-
1
-
-
80052888595
-
Perspectives in managing an implant recall: revision of 94 Durom Metasul acetabular components
-
Ng V.Y., Arnott L., McShane M.A., 1.Ng V.Y., Arnott L., McShane M.A. Perspectives in managing an implant recall: revision of 94 Durom Metasul acetabular components. J Bone Joint Surg Am 2011, 93(17):e100.
-
(2011)
J Bone Joint Surg Am
, vol.93
, Issue.17
-
-
Ng, V.Y.1
Arnott, L.2
McShane, M.A.3
Ng, V.Y.4
Arnott, L.5
McShane, M.A.6
-
2
-
-
84866387757
-
The articular surface replacement implant recall: a United Kingdom district hospital experience
-
Whitwell G.S., Shine A., Young S.K. The articular surface replacement implant recall: a United Kingdom district hospital experience. Hip Int 2012, 22:362.
-
(2012)
Hip Int
, vol.22
, pp. 362
-
-
Whitwell, G.S.1
Shine, A.2
Young, S.K.3
-
3
-
-
84889096770
-
-
U.S. Food and Drug Administration Medical Device Recalls. (Accessed January 9, 2013, at).
-
U.S. Food and Drug Administration Medical Device Recalls. (Accessed January 9, 2013, at .). http://www.fda.gov/MedicalDevices/Safety/ListofRecalls/default.htm.
-
-
-
-
4
-
-
0023833269
-
Tissue reaction to implant corrosion in 38 internal fixation devices
-
Thomas K.A., Cook S.D., Harding A.F., et al. Tissue reaction to implant corrosion in 38 internal fixation devices. Orthopedics 1988, 11:441.
-
(1988)
Orthopedics
, vol.11
, pp. 441
-
-
Thomas, K.A.1
Cook, S.D.2
Harding, A.F.3
-
6
-
-
0010431881
-
The recent history of corrosion in metal used for internal fixation
-
Cater W.H., Hicks J.H. The recent history of corrosion in metal used for internal fixation. Lancet 1956, 271:871.
-
(1956)
Lancet
, vol.271
, pp. 871
-
-
Cater, W.H.1
Hicks, J.H.2
-
7
-
-
0035989725
-
Pitting, crevice and galvanic corrosion of REX stainless-steel/CoCr orthopedic implant material
-
Reclaru L., Lerf R., Eschler P.Y., et al. Pitting, crevice and galvanic corrosion of REX stainless-steel/CoCr orthopedic implant material. Biomaterials 2002, 23:3479.
-
(2002)
Biomaterials
, vol.23
, pp. 3479
-
-
Reclaru, L.1
Lerf, R.2
Eschler, P.Y.3
-
8
-
-
0019620768
-
Investigations on the galvanic corrosion of multialloy total hip prostheses
-
Lucas L.C., Buchanan R.A., Lemons J.E. Investigations on the galvanic corrosion of multialloy total hip prostheses. J Biomed Mater Res 1981, 15:731.
-
(1981)
J Biomed Mater Res
, vol.15
, pp. 731
-
-
Lucas, L.C.1
Buchanan, R.A.2
Lemons, J.E.3
-
9
-
-
0029257098
-
Fretting corrosion accelerates crevice corrosion of modular hip tapers
-
Brown S.A., Flemming C.A., Kawalec J.S., et al. Fretting corrosion accelerates crevice corrosion of modular hip tapers. J Appl Biomater 1995, 6:19.
-
(1995)
J Appl Biomater
, vol.6
, pp. 19
-
-
Brown, S.A.1
Flemming, C.A.2
Kawalec, J.S.3
-
11
-
-
0019644507
-
Crevice and fretting corrosion of stainless-steel plates and screws
-
Brown S.A., Simpson J.P. Crevice and fretting corrosion of stainless-steel plates and screws. J Biomed Mater Res 1981, 15:867.
-
(1981)
J Biomed Mater Res
, vol.15
, pp. 867
-
-
Brown, S.A.1
Simpson, J.P.2
-
12
-
-
84861222802
-
Fretting corrosion of CoCrMo and Ti6Al4V interfaces
-
Swaminathan V., Gilbert J.L. Fretting corrosion of CoCrMo and Ti6Al4V interfaces. Biomaterials 2012, 33:5487.
-
(2012)
Biomaterials
, vol.33
, pp. 5487
-
-
Swaminathan, V.1
Gilbert, J.L.2
-
13
-
-
0030453223
-
Crevice corrosion of cemented titanium alloy stems in total hip replacements
-
Willert H.G., Broback L.G., Buchhorn G.H., et al. Crevice corrosion of cemented titanium alloy stems in total hip replacements. Clin Orthop Relat Res 1996, 51.
-
(1996)
Clin Orthop Relat Res
, pp. 51
-
-
Willert, H.G.1
Broback, L.G.2
Buchhorn, G.H.3
-
14
-
-
57349178387
-
Fretting crevice corrosion of stainless steel stem-CoCr femoral head connections: comparisons of materials, initial moisture, and offset length
-
Gilbert J.L., Mehta M., Pinder B. Fretting crevice corrosion of stainless steel stem-CoCr femoral head connections: comparisons of materials, initial moisture, and offset length. J Biomed Mater Res B Appl Biomater 2009, 88:162.
-
(2009)
J Biomed Mater Res B Appl Biomater
, vol.88
, pp. 162
-
-
Gilbert, J.L.1
Mehta, M.2
Pinder, B.3
-
15
-
-
0017516206
-
Crevice corrosion in orthopedic implant metals
-
Levine D.L., Staehle R.W. Crevice corrosion in orthopedic implant metals. J Biomed Mater Res 1977, 11:553.
-
(1977)
J Biomed Mater Res
, vol.11
, pp. 553
-
-
Levine, D.L.1
Staehle, R.W.2
-
16
-
-
0020215897
-
Susceptibility of surgical cobalt-base alloy to pitting corrosion
-
Lucas L.C., Buchanan R.A., Lemons J.E., et al. Susceptibility of surgical cobalt-base alloy to pitting corrosion. J Biomed Mater Res 1982, 16:799.
-
(1982)
J Biomed Mater Res
, vol.16
, pp. 799
-
-
Lucas, L.C.1
Buchanan, R.A.2
Lemons, J.E.3
-
17
-
-
0028343874
-
Intergranular corrosion-fatigue failure of cobalt-alloy femoral stems. A failure analysis of two implants
-
Gilbert J.L., Buckley C.A., Jacobs J.J., et al. Intergranular corrosion-fatigue failure of cobalt-alloy femoral stems. A failure analysis of two implants. J Bone Joint Surg Am 1994, 76:110.
-
(1994)
J Bone Joint Surg Am
, vol.76
, pp. 110
-
-
Gilbert, J.L.1
Buckley, C.A.2
Jacobs, J.J.3
-
18
-
-
72349090736
-
Metal release and corrosion effects of modular neck total hip arthroplasty
-
Kretzer J.P., Jakubowitz E., Krachler M., et al. Metal release and corrosion effects of modular neck total hip arthroplasty. Int Orthop 2009, 33:1531.
-
(2009)
Int Orthop
, vol.33
, pp. 1531
-
-
Kretzer, J.P.1
Jakubowitz, E.2
Krachler, M.3
-
19
-
-
70349248399
-
Corrosion of a hip stem with a modular neck taper junction: a retrieval study of 16 cases
-
Kop A.M., Swarts E. Corrosion of a hip stem with a modular neck taper junction: a retrieval study of 16 cases. J Arthroplasty 2009, 24:1019.
-
(2009)
J Arthroplasty
, vol.24
, pp. 1019
-
-
Kop, A.M.1
Swarts, E.2
-
20
-
-
84867555929
-
Corrosion at the head-neck taper as a cause for adverse local tissue reactions after total hip arthroplasty
-
Cooper H.J., Della Valle C.J., Berger R.A., et al. Corrosion at the head-neck taper as a cause for adverse local tissue reactions after total hip arthroplasty. J Bone Joint Surg Am 2012, 94:1655.
-
(2012)
J Bone Joint Surg Am
, vol.94
, pp. 1655
-
-
Cooper, H.J.1
Della Valle, C.J.2
Berger, R.A.3
-
21
-
-
84879738471
-
Adverse local tissue reaction arising from corrosion at the femoral neck-body junction in a dual-taper stem with a cobalt-chromium modular neck
-
Cooper H.J., Urban R.M., Wixson R.L., et al. Adverse local tissue reaction arising from corrosion at the femoral neck-body junction in a dual-taper stem with a cobalt-chromium modular neck. J Bone Joint Surg Am 2013, 95(10):865.
-
(2013)
J Bone Joint Surg Am
, vol.95
, Issue.10
, pp. 865
-
-
Cooper, H.J.1
Urban, R.M.2
Wixson, R.L.3
-
22
-
-
34447503529
-
The morse taper junction in modular revision hip replacement
-
Gravius S., Mumme T., Andereya S., et al. The morse taper junction in modular revision hip replacement. Z Orthop Unfall 2007, 145:157.
-
(2007)
Z Orthop Unfall
, vol.145
, pp. 157
-
-
Gravius, S.1
Mumme, T.2
Andereya, S.3
-
23
-
-
84863493719
-
Corrosion at the neck-stem junction as a cause of metal ion release and pseudotumour formation
-
Gill I.P., Webb J., Sloan K., et al. Corrosion at the neck-stem junction as a cause of metal ion release and pseudotumour formation. J Bone Joint Surg Br 2012, 94:895.
-
(2012)
J Bone Joint Surg Br
, vol.94
, pp. 895
-
-
Gill, I.P.1
Webb, J.2
Sloan, K.3
-
24
-
-
84870758359
-
Modular femoral neck fracture after primary total hip arthroplasty
-
Sotereanos N.G., Sauber T.J., Tupis T.T. Modular femoral neck fracture after primary total hip arthroplasty. J Arthroplasty 2013, 28:196 e7.
-
(2013)
J Arthroplasty
, vol.28
-
-
Sotereanos, N.G.1
Sauber, T.J.2
Tupis, T.T.3
-
25
-
-
77954647496
-
Fracture of a modular femoral neck after total hip arthroplasty: a case report
-
Wright G., Sporer S., Urban R., et al. Fracture of a modular femoral neck after total hip arthroplasty: a case report. J Bone Joint Surg Am 2010, 92:1518.
-
(2010)
J Bone Joint Surg Am
, vol.92
, pp. 1518
-
-
Wright, G.1
Sporer, S.2
Urban, R.3
-
26
-
-
84864286518
-
Proximal component modularity in THA-at what cost? An implant retrieval study
-
Kop A.M., Keogh C., Swarts E. Proximal component modularity in THA-at what cost? An implant retrieval study. Clin Orthop Relat Res 2012, 470:1885.
-
(2012)
Clin Orthop Relat Res
, vol.470
, pp. 1885
-
-
Kop, A.M.1
Keogh, C.2
Swarts, E.3
-
27
-
-
84870230937
-
The Hip Society: algorithmic approach to diagnosis and management of metal-on-metal arthroplasty
-
Lombardi A.V., Barrack R.L., Berend K.R., et al. The Hip Society: algorithmic approach to diagnosis and management of metal-on-metal arthroplasty. J Bone Joint Surg Br 2012, 94:14.
-
(2012)
J Bone Joint Surg Br
, vol.94
, pp. 14
-
-
Lombardi, A.V.1
Barrack, R.L.2
Berend, K.R.3
-
28
-
-
84872677481
-
Steinman pin technique for the removal of well-fixed femoral stems
-
Shah R.P., Kamath A.F., Saxena V., et al. Steinman pin technique for the removal of well-fixed femoral stems. J Arthroplasty 2013, 28(2):292.
-
(2013)
J Arthroplasty
, vol.28
, Issue.2
, pp. 292
-
-
Shah, R.P.1
Kamath, A.F.2
Saxena, V.3
-
29
-
-
80053477869
-
Sensitivity and specificity of blood cobalt and chromium metal ions for predicting failure of metal-on-metal hip replacement
-
Hart A.J., Sabah S.A., Bandi A.S., et al. Sensitivity and specificity of blood cobalt and chromium metal ions for predicting failure of metal-on-metal hip replacement. J Bone Joint Surg Br 2011, 93:1308.
-
(2011)
J Bone Joint Surg Br
, vol.93
, pp. 1308
-
-
Hart, A.J.1
Sabah, S.A.2
Bandi, A.S.3
-
30
-
-
84889084179
-
-
U.S. Food and Drug Administration Orthopaedic and Rehabilitation Devices Advisory Panel: Metal-on-Metal Hip Implant Systems. (Accessed August 5, 2013, at ).
-
U.S. Food and Drug Administration Orthopaedic and Rehabilitation Devices Advisory Panel: Metal-on-Metal Hip Implant Systems. (Accessed August 5, 2013, at ). http://www.fda.gov/MedicalDevices/ProductsandMedicalProcedures/ImplantsandProsthetics/MetalonMetalHipImplants/ucm241769.htm.
-
-
-
-
31
-
-
10044235250
-
Quantitative analysis of macrophage apoptosis vs. necrosis induced by cobalt and chromium ions in vitro
-
Catelas I., Petit A., Vail H., et al. Quantitative analysis of macrophage apoptosis vs. necrosis induced by cobalt and chromium ions in vitro. Biomaterials 2005, 26(15):2441.
-
(2005)
Biomaterials
, vol.26
, Issue.15
, pp. 2441
-
-
Catelas, I.1
Petit, A.2
Vail, H.3
-
32
-
-
84878219451
-
High survival of modular tapered stems for proximal femoral bone defects at 5 to 10years followup
-
Van Houwelingen A.P., Duncan C.P., Masri B.A., et al. High survival of modular tapered stems for proximal femoral bone defects at 5 to 10years followup. Clin Orthop Relat Res Feb 2013, 471(2):454.
-
(2013)
Clin Orthop Relat Res
, vol.471
, Issue.2
, pp. 454
-
-
Van Houwelingen, A.P.1
Duncan, C.P.2
Masri, B.A.3
-
33
-
-
84870758359
-
Modular femoral neck fracture after primary total hip arthroplasty
-
Sotereanos N.G., Sauber T.J., Tupis T.T. Modular femoral neck fracture after primary total hip arthroplasty. J Arthroplasty Jan 2013, 28(1):196 e197.
-
(2013)
J Arthroplasty
, vol.28
, Issue.1
-
-
Sotereanos, N.G.1
Sauber, T.J.2
Tupis, T.T.3
-
34
-
-
84864002894
-
Femoral stem fracture and in vivo corrosion of retrieved modular femoral hips
-
Huot Carlson J.C., Van Citters D.W., Currier J.H., et al. Femoral stem fracture and in vivo corrosion of retrieved modular femoral hips. J Arthroplasty 2012, 27(7):1389 e1381.
-
(2012)
J Arthroplasty
, vol.27
, Issue.7
-
-
Huot Carlson, J.C.1
Van Citters, D.W.2
Currier, J.H.3
-
35
-
-
84870766602
-
Fracture of the modular femoral neck component in total hip arthroplasty
-
Ellman M.B., Levine B.R. Fracture of the modular femoral neck component in total hip arthroplasty. J Arthroplasty 2013, 28(1):196 e191.
-
(2013)
J Arthroplasty
, vol.28
, Issue.1
-
-
Ellman, M.B.1
Levine, B.R.2
-
36
-
-
78650927177
-
Fracture of cementless femoral stems at the mid-stem junction in modular revision hip arthroplasty systems
-
Lakstein D., Eliaz N., Levi O., et al. Fracture of cementless femoral stems at the mid-stem junction in modular revision hip arthroplasty systems. J Bone Joint Surg Am 2011, 93(1):57.
-
(2011)
J Bone Joint Surg Am
, vol.93
, Issue.1
, pp. 57
-
-
Lakstein, D.1
Eliaz, N.2
Levi, O.3
-
37
-
-
79955968561
-
Analyses of prosthesis stem failures in noncemented modular hip revision prostheses
-
Efe T., Schmitt J. Analyses of prosthesis stem failures in noncemented modular hip revision prostheses. J Arthroplasty 2011, 26(4):665 e667.
-
(2011)
J Arthroplasty
, vol.26
, Issue.4
-
-
Efe, T.1
Schmitt, J.2
-
39
-
-
77249158849
-
Modular titanium alloy neck adapter failures in hip replacement - failure mode analysis and influence of implant material
-
Grupp T.M., Weik T., Bloemer W., et al. Modular titanium alloy neck adapter failures in hip replacement - failure mode analysis and influence of implant material. BMC Musculoskelet Disord 2010, 11:3.
-
(2010)
BMC Musculoskelet Disord
, vol.11
, pp. 3
-
-
Grupp, T.M.1
Weik, T.2
Bloemer, W.3
-
40
-
-
77954654247
-
Corrosion-induced fracture of a double-modular hip prosthesis: a case report
-
Atwood S.A., Patten E.W., et al. Corrosion-induced fracture of a double-modular hip prosthesis: a case report. J Bone Joint Surg Am 2010, 92(6):1522.
-
(2010)
J Bone Joint Surg Am
, vol.92
, Issue.6
, pp. 1522
-
-
Atwood, S.A.1
Patten, E.W.2
|