous access for high dose chemotherapy and pheresis
    • (Abstr. 1766)
    • Cera SM, Carpenter T, Frenette G, White RL. The Neostar catheter: improved venous access for high dose chemotherapy and pheresis. J Clin Oncol 2001; 20 (Suppl. 2): 5b (Abstr. 1766).
    • (2001) J. Clin. Oncol , vol.20 , pp. 5b
    • Cera, S.M.1    Carpenter, T.2    Frenette, G.3    White, R.L.4
  • 4
    • 0030183205 scopus 로고    scopus 로고
    • Guideline for prevention of intravascular-device-related infections
    • Pearson ML. Guideline for prevention of intravascular-device-related infections. Infect Control Hosp Epidemiol 1996; 17: 438-473.
    • (1996) Infect Control Hosp. Epidemiol , vol.17 , pp. 438-473
    • Pearson, M.L.1
  • 5
    • 0030277867 scopus 로고    scopus 로고
    • Surveillance for infections associated with vascular catheters
    • Sherertz RJ. Surveillance for infections associated with vascular catheters. Infect Control Hosp Epidemiol 1996; 17: 746-752.
    • (1996) Infect Control Hosp. Epidemiol , vol.17 , pp. 746-752
    • Sherertz, R.J.1
  • 6
    • 0034502235 scopus 로고    scopus 로고
    • Indications and complications of intravenous devices for chemotherapy
    • Freytes CO. Indications and complications of intravenous devices for chemotherapy. Curr Opin Oncol 2000; 12: 303-1307.
    • (2000) Curr. Opin. Oncol , vol.12 , pp. 303-1307
    • Freytes, C.O.1
  • 7
    • 0028834131 scopus 로고
    • Complications of indwelling venous access devices in cancer patients
    • Eastridge BJ, Lefor AT. Complications of indwelling venous access devices in cancer patients. J Clin Oncol 1995; 13: 233-238.
    • (1995) J. Clin. Oncol , vol.13 , pp. 233-238
    • Eastridge, B.J.1    Lefor, A.T.2
  • 8
    • 0031915412 scopus 로고    scopus 로고
    • Vascular access problems revisited: The Multinational Association of Supportive Care in Cancer (MASCC) experience
    • Freytes CO. Vascular access problems revisited: The Multinational Association of Supportive Care in Cancer (MASCC) experience. Support Care Cancer 1998; 6: 13-19.
    • (1998) Support Care Cancer , vol.6 , pp. 13-19
    • Freytes, C.O.1
  • 9
    • 0028989194 scopus 로고
    • Vancomycin-resistant Enterococcus faecium bacteremia: Risk factors for infection
    • Edmond MB, Ober JF, Weinbaum DL et al. Vancomycin-resistant Enterococcus faecium bacteremia: risk factors for infection. Clin Infect Dis 1995; 20: 1126-1133.
    • (1995) Clin. Infect Dis , vol.20 , pp. 1126-1133
    • Edmond, M.B.1    Ober, J.F.2    Weinbaum, D.L.3
  • 10
    • 0029587645 scopus 로고
    • Increased incidence of central venous catheter-related infections in bone marrow transplant patients
    • Keung YK, Watkins K, Chen SC et al. Increased incidence of central venous catheter-related infections in bone marrow transplant patients. Am J Clin Oncol 1995; 18: 469-474.
    • (1995) Am. J. Clin. Oncol , vol.18 , pp. 469-474
    • Keung, Y.K.1    Watkins, K.2    Chen, S.C.3
  • 11
    • 0025793743 scopus 로고
    • Complications of indwelling central venous catheters in bone marrow transplant recipients
    • Moosa HH, Julian TB, Rosenfeld CS et al. Complications of indwelling central venous catheters in bone marrow transplant recipients. Surg Gynecol Obstet 1991; 172: 275-279.
    • (1991) Surg. Gynecol. Obstet , vol.172 , pp. 275-279
    • Moosa, H.H.1    Julian, T.B.2    Rosenfeld, C.S.3
  • 12
    • 0028948114 scopus 로고
    • Risk factors for infection of adult patients with cancer who have tunneled central venous catheters
    • Howell PB, Walters PE, Donnowitz GR et al. Risk factors for infection of adult patients with cancer who have tunneled central venous catheters. Cancer 1995; 75: 1367-1375.
    • (1995) Cancer , vol.75 , pp. 1367-1375
    • Howell, P.B.1    Walters, P.E.2    Donnowitz, G.R.3
  • 13
    • 0025095462 scopus 로고
    • Increased infection rate in double-lumen versus single lumen Hickman catheters in cancer patients
    • Early TF, Gregory RT, Wheeler JR et al. Increased infection rate in double-lumen versus single lumen Hickman catheters in cancer patients. South Med J 1990; 83: 34-36.
    • (1990) South Med. J , vol.83 , pp. 34-36
    • Early, T.F.1    Gregory, R.T.2    Wheeler, J.R.3
  • 14
    • 0026071974 scopus 로고
    • Thrombotic complications of silicone rubber catheters during autologous marrow and peripheral stem cell transplantation: Prospective comparison of Hickman and Groshong catheters
    • Haire WD, Lieberman RP, Lund GB et al. Thrombotic complications of silicone rubber catheters during autologous marrow and peripheral stem cell transplantation: prospective comparison of Hickman and Groshong catheters. Bone Marrow Transplant 1991; 7: 57-59.
    • (1991) Bone Marrow Transplant , vol.7 , pp. 57-59
    • Haire, W.D.1    Lieberman, R.P.2    Lund, G.B.3
  • 15
    • 0025979091 scopus 로고
    • Catheter-related thrombosis in patients with refractory lymphoma undergoing autologous stem cell transplantation
    • Conlan MG, Haire WD, Lieberman RP et al. Catheter-related thrombosis in patients with refractory lymphoma undergoing autologous stem cell transplantation. Bone Marrow Transplant 1991; 7: 235-240.
    • (1991) Bone Marrow Transplant , vol.7 , pp. 235-240
    • Conlan, M.G.1    Haire, W.D.2    Lieberman, R.P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.