메뉴 건너뛰기




Volumn 5, Issue 5, 2012, Pages 525-532

Structural integrity of balloon-expandable stents after transcatheter aortic valve replacement: Assessment by multidetector computed tomography

Author keywords

aortic stenosis; multidetector computed tomography; transcatheter aortic valve implantation; transcatheter aortic valve replacement

Indexed keywords

AGED; AORTA VALVE PROSTHESIS; ARTICLE; CLINICAL ARTICLE; CONTROLLED STUDY; ECHOCARDIOGRAPHY; FEMALE; HEMODYNAMICS; HUMAN; IMPLANTATION; MALE; MULTIDETECTOR COMPUTED TOMOGRAPHY; PRIORITY JOURNAL; STENT; TRANSCATHETER AORTIC VALVE IMPLANTATION;

EID: 84861549775     PISSN: 19368798     EISSN: 18767605     Source Type: Journal    
DOI: 10.1016/j.jcin.2012.03.007     Document Type: Article
Times cited : (61)

References (17)
  • 1
    • 1542613967 scopus 로고    scopus 로고
    • Late incidence and determinants of reoperation in patients with prosthetic heart valves
    • M. Ruel, A. Kulik, F.D. Rubens Late incidence and determinants of reoperation in patients with prosthetic heart valves Eur J Cardiothorac Surg 25 2004 364 370
    • (2004) Eur J Cardiothorac Surg , vol.25 , pp. 364-370
    • Ruel, M.1    Kulik, A.2    Rubens, F.D.3
  • 2
    • 0035137190 scopus 로고    scopus 로고
    • Reoperation for prosthetic aortic valve obstruction in the era of echocardiography: Trends in diagnostic testing and comparison with surgical findings
    • S.E. Girard, F.A.J. Miller, T.A. Orszulak Reoperation for prosthetic aortic valve obstruction in the era of echocardiography: trends in diagnostic testing and comparison with surgical findings J Am Coll Cardiol 37 2001 579 584
    • (2001) J Am Coll Cardiol , vol.37 , pp. 579-584
    • Girard, S.E.1    Miller, F.A.J.2    Orszulak, T.A.3
  • 3
    • 67649532220 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation: Impact on clinical and valve-related outcomes
    • J.G. Webb, L. Altwegg, R.H. Boone Transcatheter aortic valve implantation: impact on clinical and valve-related outcomes Circulation 119 2009 3009 3016
    • (2009) Circulation , vol.119 , pp. 3009-3016
    • Webb, J.G.1    Altwegg, L.2    Boone, R.H.3
  • 4
    • 77957945557 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation: Durability of clinical and hemodynamic outcomes beyond 3 years in a large patient cohort
    • R. Gurvitch, D.A. Wood, E.L. Tay Transcatheter aortic valve implantation: durability of clinical and hemodynamic outcomes beyond 3 years in a large patient cohort Circulation 122 2010 1319 1327
    • (2010) Circulation , vol.122 , pp. 1319-1327
    • Gurvitch, R.1    Wood, D.A.2    Tay, E.L.3
  • 5
    • 79953856919 scopus 로고    scopus 로고
    • 2-year follow-up of patients undergoing transcatheter aortic valve implantation using a self-expanding valve prosthesis
    • L. Buellesfeld, U. Gerckens, G. Schuler 2-year follow-up of patients undergoing transcatheter aortic valve implantation using a self-expanding valve prosthesis J Am Coll Cardiol 57 2011 1650 1657
    • (2011) J Am Coll Cardiol , vol.57 , pp. 1650-1657
    • Buellesfeld, L.1    Gerckens, U.2    Schuler, G.3
  • 6
    • 38349136447 scopus 로고    scopus 로고
    • Is it reasonable to treat all calcified stenotic aortic valves with a valved stent? Results from a human anatomic study in adults
    • R. Zegdi, V. Ciobotaru, M. Noghin Is it reasonable to treat all calcified stenotic aortic valves with a valved stent? Results from a human anatomic study in adults J Am Coll Cardiol 51 2008 579 584
    • (2008) J Am Coll Cardiol , vol.51 , pp. 579-584
    • Zegdi, R.1    Ciobotaru, V.2    Noghin, M.3
  • 7
    • 76749129375 scopus 로고    scopus 로고
    • Increased radial force improves stent deployment in tricuspid but not in bicuspid stenotic native aortic valves
    • R. Zegdi, L. Lecuyer, P. Achouh Increased radial force improves stent deployment in tricuspid but not in bicuspid stenotic native aortic valves Ann Thorac Surg 89 2010 768 772
    • (2010) Ann Thorac Surg , vol.89 , pp. 768-772
    • Zegdi, R.1    Lecuyer, L.2    Achouh, P.3
  • 8
    • 0033027393 scopus 로고    scopus 로고
    • Distortion of the stentless porcine valve induces accelerated leaflet fibrosis and calcification in juvenile sheep
    • G. van Nooten, S. Ozaki, P. Herijgers, P. Segers, P. Verdonck, W. Flameng Distortion of the stentless porcine valve induces accelerated leaflet fibrosis and calcification in juvenile sheep J Heart Valve Dis 8 1999 34 41
    • (1999) J Heart Valve Dis , vol.8 , pp. 34-41
    • Van Nooten, G.1    Ozaki, S.2    Herijgers, P.3    Segers, P.4    Verdonck, P.5    Flameng, W.6
  • 9
    • 78651337155 scopus 로고    scopus 로고
    • Standardized endpoint definitions for Transcatheter Aortic Valve Implantation clinical trials: A consensus report from the Valve Academic Research Consortium
    • M.B. Leon, N. Piazza, E. Nikolsky Standardized endpoint definitions for Transcatheter Aortic Valve Implantation clinical trials: a consensus report from the Valve Academic Research Consortium J Am Coll Cardiol 57 2011 253 269
    • (2011) J Am Coll Cardiol , vol.57 , pp. 253-269
    • Leon, M.B.1    Piazza, N.2    Nikolsky, E.3
  • 10
    • 40849143896 scopus 로고    scopus 로고
    • Office for Official Publications of, European Communities Luxembourg Accessed October 15, 2011
    • G. Bongartz, S.J. Golding, A.G. Jurik 2004: Appendix C: European Guidelines for Multislice Computed Tomography 2004 Office for Official Publications of, European Communities Luxembourg http://w3.tue.nl/fileadmin/sbd/ Documenten/Leergang/BSM/European-Guidelines-Quality-Criteria-Computed- Tomography-Eur-16252.pdf Accessed October 15, 2011
    • (2004) 2004: Appendix C: European Guidelines for Multislice Computed Tomography
    • Bongartz, G.1    Golding, S.J.2    Jurik, A.G.3
  • 11
    • 79954492455 scopus 로고    scopus 로고
    • Multidetector computed tomography in transcatheter aortic valve implantation
    • J. Leipsic, R. Gurvitch, T.M. Labounty Multidetector computed tomography in transcatheter aortic valve implantation J Am Coll Cardiol Img 4 2011 416 429
    • (2011) J Am Coll Cardiol Img , vol.4 , pp. 416-429
    • Leipsic, J.1    Gurvitch, R.2    Labounty, T.M.3
  • 12
    • 84859160648 scopus 로고    scopus 로고
    • 3-dimensional aortic annular assessment by multidetector computed tomography predicts moderate or severe paravalvular regurgitation after transcatheter aortic valve replacement: A multicenter retrospective analysis
    • A.B. Willson, J.G. Webb, T.M. LaBounty 3-dimensional aortic annular assessment by multidetector computed tomography predicts moderate or severe paravalvular regurgitation after transcatheter aortic valve replacement: a multicenter retrospective analysis J Am Coll Cardiol 59 2012 1287 1294
    • (2012) J Am Coll Cardiol , vol.59 , pp. 1287-1294
    • Willson, A.B.1    Webb, J.G.2    Labounty, T.M.3
  • 13
    • 33746209047 scopus 로고    scopus 로고
    • Structural deterioration of the Freestyle aortic valve: Mode of presentation and mechanisms
    • S. Mohammadi, R. Baillot, P. Voisine, P. Mathieu, F. Dagenais Structural deterioration of the Freestyle aortic valve: mode of presentation and mechanisms J Thorac Cardiovasc Surg 132 2006 401 406
    • (2006) J Thorac Cardiovasc Surg , vol.132 , pp. 401-406
    • Mohammadi, S.1    Baillot, R.2    Voisine, P.3    Mathieu, P.4    Dagenais, F.5
  • 14
    • 77952027747 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation: Role of multi-detector row computed tomography to evaluate prosthesis positioning and deployment in relation to valve function
    • V. Delgado, A.C. Ng, N.R. van de Veire Transcatheter aortic valve implantation: role of multi-detector row computed tomography to evaluate prosthesis positioning and deployment in relation to valve function Eur Heart J 31 2010 1114 1123
    • (2010) Eur Heart J , vol.31 , pp. 1114-1123
    • Delgado, V.1    Ng, A.C.2    Van De Veire, N.R.3
  • 15
    • 68949174075 scopus 로고    scopus 로고
    • Geometry and degree of apposition of the CoreValve ReValving system with multislice computed tomography after implantation in patients with aortic stenosis
    • C.J. Schultz, A. Weustink, N. Piazza Geometry and degree of apposition of the CoreValve ReValving system with multislice computed tomography after implantation in patients with aortic stenosis J Am Coll Cardiol 54 2009 911 918
    • (2009) J Am Coll Cardiol , vol.54 , pp. 911-918
    • Schultz, C.J.1    Weustink, A.2    Piazza, N.3
  • 16
    • 77956644217 scopus 로고    scopus 로고
    • A clinical protocol for analysis of the structural integrity of the Medtronic CoreValve System frame and its application in patients with 1-year minimum follow-up
    • N. Piazza, E. Grube, U. Gerckens A clinical protocol for analysis of the structural integrity of the Medtronic CoreValve System frame and its application in patients with 1-year minimum follow-up EuroIntervention 5 2010 680 686
    • (2010) EuroIntervention , vol.5 , pp. 680-686
    • Piazza, N.1    Grube, E.2    Gerckens, U.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.