메뉴 건너뛰기




Volumn 8, Issue 10, 2013, Pages 659-663

Enhancing fluorescent response of immunosensing by a dielectrophoresis chip with transparent electrodes and microcavities array

Author keywords

[No Author keywords available]

Indexed keywords

BACKGROUND NOISE; BOVINE SERUM ALBUMINS; DIELECTROPHORESIS CHIP; FLUORESCENT RESPONSE; INDIUM TIN OXIDE; METAL ELECTRODES; TRANSPARENT CONDUCTIVE MATERIALS; TRANSPARENT ELECTRODE;

EID: 84887112643     PISSN: None     EISSN: 17500443     Source Type: Journal    
DOI: 10.1049/mnl.2013.0439     Document Type: Conference Paper
Times cited : (7)

References (15)
  • 1
    • 47749155595 scopus 로고    scopus 로고
    • Microfluidic immunosensor design for the quantification of interleukin-6 in human serum samples
    • Raba J., Messina G.A., Panini N.V., Martinez N.A.: 'Microfluidic immunosensor design for the quantification of interleukin-6 in human serum samples', Anal. Biochem., 2008, 380, pp. 262-267
    • (2008) Anal Biochem , vol.380 , pp. 262-267
    • Raba, J.1    Messina, G.A.2    Panini, N.V.3    Martinez, N.A.4
  • 2
    • 84870836627 scopus 로고    scopus 로고
    • Ultrasensitive detection of E. Coli O157:H7 with biofunctional magnetic bead concentration via nanoporous membrane based electrochemical immunosensor
    • Chan K.Y., Ye W.W., Zhang Y.et al..: 'Ultrasensitive detection of E. coli O157:H7 with biofunctional magnetic bead concentration via nanoporous membrane based electrochemical immunosensor', Biosens. Bioelectron., 2013, 41, pp. 532-537
    • (2013) Biosens Bioelectron , vol.41 , pp. 532-537
    • Chan, K.Y.1    Ye, W.W.2    Zhang, Y.3
  • 3
    • 84864287318 scopus 로고    scopus 로고
    • Optimization and application of a dithiobis-succinimidyl propionate-modified immunosensor platform to detect Listeria monocytogenes in chicken skin
    • Park M.K., Park J.W., Oh J.H.: 'Optimization and application of a dithiobis-succinimidyl propionate-modified immunosensor platform to detect Listeria monocytogenes in chicken skin', Sens. Actuator B, Chem., 2012, 171-172, pp. 323-331
    • (2012) Sens. Actuator B Chem , vol.171-172 , pp. 323-331
    • Park, M.K.1    Park, J.W.2    Oh, J.H.3
  • 4
    • 84871648980 scopus 로고    scopus 로고
    • Microfluidic beads-based immunosensor for sensitive detection of cancer biomarker proteins using multienzyme-nanoparticle amplification and quantum dots labels
    • Zhang H., Liu L., Fu X., Zhu Z.: 'Microfluidic beads-based immunosensor for sensitive detection of cancer biomarker proteins using multienzyme- nanoparticle amplification and quantum dots labels', Biosens. Bioelectron., 2013, 42, pp. 23-30
    • (2013) Biosens Bioelectron , vol.42 , pp. 23-30
    • Zhang, H.1    Liu, L.2    Fu, X.3    Zhu, Z.4
  • 5
    • 79957962047 scopus 로고    scopus 로고
    • Integration of fiber opticparticle plasmon resonance biosensor with microfluidic chip
    • Hsu W.T., Hsieh W.H., Cheng S.F.et al..: 'Integration of fiber opticparticle plasmon resonance biosensor with microfluidic chip', Anal. Chim. Acta, 2011, 697, pp. 75-82
    • (2011) Anal. Chim. Acta , vol.697 , pp. 75-82
    • Hsu, W.T.1    Hsieh, W.H.2    Cheng, S.F.3
  • 6
    • 84855940883 scopus 로고    scopus 로고
    • Automated microfluidic processing platform for multiplexed magnetic bead immunoassays
    • Lee S.H.S., Hatton T.A., Khan S.A.: 'Automated microfluidic processing platform for multiplexed magnetic bead immunoassays', Microfluid. Nanofluid., 2011, 11, pp. 429-438
    • (2011) Microfluid Nanofluid , vol.11 , pp. 429-438
    • Lee, S.H.S.1    Hatton, T.A.2    Khan, S.A.3
  • 7
  • 8
    • 84870777027 scopus 로고    scopus 로고
    • An integrated chip capable of performing sample pretreatment and nucleic acid amplification for HIV-1 detection
    • Wang J.H., Cheng L., Wang C.H., Ling W.S., Wang S.W., Lee G.B.: 'An integrated chip capable of performing sample pretreatment and nucleic acid amplification for HIV-1 detection', Biosens. Bioelectron., 2013, 41, pp. 484-491
    • (2013) Biosens Bioelectron , vol.41 , pp. 484-491
    • Wang, J.H.1    Cheng, L.2    Wang, C.H.3    Ling, W.S.4    Wang, S.W.5    Lee, G.B.6
  • 9
    • 84862779330 scopus 로고    scopus 로고
    • Gold nano-particle-based thermal sensors fabricated using microspotting and DEP techniques
    • Leung S.L., Li M., Li W.J., Mai J.D.: 'Gold nano-particle-based thermal sensors fabricated using microspotting and DEP techniques', Sens. Actuator A, Phys., 2012, 178, pp. 32-39
    • (2012) Sens. Actuator A Phys , vol.178 , pp. 32-39
    • Leung, S.L.1    Li, M.2    Li, W.J.3    Mai, J.D.4
  • 10
    • 84862796764 scopus 로고    scopus 로고
    • Capacitive humidity sensors based on the dielectrophoretically manipulated ZnO nanorods
    • Chen L., Zhang J.: 'Capacitive humidity sensors based on the dielectrophoretically manipulated ZnO nanorods', Sens. Actuator A, Phys., 2012, 178, pp. 88-93
    • (2012) Sens. Actuator A Phys , vol.178 , pp. 88-93
    • Chen, L.1    Zhang, J.2
  • 11
    • 77957686858 scopus 로고    scopus 로고
    • Enhancement of specific cell-capture efficiency using a reversible dielectrophoresis field
    • Shew B.Y., Chu H.C., Chen C.K.et al..: 'Enhancement of specific cell-capture efficiency using a reversible dielectrophoresis field', Sens. Actuator A, Phys., 2010, 163, pp. 128-137
    • (2010) Sens. Actuator A Phys , vol.163 , pp. 128-137
    • Shew, B.Y.1    Chu, H.C.2    Chen, C.K.3
  • 12
    • 84871668306 scopus 로고    scopus 로고
    • Rapid and ultrasensitive Salmonella Typhimurium quantification using positive dielectrophoresis driven on-line enrichment and fluorescent nanoparticles label
    • He X., Hu C., Guo Q., Wang K., Li Y., Shangguan J.: 'Rapid and ultrasensitive Salmonella Typhimurium quantification using positive dielectrophoresis driven on-line enrichment and fluorescent nanoparticles label', Biosens. Bioelectron., 2013, 42, pp. 460-466
    • (2013) Biosens Bioelectron , vol.42 , pp. 460-466
    • He, X.1    Hu, C.2    Guo, Q.3    Wang, K.4    Li, Y.5    Shangguan, J.6
  • 13
    • 33750320070 scopus 로고    scopus 로고
    • Fabrication of a highly sensitive sensor electrode using a nano-gapped gold particle film
    • Tokonami S., Iwamoto M., Hashiba K., Shiigi H., Nagaoka T.: 'Fabrication of a highly sensitive sensor electrode using a nano-gapped gold particle film', Solid State Ion., 2006, 177, pp. 2317-2320
    • (2006) Solid State Ion , vol.177 , pp. 2317-2320
    • Tokonami, S.1    Iwamoto, M.2    Hashiba, K.3    Shiigi, H.4    Nagaoka, T.5
  • 14
    • 84865461578 scopus 로고    scopus 로고
    • Condensation of fluorescent nanoparticles using a DEP chip with a dot-electrode array
    • Chuang C.H., Huang Y.W.: 'Condensation of fluorescent nanoparticles using a DEP chip with a dot-electrode array', Microelectron. Eng., 2012, 97, pp. 317-323
    • (2012) Microelectron Eng , vol.97 , pp. 317-323
    • Chuang, C.H.1    Huang, Y.W.2
  • 15
    • 77649342337 scopus 로고    scopus 로고
    • Competitive multiimmunosensing of pesticides based on the particle manipulation with negative dielectrophoresis
    • Ramón-Azcón J., Yasukawa T., Lee H.J.et al..: 'Competitive multiimmunosensing of pesticides based on the particle manipulation with negative dielectrophoresis', Biosens. Bioelectron., 2010, 25, pp. 1928-1933
    • (2010) Biosens Bioelectron , vol.25 , pp. 1928-1933
    • Ramón-Azcón, J.1    Yasukawa, T.2    Lee, H.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.