메뉴 건너뛰기




Volumn 168, Issue 4, 2013, Pages 4209-4213

Diagnostic accuracy of optical coherence tomography parameters in predicting in-stent hemodynamic severe coronary lesions: Validation against fractional flow reserve

Author keywords

Fractional flow reserve; In stent restenosis; Optical coherence tomography

Indexed keywords

AGED; ARTICLE; CARDIOVASCULAR PARAMETERS; CONTROLLED STUDY; CORONARY ARTERY DISEASE; DIAGNOSTIC ACCURACY; DIAGNOSTIC IMAGING; DIAGNOSTIC TEST ACCURACY STUDY; DIAGNOSTIC VALUE; DISEASE SEVERITY; FEMALE; FRACTIONAL FLOW RESERVE; HEART HEMODYNAMICS; HUMAN; IN-STENT RESTENOSIS; INTERMETHOD COMPARISON; MAJOR CLINICAL STUDY; MALE; MAXIMUM NEOINTIMAL AREA; MAXIMUM NEOINTIMAL AREA STENOSIS; MINIMAL LUMINAL AREA; MINIMAL LUMINAL DIAMETER; OPTICAL COHERENCE TOMOGRAPHY; PREDICTION; PREDICTIVE VALUE; PRIORITY JOURNAL; SENSITIVITY AND SPECIFICITY;

EID: 84886382063     PISSN: 01675273     EISSN: 18741754     Source Type: Journal    
DOI: 10.1016/j.ijcard.2013.07.178     Document Type: Article
Times cited : (16)

References (19)
  • 1
    • 77955066802 scopus 로고    scopus 로고
    • Fractional flow reserve versus angiography for guiding percutaneous coronary intervention in patients with multivessel coronary artery disease: 2-year follow-up of the FAME (Fractional Flow Reserve Versus Angiography for Multivessel Evaluation) study
    • N.H. Pijls, W.F. Fearon, and P.A. Tonino Fractional flow reserve versus angiography for guiding percutaneous coronary intervention in patients with multivessel coronary artery disease: 2-year follow-up of the FAME (Fractional Flow Reserve Versus Angiography for Multivessel Evaluation) study J Am Coll Cardiol 56 3 2010 177 184
    • (2010) J Am Coll Cardiol , vol.56 , Issue.3 , pp. 177-184
    • Pijls, N.H.1    Fearon, W.F.2    Tonino, P.A.3
  • 2
    • 58349112528 scopus 로고    scopus 로고
    • Fractional flow reserve versus angiography for guiding percutaneous coronary intervention
    • P.A. Tonino, B. De Bruyne, and N.H. Pijls Fractional flow reserve versus angiography for guiding percutaneous coronary intervention N Engl J Med 360 3 2009 213 224
    • (2009) N Engl J Med , vol.360 , Issue.3 , pp. 213-224
    • Tonino, P.A.1    De Bruyne, B.2    Pijls, N.H.3
  • 3
    • 84866087823 scopus 로고    scopus 로고
    • Fractional flow reserve-guided PCI versus medical therapy in stable coronary disease
    • B. De Bruyne, N.H. Pijls, and B. Kalesan Fractional flow reserve-guided PCI versus medical therapy in stable coronary disease N Engl J Med 367 11 2012 991 1001
    • (2012) N Engl J Med , vol.367 , Issue.11 , pp. 991-1001
    • De Bruyne, B.1    Pijls, N.H.2    Kalesan, B.3
  • 4
    • 0033587638 scopus 로고    scopus 로고
    • Clinical potential of intravascular ultrasound for physiological assessment of coronary stenosis: Relationship between quantitative ultrasound tomography and pressure-derived fractional flow reserve
    • A. Takagi, Y. Tsurumi, Y. Ishii, K. Suzuki, M. Kawana, and H. Kasanuki Clinical potential of intravascular ultrasound for physiological assessment of coronary stenosis: relationship between quantitative ultrasound tomography and pressure-derived fractional flow reserve Circulation 100 3 1999 250 255
    • (1999) Circulation , vol.100 , Issue.3 , pp. 250-255
    • Takagi, A.1    Tsurumi, Y.2    Ishii, Y.3    Suzuki, K.4    Kawana, M.5    Kasanuki, H.6
  • 5
    • 0031870569 scopus 로고    scopus 로고
    • Clinical, intravascular ultrasound, and quantitative angiographic determinants of the coronary flow reserve before and after percutaneous transluminal coronary angioplasty
    • A. Abizaid, G.S. Mintz, and A.D. Pichard Clinical, intravascular ultrasound, and quantitative angiographic determinants of the coronary flow reserve before and after percutaneous transluminal coronary angioplasty Am J Cardiol 82 4 1998 423 428
    • (1998) Am J Cardiol , vol.82 , Issue.4 , pp. 423-428
    • Abizaid, A.1    Mintz, G.S.2    Pichard, A.D.3
  • 6
    • 84858213836 scopus 로고    scopus 로고
    • Morphometric assessment of coronary stenosis relevance with optical coherence tomography: A comparison with fractional flow reserve and intravascular ultrasound
    • N. Gonzalo, J. Escaned, and F. Alfonso Morphometric assessment of coronary stenosis relevance with optical coherence tomography: a comparison with fractional flow reserve and intravascular ultrasound J Am Coll Cardiol 59 12 2012 1080 1089
    • (2012) J Am Coll Cardiol , vol.59 , Issue.12 , pp. 1080-1089
    • Gonzalo, N.1    Escaned, J.2    Alfonso, F.3
  • 7
    • 77953662333 scopus 로고    scopus 로고
    • Reproducibility of quantitative optical coherence tomography for stent analysis
    • N. Gonzalo, H.M. Garcia-Garcia, and P.W. Serruys Reproducibility of quantitative optical coherence tomography for stent analysis EuroIntervention 5 2 2009 224 232
    • (2009) EuroIntervention , vol.5 , Issue.2 , pp. 224-232
    • Gonzalo, N.1    Garcia-Garcia, H.M.2    Serruys, P.W.3
  • 8
    • 84863229443 scopus 로고    scopus 로고
    • Consensus standards for acquisition, measurement, and reporting of intravascular optical coherence tomography studies: A report from the International Working Group for Intravascular Optical Coherence Tomography Standardization and Validation
    • G.J. Tearney, E. Regar, and T. Akasaka Consensus standards for acquisition, measurement, and reporting of intravascular optical coherence tomography studies: a report from the International Working Group for Intravascular Optical Coherence Tomography Standardization and Validation J Am Coll Cardiol 59 12 2012 1058 1072
    • (2012) J Am Coll Cardiol , vol.59 , Issue.12 , pp. 1058-1072
    • Tearney, G.J.1    Regar, E.2    Akasaka, T.3
  • 9
    • 41949118345 scopus 로고    scopus 로고
    • In vivo comparison between optical coherence tomography and intravascular ultrasound for detecting small degrees of in-stent neointima after stent implantation
    • Y. Suzuki, F. Ikeno, and T. Koizumi In vivo comparison between optical coherence tomography and intravascular ultrasound for detecting small degrees of in-stent neointima after stent implantation JACC Cardiovasc Interv 1 2 2008 168 173
    • (2008) JACC Cardiovasc Interv , vol.1 , Issue.2 , pp. 168-173
    • Suzuki, Y.1    Ikeno, F.2    Koizumi, T.3
  • 10
    • 84862171761 scopus 로고    scopus 로고
    • First Results of the DEB-AMI (Drug Eluting Balloon in Acute ST-Segment Elevation Myocardial Infarction) Trial: A multicenter randomized comparison of drug-eluting balloon plus bare-metal stent versus bare-metal stent versus drug-eluting stent in primary percutaneous coronary intervention with 6-month angiographic, intravascular, functional, and clinical outcomes
    • A. Belkacemi, P. Agostoni, and H.M. Nathoe First Results of the DEB-AMI (Drug Eluting Balloon in Acute ST-Segment Elevation Myocardial Infarction) Trial: a multicenter randomized comparison of drug-eluting balloon plus bare-metal stent versus bare-metal stent versus drug-eluting stent in primary percutaneous coronary intervention with 6-month angiographic, intravascular, functional, and clinical outcomes J Am Coll Cardiol 19 59(25) 2012 2327 2337
    • (2012) J Am Coll Cardiol , vol.19 , Issue.25 , pp. 2327-2337
    • Belkacemi, A.1    Agostoni, P.2    Nathoe, H.M.3
  • 11
    • 84879335999 scopus 로고    scopus 로고
    • Serial morphological and functional assessment of drug-eluting balloon for in-stent restenotic lesions: Mechanisms of action evaluated with angiography, optical coherence tomography and fractional flow reserve
    • P. Agostoni, A. Belkacemi, M. Voskuil, N. Nathoe, P.A. Doevendans, and P. Stella Serial morphological and functional assessment of drug-eluting balloon for in-stent restenotic lesions: mechanisms of action evaluated with angiography, optical coherence tomography and fractional flow reserve J Am Coll Cardiol Card Vasc Interv 6 6 2013 569 576
    • (2013) J Am Coll Cardiol Card Vasc Interv , vol.6 , Issue.6 , pp. 569-576
    • Agostoni, P.1    Belkacemi, A.2    Voskuil, M.3    Nathoe, N.4    Doevendans, P.A.5    Stella, P.6
  • 12
    • 71149110474 scopus 로고    scopus 로고
    • Quantitative coronary angiography in the current era: Principles and applications
    • P. Garrone, G. Biondi-Zoccai, and I. Salvetti Quantitative coronary angiography in the current era: principles and applications J Interv Cardiol 22 6 2009 527 536
    • (2009) J Interv Cardiol , vol.22 , Issue.6 , pp. 527-536
    • Garrone, P.1    Biondi-Zoccai, G.2    Salvetti, I.3
  • 13
    • 84870924327 scopus 로고    scopus 로고
    • A multicenter randomized comparison of drug-eluting balloon plus bare-metal stent versus bare-metal stent versus drug-eluting stent in bifurcation lesions treated with a single-stenting technique: Six-month angiographic and 12-month clinical results of the drug-eluting balloon in bifurcations trial
    • P.R. Stella, A. Belkacemi, and C. Dubois A multicenter randomized comparison of drug-eluting balloon plus bare-metal stent versus bare-metal stent versus drug-eluting stent in bifurcation lesions treated with a single-stenting technique: Six-month angiographic and 12-month clinical results of the drug-eluting balloon in bifurcations trial Catheter Cardiovasc Interv 80 7 2012 1138 1146
    • (2012) Catheter Cardiovasc Interv , vol.80 , Issue.7 , pp. 1138-1146
    • Stella, P.R.1    Belkacemi, A.2    Dubois, C.3
  • 14
    • 44149100010 scopus 로고    scopus 로고
    • From bench to bedside: A novel technique of acquiring OCT images
    • F. Prati, M. Cera, and V. Ramazzotti From bench to bedside: a novel technique of acquiring OCT images Circ J 72 5 2008 839 843
    • (2008) Circ J , vol.72 , Issue.5 , pp. 839-843
    • Prati, F.1    Cera, M.2    Ramazzotti, V.3
  • 15
    • 84861099764 scopus 로고    scopus 로고
    • Optical coherence tomography assessment of early stent strut coverage in patients treated with a thin-strut bare cobalt-chromium stent coated with silicon carbide
    • M. Samim, P. Agostoni, M. Voskuil, A. Belkacemi, P.A. Doevendans, and P.R. Stella Optical coherence tomography assessment of early stent strut coverage in patients treated with a thin-strut bare cobalt-chromium stent coated with silicon carbide Int J Cardiol 157 2 2012 291 292
    • (2012) Int J Cardiol , vol.157 , Issue.2 , pp. 291-292
    • Samim, M.1    Agostoni, P.2    Voskuil, M.3    Belkacemi, A.4    Doevendans, P.A.5    Stella, P.R.6
  • 16
    • 72049127763 scopus 로고    scopus 로고
    • Optical coherence tomography: New (near-infrared) light on stent implantation?
    • P. Agostoni, and P.R. Stella Optical coherence tomography: new (near-infrared) light on stent implantation? Heart 95 23 2009 1895 1896
    • (2009) Heart , vol.95 , Issue.23 , pp. 1895-1896
    • Agostoni, P.1    Stella, P.R.2
  • 17
    • 79961190644 scopus 로고    scopus 로고
    • Assessment of coronary stent by optical coherence tomography, methodology and definitions
    • E.A. Mehanna, G.F. Attizzani, H. Kyono, M. Hake, and H.G. Bezerra Assessment of coronary stent by optical coherence tomography, methodology and definitions Int J Cardiovasc Imaging 27 2 2010 259 269
    • (2010) Int J Cardiovasc Imaging , vol.27 , Issue.2 , pp. 259-269
    • Mehanna, E.A.1    Attizzani, G.F.2    Kyono, H.3    Hake, M.4    Bezerra, H.G.5
  • 18
    • 77951666959 scopus 로고    scopus 로고
    • New set of intravascular ultrasound-derived anatomic criteria for defining functionally significant stenoses in small coronary arteries (results from Intravascular Ultrasound Diagnostic Evaluation of Atherosclerosis in Singapore [IDEAS] study)
    • C.H. Lee, B.C. Tai, and C.Y. Soon New set of intravascular ultrasound-derived anatomic criteria for defining functionally significant stenoses in small coronary arteries (results from Intravascular Ultrasound Diagnostic Evaluation of Atherosclerosis in Singapore [IDEAS] study) Am J Cardiol 105 10 2010 1378 1384
    • (2010) Am J Cardiol , vol.105 , Issue.10 , pp. 1378-1384
    • Lee, C.H.1    Tai, B.C.2    Soon, C.Y.3
  • 19
    • 79961190486 scopus 로고    scopus 로고
    • Utilization of frequency domain optical coherence tomography and fractional flow reserve to assess intermediate coronary artery stenoses: Conciliating anatomic and physiologic information
    • G.T. Stefano, H.G. Bezerra, and G. Attizzani Utilization of frequency domain optical coherence tomography and fractional flow reserve to assess intermediate coronary artery stenoses: conciliating anatomic and physiologic information Int J Cardiovasc Imaging 27 2 2011 299 308
    • (2011) Int J Cardiovasc Imaging , vol.27 , Issue.2 , pp. 299-308
    • Stefano, G.T.1    Bezerra, H.G.2    Attizzani, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.