메뉴 건너뛰기




Volumn 24, Issue 11, 2013, Pages 1246-1252

Clinical impact, safety, and efficacy of single- versus Dual-Coil ICD leads in MADIT-CRT

Author keywords

atrial arrhythmias; heart failure; implantable cardioverter defibrillators; MADIT CRT mortality

Indexed keywords

ADULT; ARTERY PERFORATION; ARTICLE; CARDIAC RESYNCHRONIZATION THERAPY; CARDIOVASCULAR MORTALITY; CLINICAL EFFECTIVENESS; CONTROLLED STUDY; CORONARY SINUS DISSECTION; DEVICE INFECTION; FEMALE; FOLLOW UP; HEART ARREST; HEART ATRIUM ARRHYTHMIA; HEART ATRIUM FIBRILLATION; HEART ATRIUM FLUTTER; HEART TAMPONADE; HEART VENTRICLE ARRHYTHMIA; HEART VENTRICLE FIBRILLATION; HEART VENTRICLE TACHYCARDIA; HEMATOMA; HEMATOTHORAX; HUMAN; IMPLANTABLE CARDIOVERTER DEFIBRILLATOR; IMPLANTATION; ISCHEMIC CARDIOMYOPATHY; MAJOR CLINICAL STUDY; MALE; MEDICAL DEVICE COMPLICATION; NONISCHEMIC CARDIOMYOPATHY; OUTCOME ASSESSMENT; PATIENT SAFETY; PNEUMOTHORAX; PRIORITY JOURNAL; RESPIRATORY ARREST; RISK FACTOR; SUPRAVENTRICULAR TACHYCARDIA; VEIN DISEASE;

EID: 84886773622     PISSN: 10453873     EISSN: 15408167     Source Type: Journal    
DOI: 10.1111/jce.12219     Document Type: Article
Times cited : (34)

References (19)
  • 1
    • 0028197691 scopus 로고
    • Prospective, randomized comparison in humans of a unipolar defibrillation system with that using an additional superior vena cava electrode
    • Bardy GH, Dolack GL, Kudenchuk PJ, Poole JE, Mehra R, Johnson G,: Prospective, randomized comparison in humans of a unipolar defibrillation system with that using an additional superior vena cava electrode. Circulation 1994; 89: 1090-1093.
    • (1994) Circulation , vol.89 , pp. 1090-1093
    • Bardy, G.H.1    Dolack, G.L.2    Kudenchuk, P.J.3    Poole, J.E.4    Mehra, R.5    Johnson, G.6
  • 2
    • 0028357569 scopus 로고
    • Efficacy of a single-lead unipolar transvenous defibrillator compared with a system employing an additional coronary sinus electrode. A prospective, randomized study
    • Kudenchuk PJ, Bardy GH, Dolack GL, Poole JE, Mehra R, Johnson G,: Efficacy of a single-lead unipolar transvenous defibrillator compared with a system employing an additional coronary sinus electrode. A prospective, randomized study. Circulation 1994; 89: 2641-2644.
    • (1994) Circulation , vol.89 , pp. 2641-2644
    • Kudenchuk, P.J.1    Bardy, G.H.2    Dolack, G.L.3    Poole, J.E.4    Mehra, R.5    Johnson, G.6
  • 3
    • 0030717468 scopus 로고    scopus 로고
    • Lead system optimization for transvenous defibrillation
    • Gold MR, Foster AH, Shorofsky SR,: Lead system optimization for transvenous defibrillation. Am J Cardiol 1997; 80: 1163-1167.
    • (1997) Am J Cardiol , vol.80 , pp. 1163-1167
    • Gold, M.R.1    Foster, A.H.2    Shorofsky, S.R.3
  • 6
    • 0034944467 scopus 로고    scopus 로고
    • Dual-coil vs single-coil active pectoral implantable defibrillator lead systems: Defibrillation energy requirements and probability of defibrillation success at multiples of the defibrillation energy requirements
    • Schulte B, Sperzel J, Carlsson J, Schwarz T, Ehrlich W, Pitschner HF, Neuzner J,: Dual-coil vs single-coil active pectoral implantable defibrillator lead systems: Defibrillation energy requirements and probability of defibrillation success at multiples of the defibrillation energy requirements. Europace 2001; 3: 177-180.
    • (2001) Europace , vol.3 , pp. 177-180
    • Schulte, B.1    Sperzel, J.2    Carlsson, J.3    Schwarz, T.4    Ehrlich, W.5    Pitschner, H.F.6    Neuzner, J.7
  • 7
    • 0042701466 scopus 로고    scopus 로고
    • A randomized prospective study of single coil versus dual coil defibrillation in patients with ventricular arrhythmias undergoing implantable cardioverter defibrillator therapy
    • Rinaldi CA, Simon RD, Geelen P, Reek S, Baszko A, Kuehl M, Gill JS,: A randomized prospective study of single coil versus dual coil defibrillation in patients with ventricular arrhythmias undergoing implantable cardioverter defibrillator therapy. Pacing Clin Electrophysiol 2003; 26: 1684-1690.
    • (2003) Pacing Clin Electrophysiol , vol.26 , pp. 1684-1690
    • Rinaldi, C.A.1    Simon, R.D.2    Geelen, P.3    Reek, S.4    Baszko, A.5    Kuehl, M.6    Gill, J.S.7
  • 9
    • 84886797798 scopus 로고    scopus 로고
    • Single-coil versus dual-coil ICD lead shock efficacy in a large ICD registry
    • Ellis CR HJT,: Single-coil versus dual-coil ICD lead shock efficacy in a large ICD registry. J Innovat Cardiac Rhythm Manag 2012; 3: 953-958.
    • (2012) J Innovat Cardiac Rhythm Manag , vol.3 , pp. 953-958
    • Ellis, C.R.H.1
  • 10
    • 84876688746 scopus 로고    scopus 로고
    • Impact of defibrillation testing on predicted ICD shock efficacy: Implications for clinical practice
    • Smits K, Virag N, Swerdlow CD,: Impact of defibrillation testing on predicted ICD shock efficacy: Implications for clinical practice. Heart Rhythm 2013; 10: 709-717.
    • (2013) Heart Rhythm , vol.10 , pp. 709-717
    • Smits, K.1    Virag, N.2    Swerdlow, C.D.3
  • 11
    • 84860835382 scopus 로고    scopus 로고
    • Dual- versus single-coil implantable defibrillator leads: Review of the literature
    • Neuzner J, Carlsson J,: Dual- versus single-coil implantable defibrillator leads: Review of the literature. Clin Res Cardiol 2012; 101: 239-245.
    • (2012) Clin Res Cardiol , vol.101 , pp. 239-245
    • Neuzner, J.1    Carlsson, J.2
  • 15
    • 80051666300 scopus 로고    scopus 로고
    • Defibrillation testing during implantable cardioverter-defibrillator implantation in Italian current practice: The Assessment of Long-term Induction clinical ValuE (ALIVE) project
    • Stefano B, Pietro RR, Maurizio G, Maurizio L, Renato M, Pietro R, Alessandro P, Gianluca B, Monica M, Sergio C, Massimo S,: Defibrillation testing during implantable cardioverter-defibrillator implantation in Italian current practice: The Assessment of Long-term Induction clinical ValuE (ALIVE) project. Am Heart J 2011; 162: 390-397.
    • (2011) Am Heart J , vol.162 , pp. 390-397
    • Stefano, B.1    Pietro, R.R.2    Maurizio, G.3    Maurizio, L.4    Renato, M.5    Pietro, R.6    Alessandro, P.7    Gianluca, B.8    Monica, M.9    Sergio, C.10    Massimo, S.11
  • 16
    • 79955436789 scopus 로고    scopus 로고
    • Defibrillation threshold testing fails to show clinical benefit during long-term follow-up of patients undergoing cardiac resynchronization therapy defibrillator implantation
    • Michowitz Y, Lellouche N, Contractor T, Bourke T, Wiener I, Buch E, Boyle N, Bersohn M, Shivkumar K,: Defibrillation threshold testing fails to show clinical benefit during long-term follow-up of patients undergoing cardiac resynchronization therapy defibrillator implantation. Europace 2011; 13: 683-688.
    • (2011) Europace , vol.13 , pp. 683-688
    • Michowitz, Y.1    Lellouche, N.2    Contractor, T.3    Bourke, T.4    Wiener, I.5    Buch, E.6    Boyle, N.7    Bersohn, M.8    Shivkumar, K.9
  • 17
    • 39649085555 scopus 로고    scopus 로고
    • The top 10 reasons to avoid defibrillation threshold testing during ICD implantation
    • Viskin S, Rosso R,: The top 10 reasons to avoid defibrillation threshold testing during ICD implantation. Heart Rhythm 2008; 5: 391-393.
    • (2008) Heart Rhythm , vol.5 , pp. 391-393
    • Viskin, S.1    Rosso, R.2
  • 19
    • 84860835382 scopus 로고    scopus 로고
    • Dual- versus single-coil implantable defibrillator leads: Review of the literature
    • Neuzner J, Carlsson J,: Dual- versus single-coil implantable defibrillator leads: Review of the literature. Clin Res Cardiol 2012; 101: 239-245.
    • (2012) Clin Res Cardiol , vol.101 , pp. 239-245
    • Neuzner, J.1    Carlsson, J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.