-
1
-
-
84888138435
-
-
Eye Bank Association of America. Washington, DC: Eye Bank Association of America
-
Eye Bank Association of America. 2011 Eye Banking Statistical Report. Washington, DC: Eye Bank Association of America; 2010.
-
(2010)
2011 Eye Banking Statistical Report
-
-
-
2
-
-
35549010689
-
Evaluation of deep lamellar endothelial keratoplasty surgery using scatterometry and wavefront analyses
-
Hindman HB, McCally RL, Myrowitz E, et al. Evaluation of deep lamellar endothelial keratoplasty surgery using scatterometry and wavefront analyses. Ophthalmology. 2007;114: 2006-2012.
-
(2007)
Ophthalmology.
, vol.114
, pp. 2006-2012
-
-
Hindman, H.B.1
McCally, R.L.2
Myrowitz, E.3
-
3
-
-
84856428999
-
Comparison of corneal surface higher-order aberrations after endothelial keratoplasty, femtosecond laser-assisted keratoplasty, and conventional penetrating keratoplasty
-
Chamberlain W, Omid N, Lin A, et al. Comparison of corneal surface higher-order aberrations after endothelial keratoplasty, femtosecond laser-assisted keratoplasty, and conventional penetrating keratoplasty. Cornea. 2012;31:6-13.
-
(2012)
Cornea.
, vol.31
, pp. 6-13
-
-
Chamberlain, W.1
Omid, N.2
Lin, A.3
-
4
-
-
84855995398
-
Characteristic higher-order aberrations of the anterior and posterior corneal surfaces in 3 corneal transplantation techniques
-
Koh S, Maeda N, Nakagawa T, et al. Characteristic higher-order aberrations of the anterior and posterior corneal surfaces in 3 corneal transplantation techniques. Am J Ophthalmol. 2012;153:284-290.e1.
-
(2012)
Am J Ophthalmol.
, vol.153
-
-
Koh, S.1
Maeda, N.2
Nakagawa, T.3
-
5
-
-
77951623364
-
Corneal higher-order aberrations after Descemet's stripping automated endothelial keratoplasty
-
Muftuoglu O, Prasher P, Bowman RW, et al. Corneal higher-order aberrations after Descemet's stripping automated endothelial keratoplasty. Ophthalmology. 2010;117:878-884.e6.
-
(2010)
Ophthalmology.
, vol.117
-
-
Muftuoglu, O.1
Prasher, P.2
Bowman, R.W.3
-
6
-
-
84857914841
-
Corneal higher-order aberrations after Descemet's membrane endothelial keratoplasty
-
Rudolph M, Laaser K, Bachmann BO, et al. Corneal higher-order aberrations after Descemet's membrane endothelial keratoplasty. Ophthalmology. 2012;119:528-535.
-
(2012)
Ophthalmology.
, vol.119
, pp. 528-535
-
-
Rudolph, M.1
Laaser, K.2
Bachmann, B.O.3
-
7
-
-
62349137556
-
Effect of anterior and posterior corneal surface irregularity on vision after Descemet-stripping endothelial keratoplasty
-
Yamaguchi T, Negishi K, Yamaguchi K, et al. Effect of anterior and posterior corneal surface irregularity on vision after Descemet-stripping endothelial keratoplasty. J Cataract Refract Surg. 2009;35:688-694.
-
(2009)
J Cataract Refract Surg.
, vol.35
, pp. 688-694
-
-
Yamaguchi, T.1
Negishi, K.2
Yamaguchi, K.3
-
8
-
-
84863789659
-
Corneal haze determined by confocal microscopy 2 years after Descemet stripping with endothelial keratoplasty for Fuchs corneal dystrophy
-
Baratz KH, McLaren JW, Maguire LJ, et al. Corneal haze determined by confocal microscopy 2 years after Descemet stripping with endothelial keratoplasty for Fuchs corneal dystrophy. Arch Ophthalmol. 2012;130: 868-874.
-
(2012)
Arch Ophthalmol.
, vol.130
, pp. 868-874
-
-
Baratz, K.H.1
McLaren, J.W.2
Maguire, L.J.3
-
9
-
-
84864417357
-
In vivo evaluation of DSAEK interface with scanning-laser confocal microscopy
-
Ferrari G, Reichegger V, Ludergnani L, et al. In vivo evaluation of DSAEK interface with scanning-laser confocal microscopy. BMC Ophthalmol. 2012;12:32.
-
(2012)
BMC Ophthalmol.
, vol.12
, pp. 32
-
-
Ferrari, G.1
Reichegger, V.2
Ludergnani, L.3
-
10
-
-
43949100981
-
In vivo laser confocal microscopy after Descemet stripping with automated endothelial keratoplasty
-
Kobayashi A, Mawatari Y, Yokogawa H, et al. In vivo laser confocal microscopy after Descemet stripping with automated endothelial keratoplasty. Am J Ophthalmol. 2008;145:977-985.
-
(2008)
Am J Ophthalmol.
, vol.145
, pp. 977-985
-
-
Kobayashi, A.1
Mawatari, Y.2
Yokogawa, H.3
-
11
-
-
84867361096
-
Quality of vision in eyes after selective lamellar keratoplasty
-
Koh S, Maeda N, Nakagawa T, et al. Quality of vision in eyes after selective lamellar keratoplasty. Cornea. 2012;31(suppl 1):S45-S49.
-
(2012)
Cornea.
, vol.31
, Issue.SUPPL. 1
-
-
Koh, S.1
Maeda, N.2
Nakagawa, T.3
-
12
-
-
60549086170
-
The effect of corneal light scatter on vision after Descemet stripping with endothelial keratoplasty
-
Patel SV, Baratz KH, Hodge DO, et al. The effect of corneal light scatter on vision after Descemet stripping with endothelial keratoplasty. Arch Ophthalmol. 2009;127:153-160.
-
(2009)
Arch Ophthalmol.
, vol.127
, pp. 153-160
-
-
Patel, S.V.1
Baratz, K.H.2
Hodge, D.O.3
-
13
-
-
68849131676
-
Tandem scanning confocal microscopy of cornea after Descemet stripping automated endothelial keratoplasty
-
Prasher P, Muftuoglu O, Bowman RW, et al. Tandem scanning confocal microscopy of cornea after Descemet stripping automated endothelial keratoplasty. Eye Contact Lens. 2009;35:196-202.
-
(2009)
Eye Contact Lens.
, vol.35
, pp. 196-202
-
-
Prasher, P.1
Muftuoglu, O.2
Bowman, R.W.3
-
14
-
-
79951770888
-
Comparison of corneal thickness and haze in DSAEK and penetrating keratoplasty
-
Uchino Y, Shimmura S, Yamaguchi T, et al. Comparison of corneal thickness and haze in DSAEK and penetrating keratoplasty. Cornea. 2011;30:287-290.
-
(2011)
Cornea.
, vol.30
, pp. 287-290
-
-
Uchino, Y.1
Shimmura, S.2
Yamaguchi, T.3
-
15
-
-
83455212187
-
Quality of vision in patients with Fuchs endothelial dystrophy and after Descemet stripping endothelial keratoplasty
-
van der Meulen IJ, Patel SV, Lapid-Gortzak R, et al. Quality of vision in patients with Fuchs endothelial dystrophy and after Descemet stripping endothelial keratoplasty. Arch Ophthalmol. 2011;129:1537-1542.
-
(2011)
Arch Ophthalmol.
, vol.129
, pp. 1537-1542
-
-
Van Der Meulen, I.J.1
Patel, S.V.2
Lapid-Gortzak, R.3
-
16
-
-
67349154933
-
Corneal deturgescence after Descemet stripping automated endothelial keratoplasty evaluated by Visante anterior segment optical coherence tomography
-
Di Pascuale MA, Prasher P, Schlecte C, et al. Corneal deturgescence after Descemet stripping automated endothelial keratoplasty evaluated by Visante anterior segment optical coherence tomography. Am J Ophthalmol. 2009;148:32-37.e1.
-
(2009)
Am J Ophthalmol.
, vol.148
-
-
Di Pascuale, M.A.1
Prasher, P.2
Schlecte, C.3
-
17
-
-
66749168957
-
Changes in donor corneal lenticule thickness after Descemet's stripping automated endothelial keratoplasty (DSAEK) with organ-cultured corneas
-
Pogorelov P, Cursiefen C, Bachmann BO, et al. Changes in donor corneal lenticule thickness after Descemet's stripping automated endothelial keratoplasty (DSAEK) with organ-cultured corneas. Br J Ophthalmol. 2009;93:825-829.
-
(2009)
Br J Ophthalmol.
, vol.93
, pp. 825-829
-
-
Pogorelov, P.1
Cursiefen, C.2
Bachmann, B.O.3
-
18
-
-
84867097872
-
Descemet's stripping automated endothelial keratoplasty: The tenuous relationship between donor thickness and postoperative vision
-
Terry MA, Straiko MD, Goshe JM, et al. Descemet's stripping automated endothelial keratoplasty: the tenuous relationship between donor thickness and postoperative vision. Ophthalmology. 2012;119:1988-1996.
-
(2012)
Ophthalmology.
, vol.119
, pp. 1988-1996
-
-
Terry, M.A.1
Straiko, M.D.2
Goshe, J.M.3
-
19
-
-
80053631356
-
Descemet stripping automated endothelial keratoplasty: Effect of intraoperative lenticule thickness on visual outcome and endothelial cell density
-
Van Cleynenbreugel H, Remeijer L, Hillenaar T. Descemet stripping automated endothelial keratoplasty: effect of intraoperative lenticule thickness on visual outcome and endothelial cell density. Cornea. 2011;30:1195-1200.
-
(2011)
Cornea.
, vol.30
, pp. 1195-1200
-
-
Van Cleynenbreugel, H.1
Remeijer, L.2
Hillenaar, T.3
-
20
-
-
84862816162
-
Three-year visual acuity outcomes after Descemet's stripping automated endothelial keratoplasty
-
Li JY, Terry MA, Goshe J, et al. Three-year visual acuity outcomes after Descemet's stripping automated endothelial keratoplasty. Ophthalmology. 2012;119:1126-1129.
-
(2012)
Ophthalmology.
, vol.119
, pp. 1126-1129
-
-
Li, J.Y.1
Terry, M.A.2
Goshe, J.3
-
21
-
-
65649085963
-
Visual performance after correcting higher order aberrations in keratoconic eyes
-
Sabesan R, Yoon G. Visual performance after correcting higher order aberrations in keratoconic eyes. J Vis. 2009;9:6.1-6.10.
-
(2009)
J Vis.
, vol.9
, pp. 61-610
-
-
Sabesan, R.1
Yoon, G.2
-
23
-
-
59449088488
-
Optical effects of anti-TGFbeta treatment after photorefractive keratectomy in a cat model
-
Bühren J, Nagy L, Swanton JN, et al. Optical effects of anti-TGFbeta treatment after photorefractive keratectomy in a cat model. Invest Ophthalmol Vis Sci. 2009;50:634-643.
-
(2009)
Invest Ophthalmol Vis Sci.
, vol.50
, pp. 634-643
-
-
Bühren, J.1
Nagy, L.2
Swanton, J.N.3
-
24
-
-
34249022426
-
Photorefractive keratectomy in the cat eye: Biological and optical outcomes
-
Nagy LJ, MacRae S, Yoon G, et al. Photorefractive keratectomy in the cat eye: biological and optical outcomes. J Cataract Refract Surg. 2007; 33:1051-1064.
-
(2007)
J Cataract Refract Surg.
, vol.33
, pp. 1051-1064
-
-
Nagy, L.J.1
MacRae, S.2
Yoon, G.3
-
25
-
-
33745184909
-
Corneal light backscatter measured by optical coherence tomography after LASIK
-
Wang J, Thomas J, Cox I. Corneal light backscatter measured by optical coherence tomography after LASIK. J Refract Surg. 2006;22:604-610.
-
(2006)
J Refract Surg.
, vol.22
, pp. 604-610
-
-
Wang, J.1
Thomas, J.2
Cox, I.3
-
27
-
-
77955705410
-
Glistenings and surface light scattering in intraocular lenses
-
Werner L. Glistenings and surface light scattering in intraocular lenses. J Cataract Refract Surg. 2010;36:1398-1420.
-
(2010)
J Cataract Refract Surg.
, vol.36
, pp. 1398-1420
-
-
Werner, L.1
-
28
-
-
81355148610
-
Endothelial keratoplasty: Fellow eyes comparison of Descemet stripping automated endothelial keratoplasty and Descemet membrane endothelial keratoplasty
-
Guerra FP, Anshu A, Price MO, et al. Endothelial keratoplasty: fellow eyes comparison of Descemet stripping automated endothelial keratoplasty and Descemet membrane endothelial keratoplasty. Cornea. 2011;30:1382-1386.
-
(2011)
Cornea.
, vol.30
, pp. 1382-1386
-
-
Guerra, F.P.1
Anshu, A.2
Price, M.O.3
-
29
-
-
0033941489
-
Contrast and glare testing in the assessment of visual performance of candidate eyes for penetrating keratoplasty
-
Fontaine N, Boisjoly H, Gresset J, et al. Contrast and glare testing in the assessment of visual performance of candidate eyes for penetrating keratoplasty. Cornea. 2000;19:433-438.
-
(2000)
Cornea.
, vol.19
, pp. 433-438
-
-
Fontaine, N.1
Boisjoly, H.2
Gresset, J.3
-
30
-
-
0026197031
-
Evaluation of glare in normal and pseudophakic subjects
-
Prasad A, Asbell PA, Senie RT. Evaluation of glare in normal and pseudophakic subjects. Ann Ophthalmol. 1991;23:268-272.
-
(1991)
Ann Ophthalmol.
, vol.23
, pp. 268-272
-
-
Prasad, A.1
Asbell, P.A.2
Senie, R.T.3
-
31
-
-
84867908398
-
Modeling the effect of forward scatter and aberrations on visual acuity after endothelial keratoplasty
-
McLaren JW, Patel SV. Modeling the effect of forward scatter and aberrations on visual acuity after endothelial keratoplasty. Invest Ophthalmol Vis Sci. 2012;53:5545-5551.
-
(2012)
Invest Ophthalmol Vis Sci.
, vol.53
, pp. 5545-5551
-
-
McLaren, J.W.1
Patel, S.V.2
-
32
-
-
0022814539
-
Effect of epithelial and stromal edema on the light scattering properties of the cornea
-
Griffiths SN, Drasdo N, Barnes DA, et al. Effect of epithelial and stromal edema on the light scattering properties of the cornea. Am J Optom Physiol Opt. 1986;63:888-894.
-
(1986)
Am J Optom Physiol Opt.
, vol.63
, pp. 888-894
-
-
Griffiths, S.N.1
Drasdo, N.2
Barnes, D.A.3
-
33
-
-
0023868795
-
Glare disability devices for cataractous eyes: A consumer's guide
-
Neumann AC, McCarty GR, Locke J, et al. Glare disability devices for cataractous eyes: a consumer's guide. J Cataract Refract Surg. 1988;14: 212-216.
-
(1988)
J Cataract Refract Surg.
, vol.14
, pp. 212-216
-
-
Neumann, A.C.1
McCarty, G.R.2
Locke, J.3
-
34
-
-
0033064004
-
Corneal stromal wound healing in refractive surgery: The role of myofibroblasts
-
Jester JV, Petroll WM, Cavanagh HD. Corneal stromal wound healing in refractive surgery: the role of myofibroblasts. Prog Retin Eye Res. 1999; 18:311-356.
-
(1999)
Prog Retin Eye Res.
, vol.18
, pp. 311-356
-
-
Jester, J.V.1
Petroll, W.M.2
Cavanagh, H.D.3
-
35
-
-
84867288700
-
Visual performance with wave aberration correction after penetrating, deep anterior lamellar, or endothelial keratoplasty
-
Pantanelli SM, Sabesan R, Ching SS, et al. Visual performance with wave aberration correction after penetrating, deep anterior lamellar, or endothelial keratoplasty. Invest Ophthalmol Vis Sci. 2012;53:4797-4804.
-
(2012)
Invest Ophthalmol Vis Sci.
, vol.53
, pp. 4797-4804
-
-
Pantanelli, S.M.1
Sabesan, R.2
Ching, S.S.3
-
36
-
-
84864448451
-
Anterior corneal aberrations after Descemet's stripping endothelial keratoplasty for Fuchs' endothelial dystrophy
-
Patel SV, Baratz KH, Maguire LJ, et al. Anterior corneal aberrations after Descemet's stripping endothelial keratoplasty for Fuchs' endothelial dystrophy. Ophthalmology. 2012;119:1522-1529.
-
(2012)
Ophthalmology.
, vol.119
, pp. 1522-1529
-
-
Patel, S.V.1
Baratz, K.H.2
Maguire, L.J.3
-
37
-
-
33751345891
-
Normal-eye Zernike coefficients and root-mean-square wavefront errors
-
Salmon TO, van de Pol C. Normal-eye Zernike coefficients and root-mean-square wavefront errors. J Cataract Refract Surg. 2006;32: 2064-2074.
-
(2006)
J Cataract Refract Surg.
, vol.32
, pp. 2064-2074
-
-
Salmon, T.O.1
Van De Pol, C.2
-
38
-
-
65349118089
-
Correlation of higher-order wavefront aberrations with visual function in pseudophakic eyes
-
Hayashi K, Yoshida M, Hayashi H. Correlation of higher-order wavefront aberrations with visual function in pseudophakic eyes. Eye (Lond). 2008;22:1476-1482.
-
(2008)
Eye (Lond).
, vol.22
, pp. 1476-1482
-
-
Hayashi, K.1
Yoshida, M.2
Hayashi, H.3
-
39
-
-
34249853142
-
The contribution of the posterior surface to the coma aberration of the human cornea
-
Dubbelman M, Sicam VA, van der Heijde RG. The contribution of the posterior surface to the coma aberration of the human cornea. J Vis. 2007;7:10.1-10.18.
-
(2007)
J Vis.
, vol.7
, pp. 101-1018
-
-
Dubbelman, M.1
Sicam, V.A.2
Van Der Heijde, R.G.3
-
40
-
-
80051533525
-
The contribution of the posterior surface to the corneal aberrations in eyes after keratoplasty
-
Yamaguchi T, Ohnuma K, Tomida D, et al. The contribution of the posterior surface to the corneal aberrations in eyes after keratoplasty. Invest Ophthalmol Vis Sci. 2011;52:6222-6229.
-
(2011)
Invest Ophthalmol Vis Sci.
, vol.52
, pp. 6222-6229
-
-
Yamaguchi, T.1
Ohnuma, K.2
Tomida, D.3
-
41
-
-
77957273179
-
Host and graft thickness after Descemet stripping endothelial keratoplasty for Fuchs endothelial dystrophy
-
Ahmed KA, McLaren JW, Baratz KH, et al. Host and graft thickness after Descemet stripping endothelial keratoplasty for Fuchs endothelial dystrophy. Am J Ophthalmol. 2010;150:490-497.e2.
-
(2010)
Am J Ophthalmol.
, vol.150
-
-
Ahmed, K.A.1
McLaren, J.W.2
Baratz, K.H.3
-
42
-
-
79952989175
-
Comparison of central corneal graft thickness to visual acuity outcomes in endothelial keratoplasty
-
Neff KD, Biber JM, Holland EJ. Comparison of central corneal graft thickness to visual acuity outcomes in endothelial keratoplasty. Cornea. 2011;30:388-391.
-
(2011)
Cornea.
, vol.30
, pp. 388-391
-
-
Neff, K.D.1
Biber, J.M.2
Holland, E.J.3
-
43
-
-
67149139339
-
Thickness measurements of donor posterior disks after descemet stripping endothelial keratoplasty with anterior segment optical coherence tomography
-
Nieuwendaal CP, van Velthoven ME, Biallosterski C, et al. Thickness measurements of donor posterior disks after descemet stripping endothelial keratoplasty with anterior segment optical coherence tomography. Cornea. 2009;28:298-303.
-
(2009)
Cornea.
, vol.28
, pp. 298-303
-
-
Nieuwendaal, C.P.1
Van Velthoven, M.E.2
Biallosterski, C.3
-
44
-
-
33750289861
-
Descemet's stripping with endothelial keratoplasty: Comparative outcomes with microkeratome-dissected and manually dissected donor tissue
-
Price MO, Price FW Jr. Descemet's stripping with endothelial keratoplasty: comparative outcomes with microkeratome-dissected and manually dissected donor tissue. Ophthalmology. 2006;113:1936-1942.
-
(2006)
Ophthalmology.
, vol.113
, pp. 1936-1942
-
-
Price, M.O.1
Price Jr., F.W.2
-
45
-
-
81855170006
-
Graft thickness, graft folds, and aberrations after descemet stripping endothelial keratoplasty for Fuchs dystrophy
-
Seery LS, Nau CB, McLaren JW, et al. Graft thickness, graft folds, and aberrations after descemet stripping endothelial keratoplasty for Fuchs dystrophy. Am J Ophthalmol. 2011;152:910-916.
-
(2011)
Am J Ophthalmol.
, vol.152
, pp. 910-916
-
-
Seery, L.S.1
Nau, C.B.2
McLaren, J.W.3
-
46
-
-
84863393714
-
Impact of graft thickness on visual acuity after Descemet's stripping endothelial keratoplasty
-
Shinton AJ, Tsatsos M, Konstantopoulos A, et al. Impact of graft thickness on visual acuity after Descemet's stripping endothelial keratoplasty. Br J Ophthalmol. 2012;96:246-249.
-
(2012)
Br J Ophthalmol.
, vol.96
, pp. 246-249
-
-
Shinton, A.J.1
Tsatsos, M.2
Konstantopoulos, A.3
-
48
-
-
84863436323
-
Optical absorption and scattering of bovine cornea, lens, and retina in the near-infrared region
-
Yust BG, Mimun LC, Sardar DK. Optical absorption and scattering of bovine cornea, lens, and retina in the near-infrared region. Lasers Med Sci. 2012;27:413-422.
-
(2012)
Lasers Med Sci.
, vol.27
, pp. 413-422
-
-
Yust, B.G.1
Mimun, L.C.2
Sardar, D.K.3
-
49
-
-
0001046861
-
Direct summation of fields for light scattering by fibrils with applications to normal corneas
-
Freund DE, McCally RL, Farrell RA. Direct summation of fields for light scattering by fibrils with applications to normal corneas. Appl Opt. 1986; 25:2739.
-
(1986)
Appl Opt.
, vol.25
, pp. 2739
-
-
Freund, D.E.1
McCally, R.L.2
Farrell, R.A.3
-
50
-
-
0022816903
-
Effects of fibril orientations on light scattering in the cornea
-
Freund DE, McCally RL, Farrell RA. Effects of fibril orientations on light scattering in the cornea. J Opt Soc Am A. 1986;3:1970-1982.
-
(1986)
J Opt Soc Am A.
, vol.3
, pp. 1970-1982
-
-
Freund, D.E.1
McCally, R.L.2
Farrell, R.A.3
-
51
-
-
79953288199
-
Retinal point-spread function after corneal transplantation for Fuchs' dystrophy
-
Seery LS, McLaren JW, Kittleson KM, et al. Retinal point-spread function after corneal transplantation for Fuchs' dystrophy. Invest Ophthalmol Vis Sci. 2011;52:1003-1008.
-
(2011)
Invest Ophthalmol Vis Sci.
, vol.52
, pp. 1003-1008
-
-
Seery, L.S.1
McLaren, J.W.2
Kittleson, K.M.3
-
52
-
-
84867402762
-
Decreased corneal sensitivity and abnormal corneal nerves in Fuchs endothelial dystrophy
-
Ahuja Y, Baratz KH, McLaren JW, et al. Decreased corneal sensitivity and abnormal corneal nerves in Fuchs endothelial dystrophy. Cornea. 2012;31:1257-1263.
-
(2012)
Cornea.
, vol.31
, pp. 1257-1263
-
-
Ahuja, Y.1
Baratz, K.H.2
McLaren, J.W.3
-
53
-
-
0024321317
-
Characterization of stroma from Fuchs' endothelial dystrophy corneas
-
Calandra A, Chwa M, Kenney MC. Characterization of stroma from Fuchs' endothelial dystrophy corneas. Cornea. 1989;8:90-97.
-
(1989)
Cornea.
, vol.8
, pp. 90-97
-
-
Calandra, A.1
Chwa, M.2
Kenney, M.C.3
-
54
-
-
79955759365
-
Anterior keratocyte depletion in Fuchs endothelial dystrophy
-
Hecker LA, McLaren JW, Bachman LA, et al. Anterior keratocyte depletion in Fuchs endothelial dystrophy. Arch Ophthalmol. 2011;129:555-561.
-
(2011)
Arch Ophthalmol.
, vol.129
, pp. 555-561
-
-
Hecker, L.A.1
McLaren, J.W.2
Bachman, L.A.3
-
55
-
-
0006328245
-
Extracellular matrix alterations in human corneas with bullous keratopathy
-
Ljubimov AV, Burgeson RE, Butkowski RJ, et al. Extracellular matrix alterations in human corneas with bullous keratopathy. Invest Ophthalmol Vis Sci. 1996;37:997-1007.
-
(1996)
Invest Ophthalmol Vis Sci.
, vol.37
, pp. 997-1007
-
-
Ljubimov, A.V.1
Burgeson, R.E.2
Butkowski, R.J.3
|