메뉴 건너뛰기




Volumn 17, Issue 8, 2013, Pages 1929-1935

Clinical study evaluating the discrepancy of two different impression techniques of four implants in an edentulous jaw

Author keywords

Accuracy; CAD CAM; Implants; Impression; Scan bodies

Indexed keywords

DENTAL IMPRESSION; EDENTULOUSNESS; HUMAN; PATHOLOGY; TOOTH PROSTHESIS;

EID: 84886594522     PISSN: 14326981     EISSN: 14363771     Source Type: Journal    
DOI: 10.1007/s00784-012-0885-z     Document Type: Article
Times cited : (31)

References (37)
  • 2
    • 0030279335 scopus 로고    scopus 로고
    • An in vivo quantitative analysis of the fit of Nobel Biocare implant superstructures
    • Cheshire PD, Hobkirk JA (1996) An in vivo quantitative analysis of the fit of Nobel Biocare implant superstructures. J Oral Rehabil 23: 782-789.
    • (1996) J Oral Rehabil , vol.23 , pp. 782-789
    • Cheshire, P.D.1    Hobkirk, J.A.2
  • 3
    • 0035223781 scopus 로고    scopus 로고
    • The significance of passive framework fit in implant prosthodontics: current status
    • Sahin S, Cehreli MC (2001) The significance of passive framework fit in implant prosthodontics: current status. Implant Dent 10: 85-92.
    • (2001) Implant Dent , vol.10 , pp. 85-92
    • Sahin, S.1    Cehreli, M.C.2
  • 4
    • 0028390316 scopus 로고
    • Loose gold screws frequently occur in full-arch fixed prostheses supported by osseointegrated implants after 5 years
    • Kallus T, Bessing C (1994) Loose gold screws frequently occur in full-arch fixed prostheses supported by osseointegrated implants after 5 years. Int J Oral Maxillofac Implants 9: 169-178.
    • (1994) Int J Oral Maxillofac Implants , vol.9 , pp. 169-178
    • Kallus, T.1    Bessing, C.2
  • 5
    • 33749820665 scopus 로고    scopus 로고
    • Impression techniques for implant dentistry
    • Chee W, Jivraj S (2006) Impression techniques for implant dentistry. Br Dent J 201: 429-432.
    • (2006) Br Dent J , vol.201 , pp. 429-432
    • Chee, W.1    Jivraj, S.2
  • 6
    • 11444261183 scopus 로고    scopus 로고
    • Evaluation of transfer impressions for osseointegrated implants at various angulations
    • Assuncao WG, Filho HG, Zaniquelli O (2004) Evaluation of transfer impressions for osseointegrated implants at various angulations. Implant Dent 13: 358-366.
    • (2004) Implant Dent , vol.13 , pp. 358-366
    • Assuncao, W.G.1    Filho, H.G.2    Zaniquelli, O.3
  • 7
    • 0026311384 scopus 로고
    • Comparison of impression techniques for a five-implant mandibular model
    • Carr AB (1991) Comparison of impression techniques for a five-implant mandibular model. Int J Oral Maxillofac Implants 6: 448-455.
    • (1991) Int J Oral Maxillofac Implants , vol.6 , pp. 448-455
    • Carr, A.B.1
  • 9
    • 77953574592 scopus 로고    scopus 로고
    • Effect of implant angulation, connection length, and impression material on the dimensional accuracy of implant impressions: an in vitro comparative study
    • Sorrentino R, Gherlone EF, Calesini G, Zarone F (2010) Effect of implant angulation, connection length, and impression material on the dimensional accuracy of implant impressions: an in vitro comparative study. Clin Implant Dent Relat Res 12(Suppl 1): e63-e76.
    • (2010) Clin Implant Dent Relat Res , vol.12 , Issue.SUPPL. 1
    • Sorrentino, R.1    Gherlone, E.F.2    Calesini, G.3    Zarone, F.4
  • 10
    • 84864282585 scopus 로고    scopus 로고
    • State of Industry
    • State of Industry (2000) Lab Management Today 16: 9-15.
    • (2000) Lab Management Today , vol.16 , pp. 9-15
  • 11
    • 52249091557 scopus 로고    scopus 로고
    • The accuracy of implant impressions: a systematic review
    • Lee H, So JS, Hochstedler JL, Ercoli C (2008) The accuracy of implant impressions: a systematic review. J Prosthet Dent 100: 285-291.
    • (2008) J Prosthet Dent , vol.100 , pp. 285-291
    • Lee, H.1    So, J.S.2    Hochstedler, J.L.3    Ercoli, C.4
  • 12
    • 34248171935 scopus 로고    scopus 로고
    • The dimensional accuracy of four impression techniques with the use of addition silicone impression materials
    • Al-Bakri IA, Hussey D, Al-Omari WM (2007) The dimensional accuracy of four impression techniques with the use of addition silicone impression materials. J Clin Dent 18: 29-33.
    • (2007) J Clin Dent , vol.18 , pp. 29-33
    • Al-Bakri, I.A.1    Hussey, D.2    Al-Omari, W.M.3
  • 13
    • 0025412492 scopus 로고
    • An evaluation of impression techniques for osseointegrated implants
    • Spector MR, Donovan TE, Nicholls JI (1990) An evaluation of impression techniques for osseointegrated implants. J Prosthet Dent 63: 444-447.
    • (1990) J Prosthet Dent , vol.63 , pp. 444-447
    • Spector, M.R.1    Donovan, T.E.2    Nicholls, J.I.3
  • 14
    • 77954862839 scopus 로고    scopus 로고
    • Molecular leakage at implant-abutment connection-in vitro investigation of tightness of internal conical implant-abutment connections against endotoxin penetration
    • Harder S, Dimaczek B, Acil Y, Terheyden H, Freitag-Wolf S, Kern M (2010) Molecular leakage at implant-abutment connection-in vitro investigation of tightness of internal conical implant-abutment connections against endotoxin penetration. Clin Oral Investig 14: 427-432.
    • (2010) Clin Oral Investig , vol.14 , pp. 427-432
    • Harder, S.1    Dimaczek, B.2    Acil, Y.3    Terheyden, H.4    Freitag-Wolf, S.5    Kern, M.6
  • 15
    • 55649083146 scopus 로고    scopus 로고
    • Implant-abutment interface design affects fatigue and fracture strength of implants
    • Steinebrunner L, Wolfart S, Ludwig K, Kern M (2008) Implant-abutment interface design affects fatigue and fracture strength of implants. Clin Oral Implants Res 19: 1276-1284.
    • (2008) Clin Oral Implants Res , vol.19 , pp. 1276-1284
    • Steinebrunner, L.1    Wolfart, S.2    Ludwig, K.3    Kern, M.4
  • 17
    • 77951891112 scopus 로고    scopus 로고
    • Effects of repeated manual disassembly and reassembly on the positional stability of various implant-abutment complexes: an experimental study
    • Semper W, Heberer S, Mehrhof J, Schink T, Nelson K (2010) Effects of repeated manual disassembly and reassembly on the positional stability of various implant-abutment complexes: an experimental study. Int J Oral Maxillofac Implants 25: 86-94.
    • (2010) Int J Oral Maxillofac Implants , vol.25 , pp. 86-94
    • Semper, W.1    Heberer, S.2    Mehrhof, J.3    Schink, T.4    Nelson, K.5
  • 18
    • 7444265288 scopus 로고    scopus 로고
    • An evaluation of impression techniques for multiple internal connection implant prostheses
    • Vigolo P, Fonzi F, Majzoub Z, Cordioli G (2004) An evaluation of impression techniques for multiple internal connection implant prostheses. J Prosthet Dent 92: 470-476.
    • (2004) J Prosthet Dent , vol.92 , pp. 470-476
    • Vigolo, P.1    Fonzi, F.2    Majzoub, Z.3    Cordioli, G.4
  • 19
  • 20
    • 34250364800 scopus 로고    scopus 로고
    • Comparative analysis of 4 impression techniques for implants
    • Cabral LM, Guedes CG (2007) Comparative analysis of 4 impression techniques for implants. Implant Dent 16: 187-194.
    • (2007) Implant Dent , vol.16 , pp. 187-194
    • Cabral, L.M.1    Guedes, C.G.2
  • 21
    • 84864283529 scopus 로고    scopus 로고
    • Evaluation of impression accuracy for a four-implant mandibular model-a digital approach
    • Stimmelmayr M, Erdelt K, Guth JF, Happe A, Beuer F (2012) Evaluation of impression accuracy for a four-implant mandibular model-a digital approach. Clin Oral Investig 16: 1137-1142.
    • (2012) Clin Oral Investig , vol.16 , pp. 1137-1142
    • Stimmelmayr, M.1    Erdelt, K.2    Guth, J.F.3    Happe, A.4    Beuer, F.5
  • 22
    • 84861784308 scopus 로고    scopus 로고
    • Digital evaluation of the reproducibility of implant scanbody fit-an in vitro study
    • Stimmelmayr M, Guth JF, Erdelt K, Edelhoff D, Beuer F (2012) Digital evaluation of the reproducibility of implant scanbody fit-an in vitro study. Clin Oral Investig 16: 851-856.
    • (2012) Clin Oral Investig , vol.16 , pp. 851-856
    • Stimmelmayr, M.1    Guth, J.F.2    Erdelt, K.3    Edelhoff, D.4    Beuer, F.5
  • 23
    • 79952202479 scopus 로고    scopus 로고
    • Comparison of the three-dimensional correctness of impression techniques: a randomized controlled trial
    • Luthardt RG, Walter MH, Quaas S, Koch R, Rudolph H (2010) Comparison of the three-dimensional correctness of impression techniques: a randomized controlled trial. Quintessence Int 41: 845-853.
    • (2010) Quintessence Int , vol.41 , pp. 845-853
    • Luthardt, R.G.1    Walter, M.H.2    Quaas, S.3    Koch, R.4    Rudolph, H.5
  • 25
    • 0027620268 scopus 로고
    • The accuracy of six impression techniques for osseointegrated implants
    • Barrett MG, de Rijk WG, Burgess JO (1993) The accuracy of six impression techniques for osseointegrated implants. J Prosthodont 2: 75-82.
    • (1993) J Prosthodont , vol.2 , pp. 75-82
    • Barrett, M.G.1    de Rijk, W.G.2    Burgess, J.O.3
  • 27
    • 0034185646 scopus 로고    scopus 로고
    • Evaluation of impression accuracy for osseointegrated implant supported superstructures
    • Herbst D, Nel JC, Driessen CH, Becker PJ (2000) Evaluation of impression accuracy for osseointegrated implant supported superstructures. J Prosthet Dent 83: 555-561.
    • (2000) J Prosthet Dent , vol.83 , pp. 555-561
    • Herbst, D.1    Nel, J.C.2    Driessen, C.H.3    Becker, P.J.4
  • 28
    • 0025622921 scopus 로고
    • The accuracy of implant master casts constructed from transfer impressions
    • Humphries RM, Yaman P, Bloem TJ (1990) The accuracy of implant master casts constructed from transfer impressions. Int J Oral Maxillofac Implants 5: 331-336.
    • (1990) Int J Oral Maxillofac Implants , vol.5 , pp. 331-336
    • Humphries, R.M.1    Yaman, P.2    Bloem, T.J.3
  • 30
    • 0027031321 scopus 로고
    • Comparison of impression techniques for a two-implant 15-degree divergent model
    • Carr AB (1992) Comparison of impression techniques for a two-implant 15-degree divergent model. Int J Oral Maxillofac Implants 7: 468-475.
    • (1992) Int J Oral Maxillofac Implants , vol.7 , pp. 468-475
    • Carr, A.B.1
  • 31
    • 34347329149 scopus 로고    scopus 로고
    • Accuracy of two impression techniques with angulated implants
    • Conrad HJ, Pesun IJ, DeLong R, Hodges JS (2007) Accuracy of two impression techniques with angulated implants. J Prosthet Dent 97: 349-356.
    • (2007) J Prosthet Dent , vol.97 , pp. 349-356
    • Conrad, H.J.1    Pesun, I.J.2    DeLong, R.3    Hodges, J.S.4
  • 32
    • 2142820784 scopus 로고    scopus 로고
    • An evaluation of three implant level impression techniques for single tooth implant
    • Daoudi MF, Setchell DJ, Searson LJ (2004) An evaluation of three implant level impression techniques for single tooth implant. Eur J Prosthodont Restor Dent 12: 9-14.
    • (2004) Eur J Prosthodont Restor Dent , vol.12 , pp. 9-14
    • Daoudi, M.F.1    Setchell, D.J.2    Searson, L.J.3
  • 33
    • 0036728374 scopus 로고    scopus 로고
    • Verification jig for implant-supported prostheses: a comparison of standard impressions with verification jigs made of different materials
    • De La Cruz JE, Funkenbusch PD, Ercoli C, Moss ME, Graser GN, Tallents RH (2002) Verification jig for implant-supported prostheses: a comparison of standard impressions with verification jigs made of different materials. J Prosthet Dent 88: 329-336.
    • (2002) J Prosthet Dent , vol.88 , pp. 329-336
    • De La Cruz, J.E.1    Funkenbusch, P.D.2    Ercoli, C.3    Moss, M.E.4    Graser, G.N.5    Tallents, R.H.6
  • 34
    • 40849137885 scopus 로고    scopus 로고
    • Accuracy of impressions and casts using different implant impression techniques in a multi-implant system with an internal hex connection
    • Wenz HJ, Hertrampf K (2008) Accuracy of impressions and casts using different implant impression techniques in a multi-implant system with an internal hex connection. Int J Oral Maxillofac Implants 23: 39-47.
    • (2008) Int J Oral Maxillofac Implants , vol.23 , pp. 39-47
    • Wenz, H.J.1    Hertrampf, K.2
  • 35
    • 78049428867 scopus 로고    scopus 로고
    • Impact of abutment rotation and angulation on marginal fit: theoretical considerations
    • Semper W, Kraft S, Mehrhof J, Nelson K (2010) Impact of abutment rotation and angulation on marginal fit: theoretical considerations. Int J Oral Maxillofac Implants 25: 752-758.
    • (2010) Int J Oral Maxillofac Implants , vol.25 , pp. 752-758
    • Semper, W.1    Kraft, S.2    Mehrhof, J.3    Nelson, K.4
  • 36
    • 68949125270 scopus 로고    scopus 로고
    • Optical three-dimensional scanning acquisition of the position of osseointegrated implants: an in vitro study to determine method accuracy and operational feasibility
    • Del Corso M, Aba G, Vazquez L, Dargaud J, Dohan Ehrenfest DM (2009) Optical three-dimensional scanning acquisition of the position of osseointegrated implants: an in vitro study to determine method accuracy and operational feasibility. Clin Implant Dent Relat Res 11: 214-221.
    • (2009) Clin Implant Dent Relat Res , vol.11 , pp. 214-221
    • Del Corso, M.1    Aba, G.2    Vazquez, L.3    Dargaud, J.4    Dohan Ehrenfest, D.M.5