메뉴 건너뛰기




Volumn 32, Issue 3, 2010, Pages 360-366

The utility of the Sysmex XE-2100 analyzer's NEUT-X and NEUT-Y parameters for detecting neutrophil dysplasia in myelodysplastic syndromes

Author keywords

Chronic myelomonocytic leukemia; Myelodysplastic syndromes; NEUT X; NEUT Y; Neutrophil dysplasia

Indexed keywords

ANALYZER; ANEMIA; ARTICLE; CHRONIC MYELOMONOCYTIC LEUKEMIA; CLINICAL ARTICLE; COMORBIDITY; CONTROL GROUP; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; DYSPLASIA; HEMATOLOGICAL PARAMETERS; HUMAN; LEUKOPENIA; MYELODYSPLASTIC SYNDROME; NEUTROPHIL DYSPLASIA; PRIORITY JOURNAL; STATISTICAL SIGNIFICANCE; CHEMISTRY; CYTOLOGY; FEMALE; GRANULOCYTE; MALE; MYELODYSPLASTIC SYNDROMES; NEUTROPHIL; PATHOLOGY; RECEIVER OPERATING CHARACTERISTIC; SENSITIVITY AND SPECIFICITY; STANDARD;

EID: 77953562454     PISSN: 17515521     EISSN: 1751553X     Source Type: Journal    
DOI: 10.1111/j.1751-553X.2009.01194.x     Document Type: Article
Times cited : (58)

References (7)
  • 3
    • 77953552855 scopus 로고    scopus 로고
    • Usefulness of XE-2100 structural parameters in the diagnosis of myelodysplastic syndrome
    • Sysmex Europe GMBH, Germany
    • Cymbalista F. (2005) Usefulness of XE-2100 structural parameters in the diagnosis of myelodysplastic syndrome. Proceedings of the Sysmex European Symposium Austria, pp. 26-32. Sysmex Europe GMBH, Germany.
    • (2005) Proceedings of the Sysmex European Symposium Austria , pp. 26-32
    • Cymbalista, F.1
  • 4
    • 77953592921 scopus 로고    scopus 로고
    • Usefulness of NEUT-X determination in routine diagnostic procedures: Application to myelodys-plastic syndromes
    • ISLH Sydney
    • Cymbalista F. (2008) Usefulness of NEUT-X determination in routine diagnostic procedures: application to myelodys-plastic syndromes. Sysmex Luncheon Symposium. ISLH Sydney.
    • (2008) Sysmex Luncheon Symposium
    • Cymbalista, F.1
  • 5
    • 51749111590 scopus 로고    scopus 로고
    • Automation and validation of a rapid method to assess neutrophil and monocyte activation by routine fluore-scence flow cytometry in vitro
    • Linssen J., Aderhold S., Nierhaus A., Frings D., Kaltschmidt C. & Zänker K. (2008) Automation and validation of a rapid method to assess neutrophil and monocyte activation by routine fluore-scence flow cytometry in vitro. Cytometry Part B (Clinical Cytometry) 74B, 295-309.
    • (2008) Cytometry Part B (Clinical Cytometry) , vol.74 B , pp. 295-309
    • Linssen, J.1    Aderhold, S.2    Nierhaus, A.3    Frings, D.4    Kaltschmidt, C.5    Zänker, K.6
  • 6
    • 77953546904 scopus 로고    scopus 로고
    • Interest of NEUT-X in MDS/MPD diagnosis and chronic monocytosis
    • Turkey; May 14-15., Sysmex Europe GMBH, Germany
    • Schillinger F. (2009) Interest of NEUT-X in MDS/MPD diagnosis and chronic monocytosis. Sysmex 5th European Haematology Symposium, Turkey; May 14-15. pp. 57. Sysmex Europe GMBH, Germany.
    • (2009) Sysmex 5th European Haematology Symposium , pp. 57
    • Schillinger, F.1
  • 7
    • 77953580185 scopus 로고    scopus 로고
    • Myelodysplastic syndromes.
    • Tkachuk D.C., Chun K. & Hisrschmann J.V. eds, 1st edn, Lippincott Willians & Wilkins, Philadelphia, PA
    • Tkachuk D.C., Chun K. & Hisrschmann J.V., eds (2007) Myelodysplastic syndromes. In: Wintrobe's Atlas of Clinical Hematology, 1st edn, Lippincott Willians & Wilkins, Philadelphia, PA. 94-104.
    • (2007) Wintrobe's Atlas of Clinical Hematology , pp. 94-104


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.