메뉴 건너뛰기




Volumn 29, Issue 1, 2014, Pages 1-6

Modular taper junction corrosion and failure: How to approach a recalled total hip arthroplasty implant

Author keywords

Corrosion; Modular junction corrosion; Modular stem; THA

Indexed keywords

CHROMIUM; COBALT;

EID: 84889083786     PISSN: 08835403     EISSN: 15328406     Source Type: Journal    
DOI: 10.1016/j.arth.2013.08.026     Document Type: Review
Times cited : (83)

References (40)
  • 1
    • 80052888595 scopus 로고    scopus 로고
    • Perspectives in managing an implant recall: revision of 94 Durom Metasul acetabular components
    • Ng V.Y., Arnott L., McShane M.A., 1.Ng V.Y., Arnott L., McShane M.A. Perspectives in managing an implant recall: revision of 94 Durom Metasul acetabular components. J Bone Joint Surg Am 2011, 93(17):e100.
    • (2011) J Bone Joint Surg Am , vol.93 , Issue.17
    • Ng, V.Y.1    Arnott, L.2    McShane, M.A.3    Ng, V.Y.4    Arnott, L.5    McShane, M.A.6
  • 2
    • 84866387757 scopus 로고    scopus 로고
    • The articular surface replacement implant recall: a United Kingdom district hospital experience
    • Whitwell G.S., Shine A., Young S.K. The articular surface replacement implant recall: a United Kingdom district hospital experience. Hip Int 2012, 22:362.
    • (2012) Hip Int , vol.22 , pp. 362
    • Whitwell, G.S.1    Shine, A.2    Young, S.K.3
  • 3
    • 84889096770 scopus 로고    scopus 로고
    • U.S. Food and Drug Administration Medical Device Recalls. (Accessed January 9, 2013, at).
    • U.S. Food and Drug Administration Medical Device Recalls. (Accessed January 9, 2013, at .). http://www.fda.gov/MedicalDevices/Safety/ListofRecalls/default.htm.
  • 4
    • 0023833269 scopus 로고
    • Tissue reaction to implant corrosion in 38 internal fixation devices
    • Thomas K.A., Cook S.D., Harding A.F., et al. Tissue reaction to implant corrosion in 38 internal fixation devices. Orthopedics 1988, 11:441.
    • (1988) Orthopedics , vol.11 , pp. 441
    • Thomas, K.A.1    Cook, S.D.2    Harding, A.F.3
  • 6
    • 0010431881 scopus 로고
    • The recent history of corrosion in metal used for internal fixation
    • Cater W.H., Hicks J.H. The recent history of corrosion in metal used for internal fixation. Lancet 1956, 271:871.
    • (1956) Lancet , vol.271 , pp. 871
    • Cater, W.H.1    Hicks, J.H.2
  • 7
    • 0035989725 scopus 로고    scopus 로고
    • Pitting, crevice and galvanic corrosion of REX stainless-steel/CoCr orthopedic implant material
    • Reclaru L., Lerf R., Eschler P.Y., et al. Pitting, crevice and galvanic corrosion of REX stainless-steel/CoCr orthopedic implant material. Biomaterials 2002, 23:3479.
    • (2002) Biomaterials , vol.23 , pp. 3479
    • Reclaru, L.1    Lerf, R.2    Eschler, P.Y.3
  • 8
    • 0019620768 scopus 로고
    • Investigations on the galvanic corrosion of multialloy total hip prostheses
    • Lucas L.C., Buchanan R.A., Lemons J.E. Investigations on the galvanic corrosion of multialloy total hip prostheses. J Biomed Mater Res 1981, 15:731.
    • (1981) J Biomed Mater Res , vol.15 , pp. 731
    • Lucas, L.C.1    Buchanan, R.A.2    Lemons, J.E.3
  • 9
    • 0029257098 scopus 로고
    • Fretting corrosion accelerates crevice corrosion of modular hip tapers
    • Brown S.A., Flemming C.A., Kawalec J.S., et al. Fretting corrosion accelerates crevice corrosion of modular hip tapers. J Appl Biomater 1995, 6:19.
    • (1995) J Appl Biomater , vol.6 , pp. 19
    • Brown, S.A.1    Flemming, C.A.2    Kawalec, J.S.3
  • 11
    • 0019644507 scopus 로고
    • Crevice and fretting corrosion of stainless-steel plates and screws
    • Brown S.A., Simpson J.P. Crevice and fretting corrosion of stainless-steel plates and screws. J Biomed Mater Res 1981, 15:867.
    • (1981) J Biomed Mater Res , vol.15 , pp. 867
    • Brown, S.A.1    Simpson, J.P.2
  • 12
    • 84861222802 scopus 로고    scopus 로고
    • Fretting corrosion of CoCrMo and Ti6Al4V interfaces
    • Swaminathan V., Gilbert J.L. Fretting corrosion of CoCrMo and Ti6Al4V interfaces. Biomaterials 2012, 33:5487.
    • (2012) Biomaterials , vol.33 , pp. 5487
    • Swaminathan, V.1    Gilbert, J.L.2
  • 13
    • 0030453223 scopus 로고    scopus 로고
    • Crevice corrosion of cemented titanium alloy stems in total hip replacements
    • Willert H.G., Broback L.G., Buchhorn G.H., et al. Crevice corrosion of cemented titanium alloy stems in total hip replacements. Clin Orthop Relat Res 1996, 51.
    • (1996) Clin Orthop Relat Res , pp. 51
    • Willert, H.G.1    Broback, L.G.2    Buchhorn, G.H.3
  • 14
    • 57349178387 scopus 로고    scopus 로고
    • Fretting crevice corrosion of stainless steel stem-CoCr femoral head connections: comparisons of materials, initial moisture, and offset length
    • Gilbert J.L., Mehta M., Pinder B. Fretting crevice corrosion of stainless steel stem-CoCr femoral head connections: comparisons of materials, initial moisture, and offset length. J Biomed Mater Res B Appl Biomater 2009, 88:162.
    • (2009) J Biomed Mater Res B Appl Biomater , vol.88 , pp. 162
    • Gilbert, J.L.1    Mehta, M.2    Pinder, B.3
  • 15
    • 0017516206 scopus 로고
    • Crevice corrosion in orthopedic implant metals
    • Levine D.L., Staehle R.W. Crevice corrosion in orthopedic implant metals. J Biomed Mater Res 1977, 11:553.
    • (1977) J Biomed Mater Res , vol.11 , pp. 553
    • Levine, D.L.1    Staehle, R.W.2
  • 16
    • 0020215897 scopus 로고
    • Susceptibility of surgical cobalt-base alloy to pitting corrosion
    • Lucas L.C., Buchanan R.A., Lemons J.E., et al. Susceptibility of surgical cobalt-base alloy to pitting corrosion. J Biomed Mater Res 1982, 16:799.
    • (1982) J Biomed Mater Res , vol.16 , pp. 799
    • Lucas, L.C.1    Buchanan, R.A.2    Lemons, J.E.3
  • 17
    • 0028343874 scopus 로고
    • Intergranular corrosion-fatigue failure of cobalt-alloy femoral stems. A failure analysis of two implants
    • Gilbert J.L., Buckley C.A., Jacobs J.J., et al. Intergranular corrosion-fatigue failure of cobalt-alloy femoral stems. A failure analysis of two implants. J Bone Joint Surg Am 1994, 76:110.
    • (1994) J Bone Joint Surg Am , vol.76 , pp. 110
    • Gilbert, J.L.1    Buckley, C.A.2    Jacobs, J.J.3
  • 18
    • 72349090736 scopus 로고    scopus 로고
    • Metal release and corrosion effects of modular neck total hip arthroplasty
    • Kretzer J.P., Jakubowitz E., Krachler M., et al. Metal release and corrosion effects of modular neck total hip arthroplasty. Int Orthop 2009, 33:1531.
    • (2009) Int Orthop , vol.33 , pp. 1531
    • Kretzer, J.P.1    Jakubowitz, E.2    Krachler, M.3
  • 19
    • 70349248399 scopus 로고    scopus 로고
    • Corrosion of a hip stem with a modular neck taper junction: a retrieval study of 16 cases
    • Kop A.M., Swarts E. Corrosion of a hip stem with a modular neck taper junction: a retrieval study of 16 cases. J Arthroplasty 2009, 24:1019.
    • (2009) J Arthroplasty , vol.24 , pp. 1019
    • Kop, A.M.1    Swarts, E.2
  • 20
    • 84867555929 scopus 로고    scopus 로고
    • Corrosion at the head-neck taper as a cause for adverse local tissue reactions after total hip arthroplasty
    • Cooper H.J., Della Valle C.J., Berger R.A., et al. Corrosion at the head-neck taper as a cause for adverse local tissue reactions after total hip arthroplasty. J Bone Joint Surg Am 2012, 94:1655.
    • (2012) J Bone Joint Surg Am , vol.94 , pp. 1655
    • Cooper, H.J.1    Della Valle, C.J.2    Berger, R.A.3
  • 21
    • 84879738471 scopus 로고    scopus 로고
    • Adverse local tissue reaction arising from corrosion at the femoral neck-body junction in a dual-taper stem with a cobalt-chromium modular neck
    • Cooper H.J., Urban R.M., Wixson R.L., et al. Adverse local tissue reaction arising from corrosion at the femoral neck-body junction in a dual-taper stem with a cobalt-chromium modular neck. J Bone Joint Surg Am 2013, 95(10):865.
    • (2013) J Bone Joint Surg Am , vol.95 , Issue.10 , pp. 865
    • Cooper, H.J.1    Urban, R.M.2    Wixson, R.L.3
  • 22
    • 34447503529 scopus 로고    scopus 로고
    • The morse taper junction in modular revision hip replacement
    • Gravius S., Mumme T., Andereya S., et al. The morse taper junction in modular revision hip replacement. Z Orthop Unfall 2007, 145:157.
    • (2007) Z Orthop Unfall , vol.145 , pp. 157
    • Gravius, S.1    Mumme, T.2    Andereya, S.3
  • 23
    • 84863493719 scopus 로고    scopus 로고
    • Corrosion at the neck-stem junction as a cause of metal ion release and pseudotumour formation
    • Gill I.P., Webb J., Sloan K., et al. Corrosion at the neck-stem junction as a cause of metal ion release and pseudotumour formation. J Bone Joint Surg Br 2012, 94:895.
    • (2012) J Bone Joint Surg Br , vol.94 , pp. 895
    • Gill, I.P.1    Webb, J.2    Sloan, K.3
  • 24
    • 84870758359 scopus 로고    scopus 로고
    • Modular femoral neck fracture after primary total hip arthroplasty
    • Sotereanos N.G., Sauber T.J., Tupis T.T. Modular femoral neck fracture after primary total hip arthroplasty. J Arthroplasty 2013, 28:196 e7.
    • (2013) J Arthroplasty , vol.28
    • Sotereanos, N.G.1    Sauber, T.J.2    Tupis, T.T.3
  • 25
    • 77954647496 scopus 로고    scopus 로고
    • Fracture of a modular femoral neck after total hip arthroplasty: a case report
    • Wright G., Sporer S., Urban R., et al. Fracture of a modular femoral neck after total hip arthroplasty: a case report. J Bone Joint Surg Am 2010, 92:1518.
    • (2010) J Bone Joint Surg Am , vol.92 , pp. 1518
    • Wright, G.1    Sporer, S.2    Urban, R.3
  • 26
    • 84864286518 scopus 로고    scopus 로고
    • Proximal component modularity in THA-at what cost? An implant retrieval study
    • Kop A.M., Keogh C., Swarts E. Proximal component modularity in THA-at what cost? An implant retrieval study. Clin Orthop Relat Res 2012, 470:1885.
    • (2012) Clin Orthop Relat Res , vol.470 , pp. 1885
    • Kop, A.M.1    Keogh, C.2    Swarts, E.3
  • 27
    • 84870230937 scopus 로고    scopus 로고
    • The Hip Society: algorithmic approach to diagnosis and management of metal-on-metal arthroplasty
    • Lombardi A.V., Barrack R.L., Berend K.R., et al. The Hip Society: algorithmic approach to diagnosis and management of metal-on-metal arthroplasty. J Bone Joint Surg Br 2012, 94:14.
    • (2012) J Bone Joint Surg Br , vol.94 , pp. 14
    • Lombardi, A.V.1    Barrack, R.L.2    Berend, K.R.3
  • 28
    • 84872677481 scopus 로고    scopus 로고
    • Steinman pin technique for the removal of well-fixed femoral stems
    • Shah R.P., Kamath A.F., Saxena V., et al. Steinman pin technique for the removal of well-fixed femoral stems. J Arthroplasty 2013, 28(2):292.
    • (2013) J Arthroplasty , vol.28 , Issue.2 , pp. 292
    • Shah, R.P.1    Kamath, A.F.2    Saxena, V.3
  • 29
    • 80053477869 scopus 로고    scopus 로고
    • Sensitivity and specificity of blood cobalt and chromium metal ions for predicting failure of metal-on-metal hip replacement
    • Hart A.J., Sabah S.A., Bandi A.S., et al. Sensitivity and specificity of blood cobalt and chromium metal ions for predicting failure of metal-on-metal hip replacement. J Bone Joint Surg Br 2011, 93:1308.
    • (2011) J Bone Joint Surg Br , vol.93 , pp. 1308
    • Hart, A.J.1    Sabah, S.A.2    Bandi, A.S.3
  • 30
    • 84889084179 scopus 로고    scopus 로고
    • U.S. Food and Drug Administration Orthopaedic and Rehabilitation Devices Advisory Panel: Metal-on-Metal Hip Implant Systems. (Accessed August 5, 2013, at ).
    • U.S. Food and Drug Administration Orthopaedic and Rehabilitation Devices Advisory Panel: Metal-on-Metal Hip Implant Systems. (Accessed August 5, 2013, at ). http://www.fda.gov/MedicalDevices/ProductsandMedicalProcedures/ImplantsandProsthetics/MetalonMetalHipImplants/ucm241769.htm.
  • 31
    • 10044235250 scopus 로고    scopus 로고
    • Quantitative analysis of macrophage apoptosis vs. necrosis induced by cobalt and chromium ions in vitro
    • Catelas I., Petit A., Vail H., et al. Quantitative analysis of macrophage apoptosis vs. necrosis induced by cobalt and chromium ions in vitro. Biomaterials 2005, 26(15):2441.
    • (2005) Biomaterials , vol.26 , Issue.15 , pp. 2441
    • Catelas, I.1    Petit, A.2    Vail, H.3
  • 32
    • 84878219451 scopus 로고    scopus 로고
    • High survival of modular tapered stems for proximal femoral bone defects at 5 to 10years followup
    • Van Houwelingen A.P., Duncan C.P., Masri B.A., et al. High survival of modular tapered stems for proximal femoral bone defects at 5 to 10years followup. Clin Orthop Relat Res Feb 2013, 471(2):454.
    • (2013) Clin Orthop Relat Res , vol.471 , Issue.2 , pp. 454
    • Van Houwelingen, A.P.1    Duncan, C.P.2    Masri, B.A.3
  • 33
    • 84870758359 scopus 로고    scopus 로고
    • Modular femoral neck fracture after primary total hip arthroplasty
    • Sotereanos N.G., Sauber T.J., Tupis T.T. Modular femoral neck fracture after primary total hip arthroplasty. J Arthroplasty Jan 2013, 28(1):196 e197.
    • (2013) J Arthroplasty , vol.28 , Issue.1
    • Sotereanos, N.G.1    Sauber, T.J.2    Tupis, T.T.3
  • 34
    • 84864002894 scopus 로고    scopus 로고
    • Femoral stem fracture and in vivo corrosion of retrieved modular femoral hips
    • Huot Carlson J.C., Van Citters D.W., Currier J.H., et al. Femoral stem fracture and in vivo corrosion of retrieved modular femoral hips. J Arthroplasty 2012, 27(7):1389 e1381.
    • (2012) J Arthroplasty , vol.27 , Issue.7
    • Huot Carlson, J.C.1    Van Citters, D.W.2    Currier, J.H.3
  • 35
    • 84870766602 scopus 로고    scopus 로고
    • Fracture of the modular femoral neck component in total hip arthroplasty
    • Ellman M.B., Levine B.R. Fracture of the modular femoral neck component in total hip arthroplasty. J Arthroplasty 2013, 28(1):196 e191.
    • (2013) J Arthroplasty , vol.28 , Issue.1
    • Ellman, M.B.1    Levine, B.R.2
  • 36
    • 78650927177 scopus 로고    scopus 로고
    • Fracture of cementless femoral stems at the mid-stem junction in modular revision hip arthroplasty systems
    • Lakstein D., Eliaz N., Levi O., et al. Fracture of cementless femoral stems at the mid-stem junction in modular revision hip arthroplasty systems. J Bone Joint Surg Am 2011, 93(1):57.
    • (2011) J Bone Joint Surg Am , vol.93 , Issue.1 , pp. 57
    • Lakstein, D.1    Eliaz, N.2    Levi, O.3
  • 37
    • 79955968561 scopus 로고    scopus 로고
    • Analyses of prosthesis stem failures in noncemented modular hip revision prostheses
    • Efe T., Schmitt J. Analyses of prosthesis stem failures in noncemented modular hip revision prostheses. J Arthroplasty 2011, 26(4):665 e667.
    • (2011) J Arthroplasty , vol.26 , Issue.4
    • Efe, T.1    Schmitt, J.2
  • 39
    • 77249158849 scopus 로고    scopus 로고
    • Modular titanium alloy neck adapter failures in hip replacement - failure mode analysis and influence of implant material
    • Grupp T.M., Weik T., Bloemer W., et al. Modular titanium alloy neck adapter failures in hip replacement - failure mode analysis and influence of implant material. BMC Musculoskelet Disord 2010, 11:3.
    • (2010) BMC Musculoskelet Disord , vol.11 , pp. 3
    • Grupp, T.M.1    Weik, T.2    Bloemer, W.3
  • 40
    • 77954654247 scopus 로고    scopus 로고
    • Corrosion-induced fracture of a double-modular hip prosthesis: a case report
    • Atwood S.A., Patten E.W., et al. Corrosion-induced fracture of a double-modular hip prosthesis: a case report. J Bone Joint Surg Am 2010, 92(6):1522.
    • (2010) J Bone Joint Surg Am , vol.92 , Issue.6 , pp. 1522
    • Atwood, S.A.1    Patten, E.W.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.