Volumn 117, Issue 5, 2013, Pages 1110-1118

Closed-loop fluid resuscitation: Robustness against weight and cardiac contractility variations

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; BLOOD VOLUME; BODY SIZE; BODY WEIGHT; CONTROLLED STUDY; DISEASE SEVERITY; FLUID RESUSCITATION; HEART FAILURE; HEART MUSCLE CONTRACTILITY; HEMODYNAMICS; HUMAN; MEDICAL ERROR; PRIORITY JOURNAL; SIMULATION; ANESTHESIOLOGY; BIOLOGICAL MODEL; BLOOD PRESSURE; COMPUTER PROGRAM; COMPUTER SIMULATION; DEVICES; DRUG EFFECTS; FEEDBACK SYSTEM; FLUID THERAPY; HEART CONTRACTION; HEART OUTPUT; MONTE CARLO METHOD; PATIENT MONITORING; PROCEDURES; RANDOMIZATION; REPRODUCIBILITY; RESUSCITATION;

EID: 84887072947     PISSN: 00032999     EISSN: 15267598     Source Type: Journal    
DOI: 10.1213/ANE.0b013e3182930050     Document Type: Article
Times cited : (41)

References (29)
  • 1
    • 79958110885 scopus 로고    scopus 로고
    • A systematic review and meta-analysis on the use of preemptive hemodynamic intervention to improve postoperative outcomes in moderate and high-risk surgical patients
    • Hamilton MA, Cecconi M, Rhodes A. A systematic review and meta-analysis on the use of preemptive hemodynamic intervention to improve postoperative outcomes in moderate and high-risk surgical patients. Anesth Analg 2011;112:1392-402
    • (2011) Anesth Analg , vol.112 , pp. 1392-1402
    • Hamilton, M.A.1    Cecconi, M.2    Rhodes, A.3
  • 4
    • 84887097230 scopus 로고    scopus 로고
    • Department of Health, N.I.E.D, ed., in NHS Chief Executive Innovation Review-Call for Evidence and Ideas UK Life Sciences Strategy. Baltimore, MD: Department of Health
    • Department of Health, N.I.E.D, ed. Innovation and Service Improvement, Innovation Health and Wealth, Accelerating Adoption and Diffusion in the NHS, in NHS Chief Executive Innovation Review-Call for Evidence and Ideas UK Life Sciences Strategy. Baltimore, MD: Department of Health, 2011
    • (2011) Innovation and Service Improvement, Innovation Health and Wealth, Accelerating Adoption and Diffusion in the NHS
  • 5
    • 80051578300 scopus 로고    scopus 로고
    • Hemodynamic monitoring and management in patients undergoing high risk surgery: A survey among North American and European anesthesiologists
    • Cannesson M, Pestel G, Ricks C, Hoeft A, Perel A. Hemodynamic monitoring and management in patients undergoing high risk surgery: a survey among North American and European anesthesiologists. Crit Care 2011;15:R197
    • (2011) Crit Care , vol.15
    • Cannesson, M.1    Pestel, G.2    Ricks, C.3    Hoeft, A.4    Perel, A.5
  • 6
    • 79958084056 scopus 로고    scopus 로고
    • Poor adoption of hemodynamic optimization during major surgery: Are we practicing substandard care?
    • Miller TE, Roche AM, Gan TJ. Poor adoption of hemodynamic optimization during major surgery: are we practicing substandard care? Anesth Analg 2011;112:1274-6
    • (2011) Anesth Analg , vol.112 , pp. 1274-1276
    • Miller, T.E.1    Roche, A.M.2    Gan, T.J.3
  • 7
    • 84655169110 scopus 로고    scopus 로고
    • Review article: Closed-loop systems in anesthesia: Is there a potential for closed-loop fluid management and hemodynamic optimization?
    • Rinehart J, Liu N, Alexander B, Cannesson M. Review article: closed-loop systems in anesthesia: is there a potential for closed-loop fluid management and hemodynamic optimization? Anesth Analg 2012;114:130-43
    • (2012) Anesth Analg , vol.114 , pp. 130-143
    • Rinehart, J.1    Liu, N.2    Alexander, B.3    Cannesson, M.4
  • 8
    • 67651162105 scopus 로고    scopus 로고
    • Hemodynamic changes during resuscitation after burns using the Parkland formula
    • Bak Z, Sjöberg F, Eriksson O, Steinvall I, Janerot-Sjoberg B. Hemodynamic changes during resuscitation after burns using the Parkland formula. J Trauma 2009;66:329-36
    • (2009) J Trauma , vol.66 , pp. 329-336
    • Bak, Z.1    Sjöberg, F.2    Eriksson, O.3    Steinvall, I.4    Janerot-Sjoberg, B.5
  • 9
    • 84860631271 scopus 로고    scopus 로고
    • Perioperative fluid therapy
    • Pearse RM, Ackland GL. Perioperative fluid therapy. BMJ 2012;344:e2865
    • (2012) BMJ , vol.344
    • Pearse, R.M.1    Ackland, G.L.2
  • 10
    • 81555236009 scopus 로고    scopus 로고
    • Evaluation of a novel closed-loop fluid-administration system based on dynamic predictors of fluid responsiveness: An in silico simulation study
    • Rinehart J, Alexander B, Le Manach Y, Hofer C, Tavernier B, Kain ZN, Cannesson M. Evaluation of a novel closed-loop fluid-administration system based on dynamic predictors of fluid responsiveness: an in silico simulation study. Crit Care 2011;15:R278
    • (2011) Crit Care , vol.15
    • Rinehart, J.1    Alexander, B.2    Le Manach, Y.3    Hofer, C.4    Tavernier, B.5    Kain, Z.N.6    Cannesson, M.7
  • 11
    • 84865733328 scopus 로고    scopus 로고
    • Intraoperative stroke volume optimization using stroke volume, arterial pressure, and heart rate: Closed-loop (learning intravenous resuscitator) versus anesthesiologists
    • Rinehart J, Chung E, Canales C, Cannesson M. Intraoperative stroke volume optimization using stroke volume, arterial pressure, and heart rate: closed-loop (learning intravenous resuscitator) versus anesthesiologists. J Cardiothorac Vasc Anesth 2012;26:933-9
    • (2012) J Cardiothorac Vasc Anesth , vol.26 , pp. 933-939
    • Rinehart, J.1    Chung, E.2    Canales, C.3    Cannesson, M.4
  • 12
    • 23044492936 scopus 로고    scopus 로고
    • Pharmacokinetic-pharmacodynamic modelling of the cardiovascular effects of drugs-method development and application to magnesium in sheep
    • Upton RN, Ludbrook GL. Pharmacokinetic-pharmacodynamic modelling of the cardiovascular effects of drugs-method development and application to magnesium in sheep. BMC Pharmacol 2005;5:5
    • (2005) BMC Pharmacol , vol.5 , pp. 5
    • Upton, R.N.1    Ludbrook, G.L.2
  • 14
    • 23044496343 scopus 로고    scopus 로고
    • A physiologically based, recirculatory model of the kinetics and dynamics of propofol in man
    • Upton RN, Ludbrook G. A physiologically based, recirculatory model of the kinetics and dynamics of propofol in man. Anesthesiology 2005;103:344-52
    • (2005) Anesthesiology , vol.103 , pp. 344-352
    • Upton, R.N.1    Ludbrook, G.2
  • 15
    • 77954665226 scopus 로고    scopus 로고
    • Fluid and blood resuscitation
    • Tintinalli J, ed.. New York, NY: McGraw-Hill
    • Manning J. Fluid and blood resuscitation. In: Tintinalli J, ed. Emergency Medicine: A Comprehensive Study Guide. New York, NY: McGraw-Hill, 2004:227
    • (2004) Emergency Medicine: A Comprehensive Study Guide , pp. 227
    • Manning, J.1
  • 16
    • 0021666155 scopus 로고
    • The absence of the descending limb of the Frank-Starling curve of the depressed guinea pig whole ventricle
    • Tucci PJ, Maciel RE, Ribeiro MC. The absence of the descending limb of the Frank-Starling curve of the depressed guinea pig whole ventricle. Braz J Med Biol Res 1984;17:129-33
    • (1984) Braz J Med Biol Res , vol.17 , pp. 129-133
    • Tucci, P.J.1    Maciel, R.E.2    Ribeiro, M.C.3
  • 17
    • 0013840108 scopus 로고
    • The descending limb of the starling curve and the failing heart
    • Katz AM. The descending limb of the starling curve and the failing heart. Circulation 1965;32:871-5
    • (1965) Circulation , vol.32 , pp. 871-875
    • Katz, A.M.1
  • 18
    • 80053322000 scopus 로고    scopus 로고
    • Assessing the diagnostic accuracy of pulse pressure variations for the prediction of fluid responsiveness: A "gray zone" approach
    • Cannesson M, Le Manach Y, Hofer CK, Goarin JP, Lehot JJ, Vallet B, Tavernier B. Assessing the diagnostic accuracy of pulse pressure variations for the prediction of fluid responsiveness: a "gray zone" approach. Anesthesiology 2011;115:231-41
    • (2011) Anesthesiology , vol.115 , pp. 231-241
    • Cannesson, M.1    Le Manach, Y.2    Hofer, C.K.3    Goarin, J.P.4    Lehot, J.J.5    Vallet, B.6    Tavernier, B.7
  • 20
    • 77952582244 scopus 로고    scopus 로고
    • Arterial pressure variation and goal-directed fluid therapy
    • Cannesson M. Arterial pressure variation and goal-directed fluid therapy. J Cardiothorac Vasc Anesth 2010;24:487-97
    • (2010) J Cardiothorac Vasc Anesth , vol.24 , pp. 487-497
    • Cannesson, M.1
  • 21
    • 84055188824 scopus 로고    scopus 로고
    • Randomized controlled trial of intraoperative goal-directed fluid therapy in aerobically fit and unfit patients having major colorectal surgery
    • Challand C, Struthers R, Sneyd JR, Erasmus PD, Mellor N, Hosie KB, Minto G. Randomized controlled trial of intraoperative goal-directed fluid therapy in aerobically fit and unfit patients having major colorectal surgery. Br J Anaesth 2012;108:53-62
    • (2012) Br J Anaesth , vol.108 , pp. 53-62
    • Challand, C.1    Struthers, R.2    Sneyd, J.R.3    Erasmus, P.D.4    Mellor, N.5    Hosie, K.B.6    Minto, G.7
  • 22
    • 0019728656 scopus 로고
    • A microcomputer-based fluid infusion system for the resuscitation of burn patients
    • Bowman RJ, Westenskow DR. A microcomputer-based fluid infusion system for the resuscitation of burn patients. IEEE Trans Biomed Eng 1981;28:475-9
    • (1981) IEEE Trans Biomed Eng , vol.28 , pp. 475-479
    • Bowman, R.J.1    Westenskow, D.R.2
  • 23
    • 0025433789 scopus 로고
    • Clinical application of closed-loop postoperative autotransfusion
    • Blankenship HB, Wallace FD, Pacifico AD. Clinical application of closed-loop postoperative autotransfusion. Med Prog Technol 1990;16:89-93
    • (1990) Med Prog Technol , vol.16 , pp. 89-93
    • Blankenship, H.B.1    Wallace, F.D.2    Pacifico, A.D.3
  • 26
    • 0028364854 scopus 로고
    • Use of a mean systemic filling pressure analogue during the closed-loop control of fluid replacement in continuous hemodiafiltration
    • Parkin G, Wright C, Bellomo R, Boyce N. Use of a mean systemic filling pressure analogue during the closed-loop control of fluid replacement in continuous hemodiafiltration. J Crit Care 1994;9:124-33
    • (1994) J Crit Care , vol.9 , pp. 124-133
    • Parkin, G.1    Wright, C.2    Bellomo, R.3    Boyce, N.4
  • 27
    • 84865588800 scopus 로고    scopus 로고
    • Feedback control is engineering, let's treat it as such
    • author reply 679-81
    • Looke TD. Feedback control is engineering, let's treat it as such. Anesthesiology 2012;117:678-9; author reply 679-81
    • (2012) Anesthesiology , vol.117 , pp. 678-679
    • Looke, T.D.1
  • 28
    • 78650825968 scopus 로고    scopus 로고
    • Robust closed-loop control of propofol administration using WAVCNS index as the controlled variable
    • Hahn JO, Dumont GA, Ansermino J. Robust closed-loop control of propofol administration using WAVCNS index as the controlled variable. Conf Proc IEEE Eng Med Biol Soc 2010;2010:6038-41
    • (2010) Conf Proc IEEE Eng Med Biol Soc , vol.2010 , pp. 6038-6041
    • Hahn, J.O.1    Dumont, G.A.2    Ansermino, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.