Pulmonary emphysema diagnosis with a preclinical small-animal x-ray dark-field scatter-contrast scanner

Author keywords

[No Author keywords available]

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL MODEL; ANIMAL TISSUE; ANIMAL WELFARE; ARTICLE; COMPUTED TOMOGRAPHY SCANNER; CONTROLLED STUDY; DIAGNOSTIC TEST ACCURACY STUDY; DIAGNOSTIC VALUE; EX VIVO STUDY; FEMALE; GRATING; IMAGE ANALYSIS; LUNG EMPHYSEMA; MICRO-COMPUTED TOMOGRAPHY; MOUSE; NONHUMAN; PRINCIPAL COMPONENT ANALYSIS; PRIORITY JOURNAL; PROBABILITY; RADIATION SCATTERING; SIGNAL DETECTION;

EID: 84886655806     PISSN: 00338419     EISSN: 15271315     Source Type: Journal    
DOI: 10.1148/radiol.13122413     Document Type: Article
Times cited : (108)

References (21)
  • 1
    • 68849111117 scopus 로고    scopus 로고
    • A postmortem analysis of major causes of early death in patients hospitalized with COPD exacerbation
    • Zvezdin B, Milutinov S, Kojicic M, et al. A postmortem analysis of major causes of early death in patients hospitalized with COPD exacerbation. Chest 2009;136(2):376-380.
    • (2009) Chest , vol.136 , Issue.2 , pp. 376-380
    • Zvezdin, B.1    Milutinov, S.2    Kojicic, M.3
  • 3
    • 77953304186 scopus 로고    scopus 로고
    • Diagnostic imaging in COPD
    • Washko GR. Diagnostic imaging in COPD. Semin Respir Crit Care Med 2010;31(3):276-285.
    • (2010) Semin Respir Crit Care Med , vol.31 , Issue.3 , pp. 276-285
    • Washko, G.R.1
  • 5
    • 48449094163 scopus 로고    scopus 로고
    • High-resolution visualization of airspace structures in intact mice via synchrotron phase-contrast X-ray imaging (PCXI)
    • Parsons DW, Morgan K, Donnelley M, et al. High-resolution visualization of airspace structures in intact mice via synchrotron phase-contrast X-ray imaging (PCXI). J Anat 2008;213(2):217-227.
    • (2008) J Anat , vol.213 , Issue.2 , pp. 217-227
    • Parsons, D.W.1    Morgan, K.2    Donnelley, M.3
  • 7
    • 84872672669 scopus 로고    scopus 로고
    • Experimental validation of image contrast correlation between ultra-small-angle X-ray scattering and grating-based dark-field imaging using a laser-driven compact X-ray source
    • Bech M, Schleede S, Potdevin G, et al. Experimental validation of image contrast correlation between ultra-small-angle X-ray scattering and grating-based dark-field imaging using a laser-driven compact X-ray source. Photonics Lasers Med 2012;1(1):47-50.
    • (2012) Photonics Lasers Med , vol.1 , Issue.1 , pp. 47-50
    • Bech, M.1    Schleede, S.2    Potdevin, G.3
  • 9
    • 67049095952 scopus 로고    scopus 로고
    • Fourier X-ray scattering radiography yields bone structural information
    • Wen H, Bennett EE, Hegedus MM, Rapacchi S. Fourier X-ray scattering radiography yields bone structural information. Radiology 2009;251(3):910-918.
    • (2009) Radiology , vol.251 , Issue.3 , pp. 910-918
    • Wen, H.1    Bennett, E.E.2    Hegedus, M.M.3    Rapacchi, S.4
  • 11
    • 77953598629 scopus 로고    scopus 로고
    • Small-angle scattering computed tomography (SAS-CT) using a Talbot-Lau interferometer and a rotating anode x-ray tube: Theory and experiments
    • Chen GH, Bevins N, Zambelli J, Qi Z. Small-angle scattering computed tomography (SAS-CT) using a Talbot-Lau interferometer and a rotating anode x-ray tube: theory and experiments. Opt Express 2010;18(12):12960-12970.
    • (2010) Opt Express , vol.18 , Issue.12 , pp. 12960-12970
    • Chen, G.H.1    Bevins, N.2    Zambelli, J.3    Qi, Z.4
  • 12
    • 84868152432 scopus 로고    scopus 로고
    • Emphysema diagnosis using X-ray dark-field imaging at a laser-driven compact synchrotron light source
    • Schleede S, Meinel FG, Bech M, et al. Emphysema diagnosis using X-ray dark-field imaging at a laser-driven compact synchrotron light source. Proc Natl Acad Sci U S A 2012;109(44):17880-17885.
    • (2012) Proc Natl Acad Sci U S A , vol.109 , Issue.44 , pp. 17880-17885
    • Schleede, S.1    Meinel, F.G.2    Bech, M.3
  • 13
    • 84886660594 scopus 로고    scopus 로고
    • Comparison of contrast-to-noise ratios of transmission and dark-field signal in gratingbased X-ray imaging for healthy murine lung tissue
    • Schwab F, Schleede S, Hahn D, et al. Comparison of contrast-to-noise ratios of transmission and dark-field signal in gratingbased X-ray imaging for healthy murine lung tissue. Z Med Phys 2012.
    • (2012) Z Med Phys
    • Schwab, F.1    Schleede, S.2    Hahn, D.3
  • 14
    • 79952715657 scopus 로고    scopus 로고
    • Activation of the WNT/b-catenin pathway attenuates experimental emphysema
    • Kneidinger N, Yildirim AÖ, Callegari J, et al. Activation of the WNT/b-catenin pathway attenuates experimental emphysema. Am J Respir Crit Care Med 2011;183(6):723-733.
    • (2011) Am J Respir Crit Care Med , vol.183 , Issue.6 , pp. 723-733
    • Kneidinger, N.1    Yildirim, A.Ö.2    Callegari, J.3
  • 15
    • 33645795432 scopus 로고    scopus 로고
    • Phase retrieval and differential phase-contrast imaging with low-brilliance X-ray sources
    • DOI 10.1038/nphys265, PII N265
    • Pfeiffer F, Weitkamp T, Bunk O, David C. Phase retrieval and differential phasecontrast imaging with low-brilliance X-ray sources. Nat Phys 2006;2(4):258-261. (Pubitemid 43553647)
    • (2006) Nature Physics , vol.2 , Issue.4 , pp. 258-261
    • Pfeiffer, F.1    Weitkamp, T.2    Bunk, O.3    David, C.4
  • 16
    • 80855134336 scopus 로고    scopus 로고
    • Development of a prototype gantry system for preclinical x-ray phase-contrast computed tomography
    • Tapfer A, Bech M, Pauwels B, et al. Development of a prototype gantry system for preclinical x-ray phase-contrast computed tomography. Med Phys 2011;38(11):5910-5915.
    • (2011) Med Phys , vol.38 , Issue.11 , pp. 5910-5915
    • Tapfer, A.1    Bech, M.2    Pauwels, B.3
  • 17
    • 84866846530 scopus 로고    scopus 로고
    • Experimental results from a preclinical X-ray phase-contrast CT scanner
    • Tapfer A, Bech M, Velroyen A, et al. Experimental results from a preclinical X-ray phase-contrast CT scanner. Proc Natl Acad Sci U S A 2012;109(39):15691-15696.
    • (2012) Proc Natl Acad Sci U S A , vol.109 , Issue.39 , pp. 15691-15696
    • Tapfer, A.1    Bech, M.2    Velroyen, A.3
  • 18
    • 69949162768 scopus 로고    scopus 로고
    • Quantitative grating-based x-ray dark-field computed tomography
    • Wang ZT, Kang KJ, Huang ZF, et al. Quantitative grating-based x-ray dark-field computed tomography. Appl Phys Lett 2009;95(9):094105-094108.
    • (2009) Appl Phys Lett , vol.95 , Issue.9 , pp. 094105-094108
    • Wang, Z.T.1    Kang, K.J.2    Huang, Z.F.3
  • 19
    • 77955592118 scopus 로고    scopus 로고
    • On the origin of visibility contrast in x-ray Talbot interferometry
    • Yashiro W, Terui Y, Kawabata K, Momose A. On the origin of visibility contrast in x-ray Talbot interferometry. Opt Express 2010;18(16):16890-16901.
    • (2010) Opt Express , vol.18 , Issue.16 , pp. 16890-16901
    • Yashiro, W.1    Terui, Y.2    Kawabata, K.3    Momose, A.4
  • 20
    • 79961077394 scopus 로고    scopus 로고
    • Interpretation of dark-field contrast and particle-size selectivity in grating interferometers
    • Lynch SK, Pai V, Auxier J, et al. Interpretation of dark-field contrast and particle-size selectivity in grating interferometers. Appl Opt 2011;50(22):4310-4319.
    • (2011) Appl Opt , vol.50 , Issue.22 , pp. 4310-4319
    • Lynch, S.K.1    Pai, V.2    Auxier, J.3
  • 21
    • 84865266251 scopus 로고    scopus 로고
    • Quantitative wave-optical numerical analysis of the dark-field signal in grating-based x-ray interferometry
    • Malecki A, Potdevin G, Pfeiffer F. Quantitative wave-optical numerical analysis of the dark-field signal in grating-based x-ray interferometry. Europhys Lett 2012;99(4):48001-48006.
    • (2012) Europhys Lett , vol.99 , Issue.4 , pp. 48001-48006
    • Malecki, A.1    Potdevin, G.2    Pfeiffer, F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.