메뉴 건너뛰기




Volumn 22, Issue 6, 2006, Pages 604-610

Corneal light backscatter measured by optical coherence tomography after LASIK

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTICLE; CLINICAL ARTICLE; CONFOCAL MICROSCOPY; CORNEA DISEASE; CORNEA STROMA; EPITHELIUM CELL; FEMALE; HUMAN; KERATOMILEUSIS; LIGHT SCATTERING; MALE; MEASUREMENT; OPTICAL COHERENCE TOMOGRAPHY; POST HOC ANALYSIS; PREOPERATIVE EVALUATION; PRIORITY JOURNAL; QUANTITATIVE ANALYSIS; STROMA CELL;

EID: 33745184909     PISSN: 1081597X     EISSN: None     Source Type: Journal    
DOI: 10.3928/1081-597x-20060601-14     Document Type: Article
Times cited : (16)

References (29)
  • 1
    • 4444278818 scopus 로고    scopus 로고
    • Monitoring corneal structures with slit lamp-adapted optical coherence tomography in laser in situ keratomileusis
    • Wirbelauer C, Pham DT. Monitoring corneal structures with slit lamp-adapted optical coherence tomography in laser in situ keratomileusis. J Cataract Refract Surg. 2004;30:1851-1860.
    • (2004) J Cataract Refract Surg , vol.30 , pp. 1851-1860
    • Wirbelauer, C.1    Pham, D.T.2
  • 2
    • 0033873480 scopus 로고    scopus 로고
    • Arc-scanning very high-frequency digital ultrasound for 3D pachymetric mapping of the corneal epithelium and stroma in laser in situ keratomileusis
    • Reinstein DZ, Silverman RH, Raevsky T, Simoni GJ, Lloyd HO, Najafi DJ, Rondeau MJ, Coleman DJ. Arc-scanning very high-frequency digital ultrasound for 3D pachymetric mapping of the corneal epithelium and stroma in laser in situ keratomileusis. J Refract Surg. 2000;16:414-430.
    • (2000) J Refract Surg , vol.16 , pp. 414-430
    • Reinstein, D.Z.1    Silverman, R.H.2    Raevsky, T.3    Simoni, G.J.4    Lloyd, H.O.5    Najafi, D.J.6    Rondeau, M.J.7    Coleman, D.J.8
  • 3
    • 0033756170 scopus 로고    scopus 로고
    • Stromal wound healing explains refractive instability and haze development after photorefractive keratectomy: A 1-year confocal microscopic study
    • Moller-Pedersen T, Cavanagh HD, Petroll WM, Jester JV. Stromal wound healing explains refractive instability and haze development after photorefractive keratectomy: a 1-year confocal microscopic study. Ophthalmology. 2000;107:1235-1245.
    • (2000) Ophthalmology , vol.107 , pp. 1235-1245
    • Moller-Pedersen, T.1    Cavanagh, H.D.2    Petroll, W.M.3    Jester, J.V.4
  • 4
    • 0029925420 scopus 로고    scopus 로고
    • Scheimpflug anterior segment photography assessment of wound healing after myopic excimer laser photorefractive keratectomy
    • Binder PS, Bosem M, Weinreb RN. Scheimpflug anterior segment photography assessment of wound healing after myopic excimer laser photorefractive keratectomy. J Cataract Refract Surg. 1996;22:205-212.
    • (1996) J Cataract Refract Surg , vol.22 , pp. 205-212
    • Binder, P.S.1    Bosem, M.2    Weinreb, R.N.3
  • 5
    • 4644352714 scopus 로고    scopus 로고
    • Objective measurements of corneal light-backscatter during corneal swelling, by optical coherence tomography
    • Wang J, Simpson TL, Fonn D. Objective measurements of corneal light-backscatter during corneal swelling, by optical coherence tomography. Invest Ophthalmol Vis Sci. 2004;45:3493-3498.
    • (2004) Invest Ophthalmol Vis Sci , vol.45 , pp. 3493-3498
    • Wang, J.1    Simpson, T.L.2    Fonn, D.3
  • 6
    • 0034038860 scopus 로고    scopus 로고
    • Optical coherence tomography evaluation of the corneal cap and stromal bed features after laser in situ keratomileusis for high myopia and astigmatism
    • Maldonado MJ, Ruiz-Oblitas L, Munuera JM, Aliseda D, Garcia-Layana A, Moreno-Montanes J. Optical coherence tomography evaluation of the corneal cap and stromal bed features after laser in situ keratomileusis for high myopia and astigmatism. Ophthalmology. 2000;107:81-87.
    • (2000) Ophthalmology , vol.107 , pp. 81-87
    • Maldonado, M.J.1    Ruiz-Oblitas, L.2    Munuera, J.M.3    Aliseda, D.4    Garcia-Layana, A.5    Moreno-Montanes, J.6
  • 7
    • 0142139230 scopus 로고    scopus 로고
    • Topographical thickness of the epithelium and total cornea after overnight wear of reverse-geometry rigid contact lenses for myopia reduction
    • Wang J, Fonn D, Simpson TL, Sorbara L, Kort R, Jones L. Topographical thickness of the epithelium and total cornea after overnight wear of reverse-geometry rigid contact lenses for myopia reduction. Invest Ophthalmol Vis Sci. 2003;44:4742-4746.
    • (2003) Invest Ophthalmol Vis Sci , vol.44 , pp. 4742-4746
    • Wang, J.1    Fonn, D.2    Simpson, T.L.3    Sorbara, L.4    Kort, R.5    Jones, L.6
  • 8
    • 0036181034 scopus 로고    scopus 로고
    • The measurement of corneal epithelial thickness in response to hypoxia using optical coherence tomography
    • Wang J, Fonn D, Simpson TL, Jones L. The measurement of corneal epithelial thickness in response to hypoxia using optical coherence tomography. Am J Ophthalmol. 2002;133:315-319.
    • (2002) Am J Ophthalmol , vol.133 , pp. 315-319
    • Wang, J.1    Fonn, D.2    Simpson, T.L.3    Jones, L.4
  • 9
    • 3042580061 scopus 로고    scopus 로고
    • Noncontact measurements of central corneal epithelial and flap thickness after laser in situ keratomileusis
    • Wang J, Thomas J, Cox I, Rollins A. Noncontact measurements of central corneal epithelial and flap thickness after laser in situ keratomileusis. Invest Ophthalmol Vis Sci. 2004;45:1812-1816.
    • (2004) Invest Ophthalmol Vis Sci , vol.45 , pp. 1812-1816
    • Wang, J.1    Thomas, J.2    Cox, I.3    Rollins, A.4
  • 10
    • 0036156562 scopus 로고    scopus 로고
    • Repeatability and reproducibility of macular thickness measurements with the Humphrey OCT system
    • Muscat S, Parks S, Kemp E, Keating D. Repeatability and reproducibility of macular thickness measurements with the Humphrey OCT system. Invest Ophthalmol Vis Sci. 2002;43:490-495.
    • (2002) Invest Ophthalmol Vis Sci , vol.43 , pp. 490-495
    • Muscat, S.1    Parks, S.2    Kemp, E.3    Keating, D.4
  • 12
    • 0037336317 scopus 로고    scopus 로고
    • Topographical thickness of the epithelium and total cornea after hydrogel and PMMA contact lens wear with eye closure
    • Wang J, Fonn D, Simpson TL. Topographical thickness of the epithelium and total cornea after hydrogel and PMMA contact lens wear with eye closure. Invest Ophthalmol Vis Sci. 2003;44:1070-1074.
    • (2003) Invest Ophthalmol Vis Sci , vol.44 , pp. 1070-1074
    • Wang, J.1    Fonn, D.2    Simpson, T.L.3
  • 13
    • 0036295281 scopus 로고    scopus 로고
    • Relation between optical coherence tomography and optical pachymetry measurements of corneal swelling induced by hypoxia
    • Wang J, Fonn D, Simpson TL, Jones L. Relation between optical coherence tomography and optical pachymetry measurements of corneal swelling induced by hypoxia. Am J Ophthalmol. 2002;134:93-98.
    • (2002) Am J Ophthalmol , vol.134 , pp. 93-98
    • Wang, J.1    Fonn, D.2    Simpson, T.L.3    Jones, L.4
  • 14
    • 0035078403 scopus 로고    scopus 로고
    • Super vision: Dream or reality
    • Arbelaez MC. Super vision: dream or reality. J Refract Surg. 2001;17:S211-S218.
    • (2001) J Refract Surg , vol.17
    • Arbelaez, M.C.1
  • 15
    • 0033504309 scopus 로고    scopus 로고
    • Very high-frequency ultrasound corneal analysis identifies anatomic correlates of optical complications of lamellar refractive surgery: Anatomic diagnosis in lamellar surgery
    • Reinstein DZ, Silverman RH, Sutton HF, Coleman DJ. Very high-frequency ultrasound corneal analysis identifies anatomic correlates of optical complications of lamellar refractive surgery: anatomic diagnosis in lamellar surgery. Ophthalmology. 1999;106:474-482.
    • (1999) Ophthalmology , vol.106 , pp. 474-482
    • Reinstein, D.Z.1    Silverman, R.H.2    Sutton, H.F.3    Coleman, D.J.4
  • 17
    • 11144314293 scopus 로고    scopus 로고
    • Continuous monitoring of corneal thickness changes during LASIK with online optical coherence pachymetry
    • Wirbelauer C, Pham DT. Continuous monitoring of corneal thickness changes during LASIK with online optical coherence pachymetry. J Cataract Refract Surg. 2004;30:2559-2568.
    • (2004) J Cataract Refract Surg , vol.30 , pp. 2559-2568
    • Wirbelauer, C.1    Pham, D.T.2
  • 18
    • 0015715693 scopus 로고
    • The distribution of light scattered from the rabbit's cornea
    • Lindstrom JI, Feuk T, Tengroth B. The distribution of light scattered from the rabbit's cornea. Acta Ophthalmol (Copenh). 1973;51:656-669.
    • (1973) Acta Ophthalmol (Copenh) , vol.51 , pp. 656-669
    • Lindstrom, J.I.1    Feuk, T.2    Tengroth, B.3
  • 19
    • 0017159615 scopus 로고
    • On the interpretation of depth dependent light scattering measurements in normal corneas
    • Farrell RA, McCally RL. On the interpretation of depth dependent light scattering measurements in normal corneas. Acta Ophthalmol (Copenh). 1976;54:261-270.
    • (1976) Acta Ophthalmol (Copenh) , vol.54 , pp. 261-270
    • Farrell, R.A.1    McCally, R.L.2
  • 20
    • 0017064059 scopus 로고
    • The depth dependence of light scattering from the normal rabbit cornea
    • McCally RL, Farrell RA. The depth dependence of light scattering from the normal rabbit cornea. Exp Eye Res. 1976;23:69-81.
    • (1976) Exp Eye Res , vol.23 , pp. 69-81
    • McCally, R.L.1    Farrell, R.A.2
  • 21
    • 0028942778 scopus 로고
    • Refractive index of the human corneal epithelium and stroma
    • Patel S, Marshall J, Fitzke FW. Refractive index of the human corneal epithelium and stroma. J Refract Surg. 1995;11:100-105.
    • (1995) J Refract Surg , vol.11 , pp. 100-105
    • Patel, S.1    Marshall, J.2    Fitzke, F.W.3
  • 22
    • 0023604820 scopus 로고
    • Refractive index of the mammalian cornea and its influence during pachometry
    • Patel S. Refractive index of the mammalian cornea and its influence during pachometry. Ophthalmic Physiol Opt. 1987;7:503-506.
    • (1987) Ophthalmic Physiol Opt , vol.7 , pp. 503-506
    • Patel, S.1
  • 23
    • 0014861448 scopus 로고
    • Uneven swelling of the corneal stroma
    • Kikkawa Y, Hirayama K. Uneven swelling of the corneal stroma. Invest Ophthalmol. 1970;9:735-741.
    • (1970) Invest Ophthalmol , vol.9 , pp. 735-741
    • Kikkawa, Y.1    Hirayama, K.2
  • 25
    • 0036271439 scopus 로고    scopus 로고
    • In vivo confocal microscopy through-focusing to measure corneal flap thickness after laser in situ keratomileusis
    • Gokmen F, Jester JV, Petroll WM, McCulley JP, Cavanagh HD. In vivo confocal microscopy through-focusing to measure corneal flap thickness after laser in situ keratomileusis. J Cataract Refract Surg. 2002;28:962-970.
    • (2002) J Cataract Refract Surg , vol.28 , pp. 962-970
    • Gokmen, F.1    Jester, J.V.2    Petroll, W.M.3    McCulley, J.P.4    Cavanagh, H.D.5
  • 26
    • 0034115187 scopus 로고    scopus 로고
    • Role of the corneal epithelium in refractive changes following laser in situ keratomileusis for high myopia
    • Spadea L, Fasciani R, Necozione S, Balestrazzi E. Role of the corneal epithelium in refractive changes following laser in situ keratomileusis for high myopia. J Refract Surg. 2000;16:133-139.
    • (2000) J Refract Surg , vol.16 , pp. 133-139
    • Spadea, L.1    Fasciani, R.2    Necozione, S.3    Balestrazzi, E.4
  • 29
    • 18844387066 scopus 로고    scopus 로고
    • Factors predictive of LASIK flap thickness with the Hansatome zero compression microkeratome
    • Choudhri SA, Feigenbaum SK, Pepose JS. Factors predictive of LASIK flap thickness with the Hansatome zero compression microkeratome. J Refract Surg. 2005;21:253-259.
    • (2005) J Refract Surg , vol.21 , pp. 253-259
    • Choudhri, S.A.1    Feigenbaum, S.K.2    Pepose, J.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.