Volumn 25, Issue 3, 2010, Pages 558-561

Determination of primary stability: A comparison of the surgeon’s perception and objective measurements

Author keywords

Dental implants; Immediate loading; Implant stability; Insertion torque; Resonance frequency analysis

Indexed keywords

ADULT; AGED; ARTICLE; BONE REGENERATION; CHI SQUARE DISTRIBUTION; COMPARATIVE STUDY; FEMALE; HUMAN; MALE; MIDDLE AGED; NONPARAMETRIC TEST; ORAL SURGERY; TOOTH IMPLANTATION; TOOTH PROSTHESIS; TORQUE; VIBRATION;

EID: 77955863113     PISSN: 08822786     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (59)

References (9)
  • 2
    • 42149175697 scopus 로고    scopus 로고
    • Immediate/early loading of dental implants: Clinical documentation and presentation of a treatment concept
    • Östman PO. Immediate/early loading of dental implants: Clinical documentation and presentation of a treatment concept. Periodontol 2000 2008;47: 90-112.
    • (2008) Periodontol 2000 , vol.47 , pp. 90-112
    • Östman, P.O.1
  • 5
    • 34547174147 scopus 로고    scopus 로고
    • Relations between the bone density values from computerized tomography and implant stability parameters: A clinical study of 230 regular platform implants
    • Turkyilmaz I, Tumer C, Ozbek EN, Tözüm TF. Relations between the bone density values from computerized tomography and implant stability parameters: A clinical study of 230 regular platform implants. J Clin Periodontol 2007;34: 716-722.
    • (2007) J Clin Periodontol , vol.34 , pp. 716-722
    • Turkyilmaz, I.1    Tumer, C.2    Ozbek, E.N.3    Tözüm, T.F.4
  • 6
    • 33751351701 scopus 로고    scopus 로고
    • Assessment of correlation between computerized tomography values of the bone, and maximum torque and resonance frequency values at dental implant placement
    • Turkyilmaz I, Tözüm TF, Tumer C, Ozbek EN. Assessment of correlation between computerized tomography values of the bone, and maximum torque and resonance frequency values at dental implant placement. J Oral Rehabil 2006;33: 881-888.
    • (2006) J Oral Rehabil , vol.33 , pp. 881-888
    • Turkyilmaz, I.1    Tözüm, T.F.2    Tumer, C.3    Ozbek, E.N.4
  • 7
    • 33747877743 scopus 로고    scopus 로고
    • A comparison between insertion torque and resonance frequency in the assessment of torque capacity and primary stability of Brånemark system implants
    • Turkyilmaz I. A comparison between insertion torque and resonance frequency in the assessment of torque capacity and primary stability of Brånemark system implants. J Oral Rehabil 2006;33: 754-759.
    • (2006) J Oral Rehabil , vol.33 , pp. 754-759
    • Turkyilmaz, I.1
  • 8
    • 32644446492 scopus 로고    scopus 로고
    • Resonace frequency analysis measurements of implants at placement surgery
    • Östman PO, Hellman M, Wendelhag I, Sennerby L. Resonace frequency analysis measurements of implants at placement surgery. Int J Prosthodont 2006;19: 77-83.
    • (2006) Int J Prosthodont , vol.19 , pp. 77-83
    • Östman, P.O.1    Hellman, M.2    Wendelhag, I.3    Sennerby, L.4
  • 9
    • 42149147336 scopus 로고    scopus 로고
    • Implant stability measurements using resonance frequency analysis: Biological and biomechanical aspects and clinical implications
    • Sennerby L, Meredith N. Implant stability measurements using resonance frequency analysis: Biological and biomechanical aspects and clinical implications. Periodontol 2000 2008;47: 51-66.
    • (2008) Periodontol 2000 , vol.47 , pp. 51-66
    • Sennerby, L.1    Meredith, N.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.