메뉴 건너뛰기




Volumn 24, Issue 1, 2014, Pages 169-175

Multidetector CT radiation dose optimisation in adults: Short- and long-term effects of a clinical audit

Author keywords

Body CT; CT; Head CT; Quality assurance; Radiation dose

Indexed keywords

ABDOMEN; ARTICLE; CERVICAL SPINE; COMPUTED TOMOGRAPHY SCANNER; CONTROLLED STUDY; DRUG DOSE REDUCTION; EUROPEAN UNION; FOLLOW UP; HEAD; HUMAN; IMAGE QUALITY; LUMBAR SPINE; LUXEMBOURG; MAJOR CLINICAL STUDY; MEDICAL AUDIT; MULTIDETECTOR COMPUTED TOMOGRAPHY; OBSERVATIONAL STUDY; PRIORITY JOURNAL; QUALITY CONTROL; RADIATION DOSE; RADIOLOGY PHANTOM; THORAX;

EID: 84890438755     PISSN: 09387994     EISSN: 14321084     Source Type: Journal    
DOI: 10.1007/s00330-013-2994-8     Document Type: Article
Times cited : (32)

References (30)
  • 1
    • 77949419896 scopus 로고    scopus 로고
    • Radiologic and nuclear medicine studies in the United States and worldwide: Frequency, radiation dose, and comparison with other radiation sources: 1950-2007
    • Mettler FA, Bhargavan M, Faulkner K et al (2009) Radiologic and nuclear medicine studies in the United States and worldwide: frequency, radiation dose, and comparison with other radiation sources: 1950-2007. Radiology 253:520-553
    • (2009) Radiology , vol.253 , pp. 520-553
    • Mettler, F.A.1    Bhargavan, M.2    Faulkner, K.3
  • 2
    • 77954589114 scopus 로고    scopus 로고
    • Radiation exposure from medical imaging
    • Brenner DJ, Hricak H (2010) Radiation exposure from medical imaging. JAMA 304:208-209
    • (2010) JAMA , vol.304 , pp. 208-209
    • Brenner, D.J.1    Hricak, H.2
  • 3
    • 36549007486 scopus 로고    scopus 로고
    • Computed tomography-an increasing source of radiation exposure
    • Brenner DJ, Hall EJ (2007) Computed tomography-an increasing source of radiation exposure. N Engl J Med 357:2277-2284
    • (2007) N Engl J Med , vol.357 , pp. 2277-2284
    • Brenner, D.J.1    Hall, E.J.2
  • 6
    • 84890437559 scopus 로고    scopus 로고
    • Accessed 2 Apr 2013
    • American College of Radiology (2013) Appropriateness criteria - diagnostic imaging. http://www.acr.org/Quality-Safety/Appropriateness-Criteria/ Diagnostic. Accessed 2 Apr 2013
    • (2013) Appropriateness Criteria - Diagnostic Imaging
  • 7
    • 84890427708 scopus 로고    scopus 로고
    • Accessed 2 Apr 2013
    • The Royal College of Radiology (2013) RCR referral guidelines. http://www.rcr.ac.uk/content.aspx?PageID=995. Accessed 2 Apr 2013
    • (2013) RCR Referral Guidelines
  • 9
    • 0003892109 scopus 로고    scopus 로고
    • Commission E EUR 16262EN. Office for Official Publications of the European. Communities, Luxembourg
    • Commission E (2000) European guidelines on quality criteria for computed tomography, EUR 16262EN. Office for Official Publications of the European. Communities, Luxembourg
    • (2000) European Guidelines on Quality Criteria for Computed Tomography
  • 10
    • 77952694505 scopus 로고    scopus 로고
    • Radiation exposure in CT: What is the professionally responsible approach?
    • Golding SJ (2010) Radiation exposure in CT: what is the professionally responsible approach? Radiology 255:683-686
    • (2010) Radiology , vol.255 , pp. 683-686
    • Golding, S.J.1
  • 13
    • 77952391042 scopus 로고    scopus 로고
    • Radiation dose survey: Comparison between new-generation computed tomography and 64-slice multidetector computed tomography
    • Lo GG, Chan JKF, Lau CW, Geng H, Yu SK (2010) Radiation dose survey: comparison between new-generation computed tomography and 64-slice multidetector computed tomography. J HK Coll Radiol 12:107-112
    • (2010) J HK Coll Radiol , vol.12 , pp. 107-112
    • Lo, G.G.1    Chan, J.K.F.2    Lau, C.W.3    Geng, H.4    Yu, S.K.5
  • 15
    • 78851469820 scopus 로고    scopus 로고
    • Patient doses in CT examinations in Switzerland: Implementation of national diagnostic reference levels
    • Treier R, Aroua A, Verdun FR, Samara E, Stuessi A, Trueb PR (2010) Patient doses in CT examinations in Switzerland: implementation of national diagnostic reference levels. Radiat Prot Dosimetry 142:244-254
    • (2010) Radiat Prot Dosimetry , vol.142 , pp. 244-254
    • Treier, R.1    Aroua, A.2    Verdun, F.R.3    Samara, E.4    Stuessi, A.5    Trueb, P.R.6
  • 16
    • 84890430919 scopus 로고    scopus 로고
    • Collective radiation dose from MDCT: Critical review of surveys studies
    • Tack D, Kalra MK, Gevenois PA (eds) Springer, Heidelberg
    • Stamm G (2012) Collective radiation dose from MDCT: critical review of surveys studies. In: Tack D, Kalra MK, Gevenois PA (eds) Radiation dose from multidetector CT. Springer, Heidelberg, pp 209-229
    • (2012) Radiation Dose from Multidetector CT , pp. 209-229
    • Stamm, G.1
  • 18
    • 0043136286 scopus 로고    scopus 로고
    • Radiation exposure in multi-slice versus single-slice spiral CT: Results of a nationwide survey
    • Brix G, Nagel HD, Stamm G, Veit R, Lechel U, Griebel J, Galanski M (2003) Radiation exposure in multi-slice versus single-slice spiral CT: results of a nationwide survey. Eur Radiol 13:1979-1991
    • (2003) Eur Radiol , vol.13 , pp. 1979-1991
    • Brix, G.1    Nagel, H.D.2    Stamm, G.3    Veit, R.4    Lechel, U.5    Griebel, J.6    Galanski, M.7
  • 20
    • 0036923914 scopus 로고    scopus 로고
    • CT-expo-a novel program for dose evaluation in CT
    • Stamm G, Nagel HD (2002) CT-expo-a novel program for dose evaluation in CT. RöFo 174:1570-1576
    • (2002) RöFo , vol.174 , pp. 1570-1576
    • Stamm, G.1    Nagel, H.D.2
  • 22
    • 67349231679 scopus 로고    scopus 로고
    • Methods and strategies for radiation dose optimization and reduction in MDCT with special focus on the image quality
    • Tack D, Gevenois PA (eds) Springer, Berlin
    • TackD (2007) Methods and strategies for radiation dose optimization and reduction in MDCT with special focus on the image quality. In: Tack D, Gevenois PA (eds) Radiation dose from adult and pediatric multidetector computed tomography. Springer, Berlin, pp 99-116
    • (2007) Radiation Dose from Adult and Pediatric Multidetector Computed Tomography , pp. 99-116
    • Tack, D.1
  • 23
    • 81255163032 scopus 로고    scopus 로고
    • Automatic computed tomography patient dose calculation using DICOMheader metadata
    • Jahnen A, Kohler S, Hermen J, Tack D, Back C (2011) Automatic computed tomography patient dose calculation using DICOMheader metadata. Radiat Prot Dosimetry 147:317-320
    • (2011) Radiat Prot Dosimetry , vol.147 , pp. 317-320
    • Jahnen, A.1    Kohler, S.2    Hermen, J.3    Tack, D.4    Back, C.5
  • 24
    • 77957358643 scopus 로고    scopus 로고
    • Multisection CT protocols: Sex- and age-specific conversion factors used to determine effective dose from dose-length product
    • Deak PD, Smal Y, Kalender WA (2010) Multisection CT protocols: sex- and age-specific conversion factors used to determine effective dose from dose-length product. Radiology 257:158-166
    • (2010) Radiology , vol.257 , pp. 158-166
    • Deak, P.D.1    Smal, Y.2    Kalender, W.A.3
  • 25
    • 0006290362 scopus 로고    scopus 로고
    • EC1999. Accessed 26 Jan 2013
    • European Commission (1999) Radiation protection 109: guidance on diagnostic reference levels for medical exposures. EC1999. http://www.google.be/ url?sa=t&rct=j&q=radiation%20protection%20109&source=web&cd= 1&ved=0CC4QFjAA&url=http%3A%2F%2Fec.europa. eu%2Fenergy%2Fnuclear%2Fradiation-protection%2Fdoc%2Fpublication%2F109-en. pdf&ei=0SoFUYqVJarV0QWR-4CgDg&usg= AFQjCNGlP4AT3FWU7nfk8AT2D3Tiy3j4cA&bvm=bv.41524429,d.d2k&cad=rja Accessed 26 Jan 2013
    • (1999) Radiation Protection 109: Guidance on Diagnostic Reference Levels for Medical Exposures
  • 27
    • 77954753249 scopus 로고    scopus 로고
    • Lowdose CT examinations in Crohn's disease: Impact on image quality, diagnostic performance, and radiation dose
    • Kambadakone AR, Prakash P, Hahn PF, Sahani DV (2010) Lowdose CT examinations in Crohn's disease: Impact on image quality, diagnostic performance, and radiation dose. AJR Am J Roentgenol 195:78-88
    • (2010) AJR Am J Roentgenol , vol.195 , pp. 78-88
    • Kambadakone, A.R.1    Prakash, P.2    Hahn, P.F.3    Sahani, D.V.4
  • 28
    • 77954691805 scopus 로고    scopus 로고
    • Effect of altering automatic exposure control settings and quality reference mAs on radiation dose, image quality and diagnostic efficacy in MDCT enterography of active inflammatory Crohn's disease
    • Lee SJ, Park SH, Kim AY, Yang SK, Yun SC, Lee SS, Jung GS, Ha HK (2010) Effect of altering automatic exposure control settings and quality reference mAs on radiation dose, image quality and diagnostic efficacy in MDCT enterography of active inflammatory Crohn's disease. AJR Am J Roentgenol 195:89-100
    • (2010) AJR Am J Roentgenol , vol.195 , pp. 89-100
    • Lee, S.J.1    Park, S.H.2    Kim, A.Y.3    Yang, S.K.4    Yun, S.C.5    Lee, S.S.6    Jung, G.S.7    Ha, H.K.8
  • 29
    • 84870020657 scopus 로고    scopus 로고
    • Size-specific dose estimation for CT: How should it be used and what does it mean?
    • Brink JA, Morin RL (2012) Size-specific dose estimation for CT: how should it be used and what does it mean? Radiology 265:666-668
    • (2012) Radiology , vol.265 , pp. 666-668
    • Brink, J.A.1    Morin, R.L.2
  • 30
    • 84864371144 scopus 로고    scopus 로고
    • Exposing exposure: Automated anatomy-specific CT radiation exposure extraction for quality assurance and radiation monitoring
    • Sodickson A, Warden GI, Farkas CE, Ikuta I, Prevedello LM, Andriole KP, Khorasani R (2012) Exposing exposure: automated anatomy-specific CT radiation exposure extraction for quality assurance and radiation monitoring. Radiology 264:397-405
    • (2012) Radiology , vol.264 , pp. 397-405
    • Sodickson, A.1    Warden, G.I.2    Farkas, C.E.3    Ikuta, I.4    Prevedello, L.M.5    Andriole, K.P.6    Khorasani, R.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.