메뉴 건너뛰기




Volumn 23, Issue 11, 2013, Pages 3197-3204

Effective dose estimates for cone beam computed tomography in interventional radiology

Author keywords

CBCT; Effective doses; Interventional radiology; MDCT; TLD measurement

Indexed keywords

ABDOMEN; ARTICLE; BONE MARROW; BRAIN; CALVARIA; CLINICAL PROTOCOL; COMPUTER ASSISTED TOMOGRAPHY; CONE BEAM COMPUTED TOMOGRAPHY; EXPERIMENTAL STUDY; EYE; HEAD; IMAGING; INTERVENTIONAL RADIOLOGY; MEDICAL TECHNOLOGY; MULTIDETECTOR COMPUTED TOMOGRAPHY; PHANTOM; PRIORITY JOURNAL; RADIATION DOSE; RADIOLOGIST; THERMOLUMINESCENCE DOSIMETER;

EID: 84885951688     PISSN: 09387994     EISSN: 14321084     Source Type: Journal    
DOI: 10.1007/s00330-013-2934-7     Document Type: Article
Times cited : (30)

References (18)
  • 1
    • 33744809303 scopus 로고    scopus 로고
    • Ultra high resolution flat panel volume CT: Fundamental principles, design architecture and system characterization
    • 16528556 10.1007/s00330-006-0156-y
    • Gupta R, Grasruck M, Suess et al (2006) Ultra high resolution flat panel volume CT: fundamental principles, design architecture and system characterization. Eur Radiol 16:1191-1205
    • (2006) Eur Radiol , vol.16 , pp. 1191-1205
    • Gupta, R.1    Grasruck, M.2    Suess3
  • 2
    • 84878699061 scopus 로고    scopus 로고
    • Radiation dose and image quality of X-ray volume imaging systems: Cone-beam computed tomography, digital subtraction angiography and digital fluoroscopy
    • 23250112 10.1007/s00330-012-2737-2
    • Paul J, Jacobi V, Farhang M, Bazrafshan B, Vogl TJ, Mbalisike EC (2012) Radiation dose and image quality of X-ray volume imaging systems: cone-beam computed tomography, digital subtraction angiography and digital fluoroscopy. Eur Radiol 23:1582-1593
    • (2012) Eur Radiol , vol.23 , pp. 1582-1593
    • Paul, J.1    Jacobi, V.2    Farhang, M.3    Bazrafshan, B.4    Vogl, T.J.5    Mbalisike, E.C.6
  • 3
    • 44149113722 scopus 로고    scopus 로고
    • C-arm cone-beam CT: General principles and technical considerations for use in interventional radiology
    • 18503894 10.1016/j.jvir.2008.02.002
    • Orth RC, Wallace MJ, Kuo MD (2008) C-arm cone-beam CT: general principles and technical considerations for use in interventional radiology. J Vasc Interv Radiol 19:814-820
    • (2008) J Vasc Interv Radiol , vol.19 , pp. 814-820
    • Orth, R.C.1    Wallace, M.J.2    Kuo, M.D.3
  • 4
    • 0242409404 scopus 로고    scopus 로고
    • The response of LiF thermoluminescence dosemeters to photon beams in the energy range from 30 kV X-rays to 60Co gamma rays
    • 10.1093/oxfordjournals.rpd.a006332 1:CAS:528:DC%2BD3sXpvVyktb4%3D
    • Davis SD, Ross CK, Mobit PN, Van der Zwan L, Chase WJ, Shortt KR (2003) The response of LiF thermoluminescence dosemeters to photon beams in the energy range from 30 kV X-rays to 60Co gamma rays. Radiat Prot Dosim 106:33-43
    • (2003) Radiat Prot Dosim , vol.106 , pp. 33-43
    • Davis, S.D.1    Ross, C.K.2    Mobit, P.N.3    Van Der Zwan, L.4    Chase, W.J.5    Shortt, K.R.6
  • 5
    • 0029922271 scopus 로고    scopus 로고
    • The quality dependence of LiF TLD in megavoltage photon beams: Monte Carlo simulation and experiments
    • 8778821 10.1088/0031-9155/41/3/004 1:STN:280:DyaK283ktlektQ%3D%3D
    • Mobit PN, Mayles P, Nahum AE (1996) The quality dependence of LiF TLD in megavoltage photon beams: Monte Carlo simulation and experiments. Phys Med Biol 41:387-398
    • (1996) Phys Med Biol , vol.41 , pp. 387-398
    • Mobit, P.N.1    Mayles, P.2    Nahum, A.E.3
  • 6
    • 33746041477 scopus 로고    scopus 로고
    • Dosimetry of 3 CBCT devices for oral and maxillofacial radiology: CB Mercuray, NewTom 3G and i-CAT
    • 16798915 10.1259/dmfr/14340323 1:STN:280:DC%2BD28vksFOgtg%3D%3D
    • Ludlow JB, Davies-Ludlow LE, Brooks SL, Howerton WB (2006) Dosimetry of 3 CBCT devices for oral and maxillofacial radiology: CB Mercuray, NewTom 3G and i-CAT. Dentomaxillofac Radiol 35:219-226
    • (2006) Dentomaxillofac Radiol , vol.35 , pp. 219-226
    • Ludlow, J.B.1    Davies-Ludlow, L.E.2    Brooks, S.L.3    Howerton, W.B.4
  • 7
    • 64949152317 scopus 로고    scopus 로고
    • Effective dose measured with a life size human phantom in a low earth orbit mission
    • 19202325 10.1269/jrr.08105
    • Yasuda H (2009) Effective dose measured with a life size human phantom in a low earth orbit mission. J Radiat Res 50:89-96
    • (2009) J Radiat Res , vol.50 , pp. 89-96
    • Yasuda, H.1
  • 8
    • 55349124127 scopus 로고    scopus 로고
    • International Commission on Radiological Protection Publication 103. Ann ICRP 37 (2-4)
    • International Commission on Radiological Protection (2007) The 2007 Recommendations of the ICRP. Publication 103. Ann ICRP 37 (2-4)
    • (2007) The 2007 Recommendations of the ICRP
  • 9
    • 0018461065 scopus 로고
    • Absorbed bone marrow dose in certain dental radiographic techniques
    • 285130 1:STN:280:DyaE1M7ltF2iuw%3D%3D
    • White SC, Rose TC (1979) Absorbed bone marrow dose in certain dental radiographic techniques. J Am Dent Assoc 98:553-558
    • (1979) J Am Dent Assoc , vol.98 , pp. 553-558
    • White, S.C.1    Rose, T.C.2
  • 10
    • 34948887091 scopus 로고    scopus 로고
    • Effective dose: How should it be applied to medical exposures?
    • 17646189 10.1259/bjr/25922439 1:STN:280:DC%2BD2srhtVSjug%3D%3D
    • Martin CJ (2007) Effective dose: how should it be applied to medical exposures? Br J Radiol 80:639-647
    • (2007) Br J Radiol , vol.80 , pp. 639-647
    • Martin, C.J.1
  • 11
    • 45149100678 scopus 로고    scopus 로고
    • Effective dose: A useful concept in diagnostic radiology?
    • 10.1093/rpd/ncn056
    • Brenner D, Huda W (2008) Effective dose: a useful concept in diagnostic radiology? Radiat Prot Dosim 128:503-508
    • (2008) Radiat Prot Dosim , vol.128 , pp. 503-508
    • Brenner, D.1    Huda, W.2
  • 12
    • 0036831529 scopus 로고    scopus 로고
    • AAPM/RSNA physics tutorial for residents: Topics in CT
    • 12432127 10.1148/rg.226025128
    • McNitt-Gray MF (2002) AAPM/RSNA physics tutorial for residents: topics in CT. Radiographics 22:1541-1553
    • (2002) Radiographics , vol.22 , pp. 1541-1553
    • McNitt-Gray, M.F.1
  • 13
    • 84857659783 scopus 로고    scopus 로고
    • Conversion coefficients for radiological protection quantities for external radiation exposures
    • International Commission on Radiological Protection Publication 116
    • International Commission on Radiological Protection (2010) Conversion coefficients for radiological protection quantities for external radiation exposures. Publication 116. Ann ICRP 40 (2-5)
    • (2010) Ann ICRP , vol.40 , Issue.2-5
  • 15
    • 51549088875 scopus 로고    scopus 로고
    • Converting dose-length product to effective dose at CT
    • 18710988 10.1148/radiol.2483071964
    • Huda W, Ogden KM, Khorasani MR (2008) Converting dose-length product to effective dose at CT. Radiology 248:995-1003
    • (2008) Radiology , vol.248 , pp. 995-1003
    • Huda, W.1    Ogden, K.M.2    Khorasani, M.R.3
  • 16
    • 4644293782 scopus 로고    scopus 로고
    • 16-detector multislice CT: Dosimetry estimation by TLD measurement compared with Monte Carlo simulation
    • 15326044 10.1259/bjr/48307881 1:STN:280:DC%2BD2cvhvVKhsg%3D%3D
    • Groves AM, Owen KE, Courtney HM et al (2004) 16-detector multislice CT: dosimetry estimation by TLD measurement compared with Monte Carlo simulation. Br J Radiol 77:662-665
    • (2004) Br J Radiol , vol.77 , pp. 662-665
    • Groves, A.M.1    Owen, K.E.2    Courtney, H.M.3
  • 17
    • 0028329726 scopus 로고
    • Comparison of two methods for assessing patient dose from computed tomography
    • 10.1259/0007-1285-67-796-360 1:STN:280:DyaK2c3ivVahtg%3D%3D
    • Geleijns J, Van Unnik JG, Zoetelief J, Zweers D, Broerse JJ (1994) Comparison of two methods for assessing patient dose from computed tomography. Br J Radiol 67:360-365
    • (1994) Br J Radiol , vol.67 , pp. 360-365
    • Geleijns, J.1    Van Unnik, J.G.2    Zoetelief, J.3    Zweers, D.4    Broerse, J.J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.