메뉴 건너뛰기




Volumn 70, Issue 7, 2004, Pages 635-644

Pinch-off syndrome: Case report and collective review of the literature

Author keywords

[No Author keywords available]

Indexed keywords

AGED; CASE REPORT; CENTRAL VENOUS CATHETERIZATION; EMBOLISM; EQUIPMENT; FEMALE; HUMAN; INDWELLING CATHETER; MIDDLE AGED; REVIEW; SUBCLAVIAN VEIN; SYNDROME; TIME;

EID: 3843105849     PISSN: 00031348     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Conference Paper
Times cited : (118)

References (36)
  • 1
    • 0000978545 scopus 로고
    • Accidental passage of a polyethylene catheter from cubital vein to right atrium
    • Turner DD, Sommers SC. Accidental passage of a polyethylene catheter from cubital vein to right atrium. N Engl J Med 1954;251:744-745
    • (1954) N Engl J Med , vol.251 , pp. 744-745
    • Turner, D.D.1    Sommers, S.C.2
  • 3
    • 0017836814 scopus 로고
    • Evaluation of current techniques for nonsurgical removal of intravascular iatrogenic foreign bodies
    • Fisher RG, Ferreyro R. Evaluation of current techniques for nonsurgical removal of intravascular iatrogenic foreign bodies. Am J Roentgenol 1978;130:541-548 (Pubitemid 8296385)
    • (1978) American Journal of Roentgenology , vol.130 , Issue.3 , pp. 541-548
    • Fisher, R.G.1    Ferreyro, R.2
  • 4
    • 0021705456 scopus 로고
    • The "pinch-off" sign: A warning of impending problems with permanent subclavian catheters
    • Aitken DR, Minton JP. The "pinch-off" sign: a warning of impending problems with permanent subclavian catheters. Am J Surg 1984;148:633-636
    • (1984) Am J Surg , vol.148 , pp. 633-636
    • Aitken, D.R.1    Minton, J.P.2
  • 7
    • 0027670676 scopus 로고
    • Central venous catheter "pinch-off" and fracture: A review of two under-recognized complications
    • Nace CS, Ingle RJ. Central venous catheter "pinch-off" and fracture: a review of two under-recognized complications. Oncol Nurs Forum 1993;20:1227-1236
    • (1993) Oncol Nurs Forum , vol.20 , pp. 1227-1236
    • Nace, C.S.1    Ingle, R.J.2
  • 8
    • 0029090747 scopus 로고
    • The 'pinch-off phenomenon': A radiological symptom for potential fracture of an implanted permanent subclavian catheter system
    • Schlangen JT, Debets JMH, Wils JA. The 'pinch-off phenomenon': a radiological symptom for potential fracture of an implanted permanent subclavian catheter system. Euro J Radiology 1995;20:112-113
    • (1995) Euro J Radiology , vol.20 , pp. 112-113
    • Schlangen, J.T.1    Debets, J.M.H.2    Wils, J.A.3
  • 9
    • 0029355389 scopus 로고    scopus 로고
    • Rare complications of vascular access devices
    • Ingle RJ. Rare complications of vascular access devices. Semin Oncol Nursing 1996;11:184-193
    • (1996) Semin Oncol Nursing , vol.11 , pp. 184-193
    • Ingle, R.J.1
  • 10
    • 0025887294 scopus 로고
    • Indwelling subclavian catheters and a visit with the "pinched-off sign."
    • Lafreniere R. Indwelling subclavian catheters and a visit with the "pinched-off sign." J Surg Oncol 1991;47:261-264
    • (1991) J Surg Oncol , vol.47 , pp. 261-264
    • Lafreniere, R.1
  • 11
    • 0032426124 scopus 로고    scopus 로고
    • Spontaneous fracture and embolization of a central venous catheter: Prevention and early detection
    • DOI 10.1016/S0936-6555(98)80047-2
    • Coles CE, Whitear WP, LeVay JH. Spontaneous fracture and embolization of a central venous catheter: Prevention and early detection. Clin Oncol 1998;10:412-414 (Pubitemid 29015253)
    • (1998) Clinical Oncology , vol.10 , Issue.6 , pp. 412-414
    • Coles, C.E.1    Whitear, W.P.2    Le Vay, J.H.3
  • 13
    • 0028855447 scopus 로고
    • Case report: Central venous catheter fracture due to compression between the clavicle and first rib
    • Ramsden WH, Cohen AT, Blanshard KS. Case report: central venous catheter fracture due to compression between the clavicle and first rib. J Clin Radiol 1995;50:59-60.
    • (1995) J Clin Radiol , vol.50 , pp. 59-60
    • Ramsden, W.H.1    Cohen, A.T.2    Blanshard, K.S.3
  • 15
    • 0023223019 scopus 로고
    • Spontaneous intravenous catheter fracture and embolization from an implanted venous access port and analysis by scanning electron microscopy
    • DOI 10.1002/1097-0142(19870715)60:2<270::AID-CNCR2820600226>3.0. CO;2-S
    • Prager D, Hertzberg RW. Spontaneous intravenous catheter fracture and embolization from an implanted venous access port and analysis by scanning electron microscopy. Cancer 1987;60:270-273 (Pubitemid 17092269)
    • (1987) Cancer , vol.60 , Issue.2 , pp. 270-273
    • Prager, D.1    Hertzberg, R.W.2
  • 16
    • 0022652550 scopus 로고
    • Fifty-five patient years' experience with totally implanted system for intravenous chemotherapy
    • DOI 10.1002/1097-0142(19860315)57:6<1124::AID-CNCR2820570611>3.0. CO;2-D
    • Brincker H, Seater G. Fifty-five patient years' experience with a totally implanted system for intravenous chemotherapy. Cancer 1986;57:1124-1129 (Pubitemid 16166221)
    • (1986) Cancer , vol.57 , Issue.6 , pp. 1124-1129
    • Brincker, H.1    Saeter, G.2
  • 17
    • 0023387735 scopus 로고
    • Spontaneous fracture of the catheter of totally implantable venous port: Case report of a rare complication
    • Noyen J, Hoorntje J, de Langen Z, et al. Spontaneous fracture of the catheter of totally implantable venous port: case report of a rare complication. J Clin Oncol 1987;5:1295-1299
    • (1987) J Clin Oncol , vol.5 , pp. 1295-1299
    • Noyen, J.1    Hoorntje, J.2    De Langen, Z.3
  • 19
  • 20
    • 0024600693 scopus 로고
    • Catheter embolization from implanted venous access devices: Case reports
    • Carr ME. Catheter embolization from implanted venous access devices: case reports. Angiology 1989;40:319-323
    • (1989) Angiology , vol.40 , pp. 319-323
    • Carr, M.E.1
  • 21
    • 0024581666 scopus 로고
    • In situ breakage of totally implanted venous access system
    • Kirvela O, Satokati K. In situ breakage of totally implanted venous access system. JPEN 1989;13:99-101.
    • (1989) JPEN , vol.13 , pp. 99-101
    • Kirvela, O.1    Satokati, K.2
  • 22
    • 0025990480 scopus 로고
    • Cytostatic extravasation: A serious complication of long-term venous access
    • Bach F, Videbaek C, Holst-Christensen J, et al. Cytostatic extravasation: a serious complication of long-term venous access. Cancer 1991;68:538-539
    • (1991) Cancer , vol.68 , pp. 538-539
    • Bach, F.1    Videbaek, C.2    Holst-Christensen, J.3
  • 23
    • 0026502917 scopus 로고
    • Spontaneous partial fracture of the catheter of totally implantable subcutaneous port
    • Inoue Y, Nezu R, Nakai S, et al. Spontaneous partial fracture of the catheter of totally implantable subcutaneous port. JPEN 1992;16:75-77
    • (1992) JPEN , vol.16 , pp. 75-77
    • Inoue, Y.1    Nezu, R.2    Nakai, S.3
  • 24
    • 0027715867 scopus 로고
    • Catheter fracture: A complication in venous access devices
    • McMenamin E. Catheter fracture: a complication in venous access devices. Cancer Nurs 1993;16:464-467 (Pubitemid 24013327)
    • (1993) Cancer Nursing , vol.16 , Issue.6 , pp. 464-467
    • McMenamin, E.M.1
  • 25
    • 0029133059 scopus 로고
    • Spontaneous fracture of implanted central venous catheters in cancer patients: Report of two cases and retrospective analysis of the 'pinch-off sign' as a risk factor
    • Punt CJA, Strijk S, van der Hoeven JJM, et al. Spontaneous fracture of implanted central venous catheters in cancer patients: report of two cases and retrospective analysis of the 'pinch-off sign' as a risk factor. Anticancer Drugs 1995;6:594-598
    • (1995) Anticancer Drugs , vol.6 , pp. 594-598
    • Punt, C.J.A.1    Strijk, S.2    Van Der Hoeven, J.J.M.3
  • 26
    • 0029949637 scopus 로고    scopus 로고
    • Catheter fracture: A rare complication of totally implantable subclavian venous access devices
    • DOI 10.1002/(SICI)1096-9098(199607)62:3<222::AID-JSO14>3.0.CO;2-8
    • Klotz HP, Schopke W, Kohler A, et al. Catheter fracture: a rare complication of totally implantable subclavian venous access devices. J Surg Oncol 1996;62:222-225 (Pubitemid 26231495)
    • (1996) Journal of Surgical Oncology , vol.62 , Issue.3 , pp. 222-225
    • Klotz, H.P.1    Schopke, W.2    Kohler, A.3    Pestalozzi, B.4    Largiader, F.5
  • 27
    • 0031823191 scopus 로고    scopus 로고
    • Spontaneous leak and transection of permanent subclavian catheters
    • DOI 10.1002/(SICI)1096-9098(199807)68:3<166::AID-JSO6>3.0.CO;2-3
    • Koller M, Papa MZ, Zweig A, et al. Spontaneous leak and transection of permanent subclavian catheters. J Surg Oncol 1998;68:166-168 (Pubitemid 28359614)
    • (1998) Journal of Surgical Oncology , vol.68 , Issue.3 , pp. 166-168
    • Koller, M.1    Papa, M.Z.2    Zweig, A.3    Ben-Ari, G.4
  • 28
    • 0032427703 scopus 로고    scopus 로고
    • Catheter fracture and embolization from totally implanted venous access ports: Case reports
    • Vadlamani P, Dawn B, Perry MC. Catheter fracture and embolization from totally implanted venous access ports: case reports. Angiology 1998;49:1013-1016 (Pubitemid 29005672)
    • (1998) Angiology , vol.49 , Issue.12 , pp. 1013-1016
    • Vadlamani, P.1    Dawn, B.2    Perry, M.C.3
  • 29
    • 0031826109 scopus 로고    scopus 로고
    • Costoclavicular pinching a complication of long-term central venous catheters
    • Nostdahl T, Waagsbo NA. Costoclavicular pinching a complication of long-term central venous catheters. Acta Anaesthesiol Scand 1998;42:872-875
    • (1998) Acta Anaesthesiol Scand , vol.42 , pp. 872-875
    • Nostdahl, T.1    Waagsbo, N.A.2
  • 30
    • 0031745215 scopus 로고    scopus 로고
    • Intravascular disruption of central venous ports
    • DOI 10.1016/S0261-5614(98)80312-9
    • Zieren J, Thul P, Romaniuk P, et al. Intravascular disruption of central venous ports. Clin Nutr 1998;17:89-91. (Pubitemid 28230847)
    • (1998) Clinical Nutrition , vol.17 , Issue.2 , pp. 89-91
    • Zieren, J.1    Thul, P.2    Romaniuk, P.3    Muller, J.M.4
  • 31
    • 0033022230 scopus 로고    scopus 로고
    • Nonsurgical transvenous retrieval of fractured implantable central venous access device
    • Huang HC, Chen WJ, Ho YL, et al. Nonsurgical transvenous retrieval of fractured implantable central venous access device. J Formos Med Assoc 1999;98:265-270
    • (1999) J Formos Med Assoc , vol.98 , pp. 265-270
    • Huang, H.C.1    Chen, W.J.2    Ho, Y.L.3
  • 32
    • 0033231282 scopus 로고    scopus 로고
    • Le syndrome de la pince costoclaviculaire: Principale cause d'embolie de catheter
    • Ouaknine-Orlando B, Desruennes E, Cosset MF, et al. Le syndrome de la pince costoclaviculaire: principale cause d'embolie de catheter. Ann Fr Anesth Reanim 1999;18:949-955
    • (1999) Ann Fr Anesth Reanim , vol.18 , pp. 949-955
    • Ouaknine-Orlando, B.1    Desruennes, E.2    Cosset, M.F.3
  • 33
    • 0002084472 scopus 로고    scopus 로고
    • Catheter rupture and distal embolisation: A rare complication of central venous ports
    • Biffi R, Pozzi S, Orsi F, et al. Catheter rupture and distal embolisation: a rare complication of central venous ports. J Vasc Access 2000;1:19-22.
    • (2000) J Vasc Access , vol.1 , pp. 19-22
    • Biffi, R.1    Pozzi, S.2    Orsi, F.3
  • 34
    • 0034063661 scopus 로고    scopus 로고
    • Catheter fracture and cardiac migration: A rare complication of totally implantable venous devices
    • DOI 10.1002/(SICI)1096-9098(200003)73:3<172::AID-JSO11>3.0.CO;2-Z
    • di Carlo I, Fisichella P, Russello D, et al. Catheter fracture and cardiac migration: a rare complication of totally implantable venous devices. J Surg Oncol 2000;73:172-173 (Pubitemid 30174212)
    • (2000) Journal of Surgical Oncology , vol.73 , Issue.3 , pp. 172-173
    • Di Carlo, I.1    Fisichella, P.2    Russello, D.3    Puleo, S.4    Latteri, F.5
  • 35
    • 0347711976 scopus 로고    scopus 로고
    • A scanning electron microscopy analysis of a spontaneous hemodialysis catheter fracture
    • Weijmer MC, Kars SM, ter Wee PM. A scanning electron microscopy analysis of a spontaneous hemodialysis catheter fracture. Am J Kidney Dis 2001;38:858-861 (Pubitemid 32927912)
    • (2001) American Journal of Kidney Diseases , vol.38 , Issue.4 , pp. 858-861
    • Weijmer, M.C.1    Kars, S.M.2    Ter Wee, P.M.3
  • 36
    • 0034023398 scopus 로고    scopus 로고
    • Catheter fracture - An underrecognized and serious condition in haemodialysis
    • Verhage AH, van Bommel EF. Catheter fracture - an underrecognized and serious condition in haemodialysis. Nephrol Dial Transplant 2000;15:901-903
    • (2000) Nephrol Dial Transplant , vol.15 , pp. 901-903
    • Verhage, A.H.1    Van Bommel, E.F.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.