메뉴 건너뛰기




Volumn 15, Issue 5, 2013, Pages 637-644

Development of a New Implant Primary Stability Parameter: Insertion Torque Revisited

Author keywords

Dental implants; Insertion torque; Primary stability; Variable torque work

Indexed keywords

TOOTH IMPLANT;

EID: 84885859149     PISSN: 15230899     EISSN: 17088208     Source Type: Journal    
DOI: 10.1111/j.1708-8208.2011.00392.x     Document Type: Article
Times cited : (40)

References (17)
  • 1
    • 42149175697 scopus 로고    scopus 로고
    • Immediate / early loading of dental implants: clinical documentation and presentation of a treatment concept
    • Östman PO. Immediate / early loading of dental implants: clinical documentation and presentation of a treatment concept. Periodontol 2000 2008; 47:90-112.
    • (2008) Periodontol 2000 , vol.47 , pp. 90-112
    • Östman, P.O.1
  • 4
    • 42149147336 scopus 로고    scopus 로고
    • Implant stability measurements using resonance frequency analysis: biological and biomechanical aspects and clinical implications
    • Sennerby L, Meredith N. Implant stability measurements using resonance frequency analysis: biological and biomechanical aspects and clinical implications. Periodontol 2000 2008; 47:51-66.
    • (2008) Periodontol 2000 , vol.47 , pp. 51-66
    • Sennerby, L.1    Meredith, N.2
  • 5
    • 77955863113 scopus 로고    scopus 로고
    • Determination of primary stability: a comparison of the surgeon's perception and objective measurements
    • Degidi M, Daprile G, Piattelli A. Determination of primary stability: a comparison of the surgeon's perception and objective measurements. Int J Oral Maxillofac Implants 2010; 25:558-561.
    • (2010) Int J Oral Maxillofac Implants , vol.25 , pp. 558-561
    • Degidi, M.1    Daprile, G.2    Piattelli, A.3
  • 7
    • 0031128359 scopus 로고    scopus 로고
    • High-precision, cost-effective system for producing thin sections of oral tissues containing dental implants
    • Piattelli A, Scarano A, Quaranta M. High-precision, cost-effective system for producing thin sections of oral tissues containing dental implants. Biomaterials 1997; 18:577-579.
    • (1997) Biomaterials , vol.18 , pp. 577-579
    • Piattelli, A.1    Scarano, A.2    Quaranta, M.3
  • 8
    • 33645084797 scopus 로고    scopus 로고
    • Resonance frequency analysis and damping capacity assessment. Part I: an in vitro study on measurement reliability and a method of comparison in the determination of primary dental implant stability
    • Lachmann S, Jäger B, Axmann D, Gomez-Roman G, Groten M, Weber H. Resonance frequency analysis and damping capacity assessment. Part I: an in vitro study on measurement reliability and a method of comparison in the determination of primary dental implant stability. Clin Oral Implants Res 2006; 17:75-79.
    • (2006) Clin Oral Implants Res , vol.17 , pp. 75-79
    • Lachmann, S.1    Jäger, B.2    Axmann, D.3    Gomez-Roman, G.4    Groten, M.5    Weber, H.6
  • 9
    • 60049098379 scopus 로고    scopus 로고
    • Implant stability in relation to osseointegration: an experimental study in the Labrador dog
    • Abrahamsson I, Linder E, Lang NP. Implant stability in relation to osseointegration: an experimental study in the Labrador dog. Clin Oral Implants Res 2009; 20:313-318.
    • (2009) Clin Oral Implants Res , vol.20 , pp. 313-318
    • Abrahamsson, I.1    Linder, E.2    Lang, N.P.3
  • 10
    • 4444312847 scopus 로고    scopus 로고
    • A comparison between cutting torque and resonance frequency in the assessment of primary stability and final torque capacity of standard and TiUnite single-tooth implants under immediate loading
    • Da Cunha HA, Francischone CE, Filho HN, De Oliveira RC. A comparison between cutting torque and resonance frequency in the assessment of primary stability and final torque capacity of standard and TiUnite single-tooth implants under immediate loading. Int J Oral Maxillofac Implants 2004; 19:578-585.
    • (2004) Int J Oral Maxillofac Implants , vol.19 , pp. 578-585
    • Da Cunha, H.A.1    Francischone, C.E.2    Filho, H.N.3    De Oliveira, R.C.4
  • 11
    • 47749094639 scopus 로고    scopus 로고
    • Clinical outcome of immediately loaded dental implants bioactivated with plasma rich in growth factors: a 5-year retrospective study
    • Anitua E, Orive G, Aguirre JJ, Andía I. Clinical outcome of immediately loaded dental implants bioactivated with plasma rich in growth factors: a 5-year retrospective study. J Periodontol 2008; 79:1168-1176.
    • (2008) J Periodontol , vol.79 , pp. 1168-1176
    • Anitua, E.1    Orive, G.2    Aguirre, J.J.3    Andía, I.4
  • 12
    • 79551528408 scopus 로고    scopus 로고
    • Osseointegration and stability of a modified sand-blasted acid-etched implant: an experimental pilot study in sheep
    • Abdel-Haq J, Karabuda CZ, Arisan V, Mutlu Z, Kürkçü M. Osseointegration and stability of a modified sand-blasted acid-etched implant: an experimental pilot study in sheep. Clin Oral Implants Res 2011; 22:265-274.
    • (2011) Clin Oral Implants Res , vol.22 , pp. 265-274
    • Abdel-Haq, J.1    Karabuda, C.Z.2    Arisan, V.3    Mutlu, Z.4    Kürkçü, M.5
  • 14
    • 0033176199 scopus 로고    scopus 로고
    • A comparison between placement torque and resonance frequency measurements of maxillary implants. A 20-month clinical study
    • Friberg B, Sennerby L, Meredith N, Lekholm U. A comparison between placement torque and resonance frequency measurements of maxillary implants. A 20-month clinical study. Int J Oral Maxillofac Surg 1999; 28:297-303.
    • (1999) Int J Oral Maxillofac Surg , vol.28 , pp. 297-303
    • Friberg, B.1    Sennerby, L.2    Meredith, N.3    Lekholm, U.4
  • 16
    • 84885836672 scopus 로고    scopus 로고
    • Primary stability and initial bone-to-implant contact: the effects on immediate placement and restoration of dental implants
    • Meltzer A. Primary stability and initial bone-to-implant contact: the effects on immediate placement and restoration of dental implants. J Implant Reconstructive Dent 2009; 1:35-41.
    • (2009) J Implant Reconstructive Dent , vol.1 , pp. 35-41
    • Meltzer, A.1
  • 17
    • 79952060388 scopus 로고    scopus 로고
    • Comparison of initial stability parameters and histomorphometric analysis of implants inserted into extraction sockets: human fresh cadaver study
    • Jun SH, Chang BM, Weber HP, Kwon JJ. Comparison of initial stability parameters and histomorphometric analysis of implants inserted into extraction sockets: human fresh cadaver study. Int J Oral Maxillofac Implants 2010; 25:985-990.
    • (2010) Int J Oral Maxillofac Implants , vol.25 , pp. 985-990
    • Jun, S.H.1    Chang, B.M.2    Weber, H.P.3    Kwon, J.J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.