Diffusion tensor imaging (DTI) of the kidney at 3 tesla-feasibility, protocol evaluation and comparison to 1.5 tesla

Author keywords

3T; Diffusion tensor imaging; DTI; DWI; Kidney; Reproducibility

Indexed keywords

ADULT; ARTICLE; CONTRAST; DIFFUSION TENSOR IMAGING; FEMALE; HUMAN; HUMAN EXPERIMENT; IMAGING SYSTEM; MALE; NORMAL HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; RANK SUM TEST; SIGNAL NOISE RATIO;

EID: 77951122163     PISSN: 00209996     EISSN: 15360210     Source Type: Journal    
DOI: 10.1097/RLI.0b013e3181d83abc     Document Type: Article
Times cited : (96)

References (47)
  • 1
    • 63449094082 scopus 로고    scopus 로고
    • Diffusion tensor imaging of kidneys with respiratory triggering: Optimization of parameters to demonstrate aniso-tropic structures on fraction anisotropy maps
    • Kataoka M, Kido A, Yamamoto A, et al. Diffusion tensor imaging of kidneys with respiratory triggering: optimization of parameters to demonstrate aniso-tropic structures on fraction anisotropy maps. J Magn Reson Imaging. 2009;29:736-744.
    • (2009) J Magn Reson Imaging , vol.29 , pp. 736-744
    • Kataoka, M.1    Kido, A.2    Yamamoto, A.3
  • 2
    • 0032996364 scopus 로고    scopus 로고
    • Measurement of the apparent diffusion coefficient in diffuse renal disease by diffusion-weighted echo-planar MR imaging
    • Namimoto T, Yamashita Y, Mitsuzaki K, et al. Measurement of the apparent diffusion coefficient in diffuse renal disease by diffusion-weighted echo-planar MR imaging. J Magn Reson Imaging. 1999;9:832-837.
    • (1999) J Magn Reson Imaging , vol.9 , pp. 832-837
    • Namimoto, T.1    Yamashita, Y.2    Mitsuzaki, K.3
  • 4
    • 58149392650 scopus 로고    scopus 로고
    • Diffusion tensor imaging of the kidney with parallel imaging: Initial clinical experience
    • Notohamiprodjo M, Glaser C, Herrmann KA, et al. Diffusion tensor imaging of the kidney with parallel imaging: initial clinical experience. Invest Radiol. 2008;43:677-685.
    • (2008) Invest Radiol , vol.43 , pp. 677-685
    • Notohamiprodjo, M.1    Glaser, C.2    Herrmann, K.A.3
  • 5
    • 0028090623 scopus 로고
    • Functional imaging of the kidney by means of measurement of the apparent diffusion coefficient
    • Muller MF, Prasad PV, Bimmler D, et al. Functional imaging of the kidney by means of measurement of the apparent diffusion coefficient. Radiology. 1994;193:711-715.
    • (1994) Radiology , vol.193 , pp. 711-715
    • Muller, M.F.1    Prasad, P.V.2    Bimmler, D.3
  • 6
    • 0347527090 scopus 로고    scopus 로고
    • Age dependence of the renal apparent diffusion coefficient in children
    • Jones RA, Grattan-Smith JD. Age dependence of the renal apparent diffusion coefficient in children. Pediatr Radiol. 2003;33:850-854.
    • (2003) Pediatr Radiol , vol.33 , pp. 850-854
    • Jones, R.A.1    Grattan-Smith, J.D.2
  • 7
    • 18844398665 scopus 로고    scopus 로고
    • Diffusion-weighted MR imaging of kidneys in healthy volunteers and patients with parenchymal diseases: Initial experience
    • Thoeny HC, De Keyzer F, Oyen RH, et al. Diffusion-weighted MR imaging of kidneys in healthy volunteers and patients with parenchymal diseases: initial experience. Radiology. 2005;235:911-917.
    • (2005) Radiology , vol.235 , pp. 911-917
    • Thoeny, H.C.1    De Keyzer, F.2    Oyen, R.H.3
  • 8
    • 0036868662 scopus 로고    scopus 로고
    • Fiber tracking: Principles and strategies\a technical review
    • Mori S, van Zijl PC. Fiber tracking: principles and strategies\a technical review. NMR Biomed. 2002;15:468-480.
    • (2002) NMR Biomed , vol.15 , pp. 468-480
    • Mori, S.1    Van Zijl, P.C.2
  • 9
    • 67651091583 scopus 로고    scopus 로고
    • Absolute quantification of regional renal blood flow in swine by dynamic contrast-enhanced magnetic resonance imaging using a blood pool contrast agent
    • Ludemann L, Nafz B, Elsner F, et al. Absolute quantification of regional renal blood flow in swine by dynamic contrast-enhanced magnetic resonance imaging using a blood pool contrast agent. Invest Radiol. 2009;44:125-134.
    • (2009) Invest Radiol , vol.44 , pp. 125-134
    • Ludemann, L.1    Nafz, B.2    Elsner, F.3
  • 10
    • 73349130631 scopus 로고    scopus 로고
    • Comprehensive assessment of renal function and vessel morphology in potential living kidney donors: An MRI-based approach
    • Rossi C, Boss A, Artunc F, et al. Comprehensive assessment of renal function and vessel morphology in potential living kidney donors: an MRI-based approach. Invest Radiol. 2009;44:705-711.
    • (2009) Invest Radiol , vol.44 , pp. 705-711
    • Rossi, C.1    Boss, A.2    Artunc, F.3
  • 11
    • 77951100920 scopus 로고    scopus 로고
    • Evaluation of normal and dysfunctional renal transplants using DTI
    • Chandarana H, Lee VS, Stoffel D, et al. Evaluation of normal and dysfunctional renal transplants using DTI. Proc Intl Soc Magn Reson Med. 2009;17: 4112.
    • (2009) Proc Intl Soc Magn Reson Med , vol.17 , pp. 4112
    • Chandarana, H.1    Lee, V.S.2    Stoffel, D.3
  • 12
    • 77951124384 scopus 로고    scopus 로고
    • Diffusion tensor imaging of renal ischemia/reperfusion injury
    • Cheung JS, Fan SJ, Chow AM, et al. Diffusion tensor imaging of renal ischemia/reperfusion injury. Proc Intl Soc Magn Reson Med. 2009;17:669.
    • (2009) Proc Intl Soc Magn Reson Med , vol.17 , pp. 669
    • Cheung, J.S.1    Fan, S.J.2    Chow, A.M.3
  • 13
    • 70350724281 scopus 로고    scopus 로고
    • Comparison of 1.5 and 3 T BOLD MR to study oxygenation of kidney cortex and medulla in human renovascular disease
    • Gloviczki ML, Glockner J, Gomez SI, et al. Comparison of 1.5 and 3 T BOLD MR to study oxygenation of kidney cortex and medulla in human renovascular disease. Invest Radiol. 2009;44:566-571.
    • (2009) Invest Radiol , vol.44 , pp. 566-571
    • Gloviczki, M.L.1    Glockner, J.2    Gomez, S.I.3
  • 14
    • 34249001304 scopus 로고    scopus 로고
    • Intraindividual comparison of MR-renal perfusion imaging at 1.5 T and 3.0 T
    • Michaely HJ, Kramer H, Oesingmann N, et al. Intraindividual comparison of MR-renal perfusion imaging at 1.5 T and 3.0 T. Invest Radiol. 2007;42:406-411.
    • (2007) Invest Radiol , vol.42 , pp. 406-411
    • Michaely, H.J.1    Kramer, H.2    Oesingmann, N.3
  • 15
    • 58149389519 scopus 로고    scopus 로고
    • 3.0-T MR imaging of the abdomen: Comparison with 1.5 T
    • Chang KJ, Kamel IR, Macura KJ, et al. 3.0-T MR imaging of the abdomen: comparison with 1.5 T. Radiographics. 2008;28:1983-1998.
    • (2008) Radiographics , vol.28 , pp. 1983-1998
    • Chang, K.J.1    Kamel, I.R.2    MacUra, K.J.3
  • 16
    • 37549014118 scopus 로고    scopus 로고
    • Artifacts in 3-T MRI: Physical background and reduction strategies
    • Dietrich O, Reiser MF, Schoenberg SO. Artifacts in 3-T MRI: physical background and reduction strategies. Eur J Radiol. 2008;65:29-35.
    • (2008) Eur J Radiol , vol.65 , pp. 29-35
    • Dietrich, O.1    Reiser, M.F.2    Schoenberg, S.O.3
  • 17
    • 33646840836 scopus 로고    scopus 로고
    • Comparison of diffusion tensor imaging measurements at 3.0 T versus 1.5 T with and without parallel imaging
    • Alexander AL, Lee JE, Wu YC, et al. Comparison of diffusion tensor imaging measurements at 3.0 T versus 1.5 T with and without parallel imaging. Neuroimaging Clin N Am. 2006;16:299-309, xi.
    • (2006) Neuroimaging Clin N Am , vol.16 , pp. 299-309
    • Alexander, A.L.1    Lee, J.E.2    Wu, Y.C.3
  • 18
    • 34247642784 scopus 로고    scopus 로고
    • Diffusion tensor imaging of the spinal cord at 1.5 and 3.0 Tesla
    • Rossi C, Boss A, Lindig TM, et al. Diffusion tensor imaging of the spinal cord at 1.5 and 3.0 Tesla. Rofo. 2007;179:219-224.
    • (2007) Rofo , vol.179 , pp. 219-224
    • Rossi, C.1    Boss, A.2    Lindig, T.M.3
  • 19
    • 33751225105 scopus 로고    scopus 로고
    • ADC measurements of abdominal organs and lesions using parallel imaging technique
    • Yoshikawa T, Kawamitsu H, Mitchell DG, et al. ADC measurements of abdominal organs and lesions using parallel imaging technique. Am J Roent-genol. 2006;187:1521-1530.
    • (2006) Am J Roent-genol , vol.187 , pp. 1521-1530
    • Yoshikawa, T.1    Kawamitsu, H.2    Mitchell, D.G.3
  • 20
  • 21
    • 0036263907 scopus 로고    scopus 로고
    • Generalized autocalibrating partially parallel acquisitions (GRAPPA)
    • Griswold MA, Jakob PM, Heidemann RM, et al. Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn Reson Med. 2002;47:1202-1210.
    • (2002) Magn Reson Med , vol.47 , pp. 1202-1210
    • Griswold, M.A.1    Jakob, P.M.2    Heidemann, R.M.3
  • 22
    • 0029908076 scopus 로고    scopus 로고
    • Toward a quantitative assessment of diffusion anisot-ropy
    • Pierpaoli C, Basser PJ. Toward a quantitative assessment of diffusion anisot-ropy. Magn Reson Med. 1996;36:893-906.
    • (1996) Magn Reson Med , vol.36 , pp. 893-906
    • Pierpaoli, C.1    Basser, P.J.2
  • 23
    • 0031458281 scopus 로고    scopus 로고
    • Morphometry of in vivo human white matter association pathways with diffusion-weighted magnetic resonance imaging
    • Makris N, Worth AJ, Sorensen AG, et al. Morphometry of in vivo human white matter association pathways with diffusion-weighted magnetic resonance imaging. Ann Neurol. 1997;42:951-962.
    • (1997) Ann Neurol , vol.42 , pp. 951-962
    • Makris, N.1    Worth, A.J.2    Sorensen, A.G.3
  • 24
    • 0032882168 scopus 로고    scopus 로고
    • Color schemes to represent the orientation of aniso-tropic tissues from diffusion tensor data: Application to white matter fiber tract mapping in the human brain
    • Pajevic S, Pierpaoli C. Color schemes to represent the orientation of aniso-tropic tissues from diffusion tensor data: application to white matter fiber tract mapping in the human brain. Magn Reson Med. 1999;42:526-540.
    • (1999) Magn Reson Med , vol.42 , pp. 526-540
    • Pajevic, S.1    Pierpaoli, C.2
  • 25
    • 34547879249 scopus 로고    scopus 로고
    • Measurement of signal-to-noise ratios in MR images: Influence of multichannel coils, parallel imaging, and reconstruction filters
    • Dietrich O, Raya JG, Reeder SB, et al. Measurement of signal-to-noise ratios in MR images: influence of multichannel coils, parallel imaging, and reconstruction filters. J Magn Reson Imaging. 2007;26:375-385.
    • (2007) J Magn Reson Imaging , vol.26 , pp. 375-385
    • Dietrich, O.1    Raya, J.G.2    Reeder, S.B.3
  • 26
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1:307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 27
    • 33748350070 scopus 로고    scopus 로고
    • Global and regional reproducibility of T2 relaxation time measurements in human patellar cartilage
    • Glaser C, Mendlik T, Dinges J, et al. Global and regional reproducibility of T2 relaxation time measurements in human patellar cartilage. Magn Reson Med. 2006;56:527-534.
    • (2006) Magn Reson Med , vol.56 , pp. 527-534
    • Glaser, C.1    Mendlik, T.2    Dinges, J.3
  • 28
    • 11144343284 scopus 로고    scopus 로고
    • Quantitative assessment of parallel acquisition techniques in diffusion tensor imaging at 3.0 Tesla
    • Ardekani S, Sinha U. Quantitative assessment of parallel acquisition techniques in diffusion tensor imaging at 3.0 Tesla. Conf Proc IEEE Eng Med Biol Soc. 2004;2:1072-1075.
    • (2004) Conf Proc IEEE Eng Med Biol Soc , vol.2 , pp. 1072-1075
    • Ardekani, S.1    Sinha, U.2
  • 29
    • 33748577687 scopus 로고    scopus 로고
    • Abdominal magnetic resonance imaging at 3.0 T what is the ultimate gain in signal-to-noise ratio?
    • Schindera ST, Merkle EM, Dale BM, et al. Abdominal magnetic resonance imaging at 3.0 T what is the ultimate gain in signal-to-noise ratio? Acad Radiol. 2006;13:1236-1243.
    • (2006) Acad Radiol , vol.13 , pp. 1236-1243
    • Schindera, S.T.1    Merkle, E.M.2    Dale, B.M.3
  • 30
    • 37349031088 scopus 로고    scopus 로고
    • Fractional anisotropy and mean diffu-sivity: Comparison between 3.0-T and 1.5-T diffusion tensor imaging with parallel imaging using histogram and region of interest analysis
    • Fushimi Y, Miki Y, Okada T, et al. Fractional anisotropy and mean diffu-sivity: comparison between 3.0-T and 1.5-T diffusion tensor imaging with parallel imaging using histogram and region of interest analysis. NMR Biomed. 2007;20:743-748.
    • (2007) NMR Biomed , vol.20 , pp. 743-748
    • Fushimi, Y.1    Miki, Y.2    Okada, T.3
  • 31
    • 0032835247 scopus 로고    scopus 로고
    • Optimal strategies for measuring diffusion in anisotropic systems by magnetic resonance imaging
    • Jones DK, Horsfield MA, Simmons A. Optimal strategies for measuring diffusion in anisotropic systems by magnetic resonance imaging. Magn Reson Med. 1999;42:515-525.
    • (1999) Magn Reson Med , vol.42 , pp. 515-525
    • Jones, D.K.1    Horsfield, M.A.2    Simmons, A.3
  • 32
    • 1842533406 scopus 로고    scopus 로고
    • The effect of gradient sampling schemes on measures derived from diffusion tensor MRI: A Monte Carlo study
    • Jones DK. The effect of gradient sampling schemes on measures derived from diffusion tensor MRI: a Monte Carlo study. Magn Reson Med. 2004;51:807-815.
    • (2004) Magn Reson Med , vol.51 , pp. 807-815
    • Jones, D.K.1
  • 33
    • 0035038227 scopus 로고    scopus 로고
    • Comparison of gradient encoding schemes for diffusion-tensor MRI
    • Hasan KM, Parker DL, Alexander AL. Comparison of gradient encoding schemes for diffusion-tensor MRI. JMagn Reson Imaging. 2001;13:769-780.
    • (2001) JMagn Reson Imaging , vol.13 , pp. 769-780
    • Hasan, K.M.1    Parker, D.L.2    Alexander, A.L.3
  • 34
    • 0033869742 scopus 로고    scopus 로고
    • Minimal gradient encoding for robust estimation of diffusion anisotropy
    • Papadakis NG, Murrills CD, Hall LD, et al. Minimal gradient encoding for robust estimation of diffusion anisotropy. Magn Reson Imaging. 2000;18: 671-679.
    • (2000) Magn Reson Imaging , vol.18 , pp. 671-679
    • Papadakis, N.G.1    Murrills, C.D.2    Hall, L.D.3
  • 35
    • 34248671979 scopus 로고    scopus 로고
    • Extracranial applications of diffusion-weighted magnetic resonance imaging
    • Thoeny HC, De Keyzer F. Extracranial applications of diffusion-weighted magnetic resonance imaging. Eur Radiol. 2007;17:1385-1393.
    • (2007) Eur Radiol , vol.17 , pp. 1385-1393
    • Thoeny, H.C.1    De Keyzer, F.2
  • 36
    • 0022969218 scopus 로고
    • MR imaging of intravoxel incoherent motions: Application to diffusion and perfusion in neurologic disorders
    • Le Bihan D, Breton E, Lallemand D, et al. MR imaging of intravoxel incoherent motions: application to diffusion and perfusion in neurologic disorders. Radiology. 1986;161:401-407.
    • (1986) Radiology , vol.161 , pp. 401-407
    • Le Bihan, D.1    Breton, E.2    Lallemand, D.3
  • 37
    • 59249105806 scopus 로고    scopus 로고
    • Looking for the optimal DTI acquisition scheme given a maximum scan time: Are more b-values a waste of time?
    • Correia MM, Carpenter TA, Williams GB. Looking for the optimal DTI acquisition scheme given a maximum scan time: are more b-values a waste of time? Magn Reson Imaging. 2009;27:163-175.
    • (2009) Magn Reson Imaging , vol.27 , pp. 163-175
    • Correia, M.M.1    Carpenter, T.A.2    Williams, G.B.3
  • 38
    • 0033730130 scopus 로고    scopus 로고
    • Diffusion tensor MR imaging of the brain: Effect of diffusion weighting on trace and anisotropy measurements
    • Melhem ER, Itoh R, Jones L, et al. Diffusion tensor MR imaging of the brain: effect of diffusion weighting on trace and anisotropy measurements. Am J Neuroradiol. 2000;21:1813-1820.
    • (2000) Am J Neuroradiol , vol.21 , pp. 1813-1820
    • Melhem, E.R.1    Itoh, R.2    Jones, L.3
  • 39
    • 67049110254 scopus 로고    scopus 로고
    • Renal functional MRI: Are we ready for clinical application?
    • Chandarana H, Lee VS. Renal functional MRI: Are we ready for clinical application? Am J Roentgenol. 2009;192:1550-1557.
    • (2009) Am J Roentgenol , vol.192 , pp. 1550-1557
    • Chandarana, H.1    Lee, V.S.2
  • 40
    • 55749097922 scopus 로고    scopus 로고
    • Comparison and reproducibility of ADC measurements in breathhold, respiratory triggered, and free-breathing diffusion-weighted MR imaging of the liver
    • Kwee TC, Takahara T, Koh DM, et al. Comparison and reproducibility of ADC measurements in breathhold, respiratory triggered, and free-breathing diffusion-weighted MR imaging of the liver. J Magn Reson Imaging. 2008; 28:1141-1148.
    • (2008) J Magn Reson Imaging , vol.28 , pp. 1141-1148
    • Kwee, T.C.1    Takahara, T.2    Koh, D.M.3
  • 41
    • 49049105451 scopus 로고    scopus 로고
    • Diffusion-weighted whole-body imaging with background body signal suppression (DWIBS): Features and potential applications in oncology
    • Kwee TC, Takahara T, Ochiai R, et al. Diffusion-weighted whole-body imaging with background body signal suppression (DWIBS): features and potential applications in oncology. Eur Radiol. 2008;18:1937-1952.
    • (2008) Eur Radiol , vol.18 , pp. 1937-1952
    • Kwee, T.C.1    Takahara, T.2    Ochiai, R.3
  • 42
    • 4644278852 scopus 로고    scopus 로고
    • Diffusion weighted whole body imaging with background body signal suppression (DWIBS): Technical improvement using free breathing STIR and high resolution 3D display
    • Takahara T, Imai Y, Yamashita T, et al. Diffusion weighted whole body imaging with background body signal suppression (DWIBS): technical improvement using free breathing, STIR and high resolution 3D display. Radiat Med. 2004;22:275-282.
    • (2004) Radiat Med , vol.22 , pp. 275-282
    • Takahara, T.1    Imai, Y.2    Yamashita, T.3
  • 43
    • 61749088918 scopus 로고    scopus 로고
    • Short-and midterm reproducibility of apparent diffusion coefficient measurements at 3.0-T diffusion-weighted imaging of the abdomen
    • Braithwaite AC, Dale BM, Boll DT, et al. Short-and midterm reproducibility of apparent diffusion coefficient measurements at 3.0-T diffusion-weighted imaging of the abdomen. Radiology. 2009;250:459-465.
    • (2009) Radiology , vol.250 , pp. 459-465
    • Braithwaite, A.C.1    Dale, B.M.2    Boll, D.T.3
  • 44
    • 36248985628 scopus 로고    scopus 로고
    • Hepatic pseudo-anisotropy: A specific artifact in hepatic diffusion-weighted images obtained with respiratory triggering
    • Nasu K, Kuroki Y, Fujii H, et al. Hepatic pseudo-anisotropy: a specific artifact in hepatic diffusion-weighted images obtained with respiratory triggering. MAGMA. 2007;20:205-211.
    • (2007) MAGMA , vol.20 , pp. 205-211
    • Nasu, K.1    Kuroki, Y.2    Fujii, H.3
  • 45
    • 7544247899 scopus 로고    scopus 로고
    • Squashing peanuts and smashing pumpkins: How noise distorts diffusion-weighted MR data
    • Jones DK, Basser PJ. Squashing peanuts and smashing pumpkins: how noise distorts diffusion-weighted MR data. Magn Reson Med. 2004;52:979-993.
    • (2004) Magn Reson Med , vol.52 , pp. 979-993
    • Jones, D.K.1    Basser, P.J.2
  • 46
    • 67650473707 scopus 로고    scopus 로고
    • Assessing and minimizing the effects of noise and motion in clinical DTI at 3 T
    • Tijssen RH, Jansen JF, Backes WH. Assessing and minimizing the effects of noise and motion in clinical DTI at 3 T. Hum Brain Mapp. 2009;30:2641-2655
    • (2009) Hum Brain Mapp , vol.30 , pp. 2641-2655
    • Tijssen, R.H.1    Jansen, J.F.2    Backes, W.H.3
  • 47
    • 0343193133 scopus 로고    scopus 로고
    • Pulse triggering for improved diffusion-weighted MR imaging of the abdomen
    • Murtz P, Pauleit D, Traber F, et al. [Pulse triggering for improved diffusion-weighted MR imaging of the abdomen.] Rofo. 2000;172:587-590.
    • (2000) Rofo , vol.172 , pp. 587-590
    • Murtz, P.1    Pauleit, D.2    Traber, F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.