Consensus standards for acquisition, measurement, and reporting of intravascular optical coherence tomography studies: A report from the International Working Group for Intravascular Optical Coherence Tomography Standardization and Validation
(73)
Tearney, Guillermo J
a
Regar, Evelyn
b
Akasaka, Takashi
c
Adriaenssens, Tom
d
Barlis, Peter
d
Bezerra, Hiram G
d
Bouma, Brett
d
Bruining, Nico
d
Cho, Jin Man
d
Chowdhary, Saqib
d
Costa, Marco A
d
De Silva, Ranil
d
Dijkstra, Jouke
d
Di Mario, Carlo
d
Dudeck, Darius
d
Falk, Erlin
d
Feldman, Marc D
d
Fitzgerald, Peter
d
Garcia, Hector
d
Gonzalo, Nieves
d
Granada, Juan F
d
Guagliumi, Giulio
d
Holm, Niels R
d
Honda, Yasuhiro
d
Ikeno, Fumiaki
d
Kawasaki, Masanori
d
Kochman, Janusz
d
Koltowski, Lukasz
d
Kubo, Takashi
d
Kume, Teruyoshi
d
Kyono, Hiroyuki
d
Lam, Cheung Chi Simon
d
Lamouche, Guy
d
Lee, David P
d
Leon, Martin B
d
Maehara, Akiko
d
Manfrini, Olivia
d
Mintz, Gary S
d
Mizuno, Kyiouchi
d
Morel, Marie Angle
d
Nadkarni, Seemantini
d
Okura, Hiroyuki
d
Otake, Hiromasa
d
Pietrasik, Arkadiusz
d
Prati, Francesco
d
Rber, Lorenz
d
Radu, Maria D
d
Rieber, Johannes
d
Riga, Maria
d
Rollins, Andrew
d
Rosenberg, Mireille
d
Sirbu, Vasile
d
Serruys, Patrick W J C
d
Shimada, Kenei
d
Shinke, Toshiro
d
Shite, Junya
d
Siegel, Eliot
d
Sonada, Shinjo
d
Suter, Melissa
d
Takarada, Shigeho
d
Tanaka, Atsushi
d
Terashima, Mitsuyasu
d
Troels, Thim
d
Uemura, Shiro
d
Ughi, Giovanni J
d
Van Beusekom, Heleen M M
d
Van Der Steen, Antonius F W
d
Van Es, Gerrit Ann
d
Van Soest, Gijs
d
Virmani, Renu
d
Waxman, Sergio
d
Weissman, Neil J
d
Weisz, Giora
d
more..
d
NONE
|
-
1
-
-
0035312809
-
American College of Cardiology Clinical Expert Consensus Document on Standards for Acquisition, Measurement and Reporting of Intravascular Ultrasound Studies (IVUS) A report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents
-
G.S. Mintz, S.E. Nissen, W.D. Anderson American College of Cardiology Clinical Expert Consensus Document on Standards for Acquisition, Measurement and Reporting of Intravascular Ultrasound Studies (IVUS) A report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents J Am Coll Cardiol 37 2001 1478 1492
-
(2001)
J Am Coll Cardiol
, vol.37
, pp. 1478-1492
-
-
Mintz, G.S.1
Nissen, S.E.2
Anderson, W.D.3
-
2
-
-
0034019601
-
Lessons from sudden coronary death: A comprehensive morphological classification scheme for atherosclerotic lesions
-
R. Virmani, F.D. Kolodgie, A.P. Burke, A. Farb, S.M. Schwartz Lessons from sudden coronary death: a comprehensive morphological classification scheme for atherosclerotic lesions Arterioscler Thromb Vasc Biol 20 2000 1262 1275 (Pubitemid 30262927)
-
(2000)
Arteriosclerosis, Thrombosis, and Vascular Biology
, vol.20
, Issue.5
, pp. 1262-1275
-
-
Virmani, R.1
Kolodgie, F.D.2
Burke, A.P.3
Farb, A.4
Schwartz, S.M.5
-
3
-
-
0026254046
-
Optical coherence tomography
-
D. Huang, E.A. Swanson, C.P. Lin Optical coherence tomography Science 254 1991 1178 1181 (Pubitemid 21917444)
-
(1991)
Science
, vol.254
, Issue.5035
, pp. 1178-1181
-
-
Huang, D.1
Swanson, E.A.2
Lin, C.P.3
Schuman, J.S.4
Stinson, W.G.5
Chang, W.6
Hee, M.R.7
Flotte, T.8
Gregory, K.9
Puliafito, C.A.10
Fujimoto, J.G.11
-
4
-
-
72049121587
-
A multicentre evaluation of the safety of intracoronary optical coherence tomography
-
P. Barlis, N. Gonzalo, C. Di Mario A multicentre evaluation of the safety of intracoronary optical coherence tomography EuroIntervention 5 2009 90 95
-
(2009)
EuroIntervention
, vol.5
, pp. 90-95
-
-
Barlis, P.1
Gonzalo, N.2
Di Mario, C.3
-
5
-
-
76049118483
-
Advantage of next-generation frequency-domain optical coherence tomography compared with conventional time-domain system in the assessment of coronary lesion
-
S. Takarada, T. Imanishi, Y. Liu Advantage of next-generation frequency-domain optical coherence tomography compared with conventional time-domain system in the assessment of coronary lesion Catheter Cardiovasc Interv 75 2010 202 206
-
(2010)
Catheter Cardiovasc Interv
, vol.75
, pp. 202-206
-
-
Takarada, S.1
Imanishi, T.2
Liu, Y.3
-
6
-
-
79952276829
-
Safety and feasibility of frequency domain optical coherence tomography to guide decision making in percutaneous coronary intervention
-
F. Imola, M.T. Mallus, V. Ramazzotti Safety and feasibility of frequency domain optical coherence tomography to guide decision making in percutaneous coronary intervention EuroIntervention 6 2010 575 581
-
(2010)
EuroIntervention
, vol.6
, pp. 575-581
-
-
Imola, F.1
Mallus, M.T.2
Ramazzotti, V.3
-
8
-
-
77954789924
-
Coronary optical frequency domain imaging (OFDI) for in vivo evaluation of stent healing: Comparison with light and electron microscopy
-
C. Templin, M. Meyer, M.F. Muller Coronary optical frequency domain imaging (OFDI) for in vivo evaluation of stent healing: comparison with light and electron microscopy Eur Heart J 31 2010 1792 1801
-
(2010)
Eur Heart J
, vol.31
, pp. 1792-1801
-
-
Templin, C.1
Meyer, M.2
Muller, M.F.3
-
9
-
-
40649083620
-
A bioabsorbable everolimus-eluting coronary stent system for patients with single de-novo coronary artery lesions (ABSORB): A prospective open-label trial
-
DOI 10.1016/S0140-6736(08)60415-8, PII S0140673608604158
-
J.A. Ormiston, P.W. Serruys, E. Regar A bioabsorbable everolimus-eluting coronary stent system for patients with single de-novo coronary artery lesions (ABSORB): a prospective open-label trial Lancet 371 2008 899 907 (Pubitemid 351384734)
-
(2008)
The Lancet
, vol.371
, Issue.9616
, pp. 899-907
-
-
Ormiston, J.A.1
Serruys, P.W.2
Regar, E.3
Dudek, D.4
Thuesen, L.5
Webster, M.W.6
Onuma, Y.7
Garcia-Garcia, H.M.8
McGreevy, R.9
Veldhof, S.10
-
10
-
-
77953662333
-
Reproducibility of quantitative optical coherence tomography for stent analysis
-
N. Gonzalo, H.M. Garcia-Garcia, P.W. Serruys Reproducibility of quantitative optical coherence tomography for stent analysis EuroIntervention 5 2009 224 232
-
(2009)
EuroIntervention
, vol.5
, pp. 224-232
-
-
Gonzalo, N.1
Garcia-Garcia, H.M.2
Serruys, P.W.3
-
11
-
-
71049115883
-
Accuracy and reproducibility of stent-strut thickness determined by optical coherence tomography
-
M. Terashima, S. Rathore, Y. Suzuki Accuracy and reproducibility of stent-strut thickness determined by optical coherence tomography J Invasive Cardiol 21 2009 602 605
-
(2009)
J Invasive Cardiol
, vol.21
, pp. 602-605
-
-
Terashima, M.1
Rathore, S.2
Suzuki, Y.3
-
12
-
-
79952796067
-
Reproducibility of coronary Fourier domain optical coherence tomography: Quantitative analysis of in vivo stented coronary arteries using three different software packages
-
T. Okamura, N. Gonzalo, J.L. Gutierrez-Chico Reproducibility of coronary Fourier domain optical coherence tomography: quantitative analysis of in vivo stented coronary arteries using three different software packages EuroIntervention 6 2010 371 379
-
(2010)
EuroIntervention
, vol.6
, pp. 371-379
-
-
Okamura, T.1
Gonzalo, N.2
Gutierrez-Chico, J.L.3
-
13
-
-
0037422532
-
Quantification of macrophage content in atherosclerotic plaques by optical coherence tomography
-
DOI 10.1161/01.CIR.0000044384.41037.43
-
G.J. Tearney, H. Yabushita, S.L. Houser Quantification of macrophage content in atherosclerotic plaques by optical coherence tomography Circulation 107 2003 113 119 (Pubitemid 36070942)
-
(2003)
Circulation
, vol.107
, Issue.1
, pp. 113-119
-
-
Tearney, G.J.1
Yabushita, H.2
Houser, S.L.3
Aretz, H.T.4
Jang, I.-K.5
Schlendorf, K.H.6
Kauffman, C.R.7
Shishkov, M.8
Halpern, E.F.9
Bouma, B.E.10
|