메뉴 건너뛰기




Volumn 112, Issue 11, 2013, Pages 1800-1806

Multidetector row computed tomography parameters associated with paravalvular regurgitation after transcatheter aortic valve implantation

Author keywords

[No Author keywords available]

Indexed keywords

AGED; AORTA ROOT; AORTA VALVE REGURGITATION; AORTA VALVE REPLACEMENT; ARTICLE; BALLOON DILATATION; CLINICAL EVALUATION; COMPUTED TOMOGRAPHY SCANNER; CORONARY ARTERY DISEASE; DIABETES MELLITUS; ECHOCARDIOGRAPH; FEMALE; FOLLOW UP; HEART ATRIUM FIBRILLATION; HEART LEFT VENTRICLE EJECTION FRACTION; HEART LEFT VENTRICLE ENDDIASTOLIC VOLUME; HEART LEFT VENTRICLE ENDSYSTOLIC VOLUME; HEART LEFT VENTRICLE OUTFLOW TRACT; HUMAN; HYPERTENSION; MAJOR CLINICAL STUDY; MALE; MULTIDETECTOR COMPUTED TOMOGRAPHY; PARAVALVULAR AORTA REGURGITATION; PERCUTANEOUS AORTIC VALVE; PERIPHERAL VASCULAR DISEASE; PRIORITY JOURNAL; SENSITIVITY AND SPECIFICITY; SMOKING; TRANSCATHETER AORTIC VALVE IMPLANTATION; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; TRANSTHORACIC ECHOCARDIOGRAPHY; ULTRASOUND SCANNER;

EID: 84888007613     PISSN: 00029149     EISSN: 18791913     Source Type: Journal    
DOI: 10.1016/j.amjcard.2013.07.049     Document Type: Article
Times cited : (17)

References (27)
  • 1
    • 84862181480 scopus 로고    scopus 로고
    • Clinical outcomes after transcatheter aortic valve replacement using valve academic research consortium definitions: A weighted meta-analysis of 3,519 patients from 16 studies
    • P. Généreux, S.J. Head, N.M. Van Mieghem, S. Kodali, A.J. Kirtane, K. Xu, C. Smith, P.W. Serruys, A.P. Kappetein, and M.B. Leon Clinical outcomes after transcatheter aortic valve replacement using valve academic research consortium definitions: a weighted meta-analysis of 3,519 patients from 16 studies J Am Coll Cardiol 59 2012 2317 2326
    • (2012) J Am Coll Cardiol , vol.59 , pp. 2317-2326
    • Généreux, P.1    Head, S.J.2    Van Mieghem, N.M.3    Kodali, S.4    Kirtane, A.J.5    Xu, K.6    Smith, C.7    Serruys, P.W.8    Kappetein, A.P.9    Leon, M.B.10
  • 6
    • 84859164235 scopus 로고    scopus 로고
    • Cross-sectional computed tomographic assessment improves accuracy of aortic annular sizing for transcatheter aortic valve replacement and reduces the incidence of paravalvular aortic regurgitation
    • H. Jilaihawi, M. Kashif, G. Fontana, A. Furugen, T. Shiota, G. Friede, R. Makhija, N. Doctor, M.B. Leon, and R.R. Makkar Cross-sectional computed tomographic assessment improves accuracy of aortic annular sizing for transcatheter aortic valve replacement and reduces the incidence of paravalvular aortic regurgitation J Am Coll Cardiol 59 2012 1275 1286
    • (2012) J Am Coll Cardiol , vol.59 , pp. 1275-1286
    • Jilaihawi, H.1    Kashif, M.2    Fontana, G.3    Furugen, A.4    Shiota, T.5    Friede, G.6    Makhija, R.7    Doctor, N.8    Leon, M.B.9    Makkar, R.R.10
  • 12
  • 17
    • 70349396032 scopus 로고    scopus 로고
    • Determinants of significant paravalvular regurgitation after transcatheter aortic valve: Implantation impact of device and annulus discongruence
    • D. Detaint, L. Lepage, D. Himbert, E. Brochet, D. Messika-Zeitoun, B. Iung, and A. Vahanian Determinants of significant paravalvular regurgitation after transcatheter aortic valve: implantation impact of device and annulus discongruence JACC Cardiovasc Interv 2 2009 821 827
    • (2009) JACC Cardiovasc Interv , vol.2 , pp. 821-827
    • Detaint, D.1    Lepage, L.2    Himbert, D.3    Brochet, E.4    Messika-Zeitoun, D.5    Iung, B.6    Vahanian, A.7
  • 19
    • 80055011535 scopus 로고    scopus 로고
    • Transesophageal echocardiographic scoring for transcatheter aortic valve implantation: Impact of aortic cusp calcification on postoperative aortic regurgitation
    • A. Colli, R. D'Amico, J. Kempfert, M.A. Borger, F.W. Mohr, and T. Walther Transesophageal echocardiographic scoring for transcatheter aortic valve implantation: impact of aortic cusp calcification on postoperative aortic regurgitation J Thorac Cardiovasc Surg 142 2011 1229 1235
    • (2011) J Thorac Cardiovasc Surg , vol.142 , pp. 1229-1235
    • Colli, A.1    D'Amico, R.2    Kempfert, J.3    Borger, M.A.4    Mohr, F.W.5    Walther, T.6
  • 23
    • 77950526783 scopus 로고    scopus 로고
    • Prosthesis-patient mismatch after transcatheter aortic valve implantation with the Medtronic-Corevalve bioprosthesis
    • H. Jilaihawi, D. Chin, T. Spyt, M. Jeilan, M. Vasa-Nicotera, J. Bence, E. Logtens, and J. Kovac Prosthesis-patient mismatch after transcatheter aortic valve implantation with the Medtronic-Corevalve bioprosthesis Eur Heart J 31 2010 857 864
    • (2010) Eur Heart J , vol.31 , pp. 857-864
    • Jilaihawi, H.1    Chin, D.2    Spyt, T.3    Jeilan, M.4    Vasa-Nicotera, M.5    Bence, J.6    Logtens, E.7    Kovac, J.8
  • 24
    • 78751655791 scopus 로고    scopus 로고
    • Anatomic and procedural predictors of paravalvular aortic regurgitation after implantation of the Medtronic CoreValve bioprosthesis
    • M.A. Sherif, M. Abdel-Wahab, B. Stocker, V. Geist, D. Richardt, R. Tolg, and G. Richardt Anatomic and procedural predictors of paravalvular aortic regurgitation after implantation of the Medtronic CoreValve bioprosthesis J Am Coll Cardiol 56 2010 1623 1629
    • (2010) J Am Coll Cardiol , vol.56 , pp. 1623-1629
    • Sherif, M.A.1    Abdel-Wahab, M.2    Stocker, B.3    Geist, V.4    Richardt, D.5    Tolg, R.6    Richardt, G.7
  • 27
    • 69549087044 scopus 로고    scopus 로고
    • Recommendations for evaluation of prosthetic valves with echocardiography and doppler ultrasound
    • A report from the American Society of Echocardiography's Guidelines and Standards Committee and the Task Force on Prosthetic Valves, developed in conjunction with the American College of Cardiology Cardiovascular Imaging Committee, Cardiac Imaging Committee of the American Heart Association, the European Association of Echocardiography, a registered branch of the European Society of Cardiology, the Japanese Society of Echocardiography and the Canadian Society of Echocardiography, endorsed by the American College of Cardiology Foundation, American Heart Association, European Association of Echocardiography, a registered branch of the European Society of Cardiology, the Japanese Society of Echocardiography, and Canadian Society of Echocardiography
    • W.A. Zoghbi, J.B. Chambers, J.G. Dumesnil, E. Foster, J.S. Gottdiener, P.A. Grayburn, B.K. Khandheria, R.A. Levine, G.R. Marx, F.A. Miller Jr., S. Nakatani, M.A. Quinones, H. Rakowski, L.L. Rodriguez, M. Swaminathan, A.D. Waggoner, N.J. Weissman, and M. Zabalgoitia Recommendations for evaluation of prosthetic valves with echocardiography and doppler ultrasound: a report From the American Society of Echocardiography's Guidelines and Standards Committee and the Task Force on Prosthetic Valves, developed in conjunction with the American College of Cardiology Cardiovascular Imaging Committee, Cardiac Imaging Committee of the American Heart Association, the European Association of Echocardiography, a registered branch of the European Society of Cardiology, the Japanese Society of Echocardiography and the Canadian Society of Echocardiography, endorsed by the American College of Cardiology Foundation, American Heart Association, European Association of Echocardiography, a registered branch of the European Society of Cardiology, the Japanese Society of Echocardiography, and Canadian Society of Echocardiography J Am Soc Echocardiogr 22 2009 975 1014
    • (2009) J Am Soc Echocardiogr , vol.22 , pp. 975-1014
    • Zoghbi, W.A.1    Chambers, J.B.2    Dumesnil, J.G.3    Foster, E.4    Gottdiener, J.S.5    Grayburn, P.A.6    Khandheria, B.K.7    Levine, R.A.8    Marx, G.R.9    Miller, Jr.F.A.10    Nakatani, S.11    Quinones, M.A.12    Rakowski, H.13    Rodriguez, L.L.14    Swaminathan, M.15    Waggoner, A.D.16    Weissman, N.J.17    Zabalgoitia, M.18


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.