메뉴 건너뛰기




Volumn 94 B, Issue 7, 2012, Pages 895-900

Corrosion at the neck-stem junction as a cause of metal ion release and pseudotumour formation

Author keywords

[No Author keywords available]

Indexed keywords

CHROMIUM; COBALT; POLYETHYLENE;

EID: 84863493719     PISSN: 0301620X     EISSN: None     Source Type: Journal    
DOI: 10.1302/0301-620X.94B7.29122     Document Type: Article
Times cited : (208)

References (36)
  • 2
    • 79952201299 scopus 로고    scopus 로고
    • The proximal modular neck in THA: A bridge too far: affirms
    • Dunbar MJ. The proximal modular neck in THA: a bridge too far: affirms. Orthopedics 2010;33:640.
    • (2010) Orthopedics , vol.33 , pp. 640
    • Dunbar, M.J.1
  • 3
    • 77954647496 scopus 로고    scopus 로고
    • Fracture of a modular femoral neck after total hip arthroplasty: A case report
    • Wright G, Sporer S, Urban R, Jacobs J. Fracture of a modular femoral neck after total hip arthroplasty: a case report. J Bone Joint Surg [Am] 2010;92-A:1518-1521.
    • (2010) J Bone Joint Surg [Am] , vol.92 A , pp. 1518-1521
    • Wright, G.1    Sporer, S.2    Urban, R.3    Jacobs, J.4
  • 4
    • 33747880539 scopus 로고    scopus 로고
    • A Case of Disassociation of a Modular Femoral Neck Trunion After Total Hip Arthroplasty
    • DOI 10.1016/j.arth.2005.10.014, PII S0883540305006534
    • Sporer SM, DellaValle C, Jacobs J, Wimmer M. A case of disassociation of a modular femoral neck trunion after total hip arthroplasty. J Arthroplasty 2006;21:918-921. (Pubitemid 44293232)
    • (2006) Journal of Arthroplasty , vol.21 , Issue.6 , pp. 918-921
    • Sporer, S.M.1    DellaValle, C.2    Jacobs, J.3    Wimmer, M.4
  • 5
    • 70349248399 scopus 로고    scopus 로고
    • Corrosion of a hip stem with a modular neck taper junction: A retrieval study of 16 cases
    • Kop AM, Swarts E. Corrosion of a hip stem with a modular neck taper junction: a retrieval study of 16 cases. J Arthroplasty 2009;24:1019-1023.
    • (2009) J Arthroplasty , vol.24 , pp. 1019-1023
    • Kop, A.M.1    Swarts, E.2
  • 6
    • 0027897650 scopus 로고    scopus 로고
    • In vivo corrosion of modular hip prosthesis components in mixed and similar metal combinations: The effect of crevice, stress, motion, and alloy coupling
    • Gilbert JL, Buckley CA, Jacobs JJ. In vivo corrosion of modular hip prosthesis components in mixed and similar metal combinations: the effect of crevice, stress, motion, and alloy coupling. J Biomed Mater Res 2004;27:1533-1544.
    • (2004) J Biomed Mater Res , vol.27 , pp. 1533-1544
    • Gilbert, J.L.1    Buckley, C.A.2    Jacobs, J.J.3
  • 7
    • 72349090736 scopus 로고    scopus 로고
    • Metal release and corrosion effects of modular neck total hip arthroplasty
    • Kretzer JP, Jakubowitz E, Krachler M, Thomsen M, Heisel C. Metal release and corrosion effects of modular neck total hip arthroplasty. Int Orthop 2009;33:1531-1536.
    • (2009) Int Orthop , vol.33 , pp. 1531-1536
    • Kretzer, J.P.1    Jakubowitz, E.2    Krachler, M.3    Thomsen, M.4    Heisel, C.5
  • 8
    • 77954650706 scopus 로고    scopus 로고
    • Early failure of a modular femoral neck total hip arthroplasty component: A case report
    • Wilson DA, Dunbar MJ, Amirault JD, Farhat Z. Early failure of a modular femoral neck total hip arthroplasty component: a case report. J Bone Joint Surg [Am] 2010;92-A:1514-1517.
    • (2010) J Bone Joint Surg [Am] , vol.92 A , pp. 1514-1517
    • Wilson, D.A.1    Dunbar, M.J.2    Amirault, J.D.3    Farhat, Z.4
  • 9
    • 0029257098 scopus 로고    scopus 로고
    • Fretting corrosion accelerates crevice corrosion of modular hip tapers
    • Brown SA, Flemming CA, Kawalec JS, et al. Fretting corrosion accelerates crevice corrosion of modular hip tapers. J Appl Biomater 2004;6:19-26.
    • (2004) J Appl Biomater , vol.6 , pp. 19-26
    • Brown, S.A.1    Flemming, C.A.2    Kawalec, J.S.3
  • 10
    • 0014525462 scopus 로고
    • Traumatic arthritis of the hip after dislocation and acetabular fractures: Treatment by mold arthroplasty: an end result study using a new method of result evaluation
    • Harris WH. Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty: an end result study using a new method of result evaluation. J Bone Joint Surg [Am] 1969;51-A:737-755.
    • (1969) J Bone Joint Surg [Am] , vol.51 A , pp. 737-755
    • Harris, W.H.1
  • 11
    • 0035289322 scopus 로고    scopus 로고
    • Is the Harris hip score system useful to study the outcome of total hip replacement?
    • Soderman P, Malchau H. Is the Harris hip score system useful to study the outcome of hip replacement. Clin Orthop Relat Res 2001;384:189-197. (Pubitemid 33599782)
    • (2001) Clinical Orthopaedics and Related Research , Issue.384 , pp. 189-197
    • Soderman, P.1    Malchau, H.2
  • 14
    • 33845924533 scopus 로고
    • Ueber den Gang bei angeborener Hüftgelenksluxation
    • in German
    • Trendelenburg F. Ueber den Gang bei angeborener Hüftgelenksluxation. Dtsch Med Wochenschr 1895;21:21 (in German).
    • (1895) Dtsch Med Wochenschr , vol.21 , pp. 21
    • Trendelenburg, F.1
  • 15
    • 78649901376 scopus 로고    scopus 로고
    • No authors listed. MDA/2010/033
    • No authors listed. Medicines and Healthcare products Regulatory Agency (MHRA). Medical Device Alert: all metal-on-metal (MOM) hip replacements, 2010 (MDA/2010/033). http://www.mhra.gov.uk/Publications/Safetywarnings/ MedicalDevice-Alerts/CON079157 (date last accessed 9 March 2012).
    • (2010) Medical Device Alert: All Metal-on-metal (MOM) Hip Replacements
  • 17
    • 0029814931 scopus 로고    scopus 로고
    • Distribution of cobalt chromium wear and corrosion products and biologic reactions
    • Merritt K, Brown SA. Distribution of cobalt chromium wear and corrosion products and biologic reactions. Clin Orthop Relat Res 1996;329(Suppl):233-243.
    • (1996) Clin Orthop Relat Res , vol.329 , Issue.SUPPL. , pp. 233-243
    • Merritt, K.1    Brown, S.A.2
  • 18
    • 33846968423 scopus 로고    scopus 로고
    • Modular hip stems: Determination of disassembly force of a neck-stem coupling
    • Pallini F, Cristofolini L, Traina F, Toni A. Modular hip stems: determination of disassembly force of a neck-stem coupling. Artif Organs 2007;31:166-170.
    • (2007) Artif Organs , vol.31 , pp. 166-170
    • Pallini, F.1    Cristofolini, L.2    Traina, F.3    Toni, A.4
  • 24
    • 33947219011 scopus 로고    scopus 로고
    • Blood and urine metal ion levels in young and active patients after Birmingham hip resurfacing arthroplasty
    • DOI 10.1302/0301-620X.89B2.18519
    • Daniel J, Ziaee H, Pradhan C, Pynsent PB, McMinn DJ. Blood and urine metal ion levels in young and active patients after Birmingham hip resurfacing arthroplasty: four-year results of a prospective longitudinal study. J Bone Joint Surg [Br] 2007;89-B:169-173. (Pubitemid 46421460)
    • (2007) Journal of Bone and Joint Surgery - Series B , vol.89 , Issue.2 , pp. 169-173
    • Daniel, J.1    Ziaee, H.2    Pradhan, C.3    Pynsent, P.B.4    McMinn, D.J.W.5
  • 25
    • 53649092535 scopus 로고    scopus 로고
    • The effect of component size and orientation on the concentrations of metal ions after resurfacing arthroplasty of the hip
    • Langton DJ, Jameson SS, Joyce TJ, Webb J, Nargol AV. The effect of component size and orientation on the concentrations of metal ions after resurfacing arthroplasty of the hip. J Bone Joint Surg [Br] 2008;90-B:1143-1151.
    • (2008) J Bone Joint Surg [Br] , vol.90 B , pp. 1143-1151
    • Langton, D.J.1    Jameson, S.S.2    Joyce, T.J.3    Webb, J.4    Nargol, A.V.5
  • 26
    • 34249789255 scopus 로고    scopus 로고
    • Chromium and cobalt ion release following the Durom high carbon content, forged metal-on metal surface replacement of the hip
    • DOI 10.1302/0301-620X.89B4.18054
    • Vendittoli PA, Mottard S, Roy AG, Dupont C, Lavigne M. Chromium and cobalt ion release following the Durom high carbon content, forged metal-on-metal surface replacement of the hip. J Bone Joint Surg [Br] 2007;89-B:441-448. (Pubitemid 46851121)
    • (2007) Journal of Bone and Joint Surgery - Series B , vol.89 , Issue.4 , pp. 441-448
    • Vendittoli, P.-A.1    Mottard, S.2    Roy, A.G.3    Dupont, C.4    Lavigne, M.5
  • 27
    • 83455221435 scopus 로고    scopus 로고
    • What advantage is there to be gained using large modular metal-on-metal bearings in routine primary hip replacement?: A preliminary report of a prospective randomised controlled trial
    • Malviya A, Ramaskandhan JR, Bowman R, et al. What advantage is there to be gained using large modular metal-on-metal bearings in routine primary hip replacement?: a preliminary report of a prospective randomised controlled trial. J Bone Joint Surg [Br] 2011;93-B:1602-1609.
    • (2011) J Bone Joint Surg [Br] , vol.93 B , pp. 1602-1609
    • Malviya, A.1    Ramaskandhan, J.R.2    Bowman, R.3
  • 28
    • 79955083655 scopus 로고    scopus 로고
    • High failure rates with a large-diameter hybrid metal-on-metal total hip replacement: Clinical, radiological and retrieval analysis
    • Bolland BJ, Culliford DJ, Langton DJ, et al. High failure rates with a large-diameter hybrid metal-on-metal total hip replacement: clinical, radiological and retrieval analysis. J Bone Joint Surg [Br] 2011;93-B:608-615.
    • (2011) J Bone Joint Surg [Br] , vol.93 B , pp. 608-615
    • Bolland, B.J.1    Culliford, D.J.2    Langton, D.J.3
  • 29
    • 51349129697 scopus 로고    scopus 로고
    • Inflammatory pseudotumor associated with femoral nerve palsy following metal-on-metal resurfacing of the hip: A case report
    • Clayton RA, Beggs I, Salter DM, et al. Inflammatory pseudotumor associated with femoral nerve palsy following metal-on-metal resurfacing of the hip: a case report. J Bone Joint Surg [Am] 2008;90-A:1988-1993.
    • (2008) J Bone Joint Surg [Am] , vol.90 A , pp. 1988-1993
    • Clayton, R.A.1    Beggs, I.2    Salter, D.M.3
  • 31
    • 72249088640 scopus 로고    scopus 로고
    • Risk factors for inflammatory pseudotumour formation following hip resurfacing
    • Glyn-Jones S, Pandit H, Kwon YM, et al. Risk factors for inflammatory pseudotumour formation following hip resurfacing. J Bone Joint Surg [Br] 2009;91-B:1566-1574.
    • (2009) J Bone Joint Surg [Br] , vol.91 B , pp. 1566-1574
    • Glyn-Jones, S.1    Pandit, H.2    Kwon, Y.M.3
  • 32
    • 72549098037 scopus 로고    scopus 로고
    • Necrotic and inflammatory changes in metal-on-metal resurfacing hip arthroplasties
    • Mahendra G, Pandit H, Kliskey K, et al. Necrotic and inflammatory changes in metal-on-metal resurfacing hip arthroplasties. Acta Orthop 2009;80:653-659.
    • (2009) Acta Orthop , vol.80 , pp. 653-659
    • Mahendra, G.1    Pandit, H.2    Kliskey, K.3
  • 33
    • 75649095676 scopus 로고    scopus 로고
    • Early failure of metal-on-metal bearings in hip resurfacing and large-diameter total hip replacement: A consequence of excess wear
    • Langton DJ, Jameson SS, Joyce TJ, et al. Early failure of metal-on-metal bearings in hip resurfacing and large-diameter total hip replacement: a consequence of excess wear. J Bone Joint Surg [Br] 2010;92-B:38-46.
    • (2010) J Bone Joint Surg [Br] , vol.92 B , pp. 38-46
    • Langton, D.J.1    Jameson, S.S.2    Joyce, T.J.3
  • 34
    • 80053477869 scopus 로고    scopus 로고
    • Sensitivity and specificity of blood cobalt and chromium metal ions for predicting failure of metal-on-metal hip replacement
    • Hart AJ, Sabah SA, Bandi AS, et al. Sensitivity and specificity of blood cobalt and chromium metal ions for predicting failure of metal-on-metal hip replacement. J Bone Joint Surg [Br] 2011;93-B:1308-1313.
    • (2011) J Bone Joint Surg [Br] , vol.93 B , pp. 1308-1313
    • Hart, A.J.1    Sabah, S.A.2    Bandi, A.S.3
  • 35
    • 84856925439 scopus 로고    scopus 로고
    • Mixing and matching causing taper wear: Corrosion associated with pseudotumour formation
    • Chana R, Esposito C, Campbell PA, Walter WK, Walter WL. Mixing and matching causing taper wear: corrosion associated with pseudotumour formation. J Bone Joint Surg [Br] 2012;94-B:281-286.
    • (2012) J Bone Joint Surg [Br] , vol.94 B , pp. 281-286
    • Chana, R.1    Esposito, C.2    Campbell, P.A.3    Walter, W.K.4    Walter, W.L.5
  • 36
    • 84857873162 scopus 로고    scopus 로고
    • Current controversies in hip surgery: A report on the proceedings of the London Hip Meeting 2011
    • Haddad FS, Konan S. Current controversies in hip surgery: a report on the proceedings of the London Hip Meeting 2011. J Bone Joint Surg [Br] 2012;94-B:297-301.
    • (2012) J Bone Joint Surg [Br] , vol.94 B , pp. 297-301
    • Haddad, F.S.1    Konan, S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.