메뉴 건너뛰기




Volumn 39, Issue 1, 2014, Pages 235-240

Comparison of free-breathing with navigator-controlled acquisition regimes in abdominal diffusion-weighted magnetic resonance images: Effect on ADC and IVIM statistics

Author keywords

abdominal; diffusion; free breathing; motion; navigator; renal

Indexed keywords

ADULT; ALGORITHM; APPARENT DIFFUSION COEFFICIENT; ARTICLE; BAYES THEOREM; COMPARATIVE STUDY; DIFFUSION COEFFICIENT; DIFFUSION WEIGHTED IMAGING; FEMALE; FREE BREATHING ACQUISITION REGIME; HUMAN; HUMAN EXPERIMENT; IMAGE PROCESSING; INTRA VOXEL INCOHERENT MOTION; KIDNEY; KIDNEY CORTEX; KIDNEY MEDULLA; LIVER; MALE; MOTION ANALYSIS SYSTEM; MUSCLE; NAVIGATOR CONTROLLED ACQUISITION REGIME; NORMAL HUMAN; NUCLEAR MAGNETIC RESONANCE SCANNER; PARASPINAL MUSCLE; PRIORITY JOURNAL; RANGE OF MOTION; RENAL PYRAMID; SPLEEN;

EID: 84890472964     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.24140     Document Type: Article
Times cited : (65)

References (22)
  • 1
    • 34249874331 scopus 로고    scopus 로고
    • Diffusion-weighted MRI in the body: Applications and challenges in oncology
    • Koh D-M, Collins DJ,. Diffusion-weighted MRI in the body: applications and challenges in oncology. Am J Roentgenol 2007; 188: 1622-1635.
    • (2007) Am J Roentgenol , vol.188 , pp. 1622-1635
    • Koh, D.-M.1    Collins, D.J.2
  • 2
    • 0031927363 scopus 로고    scopus 로고
    • Magnetic resonance image segmentation using pattern recognition, and applied to image registration and quantitation
    • Saeed N,. Magnetic resonance image segmentation using pattern recognition, and applied to image registration and quantitation. NMR Biomed 1998; 11: 157-167.
    • (1998) NMR Biomed , vol.11 , pp. 157-167
    • Saeed, N.1
  • 3
    • 14044270157 scopus 로고    scopus 로고
    • Non-rigid image registration: Theory and practice
    • Crum WR,. Non-rigid image registration: theory and practice. Br J Radiol 2004; 77: S140-S153.
    • (2004) Br J Radiol , vol.77
    • Crum, W.R.1
  • 4
    • 45849106903 scopus 로고    scopus 로고
    • Practical aspects of assessing tumors using clinical diffusion-weighted imaging in the body
    • Koh D-M, Takahara T, Imai Y, Collins DJ,. Practical aspects of assessing tumors using clinical diffusion-weighted imaging in the body. Magn Reson Med Sci 2007; 6: 211-224.
    • (2007) Magn Reson Med Sci , vol.6 , pp. 211-224
    • Koh, D.-M.1    Takahara, T.2    Imai, Y.3    Collins, D.J.4
  • 5
    • 77951122163 scopus 로고    scopus 로고
    • Diffusion tensor imaging (DTI) of the kidney at 3 Tesla-feasibility, protocol evaluation and comparison to 1.5 Tesla
    • et al.
    • Notohamiprodjo M, Dietrich O, Horger W, et al. Diffusion tensor imaging (DTI) of the kidney at 3 Tesla-feasibility, protocol evaluation and comparison to 1.5 Tesla. Invest Radiol 2010; 45: 245-254.
    • (2010) Invest Radiol , vol.45 , pp. 245-254
    • Notohamiprodjo, M.1    Dietrich, O.2    Horger, W.3
  • 6
    • 0028175715 scopus 로고
    • The influence of respiration induced motion of the kidneys on the accuracy of radiotherapy treatment planning, a magnetic resonance imaging study
    • et al.
    • Moerland MA, Van den Bergh AC, Bhagwandien R, et al. The influence of respiration induced motion of the kidneys on the accuracy of radiotherapy treatment planning, a magnetic resonance imaging study. Radiother Oncol 1994; 30: 150-154.
    • (1994) Radiother Oncol , vol.30 , pp. 150-154
    • Moerland, M.A.1    Van Den Bergh, A.C.2    Bhagwandien, R.3
  • 8
    • 79960529109 scopus 로고    scopus 로고
    • Intravoxel incoherent motion in body diffusion-weighted MRI: Reality and challenges
    • Koh D-M, Collins DJ, Orton MR,. Intravoxel incoherent motion in body diffusion-weighted MRI: reality and challenges. Am J Roentgenol 2011; 196: 1351-1361.
    • (2011) Am J Roentgenol , vol.196 , pp. 1351-1361
    • Koh, D.-M.1    Collins, D.J.2    Orton, M.R.3
  • 9
    • 79953013835 scopus 로고    scopus 로고
    • Diffusion-weighted MR imaging of native and transplanted kidneys
    • Thoeny HC, De Keyzer F,. Diffusion-weighted MR imaging of native and transplanted kidneys. Radiology 2011; 259: 25-38.
    • (2011) Radiology , vol.259 , pp. 25-38
    • Thoeny, H.C.1    De Keyzer, F.2
  • 10
    • 84890483678 scopus 로고    scopus 로고
    • Taouli B. (ed.). Cambridge, UK: Cambridge University Press;. p.
    • Taouli B, (ed.). Extra-cranial applications of diffusion-weighted MRI. Cambridge, UK: Cambridge University Press; 2011. p 216.
    • (2011) Extra-cranial Applications of Diffusion-weighted MRI , pp. 216
  • 11
    • 78649690893 scopus 로고    scopus 로고
    • Utility of the apparent diffusion coefficient for distinguishing clear cell renal cell carcinoma of low and high nuclear grade
    • Rosenkrantz AB, Niver BE, Fitzgerald EF, Babb JS, Chandarana H, Melamed J,. Utility of the apparent diffusion coefficient for distinguishing clear cell renal cell carcinoma of low and high nuclear grade. Am J Roentgenol 2010; 195: W344-151.
    • (2010) Am J Roentgenol , vol.195
    • Rosenkrantz, A.B.1    Niver, B.E.2    Fitzgerald, E.F.3    Babb, J.S.4    Chandarana, H.5    Melamed, J.6
  • 12
    • 77957358106 scopus 로고    scopus 로고
    • Renal cell carcinoma: Diffusion-weighted MR imaging for subtype differentiation at 3.0T
    • et al.
    • Wang H, Cheng L, Zhang X, et al. Renal cell carcinoma: diffusion-weighted MR imaging for subtype differentiation at 3.0T. Radiology 2010; 257: 135-143.
    • (2010) Radiology , vol.257 , pp. 135-143
    • Wang, H.1    Cheng, L.2    Zhang, X.3
  • 13
    • 0027158141 scopus 로고
    • On the use of Bayesian probability theory for analysis of exponential decay data: An example taken from intravoxel incoherent motion experiments
    • Neil JJ, Bretthorst GL,. On the use of Bayesian probability theory for analysis of exponential decay data: an example taken from intravoxel incoherent motion experiments. Magn Reson Med 1993; 29: 642-647.
    • (1993) Magn Reson Med , vol.29 , pp. 642-647
    • Neil, J.J.1    Bretthorst, G.L.2
  • 14
    • 0032884749 scopus 로고    scopus 로고
    • Measuring agreement in method comparison studies
    • Bland JM, Altman DG,. Measuring agreement in method comparison studies. Stat Methods Med Res 1999; 8: 135-160.
    • (1999) Stat Methods Med Res , vol.8 , pp. 135-160
    • Bland, J.M.1    Altman, D.G.2
  • 15
    • 18844398665 scopus 로고    scopus 로고
    • Imaging of kidneys in healthy volunteers and patients with parenchymal diseases: Initial experience
    • Thoeny HC, De Keyzer F, Oyen RH, Peeters RR,. Imaging of kidneys in healthy volunteers and patients with parenchymal diseases: initial experience. Radiology 2005; 235: 911-917.
    • (2005) Radiology , vol.235 , pp. 911-917
    • Thoeny, H.C.1    De Keyzer, F.2    Oyen, R.H.3    Peeters, R.R.4
  • 16
    • 66149136861 scopus 로고    scopus 로고
    • Renal lesions: Characterization with diffusion-weighted imaging versus contrast-enhanced MR imaging
    • et al.
    • Taouli B, Thakur RK, Mannelli L, et al. Renal lesions: characterization with diffusion-weighted imaging versus contrast-enhanced MR imaging. Radiology 2009; 251: 398.
    • (2009) Radiology , vol.251 , pp. 398
    • Taouli, B.1    Thakur, R.K.2    Mannelli, L.3
  • 17
    • 84862985414 scopus 로고    scopus 로고
    • Diffusion, confusion and functional MRI
    • Le Bihan D,. Diffusion, confusion and functional MRI. NeuroImage 2012; 62: 1131-1136.
    • (2012) NeuroImage , vol.62 , pp. 1131-1136
    • Le Bihan, D.1
  • 18
    • 18244400115 scopus 로고    scopus 로고
    • RESTORE: Robust estimation of tensors by outlier rejection
    • Chang L-C, Jones DK, Pierpaoli C,. RESTORE: robust estimation of tensors by outlier rejection. Magn Reson Med 2005; 53: 1088-1095.
    • (2005) Magn Reson Med , vol.53 , pp. 1088-1095
    • Chang, L.-C.1    Jones, D.K.2    Pierpaoli, C.3
  • 19
    • 78649487473 scopus 로고    scopus 로고
    • Apparent diffusion coefficient measurement in a moving phantom simulating linear respiratory motion
    • et al.
    • Kwee TC, Takahara T, Muro I, et al. Apparent diffusion coefficient measurement in a moving phantom simulating linear respiratory motion. Jpn J Radiol 2010; 28: 578-583.
    • (2010) Jpn J Radiol , vol.28 , pp. 578-583
    • Kwee, T.C.1    Takahara, T.2    Muro, I.3
  • 20
    • 77951607883 scopus 로고    scopus 로고
    • Comparison of physiological triggering schemes for diffusion-weighted magnetic resonance imaging in kidneys
    • Binser T, Thoeny HC, Eisenberger U, Stemmer A, Boesch C, Vermathen P,. Comparison of physiological triggering schemes for diffusion-weighted magnetic resonance imaging in kidneys. J Magn Reson Imaging 2010; 31: 1144-1150.
    • (2010) J Magn Reson Imaging , vol.31 , pp. 1144-1150
    • Binser, T.1    Thoeny, H.C.2    Eisenberger, U.3    Stemmer, A.4    Boesch, C.5    Vermathen, P.6
  • 21
    • 69449085107 scopus 로고    scopus 로고
    • Diffusion-weighted imaging of the liver: Comparison of navigator triggered and breathhold acquisitions
    • et al.
    • Taouli B, Sandberg A, Stemmer A, et al. Diffusion-weighted imaging of the liver: comparison of navigator triggered and breathhold acquisitions. J Magn Reson Imaging 2009; 30: 561-568.
    • (2009) J Magn Reson Imaging , vol.30 , pp. 561-568
    • Taouli, B.1    Sandberg, A.2    Stemmer, A.3
  • 22
    • 55749097922 scopus 로고    scopus 로고
    • Comparison and reproducibility of ADC measurements in breathhold, respiratory triggered, and free-breathing diffusion-weighted MR imaging of the liver
    • Kwee TC, Takahara T, Koh D-M, Nievelstein R, a J, Luijten PR,. Comparison and reproducibility of ADC measurements in breathhold, respiratory triggered, and free-breathing diffusion-weighted MR imaging of the liver. J Magn Reson Imaging 2008; 28: 1141-1148.
    • (2008) J Magn Reson Imaging , vol.28 , pp. 1141-1148
    • Kwee, T.C.1    Takahara, T.2    Koh, D.-M.3    Nievelstein, R.4    Luijten, P.R.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.