Volumn 106, Issue 1, 2003, Pages 33-43

The response of LiF thermoluminescence dosemeters to photon beams in the energy range from 30 kV X rays to 60Co gamma rays

Author keywords

[No Author keywords available]

Indexed keywords

CESIUM 137; COBALT 60; LITHIUM FLUORIDE;

EID: 0242409404     PISSN: 01448420     EISSN: None     Source Type: Journal    
DOI: 10.1093/oxfordjournals.rpd.a006332     Document Type: Article
Times cited : (134)

References (33)
  • 1
    • 0003942186 scopus 로고
    • Introduction to Radiological Physics and Radiation Dosimetry
    • New York: Wiley
    • Attix, F. H. Introduction to Radiological Physics and Radiation Dosimetry (New York: Wiley) (1986).
    • (1986)
    • Attix, F.H.1
  • 4
    • 0036392510 scopus 로고    scopus 로고
    • p(0.07) in mixed fields at varying energies of photons and beta radiation
    • p(0.07) in mixed fields at varying energies of photons and beta radiation. Radiat. Prot. Dosim. 101, 173-178 (2002).
    • (2002) Radiat. Prot. Dosim. , vol.101 , pp. 173-178
    • Pradhan, A.S.1
  • 5
    • 0032767975 scopus 로고    scopus 로고
    • LiF:Mg,Cu,P based environmental dosemeter and dose calculation algorithm
    • Perry, O. R., Moscovitch, M., Velbeck, K. J. and Rotunda, J. E. LiF:Mg,Cu,P based environmental dosemeter and dose calculation algorithm. Radiat. Prot. Dosim. 85, 273-281 (1999).
    • (1999) Radiat. Prot. Dosim. , vol.85 , pp. 273-281
    • Perry, O.R.1    Moscovitch, M.2    Velbeck, K.J.3    Rotunda, J.E.4
  • 6
    • 0028024465 scopus 로고
    • Thermoluminescence efficiency of LiF:Mg,Cu,P (MCP-N) detectors to photons, beta electrons, alpha particles and thermal neutrons
    • Bilski, P., Olko, P., Burgkhardt, B., Piesch, E. and Waligórski, M. P. R. Thermoluminescence efficiency of LiF:Mg,Cu,P (MCP-N) detectors to photons, beta electrons, alpha particles and thermal neutrons. Radiat. Prot. Dosim. 55, 31-38 (1994).
    • (1994) Radiat. Prot. Dosim. , vol.55 , pp. 31-38
    • Bilski, P.1    Olko, P.2    Burgkhardt, B.3    Piesch, E.4    Waligórski, M.P.R.5
  • 7
    • 0027257649 scopus 로고
    • Microdosimetric interpretation of the anomalous photon energy response of ultra-sensitive LiF:Mg,Cu,P TL dosemeters
    • Olko, P., Bilski, P., Ryba, E. and Niewiadomski, T. Microdosimetric interpretation of the anomalous photon energy response of ultra-sensitive LiF:Mg,Cu,P TL dosemeters. Radiat. Prot. Dosim. 47, 31-35 (1993).
    • (1993) Radiat. Prot. Dosim. , vol.47 , pp. 31-35
    • Olko, P.1    Bilski, P.2    Ryba, E.3    Niewiadomski, T.4
  • 8
    • 0029793320 scopus 로고    scopus 로고
    • Microdosimetric interpretation of thermoluminescence efficiency of LiF:Mg,Cu,P (MCP-N) detectors for weakly and densely ionising radiations
    • Olko, P. Microdosimetric interpretation of thermoluminescence efficiency of LiF:Mg,Cu,P (MCP-N) detectors for weakly and densely ionising radiations. Radiat. Prot. Dosim. 65, 151-158 (1996).
    • (1996) Radiat. Prot. Dosim. , vol.65 , pp. 151-158
    • Olko, P.1
  • 11
    • 0002751646 scopus 로고
    • The quality and LET dependence of three thermoluminescent dosimeters and their potential use as secondary standards
    • Washington, DC: US Atomic Energy Commission
    • Tochilin, E., Goldstein, N. and Lyman, J. T. The quality and LET dependence of three thermoluminescent dosimeters and their potential use as secondary standards. In: Proc. Second Int. Conf. on Luminescence Dosimetry (Washington, DC: US Atomic Energy Commission) (1968).
    • (1968) Proc. Second Int. Conf. on Luminescence Dosimetry
    • Tochilin, E.1    Goldstein, N.2    Lyman, J.T.3
  • 12
    • 0242398652 scopus 로고
    • The IRS thermoluminescent dosimetry system
    • NRC Report PIRS-0369 (Ottawa, Canada: National Research Council)
    • Janovský, I. and Ross, C. K. The IRS thermoluminescent dosimetry system. NRC Report PIRS-0369 (Ottawa, Canada: National Research Council) (1993).
    • (1993)
    • Janovský, I.1    Ross, C.K.2
  • 13
    • 0003454762 scopus 로고
    • 60Co exposure standard
    • NRC Report PIRS-0052 (Ottawa: National Research Council)
    • 60Co exposure standard. NRC Report PIRS-0052 (Ottawa: National Research Council) (1986).
    • (1986)
    • Shortt, K.R.1    Ross, C.K.2
  • 15
    • 0242398653 scopus 로고
    • The Canadian standard free-air chamber for medium quality X-rays
    • Henry, W. H. and Garrett, C. The Canadian standard free-air chamber for medium quality X-rays. Can. J. Phys. 38, 1677-1689 (1960).
    • (1960) Can. J. Phys. , vol.38 , pp. 1677-1689
    • Henry, W.H.1    Garrett, C.2
  • 16
    • 0003653709 scopus 로고    scopus 로고
    • X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy - Part 1: Radiation characteristics and production methods
    • ISO ISO Report 4037-1:1996 (Geneva: International Organization for Standardization)
    • ISO. X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy - Part 1: Radiation characteristics and production methods. ISO Report 4037-1:1996 (Geneva: International Organization for Standardization) (1996).
    • (1996)
  • 17
    • 0034104708 scopus 로고    scopus 로고
    • Accurate condensed history Monte Carlo simulation of electron transport. I. EGSnrc, the new EGS4 version
    • Kawrakow, I. Accurate condensed history Monte Carlo simulation of electron transport. I. EGSnrc, the new EGS4 version. Med. Phys. 27, 485-498 (2000).
    • (2000) Med. Phys. , vol.27 , pp. 485-498
    • Kawrakow, I.1
  • 18
    • 58149413803 scopus 로고
    • Photon cross sections from 1 keV to 100 MeV for elements Z = 1 to Z = 100
    • Storm, E. and Israel, H. I. Photon cross sections from 1 keV to 100 MeV for elements Z = 1 to Z = 100. Atomic Data and Nuclear Data Tables 7, 565-681 (1970).
    • (1970) Atomic Data and Nuclear Data Tables , vol.7 , pp. 565-681
    • Storm, E.1    Israel, H.I.2
  • 19
    • 0003966102 scopus 로고    scopus 로고
    • XCOM: Photon cross section database (Version 1.2)
    • Gaithersburg, MD: National Institute of Standards and Technology
    • Berger, M. J., Hubbell, J. H., Seltzer, S. M., Coursey, J. S. and Zucker, D. S. XCOM: photon cross section database (Version 1.2). http://physics.nist.gov/xcom (Gaithersburg, MD: National Institute of Standards and Technology) (1999).
    • (1999)
    • Berger, M.J.1    Hubbell, J.H.2    Seltzer, S.M.3    Coursey, J.S.4    Zucker, D.S.5
  • 20
    • 0242565836 scopus 로고    scopus 로고
    • Implementation of NIST XCOM-based photoelectric cross-sections in EGSnrc
    • Abstract
    • Hobeila, F. and Seuntjens, J. Implementation of NIST XCOM-based photoelectric cross-sections in EGSnrc (Abstract). Med. Phys. 29, 1353 (2002).
    • (2002) Med. Phys. , vol.29 , pp. 1353
    • Hobeila, F.1    Seuntjens, J.2
  • 21
    • 0033861873 scopus 로고    scopus 로고
    • Monte Carlo study of correction factors for Spencer-Attix cavity theory at photon energies at or above 100 keV
    • Borg, J., Kawrakow, I., Rogers, D. W. O. and Seuntjens, J. P. Monte Carlo study of correction factors for Spencer-Attix cavity theory at photon energies at or above 100 keV. Med. Phys. 27, 1804-1813 (2000).
    • (2000) Med. Phys. , vol.27 , pp. 1804-1813
    • Borg, J.1    Kawrakow, I.2    Rogers, D.W.O.3    Seuntjens, J.P.4
  • 22
    • 0003588807 scopus 로고
    • A catalogue of spectra used for the calibration of dosemeters
    • GSF Report 560 (München: Gesellschaft für Strahlen und Umweltforschung)
    • Seelentag, W. W., Panzer, W., Drexler, G., Platz, L. and Santner, F. A catalogue of spectra used for the calibration of dosemeters. GSF Report 560 (München: Gesellschaft für Strahlen und Umweltforschung) (1979).
    • (1979)
    • Seelentag, W.W.1    Panzer, W.2    Drexler, G.3    Platz, L.4    Santner, F.5
  • 23
    • 0242650429 scopus 로고    scopus 로고
    • Distribution area for EGSnrc: A Unix/Linux-based system for Monte Carlo simulation of electron and photon transport
    • www.irs.inms.nrc.ca/inms/irs/irs.html
    • Rogers, D. W. O. and Kawrakow, I. Distribution area for EGSnrc: a Unix/Linux-based system for Monte Carlo simulation of electron and photon transport. www.irs.inms.nrc.ca/inms/irs/irs.html (2003).
    • (2003)
    • Rogers, D.W.O.1    Kawrakow, I.2
  • 24
    • 0003523753 scopus 로고    scopus 로고
    • Tables of X-ray mass attenuation coefficients and mass energy-absorption coefficients (Version 1.03, Online)
    • Gaithersburg, MD: National Institute of Standards and Technology
    • Hubbell, J. H. and Seltzer, S. M. Tables of X-ray mass attenuation coefficients and mass energy-absorption coefficients (Version 1.03, Online). http://physics.nist.gov/xaamdi (Gaithersburg, MD: National Institute of Standards and Technology) (1997).
    • (1997)
    • Hubbell, J.H.1    Seltzer, S.M.2
  • 25
    • 0003602495 scopus 로고    scopus 로고
    • Catalogue of X-ray spectra and their characteristic data - ISO and DIN radiation qualities, therapy and diagnostic radiation qualities, unfiltered X-ray spectra
    • PTB Report: PTB-Dos-34 (Braunschweig: Physikalisch-Technische Bundesanstalt)
    • Ankerhold, U. Catalogue of X-ray spectra and their characteristic data - ISO and DIN radiation qualities, therapy and diagnostic radiation qualities, unfiltered X-ray spectra. PTB Report: PTB-Dos-34 (Braunschweig: Physikalisch-Technische Bundesanstalt) (2000).
    • (2000)
    • Ankerhold, U.1
  • 26
    • 0032772891 scopus 로고    scopus 로고
    • Characterisation of the low energy X-ray response of Polish TLDs to synchrotron radiation and the determination of some TLD quantities
    • Ipe, N. E., Fassò, A., Kase, K. R., Kaur, R., Bilski, P. and Olko, P. Characterisation of the low energy X-ray response of Polish TLDs to synchrotron radiation and the determination of some TLD quantities. Radiat. Prot. Dosim. 84, 169-173 (1999).
    • (1999) Radiat. Prot. Dosim. , vol.84 , pp. 169-173
    • Ipe, N.E.1    Fassò, A.2    Kase, K.R.3    Kaur, R.4    Bilski, P.5    Olko, P.6
  • 27
    • 0032794348 scopus 로고    scopus 로고
    • Modelling of the thermoluminescence response of LiF:Mg,Cu,P (MCP-N) detectors after doses of low energy photons
    • Olko, P., Bilski, P., Budzanowski, M., Waligórski, M. P. R., Fasso, A. and Ipe, N. Modelling of the thermoluminescence response of LiF:Mg,Cu,P (MCP-N) detectors after doses of low energy photons. Radiat. Prot. Dosim. 84, 103-108 (1999).
    • (1999) Radiat. Prot. Dosim. , vol.84 , pp. 103-108
    • Olko, P.1    Bilski, P.2    Budzanowski, M.3    Waligórski, M.P.R.4    Fasso, A.5    Ipe, N.6
  • 28
    • 0018395816 scopus 로고
    • The low- and high-temperature response of lithium fluoride dosemeters to X-rays
    • Budd, T., Marshall, M., Peaple, H. J. and Douglas, J. A. The low- and high-temperature response of lithium fluoride dosemeters to X-rays. Phys. Med. Biol. 24, 71-80 (1979).
    • (1979) Phys. Med. Biol. , vol.24 , pp. 71-80
    • Budd, T.1    Marshall, M.2    Peaple, H.J.3    Douglas, J.A.4
  • 29
    • 0036387863 scopus 로고    scopus 로고
    • Microdosimetric interpretation of the photon energy response of LiF:Mg,Ti detectors
    • Olko, P., Bilski, P. and Kim, J.-L. Microdosimetric interpretation of the photon energy response of LiF:Mg,Ti detectors. Radiat. Prot. Dosim. 100, 119-122 (2002).
    • (2002) Radiat. Prot. Dosim. , vol.100 , pp. 119-122
    • Olko, P.1    Bilski, P.2    Kim, J.-L.3
  • 30
    • 0029891839 scopus 로고    scopus 로고
    • Accuracy of Monte Carlo photon transport simulation in characterizing brachytherapy dosimeter energy-response artifacts
    • Das, R. K., Li, Z., Perera, H. and Williamson, J. F. Accuracy of Monte Carlo photon transport simulation in characterizing brachytherapy dosimeter energy-response artifacts. Phys. Med. Biol. 41, 995-1006 (1996).
    • (1996) Phys. Med. Biol. , vol.41 , pp. 995-1006
    • Das, R.K.1    Li, Z.2    Perera, H.3    Williamson, J.F.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.