1
-
-
0141928682
-
Digital x-ray tomosynthesis: Current state of the art and clinical potential
-
J. T. Dobbins and D. J. Godfrey, "Digital x-ray tomosynthesis: Current state of the art and clinical potential," Phys. Med. Biol. 48, R65-R106 (2003).
-
(2003)
Phys. Med. Biol.
, vol.48
-
-
Dobbins, J.T.1
Godfrey, D.J.2
-
2
-
-
56749165474
-
Three-dimensional linear system analysis for breast tomosynthesis
-
B. Zhao and W. Zhao, "Three-dimensional linear system analysis for breast tomosynthesis," Med. Phys. 35, 5219-5232 (2008).
-
(2008)
Med. Phys.
, vol.35
, pp. 5219-5232
-
-
Zhao, B.1
Zhao, W.2
-
3
-
-
4644334876
-
A comparison of reconstruction algorithms for breast tomosynthesis
-
T. Wu, R. H. Moore, E. A. Rafferty, and D. B. Kopans, "A comparison of reconstruction algorithms for breast tomosynthesis," Med. Phys. 31, 2636-2647 (2004).
-
(2004)
Med. Phys.
, vol.31
, pp. 2636-2647
-
-
Wu, T.1
Moore, R.H.2
Rafferty, E.A.3
Kopans, D.B.4
-
4
-
-
33749404804
-
A comparative study of limited-angle cone-beam reconstruction methods for breast tomosynthesis
-
Y. Zhang, H.-P. Chan, B. Sahiner, J. Wei, M. M. Goodsitt, L. M. Hadjiiski, J. Ge, and C. Zhou, "A comparative study of limited-angle cone-beam reconstruction methods for breast tomosynthesis," Med. Phys. 33, 3781-3795 (2006).
-
(2006)
Med. Phys.
, vol.33
, pp. 3781-3795
-
-
Zhang, Y.1
Chan, H.-P.2
Sahiner, B.3
Wei, J.4
Goodsitt, M.M.5
Hadjiiski, L.M.6
Ge, J.7
Zhou, C.8
-
5
-
-
0027659444
-
Algebraic reconstruction techniques can be made computationally efficient [positron emission tomography application]
-
G. T. Herman and L. B. Meyer, "Algebraic reconstruction techniques can be made computationally efficient [positron emission tomography application]," IEEE Trans. Med. Imaging 12, 600-609 (1993).
-
(1993)
IEEE Trans. Med. Imaging
, vol.12
, pp. 600-609
-
-
Herman, G.T.1
Meyer, L.B.2
-
6
-
-
0028027815
-
A projection access order for speedy convergence of ART (algebraic reconstruction technique): A multilevel scheme for computed tomography
-
H. Guan and R. Gordon, "A projection access order for speedy convergence of ART (algebraic reconstruction technique): A multilevel scheme for computed tomography," Phys. Med. Biol. 39, 2005-2022 (1994).
-
(1994)
Phys. Med. Biol.
, vol.39
, pp. 2005-2022
-
-
Guan, H.1
Gordon, R.2
-
7
-
-
0031877044
-
Combining various projection access schemes with the algebraic reconstruction technique for low-contrast detection in computed tomography
-
H. Guan, R. Gordon, and Y. Zhu, "Combining various projection access schemes with the algebraic reconstruction technique for low-contrast detection in computed tomography," Phys. Med. Biol. 43, 2413-2421 (1998).
-
(1998)
Phys. Med. Biol.
, vol.43
, pp. 2413-2421
-
-
Guan, H.1
Gordon, R.2
Zhu, Y.3
-
8
-
-
50949130689
-
Characterization of projection ordering in iterative reconstruction methods for breast tomosynthesis
-
Springer, Berlin Heidelberg
-
G. Wu, J. Mainprize, and M. Yaffe, "Characterization of projection ordering in iterative reconstruction methods for breast tomosynthesis," in Digital Mammography: IWDM (Springer, Berlin Heidelberg, 2008), pp. 601-605.
-
(2008)
Digital Mammography: Iwdm
, pp. 601-605
-
-
Wu, G.1
Mainprize, J.2
Yaffe, M.3
-
9
-
-
0035049369
-
Human observer detection experiments with mammograms and power-law noise
-
A. E. Burgess, F. L. Jacobson, and P. F. Judy, "Human observer detection experiments with mammograms and power-law noise," Med. Phys. 28, 419-437 (2001).
-
(2001)
Med. Phys.
, vol.28
, pp. 419-437
-
-
Burgess, A.E.1
Jacobson, F.L.2
Judy, P.F.3
-
10
-
-
0023196389
-
X-ray characterisation of normal and neoplas-tic breast tissues
-
P. C. Johns and M. J. Yaffe, "X-ray characterisation of normal and neoplas-tic breast tissues," Phys. Med. Biol. 32, 675-695 (1987).
-
(1987)
Phys. Med. Biol.
, vol.32
, pp. 675-695
-
-
Johns, P.C.1
Yaffe, M.J.2
-
11
-
-
0021952059
-
Fast calculation of the exact radiological path for a three-dimensional CT array
-
R. L. Siddon, "Fast calculation of the exact radiological path for a three-dimensional CT array," Med. Phys. 12, 252-255 (1985).
-
(1985)
Med. Phys.
, vol.12
, pp. 252-255
-
-
Siddon, R.L.1
-
12
-
-
84994082593
-
A fast algorithm to calculate the exact radiological path through a pixel or voxel space
-
F. Jacobs, E. Sundermann, B. De Sutter, M. Christiaens, and I. Lemahieu, "A fast algorithm to calculate the exact radiological path through a pixel or voxel space," J. Comput. Inf. Technol. 6, 89-94 (1998).
-
(1998)
J. Comput. Inf. Technol.
, vol.6
, pp. 89-94
-
-
Jacobs, F.1
Sundermann, E.2
De Sutter, B.3
Christiaens, M.4
Lemahieu, I.5
-
13
-
-
0035999415
-
Normalized glandular dose (DgN) coefficients for arbitrary X-ray spectra in mammography: Computer-fit values of Monte Carlo derived data
-
J. M. Boone, "Normalized glandular dose (DgN) coefficients for arbitrary X-ray spectra in mammography: Computer-fit values of Monte Carlo derived data," Med. Phys. 29, 869-875 (2002).
-
(2002)
Med. Phys.
, vol.29
, pp. 869-875
-
-
Boone, J.M.1
-
14
-
-
77950553921
-
Task-based assessment of breast tomosyn-thesis: Effect of acquisition parameters and quantum noise
-
I. Reiser and R. M. Nishikawa, "Task-based assessment of breast tomosyn-thesis: Effect of acquisition parameters and quantum noise," Med. Phys. 37, 1591-1600 (2010).
-
(2010)
Med. Phys.
, vol.37
, pp. 1591-1600
-
-
Reiser, I.1
Nishikawa, R.M.2
-
15
-
-
63849136026
-
Optimization of the acquisition geometry in digital tomosynthesis of the breast
-
I. Sechopoulos and C. Ghetti, "Optimization of the acquisition geometry in digital tomosynthesis of the breast," Med. Phys. 36, 1199-1207 (2009).
-
(2009)
Med. Phys.
, vol.36
, pp. 1199-1207
-
-
Sechopoulos, I.1
Ghetti, C.2
-
16
-
-
0033237794
-
Anti-aliased three-dimensional cone-beam reconstruction of low-contrast objects with algebraic methods
-
K. Mueller, R. Yagel, and J. J. Wheller, "Anti-aliased three-dimensional cone-beam reconstruction of low-contrast objects with algebraic methods," IEEE Trans. Med. Imaging 18, 519-537 (1999).
-
(1999)
IEEE Trans. Med. Imaging
, vol.18
, pp. 519-537
-
-
Mueller, K.1
Yagel, R.2
Wheller, J.J.3
-
17
-
-
0021344602
-
Simultaneous algebraic reconstruction technique (SART): A superior implementation of the art algorithm
-
A. H. Andersen and A. C. Kak, "Simultaneous algebraic reconstruction technique (SART): A superior implementation of the art algorithm," Ultrason. Imaging 6, 81-94 (1984).
-
(1984)
Ultrason. Imaging
, vol.6
, pp. 81-94
-
-
Andersen, A.H.1
Kak, A.C.2
-
18
-
-
0024627075
-
Algebraic reconstruction in CT from limited views
-
A. H. Andersen, "Algebraic reconstruction in CT from limited views," IEEE Trans. Med. Imaging 8, 50-55 (1989).
-
(1989)
IEEE Trans. Med. Imaging
, vol.8
, pp. 50-55
-
-
Andersen, A.H.1
-
19
-
-
0029394375
-
Globally convergent algorithms for maximum a posteriori transmission tomography
-
K. Lange and J. A. Fessler, "Globally convergent algorithms for maximum a posteriori transmission tomography," IEEE Trans. Image Process. 4, 1430-1438 (1995).
-
(1995)
IEEE Trans. Image Process.
, vol.4
, pp. 1430-1438
-
-
Lange, K.1
Fessler, J.A.2
-
20
-
-
33745655231
-
Voting strategy for artifact reduction in digital breast tomosynthesis
-
T. Wu, R. H. Moore, and D. B. Kopans, "Voting strategy for artifact reduction in digital breast tomosynthesis," Med. Phys. 33, 2461-2471 (2006).
-
(2006)
Med. Phys.
, vol.33
, pp. 2461-2471
-
-
Wu, T.1
Moore, R.H.2
Kopans, D.B.3
-
21
-
-
84864856812
-
Out-of-plane artifact reduction in tomosynthesis based on regression modeling and outlier detection
-
Springer, Berlin Heidelberg
-
S. Abdurahman, A. Jerebko, T. Mertelmeier, T. Lasser, and N. Navab, "Out-of-plane artifact reduction in tomosynthesis based on regression modeling and outlier detection," in Breast Imaging (Springer, Berlin Heidelberg, 2012), pp. 729-736.
-
(2012)
Breast Imaging
, pp. 729-736
-
-
Abdurahman, S.1
Jerebko, A.2
Mertelmeier, T.3
Lasser, T.4
Navab, N.5
-
22
-
-
0028700063
-
Accelerated image reconstruction using ordered subsets of projection data
-
H. Hudson and R. Larkin, "Accelerated image reconstruction using ordered subsets of projection data," IEEE Trans. Med. Imaging 13, 601-609 (1994).
-
(1994)
IEEE Trans. Med. Imaging
, vol.13
, pp. 601-609
-
-
Hudson, H.1
Larkin, R.2
-
23
-
-
0038444409
-
Convergence studies on iterative algorithms for image reconstruction
-
M. Jiang and G. Wang, "Convergence studies on iterative algorithms for image reconstruction," IEEE Trans. Med. Imaging 22, 569-579 (2003).
-
(2003)
IEEE Trans. Med. Imaging
, vol.22
, pp. 569-579
-
-
Jiang, M.1
Wang, G.2
-
24
-
-
0025587714
-
Convergence of EM image reconstruction algorithms with gibbs smoothing
-
K. Lange, "Convergence of EM image reconstruction algorithms with Gibbs smoothing," IEEE Trans. Med. Imaging 9, 439-446 (1990).
-
(1990)
IEEE Trans. Med. Imaging
, vol.9
, pp. 439-446
-
-
Lange, K.1
-
25
-
-
0033088416
-
The rose model, revisited
-
A. E. Burgess, "The Rose model, revisited," J. Opt. Soc. Am. A: Opt, Image Sci. Vis. 16, 633-646 (1999).
-
(1999)
J. Opt. Soc. Am. A: Opt, Image Sci. Vis.
, vol.16
, pp. 633-646
-
-
Burgess, A.E.1
-
26
-
-
0034868385
-
Lesion detection in digital mammograms
-
A. E. Burgess, "Lesion detection in digital mammograms," Proc. SPIE 4320, 555-560 (2001).
-
(2001)
Proc. SPIE
, vol.4320
, pp. 555-560
-
-
Burgess, A.E.1
-
27
-
-
0027141897
-
Dynamic range requirements in digital mammography
-
A. Maidment, R. Fahrig, and M. Yaffe, "Dynamic range requirements in digital mammography," Med. Phys. 20, 1621-1633 (1993).
-
(1993)
Med. Phys.
, vol.20
, pp. 1621-1633
-
-
Maidment, A.1
Fahrig, R.2
Yaffe, M.3
-
28
-
-
54949086053
-
Comparison of model and human observer performance for detection and discrimination tasks using dual-energy x-ray images
-
S. Richard and J. H. Siewerdsen, "Comparison of model and human observer performance for detection and discrimination tasks using dual-energy x-ray images," Med. Phys. 35, 5043-5053 (2008).
-
(2008)
Med. Phys.
, vol.35
, pp. 5043-5053
-
-
Richard, S.1
Siewerdsen, J.H.2
-
29
-
-
77952363141
-
Anatomical background and generalized detectability in tomosynthesis and cone-beam CT
-
G. J. Gang, D. J. Tward, J. Lee, and J. H. Siewerdsen, "Anatomical background and generalized detectability in tomosynthesis and cone-beam CT," Med. Phys. 37, 1948-1965 (2010).
-
(2010)
Med. Phys.
, vol.37
, pp. 1948-1965
-
-
Gang, G.J.1
Tward, D.J.2
Lee, J.3
Siewerdsen, J.H.4
-
30
-
-
0003908115
-
-
ICRU Report No. 54 Bethesda, MD
-
P. Sharp, C. E. Metz, R. F. Wagner, K. J. Myers, and A. E. Burgess, "Medical imaging: The assessment of image quality," ICRU Report No. 54 (Bethesda, MD, 1996), pp. 1-88.
-
(1996)
Medical Imaging: The Assessment of Image Quality
, pp. 1-88
-
-
Sharp, P.1
Metz, C.E.2
Wagner, R.F.3
Myers, K.J.4
Burgess, A.E.5
-
31
-
-
84856951871
-
Spectral analysis of mam-mographic images using a multitaper method
-
G. Wu, J. G. Mainprize, and M. J. Yaffe, "Spectral analysis of mam-mographic images using a multitaper method," Med. Phys. 39, 801-810 (2012).
-
(2012)
Med. Phys.
, vol.39
, pp. 801-810
-
-
Wu, G.1
Mainprize, J.G.2
Yaffe, M.J.3
-
32
-
-
70350718948
-
Enhanced imaging of microcalcifications in digital breast tomosynthesis through improved image-reconstruction algorithms
-
E. Y. Sidky, X. Pan, I. S. Reiser, R. M. Nishikawa, R. H. Moore, and D. B. Kopans, "Enhanced imaging of microcalcifications in digital breast tomosynthesis through improved image-reconstruction algorithms," Med. Phys. 36, 4920-4932 (2009).
-
(2009)
Med. Phys.
, vol.36
, pp. 4920-4932
-
-
Sidky, E.Y.1
Pan, X.2
Reiser, I.S.3
Nishikawa, R.M.4
Moore, R.H.5
Kopans, D.B.6
|