메뉴 건너뛰기




Volumn 5, Issue 22, 2013, Pages 2821-2836

Progress in the development of paper-based diagnostics for low-resource point-of-care settings

Author keywords

[No Author keywords available]

Indexed keywords

CELLULOSE; PYROXYLIN; REAGENT;

EID: 84889598799     PISSN: 17576180     EISSN: 17576199     Source Type: Journal    
DOI: 10.4155/bio.13.243     Document Type: Review
Times cited : (64)

References (86)
  • 1
    • 79953168450 scopus 로고    scopus 로고
    • Miniaturized isothermal nucleic acid amplification, a review
    • Asiello PJ, Baeumner AJ. Miniaturized isothermal nucleic acid amplification, a review. Lab Chip 11(8), 1420-1430 (2011
    • (2011) Lab Chip , vol.11 , Issue.8 , pp. 1420-1430
    • Asiello, P.J.1    Baeumner, A.J.2
  • 4
    • 58149378331 scopus 로고    scopus 로고
    • Three-dimensional microfluidic devices fabricated in layered paper and tape
    • Martinez AW, Phillips ST, Whitesides GM. Three-dimensional microfluidic devices fabricated in layered paper and tape. Proc. Natl Acad. Sci. USA 105(50), 19606-19611 (2008
    • (2008) Proc. Natl Acad. Sci. USA , vol.105 , Issue.50 , pp. 19606-19611
    • Martinez, A.W.1    Phillips, S.T.2    Whitesides, G.M.3
  • 5
    • 77956328100 scopus 로고    scopus 로고
    • Programmable diagnostic devices made from paper and tape
    • Martinez AW, Phillips ST, Nie Z et al. Programmable diagnostic devices made from paper and tape. Lab Chip 10(19), 2499-2504 (2010
    • (2010) Lab Chip , vol.10 , Issue.19 , pp. 2499-2504
    • Martinez, A.W.1    Phillips, S.T.2    Nie, Z.3
  • 6
    • 84858725997 scopus 로고    scopus 로고
    • Measuring markers of liver function using a micropatterned paper device designed for blood from a fingerstick
    • Vella SJ, Beattie P, Cademartiri R et al. Measuring markers of liver function using a micropatterned paper device designed for blood from a fingerstick. Anal. Chem. 84(6), 2883-2891 (2012
    • (2012) Anal. Chem , vol.84 , Issue.6 , pp. 2883-2891
    • Vella, S.J.1    Beattie, P.2    Cademartiri, R.3
  • 7
    • 75749113741 scopus 로고    scopus 로고
    • Diagnostics for the developing world: Microfluidic paper-based analytical devices
    • Martinez A, Phillips S, Whitesides G, Carrilho E. Diagnostics for the developing world: Microfluidic paper-based analytical devices. Anal. Chem. 82(1), 3-10 (2010
    • (2010) Anal. Chem , vol.82 , Issue.1 , pp. 3-10
    • Martinez, A.1    Phillips, S.2    Whitesides, G.3    Carrilho, E.4
  • 8
    • 69449085857 scopus 로고    scopus 로고
    • Bioactive paper provides a low-cost platform for diagnostics
    • Pelton R. Bioactive paper provides a low-cost platform for diagnostics. Trends Analyt. Chem. 28(8), 925-942 (2009
    • (2009) Trends Analyt. Chem , vol.28 , Issue.8 , pp. 925-942
    • Pelton, R.1
  • 9
    • 84876208351 scopus 로고    scopus 로고
    • The evolution of nitrocellulose as a material for bioassays
    • Fridley GE, Holstein CA, Oza SB, Yager P. The evolution of nitrocellulose as a material for bioassays. MRS Bull. 38(4), 326-330 (2013
    • (2013) MRS Bull , vol.38 , Issue.4 , pp. 326-330
    • Fridley, G.E.1    Holstein, C.A.2    Oza, S.B.3    Yager, P.4
  • 10
    • 84871738292 scopus 로고    scopus 로고
    • Patterned paper and alternative materials as substrates for low-cost microfluidic diagnostics
    • Ballerini DR, Li X, Shen W. Patterned paper and alternative materials as substrates for low-cost microfluidic diagnostics. Microfluid. Nanofluidics 13(5), 769-787 (2012
    • (2012) Microfluid. Nanofluidics , vol.13 , Issue.5 , pp. 769-787
    • Ballerini, D.R.1    Li, X.2    Shen, W.3
  • 11
    • 84859351413 scopus 로고    scopus 로고
    • A perspective on paper-based microfluidics: Current status and future trends
    • Li X, Ballerini DR, Shen W. A perspective on paper-based microfluidics: Current status and future trends. Biomicrofluidics 6(1), 11301-1130113 (2012
    • (2012) Biomicrofluidics , vol.6 , Issue.1 , pp. 11301-1130113
    • Li, X.1    Ballerini, D.R.2    Shen, W.3
  • 13
    • 75749087179 scopus 로고    scopus 로고
    • Electrochemical sensing in paper-based microfluidic devices
    • Nie Z, Nijhuis CA, Gong J et al. Electrochemical sensing in paper-based microfluidic devices. Lab Chip 10(4), 477-483 (2010
    • (2010) Lab Chip , vol.10 , Issue.4 , pp. 477-483
    • Nie, Z.1    Nijhuis, C.A.2    Gong, J.3
  • 14
    • 84876266157 scopus 로고    scopus 로고
    • Paper-based electroanalytical devices for accessible diagnostic testing
    • Maxwell EJ, Mazzeo AD, Whitesides GM. Paper-based electroanalytical devices for accessible diagnostic testing. MRS Bull. 38(4), 309-314 (2013
    • (2013) MRS Bull , vol.38 , Issue.4 , pp. 309-314
    • Maxwell, E.J.1    Mazzeo, A.D.2    Whitesides, G.M.3
  • 16
    • 79955530812 scopus 로고    scopus 로고
    • Paper electronics
    • Tobjork D, Osterbacka R. Paper electronics. Adv. Mater. 23(17), 1935-1961 (2011
    • (2011) Adv. Mater , vol.23 , Issue.17 , pp. 1935-1961
    • Tobjork, D.1    Osterbacka, R.2
  • 17
    • 79952074069 scopus 로고    scopus 로고
    • Rapid visual tests: Fast and reliable detection of ochratoxin A
    • Bazin I, Nabais E, Lopez-Ferber M Rapid visual tests: Fast and reliable detection of ochratoxin A. Toxins (Basel) 2(9), 2230-2241 (2010
    • (2010) Toxins (Basel , vol.2 , Issue.9 , pp. 2230-2241
    • Bazin, I.1    Nabais, E.2    Lopez-Ferber, M.3
  • 18
    • 84871569030 scopus 로고    scopus 로고
    • Development of paper-based analytical kit for point-of-care testing
    • Shah P, Zhu XN, Li CZ. Development of paper-based analytical kit for point-of-care testing. Expert Rev. Mol. Diagn. 13(1), 83-91 (2013
    • (2013) Expert Rev. Mol. Diagn , vol.13 , Issue.1 , pp. 83-91
    • Shah, P.1    Zhu, X.N.2    Li, C.Z.3
  • 19
    • 79960932351 scopus 로고    scopus 로고
    • Disposable microfluidic substrates: Transitioning from the research laboratory into the clinic
    • Kuo JS, Chiu DT. Disposable microfluidic substrates: Transitioning from the research laboratory into the clinic. Lab Chip 11(16), 2656-2665 (2011
    • (2011) Lab Chip , vol.11 , Issue.16 , pp. 2656-2665
    • Kuo, J.S.1    Chiu, D.T.2
  • 20
    • 84876258344 scopus 로고    scopus 로고
    • Advances in materials that enable quantitative point-of-care assays
    • Phillips ST, Lewis GG. Advances in materials that enable quantitative point-of-care assays. MRS Bull. 38(4), 315-319 (2013
    • (2013) MRS Bull , vol.38 , Issue.4 , pp. 315-319
    • Phillips, S.T.1    Lewis, G.G.2
  • 21
    • 84876221684 scopus 로고    scopus 로고
    • Nanostructured paper for flexible energy and electronic devices
    • Zheng G, Cui Y, Karabulut E, Wagberg L, Zhu H, Hu L. Nanostructured paper for flexible energy and electronic devices. MRS Bull. 38(4), 320-325 (2013
    • (2013) MRS Bull , vol.38 , Issue.4 , pp. 320-325
    • Zheng, G.1    Cui, Y.2    Karabulut, E.3    Wagberg, L.4    Zhu, H.5    Hu, L.6
  • 22
    • 84876222351 scopus 로고    scopus 로고
    • Bioactive paper: Biomolecule immobilization methods and applications in environmental monitoring
    • Sicard C, Brennan JD. Bioactive paper: Biomolecule immobilization methods and applications in environmental monitoring. MRS Bull. 38(4), 331-334 (2013
    • (2013) MRS Bull , vol.38 , Issue.4 , pp. 331-334
    • Sicard, C.1    Brennan, J.D.2
  • 23
    • 84876243915 scopus 로고    scopus 로고
    • Paper as a novel material platform for devices
    • Rolland JP, Mourey DA. Paper as a novel material platform for devices. MRS Bull. 38(4), 299-305 (2013
    • (2013) MRS Bull , vol.38 , Issue.4 , pp. 299-305
    • Rolland, J.P.1    Mourey, D.A.2
  • 24
    • 84878101085 scopus 로고    scopus 로고
    • Paper-based microfluidic point-of-care diagnostic devices
    • Yetisen AK, Akram MW, Lowe CR. Paper-based microfluidic point-of-care diagnostic devices. Lab Chip 13(12), 2210-2251 (2013
    • (2013) Lab Chip , vol.13 , Issue.12 , pp. 2210-2251
    • Yetisen, A.K.1    Akram, M.W.2    Lowe, C.R.3
  • 25
    • 78049408570 scopus 로고    scopus 로고
    • Cost ana¬lysis of centralized viral load testing for antiretroviral therapy monitoring in Nicaragua, a low-HIV prevalence, low-resource setting
    • Gerlach J, Sequeira M, Alvarado V et al. Cost ana¬lysis of centralized viral load testing for antiretroviral therapy monitoring in Nicaragua, a low-HIV prevalence, low-resource setting. J. Int. AIDS Soc. 13(1) (2010
    • (2010) J. Int. AIDS Soc , vol.13 , Issue.1
    • Gerlach, J.1    Sequeira, M.2    Alvarado, V.3
  • 28
    • 77955472026 scopus 로고    scopus 로고
    • Chemical signal amplification in two-dimensional paper networks
    • Fu E, Kauffman P, Lutz B, Yager P. Chemical signal amplification in two-dimensional paper networks. Sens. Actuators B Chem. 149(1), 325-328 (2010
    • (2010) Sens. Actuators B Chem , vol.149 , Issue.1 , pp. 325-328
    • Fu, E.1    Kauffman, P.2    Lutz, B.3    Yager, P.4
  • 29
    • 80054689596 scopus 로고    scopus 로고
    • Enhanced sensitivity of lateral flow tests Using a two-dimensional paper network format
    • Fu E, Liang T, Houghtaling J et al. Enhanced sensitivity of lateral flow tests Using a two-dimensional paper network format. Anal. Chem. 83(20), 7941-7946 (2011
    • (2011) Anal. Chem , vol.83 , Issue.20 , pp. 7941-7946
    • Fu, E.1    Liang, T.2    Houghtaling, J.3
  • 30
    • 84861122286 scopus 로고    scopus 로고
    • Two-dimensional paper network format that enables simple multistep assays for use in low-resource settings in the context of malaria antigen detection
    • Fu E, Liang T, Spicar-Mihalic P, Houghtaling J, Ramachandran S, Yager P. Two-dimensional paper network format that enables simple multistep assays for use in low-resource settings in the context of malaria antigen detection. Anal. Chem. 84(10), 4574-4579 (2012
    • (2012) Anal. Chem , vol.84 , Issue.10 , pp. 4574-4579
    • Fu, E.1    Liang, T.2    Spicar-Mihalic, P.3    Houghtaling, J.4    Ramachandran, S.5    Yager, P.6
  • 31
    • 77949868628 scopus 로고    scopus 로고
    • Controlled reagent transport in disposable 2D paper networks
    • Fu E, Lutz B, Kauffman P, Yager P. Controlled reagent transport in disposable 2D paper networks. Lab Chip 10(7), 918-920 (2010
    • (2010) Lab Chip , vol.10 , Issue.7 , pp. 918-920
    • Fu, E.1    Lutz, B.2    Kauffman, P.3    Yager, P.4
  • 32
    • 84878143249 scopus 로고    scopus 로고
    • Programming paper networks for point of care diagnostics
    • Dharmaraja S, Lafleur L, Byrnes S et al. Programming paper networks for point of care diagnostics. Proc. SPIE (2013
    • (2013) Proc. SPIE
    • Dharmaraja, S.1    Lafleur, L.2    Byrnes, S.3
  • 33
    • 33947547768 scopus 로고
    • The flow of liquids through capillary spaces
    • Bell JM, Cameron FK. The flow of liquids through capillary spaces. J. Phys. Chem. 10(8), 658-674 (1906
    • (1906) J. Phys. Chem , vol.10 , Issue.8 , pp. 658-674
    • Bell, J.M.1    Cameron, F.K.2
  • 34
    • 34347098155 scopus 로고
    • The time law of the capillary rise of liquids
    • Lucas R. The time law of the capillary rise of liquids. Colloid Polym. Sci. 23(1), 15-22 (1918
    • (1918) Colloid Polym. Sci , vol.23 , Issue.1 , pp. 15-22
    • Lucas, R.1
  • 35
    • 34548193292 scopus 로고
    • The dynamics of capillary flow
    • Washburn EW. The dynamics of capillary flow. Phys. Rev. 17(3), 273-283 (1921
    • (1921) Phys. Rev , vol.17 , Issue.3 , pp. 273-283
    • Washburn, E.W.1
  • 36
    • 33644505183 scopus 로고    scopus 로고
    • The physics of paper
    • DOI 10.1088/0034-4885/69/3/R03, PII S0034488506647118
    • Alava M, Niskanen K. The physics of paper. Rep. Prog. Phys. 69(3), 669-723 (2006 (Pubitemid 43306356)
    • (2006) Reports on Progress in Physics , vol.69 , Issue.3 , pp. 669-723
    • Alava, M.1    Niskanen, K.2
  • 40
    • 74249119477 scopus 로고    scopus 로고
    • Imbibition in porous membranes of complex shape: Quasi-stationary flow in thin rectangular segments
    • Mendez S, Fenton EM, Gallegos GR et al. Imbibition in porous membranes of complex shape: Quasi-stationary flow in thin rectangular segments. Langmuir 26(2), 1380-1385 (2010
    • (2010) Langmuir , vol.26 , Issue.2 , pp. 1380-1385
    • Mendez, S.1    Fenton, E.M.2    Gallegos, G.R.3
  • 41
    • 84881062373 scopus 로고    scopus 로고
    • Dissolvable fluidic time delays for programming multi-step assays in instrument-free paper diagnostics
    • Lutz B, Liang T, Fu E, Ramachandran S, Kauffman P, Yager P. Dissolvable fluidic time delays for programming multi-step assays in instrument-free paper diagnostics. Lab Chip 13(14), 2840-2847 (2013
    • (2013) Lab Chip , vol.13 , Issue.14 , pp. 2840-2847
    • Lutz, B.1    Liang, T.2    Fu, E.3    Ramachandran, S.4    Kauffman, P.5    Yager, P.6
  • 42
    • 77952537539 scopus 로고    scopus 로고
    • Metering the capillary-driven flow of fluids in paper-based microfluidic devices
    • Noh N, Phillips ST. Metering the capillary-driven flow of fluids in paper-based microfluidic devices. Anal. Chem. 82(10), 4181-4187 (2010
    • (2010) Anal. Chem , vol.82 , Issue.10 , pp. 4181-4187
    • Noh, N.1    Phillips, S.T.2
  • 43
    • 84864266777 scopus 로고    scopus 로고
    • A fluidic diode, valves, and a sequential-loading circuit fabricated on layered paper
    • Chen H, Cogswell J, Anagnostopoulos C, Faghri M. A fluidic diode, valves, and a sequential-loading circuit fabricated on layered paper. Lab Chip 12(16), 2909-2913 (2012
    • (2012) Lab Chip , vol.12 , Issue.16 , pp. 2909-2913
    • Chen, H.1    Cogswell, J.2    Anagnostopoulos, C.3    Faghri, M.4
  • 44
    • 84881176762 scopus 로고    scopus 로고
    • An inkjet-printed electrowetting valve for paper-fluidic sensors
    • Koo C, He F, Nugen S. An inkjet-printed electrowetting valve for paper-fluidic sensors. Analyst 138(17), 4998-5004 (2013
    • (2013) Analyst , vol.138 , Issue.17 , pp. 4998-5004
    • Koo, C.1    He, F.2    Nugen, S.3
  • 45
    • 84878641593 scopus 로고    scopus 로고
    • Magnetic timing valves for fluid control in paper-based microfluidics
    • Li X, Zwanenburg P, Liu X. Magnetic timing valves for fluid control in paper-based microfluidics. Lab Chip 13(13), 2609-2614 (2013
    • (2013) Lab Chip , vol.13 , Issue.13 , pp. 2609-2614
    • Li, X.1    Zwanenburg, P.2    Liu, X.3
  • 46
    • 77952426867 scopus 로고    scopus 로고
    • Progress in patterned paper sizing for fabrication of paper-based microfluidic sensors
    • Li X, Tian JF, Shen W. Progress in patterned paper sizing for fabrication of paper-based microfluidic sensors. Cellulose 17(3), 649-659 (2010
    • (2010) Cellulose , vol.17 , Issue.3 , pp. 649-659
    • Li, X.1    Tian, J.F.2    Shen, W.3
  • 47
    • 77956328100 scopus 로고    scopus 로고
    • Programmable diagnostic devices made from paper and tape
    • Martinez AW, Phillips ST, Nie ZH et al. Programmable diagnostic devices made from paper and tape. Lab Chip 10(19), 2499-2504 (2010
    • (2010) Lab Chip , vol.10 , Issue.19 , pp. 2499-2504
    • Martinez, A.W.1    Phillips, S.T.2    Nie, Z.H.3
  • 49
    • 84877332711 scopus 로고    scopus 로고
    • Paper-based SlipPAD for high-Throughput chemical sensing
    • Liu H, Li X, Crooks RM. Paper-based SlipPAD for high-Throughput chemical sensing. Anal. Chem. 85(9), 4263-4267 (2013
    • (2013) Anal. Chem , vol.85 , Issue.9 , pp. 4263-4267
    • Liu, H.1    Li, X.2    Crooks, R.M.3
  • 50
    • 84858315509 scopus 로고    scopus 로고
    • Two-dimensional paper networks: Programmable fluidic disconnects for multi-step processes in shaped paper
    • Lutz BR, Trinh P, Ball C, Fu E, Yager P. Two-dimensional paper networks: Programmable fluidic disconnects for multi-step processes in shaped paper. Lab Chip 11(24), 4274-4278 (2011
    • (2011) Lab Chip , vol.11 , Issue.24 , pp. 4274-4278
    • Lutz, B.R.1    Trinh, P.2    Ball, C.3    Fu, E.4    Yager, P.5
  • 51
    • 84867299061 scopus 로고    scopus 로고
    • Controlled release of dry reagents in porous media for tunable temporal and spatial distribution upon rehydration
    • Fridley GE, Le HQ, Fu E, Yager P. Controlled release of dry reagents in porous media for tunable temporal and spatial distribution upon rehydration. Lab Chip 12(21), 4321-4327 (2012
    • (2012) Lab Chip , vol.12 , Issue.21 , pp. 4321-4327
    • Fridley, G.E.1    Le, H.Q.2    Fu, E.3    Yager, P.4
  • 52
    • 57849115714 scopus 로고    scopus 로고
    • Lateral flow (immuno)assay: Its strengths, weaknesses, opportunities and threats. A literature survey
    • DOI 10.1007/s00216-008-2287-2
    • Posthuma-Trumpie G, Korf J, Amerongen v. lateral flow (immuno)assay: Its strengths, weaknesses, opportunities and threats. A literature survey. Anal. Bioanal. Chem. 393(2), 569-582 (2009 (Pubitemid 50238446)
    • (2009) Analytical and Bioanalytical Chemistry , vol.393 , Issue.2 , pp. 569-582
    • Posthuma-Trumpie, G.A.1    Korf, J.2    Van Amerongen, A.3
  • 53
    • 58149512870 scopus 로고    scopus 로고
    • Development of enzyme-based bar code-style lateral-flow assay for hydrogen peroxide determination
    • Fung KK, Chan CPY, Renneberg R. Development of enzyme-based bar code-style lateral-flow assay for hydrogen peroxide determination. Anal. Chim. Acta 634(1), 89-95 (2009
    • (2009) Anal. Chim. Acta , vol.634 , Issue.1 , pp. 89-95
    • Fung, K.K.1    Chan, C.P.Y.2    Renneberg, R.3
  • 54
    • 0027457622 scopus 로고
    • One-step competitive immunochromatographic assay for semiquantitative determination of lipoprotein(a) in plasma
    • Lou SC, Patel C, Ching SF, Gordon J. One-step competitive immunochromatographic assay for semiquantitative determination of lipoprotein A in plasma. Clin. Chem. 39(4), 619-624 (1993 (Pubitemid 23118311)
    • (1993) Clinical Chemistry , vol.39 , Issue.4 , pp. 619-624
    • Lou, S.C.1    Patel, C.2    Ching, S.3    Gordon, J.4
  • 55
    • 0035924122 scopus 로고    scopus 로고
    • Semiquantitative, bar code version of immunochromatographic assay system for human serum albumin as model analyte
    • Cho JH, Paek SH. Semiquantitative, bar code version of immunochromatographic assay system for human serum albumin as model analyte. Biotechnol. Bioeng. 75(6), 725-732 (2001
    • (2001) Biotechnol. Bioeng , vol.75 , Issue.6 , pp. 725-732
    • Cho, J.H.1    Paek, S.H.2
  • 56
    • 44149123760 scopus 로고    scopus 로고
    • InfectCheck CRP barcode-style lateral flow assay for semi-quantitative detection of C-reactive protein in distinguishing between bacterial and viral infections
    • Leung W, Chan CP, Rainer TH, Ip M, Cautherley GWH, Renneberg R. InfectCheck CRP barcode-style lateral flow assay for semi-quantitative detection of C-reactive protein in distinguishing between bacterial and viral infections. J. Immunol. Methods 336(1), 30-36 (2008
    • (2008) J. Immunol. Methods , vol.336 , Issue.1 , pp. 30-36
    • Leung, W.1    Chan, C.P.2    Rainer, T.H.3    Ip, M.4    Cautherley, G.W.H.5    Renneberg, R.6
  • 57
    • 84871031419 scopus 로고    scopus 로고
    • Quantifying analytes in paper-based microfluidic devices without using external electronic readers
    • Lewis GG, DiTucci MJ, Phillips ST. Quantifying analytes in paper-based microfluidic devices without using external electronic readers. Angew. Chem. Int. Ed. Engl. 51(51), 12707-12710 (2012
    • (2012) Angew. Chem. Int. Ed. Engl , vol.51 , Issue.51 , pp. 12707-12710
    • Lewis, G.G.1    DiTucci, M.J.2    Phillips, S.T.3
  • 58
    • 0022098604 scopus 로고
    • Enzyme immunochromatography-A quantitative immunoassay requiring no instrumentation
    • Zuk RF, Ginsberg VK, Houts T et al. Enzyme immunochromatography-A quantitative immunoassay requiring no instrumentation. Clin. Chem. 31(7), 1144-1150 (1985
    • (1985) Clin. Chem , vol.31 , Issue.7 , pp. 1144-1150
    • Zuk, R.F.1    Ginsberg, V.K.2    Houts, T.3
  • 60
    • 84878040377 scopus 로고    scopus 로고
    • Simple, distance-based measurement for paper analytical devices
    • Cate DM, Dungchai W, Cunningham JC, Volckens J, Henry CS. Simple, distance-based measurement for paper analytical devices. Lab Chip 13(12), 2397-2404 (2013
    • (2013) Lab Chip , vol.13 , Issue.12 , pp. 2397-2404
    • Cate, D.M.1    Dungchai, W.2    Cunningham, J.C.3    Volckens, J.4    Henry, C.S.5
  • 61
    • 84861073325 scopus 로고    scopus 로고
    • Recent advances in mobile technology benefit global health, research, and care
    • Hampton T. Recent advances in mobile technology benefit global health, research, and care. JAMA 307(19), 2013-2014 (2012
    • (2012) JAMA , vol.307 , Issue.19 , pp. 2013-2014
    • Hampton, T.1
  • 62
    • 84873460695 scopus 로고    scopus 로고
    • Transforming global health with mobile technologies and social enterprises global health and innovation conference
    • Kayingo G. Transforming global health with mobile technologies and social enterprises global health and innovation conference. Yale J. Biol. Med. 85(3), 424-426 (2012
    • (2012) Yale J. Biol. Med , vol.85 , Issue.3 , pp. 424-426
    • Kayingo, G.1
  • 63
    • 43949138608 scopus 로고    scopus 로고
    • Simple telemedicine for developing regions: Camera phones and paper-based microfluidic devices for real-time, off-site diagnosis
    • DOI 10.1021/ac800112r
    • Martinez AW, Phillips ST, Carrilho E, Thomas SW, Sindi H, Whitesides GM. Simple telemedicine for developing regions: Camera phones and paper-based microfluidic devices for real-Time, off-site diagnosis. Anal. Chem. 80(10), 3699-3707 (2008 (Pubitemid 351705870)
    • (2008) Analytical Chemistry , vol.80 , Issue.10 , pp. 3699-3707
    • Martinez, A.W.1    Phillips, S.T.2    Carrilho, E.3    Thomas III, S.W.4    Sindi, H.5    Whitesides, G.M.6
  • 66
    • 78650410499 scopus 로고    scopus 로고
    • Cost-effective and compact wide-field fluorescent imaging on a cell-phone
    • Zhu HY, Yaglidere O, Su TW, Tseng D, Ozcan A. Cost-effective and compact wide-field fluorescent imaging on a cell-phone. Lab Chip 11(2), 315-322 (2011
    • (2011) Lab Chip , vol.11 , Issue.2 , pp. 315-322
    • Zhu, H.Y.1    Yaglidere, O.2    Su, T.W.3    Tseng, D.4    Ozcan, A.5
  • 68
    • 84874899355 scopus 로고    scopus 로고
    • A personalized food allergen testing platform on a cellphone
    • Coskun AF, Wong J, Khodadadi D, Nagi R, Tey A, Ozcan A. A personalized food allergen testing platform on a cellphone. Lab Chip 13(4), 636-640 (2013
    • (2013) Lab Chip , vol.13 , Issue.4 , pp. 636-640
    • Coskun, A.F.1    Wong, J.2    Khodadadi, D.3    Nagi, R.4    Tey, A.5    Ozcan, A.6
  • 70
    • 84863294130 scopus 로고    scopus 로고
    • Paper-based electrochemical sensing platform with integral battery and electrochromic read-out
    • Liu H, Crooks RM. Paper-based electrochemical sensing platform with integral battery and electrochromic read-out. Anal. Chem. 84(5), 2528-2532 (2012
    • (2012) Anal. Chem , vol.84 , Issue.5 , pp. 2528-2532
    • Liu, H.1    Crooks, R.M.2
  • 71
    • 84860363132 scopus 로고    scopus 로고
    • Fluidic batteries in paper-based microfluidic devices
    • Thom NK, Yeung K, Pillion MB, Phillips ST. Fluidic batteries in paper-based microfluidic devices. Lab Chip 12(10), 1768-1770 (2012
    • (2012) Lab Chip , vol.12 , Issue.10 , pp. 1768-1770
    • Thom, N.K.1    Yeung, K.2    Pillion, M.B.3    Phillips, S.T.4
  • 73
    • 84864370706 scopus 로고    scopus 로고
    • Embedded adaptive optics for ubiquitous lab-on-A-chip readout on intact cell phones
    • Preechaburana P, Suska A, Filippini D. Embedded adaptive optics for ubiquitous lab-on-A-chip readout on intact cell phones. Sensors (Basel) 12(7), 8586-8600 (2012
    • (2012) Sensors (Basel , vol.12 , Issue.7 , pp. 8586-8600
    • Preechaburana, P.1    Suska, A.2    Filippini, D.3
  • 74
    • 84855933243 scopus 로고    scopus 로고
    • A disposable, integrated loop-mediated isothermal amplification cassette with thermally actuated valves
    • Liu C, Mauk MG, Bau HH. A disposable, integrated loop-mediated isothermal amplification cassette with thermally actuated valves. Microfluid. Nanofluidics 11(2), 209-220 (2011
    • (2011) Microfluid. Nanofluidics , vol.11 , Issue.2 , pp. 209-220
    • Liu, C.1    Mauk, M.G.2    Bau, H.H.3
  • 75
    • 79955809939 scopus 로고    scopus 로고
    • A simple, inexpensive device for nucleic acid amplification without electricity-Toward instrument-free molecular diagnostics in low-resource settings
    • LaBarre P, Hawkins KR, Gerlach J et al. A simple, inexpensive device for nucleic acid amplification without electricity-Toward instrument-free molecular diagnostics in low-resource settings. Plos ONE 6(5), e19738 (2011
    • (2011) Plos ONE , vol.6 , Issue.5
    • LaBarre, P.1    Hawkins, K.R.2    Gerlach, J.3
  • 76
    • 82555176812 scopus 로고    scopus 로고
    • A low cost point-of-care viscous sample preparation device for molecular diagnosis in the developing world; an example of microfluidic origami
    • Govindarajan AV, Ramachandran S, Vigil GD, Yager P, Boehringer KF. A low cost point-of-care viscous sample preparation device for molecular diagnosis in the developing world; an example of microfluidic origami. Lab Chip 12(1), 174-181 (2012
    • (2012) Lab Chip , vol.12 , Issue.1 , pp. 174-181
    • Govindarajan, A.V.1    Ramachandran, S.2    Vigil, G.D.3    Yager, P.4    Boehringer, K.F.5
  • 77
    • 77957675473 scopus 로고    scopus 로고
    • Microfluidics without pumps: Reinventing the T-sensor and H-filter in paper networks
    • Osborn JL, Lutz B, Fu E, Kauffman P, Stevens DY, Yager P. Microfluidics without pumps: Reinventing the T-sensor and H-filter in paper networks. Lab Chip 10(20), 2659-2665 (2010
    • (2010) Lab Chip , vol.10 , Issue.20 , pp. 2659-2665
    • Osborn, J.L.1    Lutz, B.2    Fu, E.3    Kauffman, P.4    Stevens, D.Y.5    Yager, P.6
  • 78
    • 84876238935 scopus 로고    scopus 로고
    • Multifunctional analytical platform on a paper strip: Separation, preconcentration, and subattomolar detection
    • Abbas A, Brimer A, Slocik JM, Tian LM, Naik RR, Singamaneni S. Multifunctional analytical platform on a paper strip: Separation, preconcentration, and subattomolar detection. Anal. Chem. 85(8), 3977-3983 (2013
    • (2013) Anal. Chem , vol.85 , Issue.8 , pp. 3977-3983
    • Abbas, A.1    Brimer, A.2    Slocik, J.M.3    Tian, L.M.4    Naik, R.R.5    Singamaneni, S.6
  • 79
    • 84880166077 scopus 로고    scopus 로고
    • Phase-switching depolymerizable poly(carbamate) oligomers for signal amplification in quantitative time-based assays
    • Lewis G, Robbins J, Phillips S. Phase-switching depolymerizable poly(carbamate) oligomers for signal amplification in quantitative time-based assays. Macromolecules 46, 5177-5183 (2013
    • (2013) Macromolecules , vol.46 , pp. 5177-5183
    • Lewis, G.1    Robbins, J.2    Phillips, S.3
  • 80
    • 84864706880 scopus 로고    scopus 로고
    • A paper and plastic device for performing recombinase polymerase amplification of HIV DNA
    • Rohrman BA, Richards-Kortum RR. A paper and plastic device for performing recombinase polymerase amplification of HIV DNA. Lab Chip 12(17), 3082-3088 (2012
    • (2012) Lab Chip , vol.12 , Issue.17 , pp. 3082-3088
    • Rohrman, B.A.1    Richards-Kortum, R.R.2
  • 81
    • 84864718103 scopus 로고    scopus 로고
    • 3D origami-based multifunction-integrated immunodevice: Low-cost and multiplexed sandwich chemiluminescence immunoassay on microfluidic paper-based analytical device
    • Ge L, Wang SM, Song XR, Ge SG, Yu JH. 3D origami-based multifunction-integrated immunodevice: Low-cost and multiplexed sandwich chemiluminescence immunoassay on microfluidic paper-based analytical device. Lab Chip 12(17), 3150-3158 (2012
    • (2012) Lab Chip , vol.12 , Issue.17 , pp. 3150-3158
    • Ge, L.1    Wang, S.M.2    Song, X.R.3    Ge, S.G.4    Yu, J.H.5
  • 82
    • 84881400470 scopus 로고    scopus 로고
    • A 3D origami multiple electrochemiluminescence immunodevice based on a porous silver-paper electrode and multi-labeled nanoporous gold-carbon spheres
    • Li W, Li L, Ge S et al. A 3D origami multiple electrochemiluminescence immunodevice based on a porous silver-paper electrode and multi-labeled nanoporous gold-carbon spheres. Chem. Commun. (Camb.) 49(70), 7687-7689 (2013
    • (2013) Chem. Commun. (Camb , vol.49 , Issue.70 , pp. 7687-7689
    • Li, W.1    Li, L.2    Ge, S.3
  • 83
    • 84875452165 scopus 로고    scopus 로고
    • 3D microfluidic origami electrochemiluminescence immunodevice for sensitive point-of-care testing of carcinoma antigen 125
    • Wang S, Ge L, Yan M et al. 3D microfluidic origami electrochemiluminescence immunodevice for sensitive point-of-care testing of carcinoma antigen 125. Sens. Actuators B Chem. 176, 1-8 (2013
    • (2013) Sens. Actuators B Chem , vol.176 , pp. 1-8
    • Wang, S.1    Ge, L.2    Yan, M.3
  • 84
    • 79955777583 scopus 로고    scopus 로고
    • Integrated microfluidic devices in diagnostics
    • Becker H. Integrated microfluidic devices in diagnostics. Med. Device Technol. 1(4), (2010
    • (2010) Med. Device Technol , vol.1 , Issue.4
    • Becker, H.1
  • 85
    • 52549116513 scopus 로고    scopus 로고
    • Sample preparation: The weak link in microfluidics-based biodetection
    • Mariella R Jr. Sample preparation: The weak link in microfluidics-based biodetection. Biomed. Microdevices 10(6), 777-784 (2008
    • (2008) Biomed. Microdevices , vol.10 , Issue.6 , pp. 777-784
    • Mariella Jr., R.1
  • 86
    • 33746832078 scopus 로고    scopus 로고
    • Can the ubiquitous power of mobile phones be used to improve health outcomes in developing countries? Global
    • Kaplan WA. Can the ubiquitous power of mobile phones be used to improve health outcomes in developing countries? Global. Health 2(9) (2006
    • (2006) Health , vol.2 , pp. 9
    • Kaplan, W.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.