메뉴 건너뛰기




Volumn 1, Issue 2, 2008, Pages 168-173

In Vivo Comparison Between Optical Coherence Tomography and Intravascular Ultrasound for Detecting Small Degrees of In-Stent Neointima After Stent Implantation

Author keywords

[No Author keywords available]

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL MODEL; ANIMAL TISSUE; AREA UNDER THE CURVE; ARTERY INTIMA PROLIFERATION; ARTICLE; CONFIDENCE INTERVAL; CONTROLLED STUDY; CORONARY ARTERY CIRCUMFLEX BRANCH; CORRELATION ANALYSIS; DIAGNOSTIC ACCURACY; DIAGNOSTIC IMAGING; HISTOPATHOLOGY; IN VIVO STUDY; IN-STENT RESTENOSIS; INTERMETHOD COMPARISON; INTRAVASCULAR ULTRASOUND; LEFT ANTERIOR DESCENDING CORONARY ARTERY; NONHUMAN; OPTICAL COHERENCE TOMOGRAPHY; PRIORITY JOURNAL; RECEIVER OPERATING CHARACTERISTIC; RIGHT CORONARY ARTERY; SWINE;

EID: 41949118345     PISSN: 19368798     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jcin.2007.12.007     Document Type: Article
Times cited : (127)

References (17)
  • 1
    • 6944237687 scopus 로고    scopus 로고
    • Late thrombosis in drug-eluting coronary stents after discontinuation of antiplatelet therapy
    • McFadden E.P., Stabile E., Regar E., et al. Late thrombosis in drug-eluting coronary stents after discontinuation of antiplatelet therapy. Lancet 364 (2004) 1519-1521
    • (2004) Lancet , vol.364 , pp. 1519-1521
    • McFadden, E.P.1    Stabile, E.2    Regar, E.3
  • 2
    • 20044388113 scopus 로고    scopus 로고
    • Drug-eluting stent thrombosis: results from a pooled analysis including 10 randomized studies
    • Moreno R., Fernandez C., Hernandez R., et al. Drug-eluting stent thrombosis: results from a pooled analysis including 10 randomized studies. J Am Coll Cardiol 45 (2005) 954-959
    • (2005) J Am Coll Cardiol , vol.45 , pp. 954-959
    • Moreno, R.1    Fernandez, C.2    Hernandez, R.3
  • 3
    • 17844373254 scopus 로고    scopus 로고
    • Incidence, predictors, and outcome of thrombosis after successful implantation of drug-eluting stents
    • Iakovou I., Schmidt T., Bonizzoni E., et al. Incidence, predictors, and outcome of thrombosis after successful implantation of drug-eluting stents. JAMA 293 (2005) 2126-2130
    • (2005) JAMA , vol.293 , pp. 2126-2130
    • Iakovou, I.1    Schmidt, T.2    Bonizzoni, E.3
  • 4
    • 34248227700 scopus 로고    scopus 로고
    • Incomplete stent apposition and very late stent thrombosis after drug-eluting stent implantation
    • Cook S., Wenaweser P., Togni M., et al. Incomplete stent apposition and very late stent thrombosis after drug-eluting stent implantation. Circulation 115 (2007) 2426-2434
    • (2007) Circulation , vol.115 , pp. 2426-2434
    • Cook, S.1    Wenaweser, P.2    Togni, M.3
  • 5
    • 10744229988 scopus 로고    scopus 로고
    • Localized hypersensitivity and late coronary thrombosis secondary to a sirolimus-eluting stent: should we be cautious?
    • Virmani R., Guagliumi G., Farb A., et al. Localized hypersensitivity and late coronary thrombosis secondary to a sirolimus-eluting stent: should we be cautious?. Circulation 109 (2004) 701-705
    • (2004) Circulation , vol.109 , pp. 701-705
    • Virmani, R.1    Guagliumi, G.2    Farb, A.3
  • 6
    • 33745233024 scopus 로고    scopus 로고
    • Pathology of drug-eluting stents in humans: delayed healing and late thrombotic risk
    • Joner M., Finn A.V., Farb A., et al. Pathology of drug-eluting stents in humans: delayed healing and late thrombotic risk. J Am Coll Cardiol 48 (2006) 193-202
    • (2006) J Am Coll Cardiol , vol.48 , pp. 193-202
    • Joner, M.1    Finn, A.V.2    Farb, A.3
  • 7
    • 33847259689 scopus 로고    scopus 로고
    • Drug-eluting stent and coronary thrombosis: biological mechanisms and clinical implications
    • Luscher T.F., Steffel J., Eberli F.R., et al. Drug-eluting stent and coronary thrombosis: biological mechanisms and clinical implications. Circulation 115 (2007) 1051-1058
    • (2007) Circulation , vol.115 , pp. 1051-1058
    • Luscher, T.F.1    Steffel, J.2    Eberli, F.R.3
  • 8
    • 34248219973 scopus 로고    scopus 로고
    • Pathological correlates of late drug-eluting stent thrombosis: strut coverage as a marker of endothelialization
    • Finn A.V., Joner M., Nakazawa G., et al. Pathological correlates of late drug-eluting stent thrombosis: strut coverage as a marker of endothelialization. Circulation 115 (2007) 2435-2441
    • (2007) Circulation , vol.115 , pp. 2435-2441
    • Finn, A.V.1    Joner, M.2    Nakazawa, G.3
  • 9
    • 33845613478 scopus 로고    scopus 로고
    • Comparison of nonuniform rotational distortion between mechanical IVUS and OCT using a phantom model
    • Kawase Y., Suzuki Y., Ikeno F., et al. Comparison of nonuniform rotational distortion between mechanical IVUS and OCT using a phantom model. Ultrasound Med Biol 33 (2007) 67-73
    • (2007) Ultrasound Med Biol , vol.33 , pp. 67-73
    • Kawase, Y.1    Suzuki, Y.2    Ikeno, F.3
  • 10
    • 0037138571 scopus 로고    scopus 로고
    • Visualization of coronary atherosclerotic plaques in patients using optical coherence tomography: comparison with intravascular ultrasound
    • Jang I.K., Bouma B.E., Kang D.H., et al. Visualization of coronary atherosclerotic plaques in patients using optical coherence tomography: comparison with intravascular ultrasound. J Am Coll Cardiol 39 (2002) 604-609
    • (2002) J Am Coll Cardiol , vol.39 , pp. 604-609
    • Jang, I.K.1    Bouma, B.E.2    Kang, D.H.3
  • 11
    • 0037167693 scopus 로고    scopus 로고
    • Characterization of human atherosclerosis by optical coherence tomography
    • Yabushita H., Bouma B.E., Houser S.L., et al. Characterization of human atherosclerosis by optical coherence tomography. Circulation 106 (2002) 1640-1645
    • (2002) Circulation , vol.106 , pp. 1640-1645
    • Yabushita, H.1    Bouma, B.E.2    Houser, S.L.3
  • 12
    • 0037369227 scopus 로고    scopus 로고
    • Evaluation of intracoronary stenting by intravascular optical coherence tomography
    • Bouma B.E., Tearney G.J., Yabushita H., et al. Evaluation of intracoronary stenting by intravascular optical coherence tomography. Heart 89 (2003) 317-320
    • (2003) Heart , vol.89 , pp. 317-320
    • Bouma, B.E.1    Tearney, G.J.2    Yabushita, H.3
  • 13
    • 0028912131 scopus 로고
    • Intracoronary stenting without anticoagulation accomplished with intravascular ultrasound guidance
    • Colombo A., Hall P., Nakamura S., et al. Intracoronary stenting without anticoagulation accomplished with intravascular ultrasound guidance. Circulation 91 (1995) 1676-1688
    • (1995) Circulation , vol.91 , pp. 1676-1688
    • Colombo, A.1    Hall, P.2    Nakamura, S.3
  • 14
    • 33748197321 scopus 로고    scopus 로고
    • Diagnostic accuracy of optical coherence tomography and intravascular ultrasound for the detection and characterization of atherosclerotic plaque composition in ex-vivo coronary specimens: a comparison with histology
    • Rieber J., Meissner O., Babaryka G., et al. Diagnostic accuracy of optical coherence tomography and intravascular ultrasound for the detection and characterization of atherosclerotic plaque composition in ex-vivo coronary specimens: a comparison with histology. Coron Artery Dis 17 (2006) 425-430
    • (2006) Coron Artery Dis , vol.17 , pp. 425-430
    • Rieber, J.1    Meissner, O.2    Babaryka, G.3
  • 15
    • 33645862567 scopus 로고    scopus 로고
    • Drug-eluting stent strut distribution: a comparison between Cypher and Taxus by optical coherence tomography
    • Suzuki Y., Ikeno F., and Yeung A.C. Drug-eluting stent strut distribution: a comparison between Cypher and Taxus by optical coherence tomography. J Invasive Cardiol 18 (2006) 111-114
    • (2006) J Invasive Cardiol , vol.18 , pp. 111-114
    • Suzuki, Y.1    Ikeno, F.2    Yeung, A.C.3
  • 16
    • 0037072467 scopus 로고    scopus 로고
    • Intravascular ultrasound findings in the multicenter, randomized, double-blind RAVEL (RAndomized study with the sirolimus-eluting VElocity balloon-expandable stent in the treatment of patients with de novo native coronary artery Lesions) trial
    • Serruys P.W., Degertekin M., Tanabe K., et al. Intravascular ultrasound findings in the multicenter, randomized, double-blind RAVEL (RAndomized study with the sirolimus-eluting VElocity balloon-expandable stent in the treatment of patients with de novo native coronary artery Lesions) trial. Circulation 106 (2002) 798-803
    • (2002) Circulation , vol.106 , pp. 798-803
    • Serruys, P.W.1    Degertekin, M.2    Tanabe, K.3
  • 17
    • 34147135208 scopus 로고    scopus 로고
    • Evaluation by optical coherence tomography of neointimal coverage of sirolimus-eluting stent three months after implantation
    • Takano M., Inami S., Jang I.K., et al. Evaluation by optical coherence tomography of neointimal coverage of sirolimus-eluting stent three months after implantation. Am J Cardiol 99 (2007) 1033-1038
    • (2007) Am J Cardiol , vol.99 , pp. 1033-1038
    • Takano, M.1    Inami, S.2    Jang, I.K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.